{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,23]],"date-time":"2025-05-23T10:40:08Z","timestamp":1747996808263,"version":"3.41.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,5,23]],"date-time":"2025-05-23T00:00:00Z","timestamp":1747958400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,5,23]],"date-time":"2025-05-23T00:00:00Z","timestamp":1747958400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"Innovation& Transfer Fund of Peking University Third Hospital","award":["BYSYZHKC2021108","BYSYZHKC2021108","BYSYZHKC2021108","BYSYZHKC2021108","BYSYZHKC2021108"],"award-info":[{"award-number":["BYSYZHKC2021108","BYSYZHKC2021108","BYSYZHKC2021108","BYSYZHKC2021108","BYSYZHKC2021108"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"DOI":"10.1186\/s12886-025-04127-3","type":"journal-article","created":{"date-parts":[[2025,5,23]],"date-time":"2025-05-23T10:03:23Z","timestamp":1747994603000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Risk factors for error in refractive astigmatism after toric intraocular lens implantation in Chinese patients"],"prefix":"10.1186","volume":"25","author":[{"given":"Mengyao","family":"Zhang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rui","family":"Qin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanfeng","family":"Liao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qianqian","family":"Ji","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ying","family":"Hong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,5,23]]},"reference":[{"key":"4127_CR1","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2020.09.026","author":"R Rampat","year":"2021","unstructured":"Rampat R, Gatinel D. Multifocal and extended Depth-of-Focus intraocular lenses in 2020. Ophthalmology. 2021. https:\/\/doi.org\/10.1016\/j.ophtha.2020.09.026.","journal-title":"Ophthalmology"},{"key":"4127_CR2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20180530-02","author":"B Cochener","year":"2018","unstructured":"Cochener B, Boutillier G, Lamard M, Auberger-Zagnoli C. A comparative evaluation of a new generation of diffractive trifocal and extended depth of focus intraocular lenses. J Refract Surg. 2018. https:\/\/doi.org\/10.3928\/1081597X-20180530-02.","journal-title":"J Refract Surg"},{"key":"4127_CR3","unstructured":"Barrett GD. Understanding intraocular lens calculation and biometry. J Cataract Refract Surg 202110.1097\/j.jcrs.0000000000000842"},{"key":"4127_CR4","doi-asserted-by":"publisher","unstructured":"Hoffer KJ, Savini G. Update on intraocular Lens power calculation study protocols: the better way to design and report clinical trials. Ophthalmology. 2021. https:\/\/doi.org\/10.1016\/j.ophtha.2020.07.005.","DOI":"10.1016\/j.ophtha.2020.07.005"},{"key":"4127_CR5","doi-asserted-by":"publisher","unstructured":"Kane JX, Chang DF. Intraocular Lens power formulas, biometry, and intraoperative aberrometry: A review. Ophthalmology. 2021. https:\/\/doi.org\/10.1016\/j.ophtha.2020.08.010.","DOI":"10.1016\/j.ophtha.2020.08.010"},{"key":"4127_CR6","doi-asserted-by":"publisher","unstructured":"Keshav V, Henderson BA. Astigmatism management with intraocular Lens surgery,.ophthalmology.2021https:\/\/doi.org\/10.1016\/j.ophtha.2020.08.011","DOI":"10.1016\/j.ophtha.2020.08.011"},{"key":"4127_CR7","unstructured":"Chen W, Zuo C, Chen C, Su J, Luo L, Congdon N, Liu Y. Prevalence of corneal astigmatism before cataract surgery in Chinese patients. J Cataract Refract Surg 201310.1016\/j.jcrs.2012.08.060"},{"key":"4127_CR8","volume-title":"StatPearls [Internet]","author":"A Mohankumar","year":"2023","unstructured":"Mohankumar A, Mohan S.,Toric intraocular lenses. StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2023."},{"key":"4127_CR9","unstructured":"Lake JC, Victor G, Clare G, Porf\u00edrio GJ, Kernohan A, Evans JR. Toric intraocular lens versus limbal relaxing incisions for corneal astigmatism after phacoemulsification.,cochrane. Database Syst Rev 201910.1002\/14651858.CD012801.pub2"},{"key":"4127_CR10","unstructured":"Sun GYF, Luo T, Liu JH, Ma YY, Liu BK, Zheng RJ, Qi MY. H,The rotational stability of toric intraocular lenses and influencing factors in cataract patients with different axial length. Zhonghua Yan Ke Za Zhi 202010.3760\/cma.j.issn.0412-4081"},{"key":"4127_CR11","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S407414","author":"A Gauthier","year":"2023","unstructured":"Gauthier A, Awidi AA, Noble PM, Daoud YJ. Factors predictive of refractive error after toric Lens implantation. Clin Ophthalmol. 