{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,5]],"date-time":"2026-01-05T14:45:21Z","timestamp":1767624321203,"version":"3.41.0"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T00:00:00Z","timestamp":1751328000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Zeiss"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Objectives<\/jats:title>\n            <jats:p>To investigate the effect of adjunct micro-interventional pre-treatment for nucleus disassembly on the surgical efficiency of non-cavitating lensectomy during cataract surgery.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods and analysis<\/jats:title>\n            <jats:p>12 surgeons performed 512 consecutive cataract extractions using a sonic cavitation-free lensectomy with or without adjunct pre-treatment for nucleus disassembly. There were 2 interventional arms including (1) lensectomy without adjunct pre-treatment and (2) lensectomy with micro-interventional miLOOP pre-treatment.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Successful lensectomy was achieved in all eyes using cavitation-free sonic lensectomy. Average baseline cataract density was 2.28 and 2.39 in the three groups, respectively. Compared to no pre-treatment, nucleus evacuation time was 24% (p\u2009=\u2009&lt;\u20090.001) faster with micro-interventional nucleus disassembly. Irrigation\/aspiration (I\/A) time was 14% faster with the micro-interventional pre-treatment (p\u2009=\u2009&lt;\u20090.001). Irrigation fluid use was 24% less with micro-interventional. There was a low rate of capsular tear of 1 case across 512 cases with no other unanticipated complications.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>Micro-interventional pre-treatment for nucleus disassembly was associated with improved lensectomy time and fluidic efficiency compared to no pre-treatment. Non-cavitating lensectomy with the miCOR lens pen achieved effective fragmentation and extraction in all grades of cataract.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s12886-025-04150-4","type":"journal-article","created":{"date-parts":[[2025,7,1]],"date-time":"2025-07-01T13:19:16Z","timestamp":1751375956000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Micro-interventional pre-treatment for nucleus disassembly in the setting of non-cavitating sonic lensectomy: real-world evidence study in 512 cases"],"prefix":"10.1186","volume":"25","author":[{"given":"Sean","family":"Ianchulev","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elizabeth","family":"Yeu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Edward H.","family":"Hu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gautam","family":"Kamthan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seth","family":"Pantanelli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul","family":"Singh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Farrell","family":"Tyson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,7,1]]},"reference":[{"issue":"10094","key":"4150_CR1","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1016\/S0140-6736(17)30544-5","volume":"390","author":"YC Liu","year":"2017","unstructured":"Liu YC, Wilkins M, Kim T, Malyugin B, Mehta JS, Cataracts. Lancet Lond Engl. 2017;390(10094):600\u201312. https:\/\/doi.org\/10.1016\/S0140-6736(17)30544-5.","journal-title":"Lancet Lond Engl"},{"issue":"3","key":"4150_CR2","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1001\/jamaophthalmol.2015.5322","volume":"134","author":"CY Kauh","year":"2016","unstructured":"Kauh CY, Blachley TS, Lichter PR, Lee PP, Stein JD. Geographic variation in the rate and timing of cataract surgery among US communities. JAMA Ophthalmol. 