{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T04:16:21Z","timestamp":1772165781919,"version":"3.50.1"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,5,7]],"date-time":"2025-05-07T00:00:00Z","timestamp":1746576000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,5,7]],"date-time":"2025-05-07T00:00:00Z","timestamp":1746576000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["82271067"],"award-info":[{"award-number":["82271067"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"DOI":"10.1186\/s12886-025-04106-8","type":"journal-article","created":{"date-parts":[[2025,5,7]],"date-time":"2025-05-07T02:28:50Z","timestamp":1746584930000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A case report of implantable collamer lens removal with cataract extraction and TECNIS Symfony extended range of vision intraocular lens (ZXR00) implantation"],"prefix":"10.1186","volume":"25","author":[{"given":"Peilin","family":"Yue","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Enjie","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhenyu","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xudong","family":"Song","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,5,7]]},"reference":[{"issue":"2","key":"4106_CR1","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1016\/j.ophtha.2011.07.047","volume":"119","author":"DH Lee","year":"2012","unstructured":"Lee DH, Choi SH, Chung ES, et al. Correlation between preoperative biometry and posterior chamber Phakic Visian implantable collamer Lens vaulting [J]. Ophthalmology. 2012;119(2):272\u20137.","journal-title":"Ophthalmology"},{"issue":"3","key":"4106_CR2","first-page":"87","volume":"73","author":"H Kocov\u00e1","year":"2017","unstructured":"Kocov\u00e1 H, Vlkov\u00e1 E, Michalcov\u00e1 L, et al. Incidence of cataract following implantation of a posterior-chamber Phakic lens ICL (Implantable collamer Lens) - long-term results [J]. Cesk Slov Oftalmol. 2017;73(3):87\u201393.","journal-title":"Cesk Slov Oftalmol"},{"issue":"4","key":"4106_CR3","doi-asserted-by":"publisher","first-page":"632","DOI":"10.1016\/j.ajo.2011.06.031","volume":"153","author":"T Kojima","year":"2012","unstructured":"Kojima T, Yokoyama S, Ito M, et al. Optimization of an implantable collamer lens sizing method using high-frequency ultrasound biomicroscopy [J]. Am J Ophthalmol. 2012;153(4):632\u20137.","journal-title":"Am J Ophthalmol"},{"issue":"5","key":"4106_CR4","doi-asserted-by":"publisher","first-page":"327","DOI":"10.3928\/1081597X-20090617-11","volume":"26","author":"T Kojima","year":"2010","unstructured":"Kojima T, Maeda M, Yoshida Y, et al. Posterior chamber Phakic implantable collamer lens: changes in vault during 1 year [J]. J Refract Surg. 2010;26(5):327\u201332.","journal-title":"J Refract Surg"},{"issue":"5","key":"4106_CR5","doi-asserted-by":"publisher","first-page":"873","DOI":"10.1016\/j.jcrs.2010.11.040","volume":"37","author":"JF Alfonso","year":"2011","unstructured":"Alfonso JF, Baamonde B, Fern\u00e1ndez-Vega L, et al. Posterior chamber collagen copolymer Phakic intraocular lenses to correct myopia: five-year follow-up [J]. J Cataract Refract Surg. 2011;37(5):873\u201380.","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"4106_CR6","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1016\/j.ophtha.2011.07.001","volume":"119","author":"C Du","year":"2012","unstructured":"Du C, Wang J, Wang X, et al. Ultrasound biomicroscopy of anterior segment accommodative changes with posterior chamber Phakic intraocular lens in high myopia [J]. Ophthalmology. 2012;119(1):99\u2013105.","journal-title":"Ophthalmology"},{"issue":"1","key":"4106_CR7","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1016\/j.jcrs.2011.07.035","volume":"38","author":"JF Alfonso","year":"2012","unstructured":"Alfonso JF, Fern\u00e1ndez-Vega L, Lisa C, et al. Central vault after Phakic intraocular lens implantation: correlation with anterior chamber depth, white-to-white distance, spherical equivalent, and patient age [J]. J Cataract Refract Surg. 2012;38(1):46\u201353.","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"4106_CR8","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1186\/s12886-018-0830-2","volume":"18","author":"Y Zhu","year":"2018","unstructured":"Zhu Y, Zhu H, Jia Y, et al. Changes in anterior chamber volume after implantation of posterior chamber Phakic intraocular lens in high myopia [J]. BMC Ophthalmol. 