2023. https:\/\/doi.org\/10.2147\/OPTH.S407414.","journal-title":"Clin Ophthalmol"},{"key":"4127_CR12","doi-asserted-by":"publisher","unstructured":"Shammas HJ, Yu F, Shammas MC, Jivrajka R, Hakimeh C. Predicted vs measured posterior corneal astigmatism for toric intraocular lens calculations,j cataract refract Surg.2022. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000819","DOI":"10.1097\/j.jcrs.0000000000000819"},{"key":"4127_CR13","doi-asserted-by":"publisher","unstructured":"R\u00e9mignon CH, Levron A, Agard E, Douma I, El-Chehab H, Brunet O, Sejournet L, Billant J, Dot C.,Impact of total corneal astigmatism estimated with the Abulafia-Koch formula versus measured with a SS-OCT biometer on the refractive outcomes of a toric intraocular Lens in cataract surgery. J Refract Surg. 2023. https:\/\/doi.org\/10.3928\/1081597X-20230103-04.","DOI":"10.3928\/1081597X-20230103-04"},{"key":"4127_CR14","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-020-01726-0","author":"Z Zhang","year":"2020","unstructured":"Zhang Z, Li H, Zhou J, Zhang Y, Zhang S. Clinical evaluation of toric intraocular lens implantation based on iTrace wavefront keratometric astigmatism. BMC Ophthalmol. 2020. https:\/\/doi.org\/10.1186\/s12886-020-01726-0.","journal-title":"BMC Ophthalmol"},{"key":"4127_CR15","doi-asserted-by":"publisher","unstructured":"Xue K, Jolly JK, Mall SP, Haldar S, Rosen PH, MacLaren RE. Real-world refractive outcomes of toric intraocular lens implantation in a united Kingdom National health service setting. BMC Ophthalmol. 2018. https:\/\/doi.org\/10.1186\/s12886-018-0692-7.","DOI":"10.1186\/s12886-018-0692-7"},{"key":"4127_CR16","unstructured":"Huang YT, Lin CJ, Lai CT, Hsia NY, Tien PT, Bair H, Chen HS, Chiang CC, Lin JM, Chen WL, Wu WC, Tsai YY. Astigmatism management with Astigmatism-Correcting intraocular Lens using two toric Calculators - A comparative case series. Clin Ophthalmol 202110.2147\/OPTH.S325234"},{"key":"4127_CR17","doi-asserted-by":"publisher","unstructured":"Zhu X, Meng J, He W, Rong X, Lu Y. Comparison of the rotational stability between plate-haptic toric and C-loop haptic toric IOLs in myopic eyes. J Cataract Refract Surg 2020 DOI:https:\/\/doi.org\/10.1186\/s12886-017-0528-x","DOI":"10.1186\/s12886-017-0528-x"},{"key":"4127_CR18","doi-asserted-by":"publisher","unstructured":"Ma D, Shen J, Qiu T, Zhang L, Hua Z, Cai L, Yang J. Rotational stability of plate-haptic toric intraocular lenses in Asian eyes: risk period for intraocular lens rotation and its influencing factors. J Cataract Refract Surg. 2023. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001107.","DOI":"10.1097\/j.jcrs.0000000000001107"},{"key":"4127_CR19","doi-asserted-by":"publisher","unstructured":"Christopher KL, Patnaik JL, Ifantides C, Miller DC, Davidson RS, Taravella MJ, Lynch A, Wagner B. Time utilization and refractive prediction enhancement associated with intraoperative aberrometry use during cataract surgery. Clin Ophthalmol. 2021. https:\/\/doi.org\/10.2147\/OPTH.S287573.","DOI":"10.2147\/OPTH.S287573"},{"key":"4127_CR20","doi-asserted-by":"publisher","unstructured":"Chen X, Gu X, Wang W, Xiao W, Jin G, Wang L, Dai Y, Zhang E, Ruan X, Liu Z, Luo L, Liu Y. Characteristics and factors associated with intraocular lens Tilt and decentration after cataract surgery. J Cataract Refract Surg. 2020. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000219.","DOI":"10.1097\/j.jcrs.0000000000000219"},{"key":"4127_CR21","doi-asserted-by":"publisher","unstructured":"Wang L, Jin G, Zhang J, Chen X, Tan X, Wang W, Ruan X, Gu X, He M, Liu Z, Luo L, Liu Y. Clinically significant intraocular Lens decentration and Tilt in highly myopic eyes: A Swept-Source optical coherence tomography study. Am J Ophthalmol. 