2016;134(3):267\u201376. https:\/\/doi.org\/10.1001\/jamaophthalmol.2015.5322.","journal-title":"JAMA Ophthalmol"},{"issue":"7","key":"4150_CR3","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1016\/j.jcrs.2018.03.038","volume":"44","author":"GJL Foster","year":"2018","unstructured":"Foster GJL, Allen QB, Ayres BD, et al. Phacoemulsification of the rock-hard dense nuclear cataract: options and recommendations. J Cataract Refract Surg. 2018;44(7):905\u201316. https:\/\/doi.org\/10.1016\/j.jcrs.2018.03.038.","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"4150_CR4","first-page":"58","volume":"113","author":"G Davis","year":"2016","unstructured":"Davis G. The evolution of cataract surgery. Mo Med. 2016;113(1):58\u201362.","journal-title":"Mo Med"},{"issue":"3","key":"4150_CR5","doi-asserted-by":"publisher","first-page":"24","DOI":"10.1167\/tvst.11.3.24","volume":"11","author":"L Feng","year":"2022","unstructured":"Feng L, Zhao F, Ke X, Zhao J, Shi M. Correlation between degree of Lens opacity and the phacoemulsification energy parameters using different imaging methods in Age-Related cataract. Transl Vis Sci Technol. 2022;11(3):24. https:\/\/doi.org\/10.1167\/tvst.11.3.24.","journal-title":"Transl Vis Sci Technol"},{"issue":"10","key":"4150_CR6","doi-asserted-by":"publisher","first-page":"1402","DOI":"10.1016\/j.jcrs.2016.08.014","volume":"42","author":"DB Kim","year":"2016","unstructured":"Kim DB. Double-chop: Modified-chop technique eliminating ultrasonic energy and vacuum for lens fragmentation. J Cataract Refract Surg. 2016;42(10):1402\u20137. https:\/\/doi.org\/10.1016\/j.jcrs.2016.08.014.","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"4150_CR7","doi-asserted-by":"publisher","first-page":"1162","DOI":"10.1177\/1120672120905311","volume":"30","author":"AW Harb","year":"2020","unstructured":"Harb AW, Sadiq SN. Tilt-and-crush: A safe, effective and energy-saving technique for soft cataract removal. Eur J Ophthalmol. 2020;30(5):1162\u20137. https:\/\/doi.org\/10.1177\/1120672120905311.","journal-title":"Eur J Ophthalmol"},{"issue":"9","key":"4150_CR8","doi-asserted-by":"publisher","first-page":"3081","DOI":"10.1007\/s10792-021-01872-4","volume":"41","author":"N Miyamoto","year":"2021","unstructured":"Miyamoto N, Kiritoshi S, Akamime R, Akimoto M. Two-hole assisted phaco-chop technique: a more efficient method for safe nucleofractis vertical chopping. Int Ophthalmol. 2021;41(9):3081\u20136. https:\/\/doi.org\/10.1007\/s10792-021-01872-4.","journal-title":"Int Ophthalmol"},{"issue":"6","key":"4150_CR9","doi-asserted-by":"publisher","first-page":"CD010735","DOI":"10.1002\/14651858.CD010735.pub3","volume":"6","author":"A Narayan","year":"2023","unstructured":"Narayan A, Evans JR, O\u2019Brart D, Bunce C, Gore DM, Day AC. Laser-assisted cataract surgery versus standard ultrasound phacoemulsification cataract surgery. Cochrane Database Syst Rev. 2023;6(6):CD010735. https:\/\/doi.org\/10.1002\/14651858.CD010735.pub3.","journal-title":"Cochrane Database Syst Rev"},{"key":"4150_CR10","doi-asserted-by":"publisher","first-page":"1535","DOI":"10.2147\/OPTH.S463525","volume":"18","author":"J Guedes","year":"2024","unstructured":"Guedes J, Pereira SF, Amaral DC, et al. Phaco-Chop versus Divide-and-Conquer in patients who underwent cataract surgery: A systematic review and Meta-Analysis. Clin Ophthalmol Auckl NZ. 2024;18:1535\u201346. https:\/\/doi.org\/10.2147\/OPTH.S463525.","journal-title":"Clin Ophthalmol Auckl NZ"},{"issue":"3","key":"4150_CR11","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1016\/j.optom.2021.05.002","volume":"15","author":"V Galvis","year":"2022","unstructured":"Galvis V, Escaf LC, Escaf LJ, et al. Visual and satisfaction results with implantation of the trifocal Panoptix\u00ae intraocular lens in cataract surgery. J Optom. 2022;15(3):219\u201327. https:\/\/doi.org\/10.1016\/j.optom.2021.05.002.","journal-title":"J Optom"},{"key":"4150_CR12","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1016\/j.ajo.2023.01.024","volume":"251","author":"M Karam","year":"2023","unstructured":"Karam M, Alkhowaiter N, Alkhabbaz A, et al. Extended depth of focus versus trifocal for intraocular Lens implantation: an updated systematic review and Meta-Analysis. Am J Ophthalmol. 