2018;18(1):185.","journal-title":"BMC Ophthalmol"},{"issue":"9","key":"4106_CR9","doi-asserted-by":"publisher","first-page":"1454","DOI":"10.1016\/j.jcrs.2013.12.022","volume":"40","author":"X Cao","year":"2014","unstructured":"Cao X, Tong J, Wang Y, et al. Long-term ultrasound biomicroscopy observation of position changes of a copolymer posterior chamber Phakic intraocular lens [J]. J Cataract Refract Surg. 2014;40(9):1454\u201361.","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"4106_CR10","doi-asserted-by":"publisher","first-page":"800","DOI":"10.1016\/j.jcrs.2014.07.039","volume":"41","author":"JF Alfonso","year":"2015","unstructured":"Alfonso JF, Lisa C, Fern\u00e1ndez-Vega L, et al. Prevalence of cataract after collagen copolymer Phakic intraocular lens implantation for myopia, hyperopia, and astigmatism [J]. J Cataract Refract Surg. 2015;41(4):800\u20135.","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"4106_CR11","first-page":"1014","volume":"10","author":"KY Hwang","year":"2017","unstructured":"Hwang KY, Lim SA, Chung SH. A case of hypermature cataract formation following implantation of an implantable collamer lens with an Aquaport [J]. Int J Ophthalmol. 2017;10(6):1014\u20135.","journal-title":"Int J Ophthalmol"},{"issue":"5","key":"4106_CR12","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1016\/j.jcjo.2017.11.018","volume":"53","author":"HV Gimbel","year":"2018","unstructured":"Gimbel HV, LeClair BM, Jabo B, et al. Incidence of implantable collamer lens-induced cataract [J]. Can J Ophthalmol. 2018;53(5):518\u201322.","journal-title":"Can J Ophthalmol"},{"key":"4106_CR13","doi-asserted-by":"publisher","first-page":"2129","DOI":"10.2147\/OPTH.S175901","volume":"12","author":"S Black","year":"2018","unstructured":"Black S. A clinical assessment of visual performance of combining the TECNIS(\u00ae) symfony extended range of vision IOL (ZXR00) with the +\u20093.25 D TECNIS multifocal 1-piece IOL (ZLB00) in subjects undergoing bilateral cataract extraction [J]. Clin Ophthalmol. 2018;12:2129\u201336.","journal-title":"Clin Ophthalmol"},{"issue":"6","key":"4106_CR14","doi-asserted-by":"publisher","first-page":"542","DOI":"10.1097\/APO.0000000000000439","volume":"10","author":"YJ Jeon","year":"2021","unstructured":"Jeon YJ, Yoon Y, Kim TI, et al. Comparison between an intraocular Lens with extended depth of focus (Tecnis symfony ZXR00) and a new monofocal intraocular Lens with enhanced intermediate vision (Tecnis Eyhance ICB00) [J]. Asia Pac J Ophthalmol (Phila). 2021;10(6):542\u20137.","journal-title":"Asia Pac J Ophthalmol (Phila)"},{"issue":"6","key":"4106_CR15","doi-asserted-by":"publisher","first-page":"3461","DOI":"10.1177\/11206721221093024","volume":"32","author":"DE Shin","year":"2022","unstructured":"Shin DE, Lee H, Kim TI, et al. Comparison of visual results and optical quality of two presbyopia-correcting intraocular lenses: TECNIS symfony versus TECNIS synergy [J]. Eur J Ophthalmol. 2022;32(6):3461\u20139.","journal-title":"Eur J Ophthalmol"},{"issue":"1","key":"4106_CR16","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1186\/s40662-022-00317-y","volume":"9","author":"D Guo","year":"2022","unstructured":"Guo D, Meng J, Zhang K, et al. Tolerance to lens Tilt and decentration of two multifocal intraocular lenses: using the quick contrast sensitivity function method [J]. Eye Vis (Lond). 2022;9(1):45.","journal-title":"Eye Vis (Lond)"},{"issue":"1","key":"4106_CR17","doi-asserted-by":"publisher","first-page":"28","DOI":"10.3928\/1081597X-20191204-01","volume":"36","author":"KL Christopher","year":"2020","unstructured":"Christopher KL, Miller DC, Patnaik JL, et al. Comparison of visual outcomes of extended depth of focus lenses in patients with and without previous laser refractive surgery [J]. J Refract Surg. 2020;36(1):28\u201333.","journal-title":"J Refract Surg"},{"issue":"7","key":"4106_CR18","doi-asserted-by":"publisher","first-page":"784","DOI":"10.1097\/j.jcrs.0000000000000883","volume":"48","author":"TJ Ferguson","year":"2022","unstructured":"Ferguson TJ, Downes RA, Randleman JB. IOL power calculations after LASIK or PRK: Barrett True-K biometer-only calculation strategy yields equivalent outcomes as a multiple formula approach [J]. J Cataract Refract Surg. 2022;48(7):784\u20139.","journal-title":"J Cataract Refract Surg"},{"key":"4106_CR19","doi-asserted-by":"crossref","unstructured":"Savage DE, Pantanelli SM. An update on intraocular lens power calculations in eyes with previous laser refractive surgery [J]. Curr Opin Ophthalmol; 2023.","DOI":"10.1097\/ICU.0000000000001004"},{"issue":"3","key":"4106_CR20","doi-asserted-by":"publisher","first-page":"207","DOI":"10.3928\/1081597X-20201123-01","volume":"37","author":"J Bernardes","year":"2021","unstructured":"Bernardes J, Raimundo M, Lobo C, et al. A comparison of intraocular Lens power calculation formulas in high myopia [J]. J Refract Surg. 2021;37(3):207\u201311.","journal-title":"J Refract