2022. https:\/\/doi.org\/10.1016\/j.ajo.2021.08.017.","DOI":"10.1016\/j.ajo.2021.08.017"},{"key":"4127_CR22","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20200729-03","author":"N Hirnschall","year":"2020","unstructured":"Hirnschall N, Findl O, Bayer N, Leisser C, Norrby S, Zimper E, Hoffmann P. Sources of error in toric intraocular Lens power calculation. J Refract Surg. 2020. https:\/\/doi.org\/10.3928\/1081597X-20200729-03.","journal-title":"J Refract Surg"},{"key":"4127_CR23","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000653","author":"Y Yao","year":"2021","unstructured":"Yao Y, Meng J, He W, Zhang K, Wei L, Cheng K, Lu Y, Zhu X. Associations between anterior segment parameters and rotational stability of a plate-haptic toric intraocular lens. J Cataract Refract Surg. 2021. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000653.","journal-title":"J Cataract Refract Surg"},{"key":"4127_CR24","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-017-0528-x","author":"W He","year":"2017","unstructured":"He W, Zhu X, Du Y, et al. Clinical efficacy of implantation of toric intraocular lenses with different incision positions: a comparative study of steep-axis incision and non-steep-axis incision. BMC Ophthalmol. 2017. https:\/\/doi.org\/10.1186\/s12886-017-0528-x.","journal-title":"BMC Ophthalmol"},{"key":"4127_CR25","doi-asserted-by":"publisher","unstructured":"Kaufman AR, Pineda R 2. nd. Intraoperative aberrometry: an update on applications and outcomes. Curr Opin Ophthalmol. 2023. https:\/\/doi.org\/10.1097\/ICU.0000000000000915.","DOI":"10.1097\/ICU.0000000000000915"},{"key":"4127_CR26","doi-asserted-by":"crossref","unstructured":"Yang S, Byun YS, Kim HS, Chung SH. Comparative accuracy of Barrett toric calculator with and without posterior corneal astigmatism measurements and the Kane toric formula. Am J Ophthalmol 202110.1016\/j.ajo.2021.05.028","DOI":"10.1016\/j.ajo.2021.05.028"},{"key":"4127_CR27","doi-asserted-by":"publisher","DOI":"10.1038\/s41433-019-0489-9","author":"J Skrzypecki","year":"2019","unstructured":"Skrzypecki J, Sanghvi Patel M, Suh LH. Performance of the Barrett toric calculator with and without measurements of posterior corneal curvature. Eye (Lond). 2019. https:\/\/doi.org\/10.1038\/s41433-019-0489-9.","journal-title":"Eye (Lond)"},{"key":"4127_CR28","doi-asserted-by":"publisher","DOI":"10.3109\/02713683","author":"PR Preussner","year":"2015","unstructured":"Preussner PR, Hoffmann P, Wahl J. Impact of posterior corneal surface on toric intraocular lens (IOL) calculation. Curr Eye Res. 2015. https:\/\/doi.org\/10.3109\/02713683.","journal-title":"Curr Eye Res"},{"key":"4127_CR29","unstructured":"Raufi N, James C, Kuo A, Vann R. Intraoperative aberrometry vs modern preoperative formulas in predicting intraocular lens power. J Cataract Refract Surg 202010.1097\/j.jcrs.0000000000000173"},{"key":"4127_CR30","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.02.020","author":"N Visser","year":"2013","unstructured":"Visser N, Bauer NJ, Nuijts RM. Toric intraocular lenses: historical overview, patient selection, IOL calculation, surgical techniques, clinical outcomes, and complications. J Cataract Refract Surg. 2013. https:\/\/doi.org\/10.1016\/j.jcrs.2013.02.020.","journal-title":"J Cataract Refract Surg"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-025-04127-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-025-04127-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-025-04127-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,23]],"date-time":"2025-05-23T10:03:27Z","timestamp":1747994607000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-025-04127-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,23]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["4127"],"URL":"https:\/\/doi.org\/10.1186\/s12886-025-04127-3","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,23]]},"assertion":[{"value":"1 November 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 May 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 May 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study protocol was approved by the Institutional Review Board of Peking University Third Hospital. A written informed consent regarding surgery was obtained from each patient before surgery. All methods were carried out in accordance with relevant guidelines and regulations.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not Applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"309"}}