Surg"},{"issue":"3","key":"4106_CR21","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1016\/j.jcrs.2015.11.039","volume":"42","author":"A Abulafia","year":"2016","unstructured":"Abulafia A, Hill WE, Koch DD, et al. Accuracy of the Barrett True-K formula for intraocular lens power prediction after laser in situ keratomileusis or photorefractive keratectomy for myopia [J]. J Cataract Refract Surg. 2016;42(3):363\u20139.","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"4106_CR22","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1097\/ICU.0000000000000822","volume":"33","author":"J Chung","year":"2022","unstructured":"Chung J, Bu JJ, Afshari NA. Advancements in intraocular lens power calculation formulas [J]. Curr Opin Ophthalmol. 2022;33(1):35\u201340.","journal-title":"Curr Opin Ophthalmol"},{"issue":"10","key":"4106_CR23","doi-asserted-by":"publisher","first-page":"1416","DOI":"10.1016\/j.jcrs.2019.05.020","volume":"45","author":"L Wang","year":"2019","unstructured":"Wang L, Spektor T, de Souza RG, et al. Evaluation of total keratometry and its accuracy for intraocular lens power calculation in eyes after corneal refractive surgery [J]. J Cataract Refract Surg. 2019;45(10):1416\u201321.","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"4106_CR24","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1016\/j.ophtha.2020.10.031","volume":"128","author":"SM Pantanelli","year":"2021","unstructured":"Pantanelli SM, Lin CC, Al-Mohtaseb Z, et al. Intraocular Lens power calculation in eyes with previous excimer laser surgery for myopia: A report by the American academy of ophthalmology [J]. Ophthalmology. 2021;128(5):781\u201392.","journal-title":"Ophthalmology"},{"issue":"1","key":"4106_CR25","doi-asserted-by":"publisher","first-page":"22","DOI":"10.4103\/tjo.tjo_38_21","volume":"12","author":"L Wang","year":"2022","unstructured":"Wang L, Koch DD. Intraocular lens power calculations in eyes with previous corneal refractive surgery: challenges, approaches, and outcomes [J]. Taiwan J Ophthalmol. 2022;12(1):22\u201331.","journal-title":"Taiwan J Ophthalmol"},{"issue":"11","key":"4106_CR26","doi-asserted-by":"publisher","first-page":"e121","DOI":"10.1016\/j.ophtha.2020.06.054","volume":"128","author":"L Wang","year":"2021","unstructured":"Wang L, Koch DD. Intraocular Lens power calculations in eyes with previous corneal refractive surgery: review and expert opinion [J]. Ophthalmology. 2021;128(11):e121\u201331.","journal-title":"Ophthalmology"},{"issue":"12","key":"4106_CR27","doi-asserted-by":"publisher","first-page":"2732","DOI":"10.4103\/ijo.IJO_2111_20","volume":"68","author":"K Doctor","year":"2020","unstructured":"Doctor K, Vunnava KP, Shroff R, et al. Simplifying and Understanding various topographic indices for keratoconus using Scheimpflug based topographers [J]. Indian J Ophthalmol. 2020;68(12):2732\u201343.","journal-title":"Indian J Ophthalmol"},{"key":"4106_CR28","doi-asserted-by":"crossref","unstructured":"Jones JJ, Jones YJ, Jin GJ. Indications and outcomes of intraocular lens exchange during a recent 5-year period [J]. Am J Ophthalmol, 2014, 157(1): 154\u2013\u200962.e1.","DOI":"10.1016\/j.ajo.2013.08.019"},{"issue":"6","key":"4106_CR29","doi-asserted-by":"publisher","first-page":"e0252787","DOI":"10.1371\/journal.pone.0252787","volume":"16","author":"EK Antwi-Adjei","year":"2021","unstructured":"Antwi-Adjei EK, Owusu E, Kobia-Acquah E, et al. Evaluation of postoperative refractive error correction after cataract surgery [J]. PLoS ONE. 2021;16(6):e0252787.","journal-title":"PLoS ONE"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-025-04106-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-025-04106-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-025-04106-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,7]],"date-time":"2025-05-07T02:28:52Z","timestamp":1746584932000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-025-04106-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,7]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["4106"],"URL":"https:\/\/doi.org\/10.1186\/s12886-025-04106-8","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-3914315\/v1","asserted-by":"object"}]},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,7]]},"assertion":[{"value":"31 January 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 April 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 May 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written and signed informed consent from the patient involved in this report was obtained for the publication of their personal and clinical details along with any identifying images to be published in this study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"276"}}