2023;251:52\u201370. https:\/\/doi.org\/10.1016\/j.ajo.2023.01.024.","journal-title":"Am J Ophthalmol"},{"issue":"1","key":"4150_CR13","doi-asserted-by":"publisher","first-page":"CD012648","DOI":"10.1002\/14651858.CD012648.pub3","volume":"1","author":"D Zamora-de La Cruz","year":"2023","unstructured":"Zamora-de La Cruz D, Bartlett J, Gutierrez M, Ng SM. Trifocal intraocular lenses versus bifocal intraocular lenses after cataract extraction among participants with presbyopia. Cochrane Database Syst Rev. 2023;1(1):CD012648. https:\/\/doi.org\/10.1002\/14651858.CD012648.pub3.","journal-title":"Cochrane Database Syst Rev"},{"issue":"12","key":"4150_CR14","doi-asserted-by":"publisher","first-page":"1053","DOI":"10.3928\/1081597X-20091117-04","volume":"25","author":"Z Nagy","year":"2009","unstructured":"Nagy Z, Takacs A, Filkorn T, Sarayba M. Initial clinical evaluation of an intraocular femtosecond laser in cataract surgery. J Refract Surg Thorofare NJ 1995. 2009;25(12):1053\u201360. https:\/\/doi.org\/10.3928\/1081597X-20091117-04.","journal-title":"J Refract Surg Thorofare NJ 1995"},{"key":"4150_CR15","doi-asserted-by":"publisher","unstructured":"Sun H, Fritz A, Dr\u00f6ge G, Neuhann T, Bille JF. Femtosecond-Laser-Assisted cataract surgery (FLACS). High [internet]esolution imaging in microscopy and ophthalmology: [internet]ew frontiers in biomedical optics [Internet]. Springer; 2019. https:\/\/doi.org\/10.1007\/978-3-030-16638-0_14.","DOI":"10.1007\/978-3-030-16638-0_14"},{"issue":"2","key":"4150_CR16","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/j.survophthal.2015.09.002","volume":"61","author":"DS Grewal","year":"2016","unstructured":"Grewal DS, Schultz T, Basti S, Dick HB. Femtosecond laser-assisted cataract surgery\u2013current status and future directions. Surv Ophthalmol. 2016;61(2):103\u201331. https:\/\/doi.org\/10.1016\/j.survophthal.2015.09.002.","journal-title":"Surv Ophthalmol"},{"issue":"12","key":"4150_CR17","doi-asserted-by":"publisher","first-page":"4300","DOI":"10.4103\/ijo.IJO_802_22","volume":"70","author":"S Medhi","year":"2022","unstructured":"Medhi S, Senthil Prasad R, Pai A, et al. Clinical outcomes of femtosecond laser-assisted cataract surgery versus conventional phacoemulsification: A retrospective study in a tertiary eye care center in South India. Indian J Ophthalmol. 2022;70(12):4300\u20135. https:\/\/doi.org\/10.4103\/ijo.IJO_802_22.","journal-title":"Indian J Ophthalmol"},{"issue":"4","key":"4150_CR18","doi-asserted-by":"publisher","first-page":"72","DOI":"10.3390\/vision6040072","volume":"6","author":"A Baldascino","year":"2022","unstructured":"Baldascino A, Carl\u00e0 MM, Giannuzzi F, et al. Femtosecond Laser-Assisted cataract surgery: analysis of surgical phases and comparison with standard phacoemulsification in uncomplicated cataracts. Vis Basel Switz. 2022;6(4):72. https:\/\/doi.org\/10.3390\/vision6040072.","journal-title":"Vis Basel Switz"},{"key":"4150_CR19","doi-asserted-by":"publisher","unstructured":"Kp R, Gu JK. Effectiveness and safety of femtosecond laser-assisted lens fragmentation and anterior capsulotomy versus the manual technique in cataract surgery. J Cataract Refract Surg. 2013;39(9). https:\/\/doi.org\/10.1016\/j.jcrs.2013.05.035.","DOI":"10.1016\/j.jcrs.2013.05.035"},{"key":"4150_CR20","doi-asserted-by":"publisher","unstructured":"Hb D, I CH. Intraindividual capsular bag shrinkage comparing standard and laser-assisted cataract surgery. J Refract Surg Thorofare NJ 1995. 2014;30(4). https:\/\/doi.org\/10.3928\/1081597X-20140320-01.","DOI":"10.3928\/1081597X-20140320-01"},{"key":"4150_CR21","doi-asserted-by":"publisher","unstructured":"Jcg C, Cb M, Pvbds S, et al. Comparison of endothelial cell loss in diabetic patients after conventional phacoemulsification and femtosecond laser-assisted cataract surgery. BMC Ophthalmol. 2023;23(1). https:\/\/doi.org\/10.1186\/s12886-023-02923-3.","DOI":"10.1186\/s12886-023-02923-3"},{"issue":"4","key":"4150_CR22","doi-asserted-by":"publisher","first-page":"360","DOI":"10.1016\/j.survophthal.2015.02.002","volume":"60","author":"BH Feldman","year":"2015","unstructured":"Feldman BH. Femtosecond laser will not be a standard method for cataract extraction ten years from now. Surv Ophthalmol. 2015;60(4):360\u20135. https:\/\/doi.org\/10.1016\/j.survophthal.2015.02.002.","journal-title":"Surv Ophthalmol"},{"issue":"10219","key":"4150_CR23","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1016\/S0140-6736(19)32481-X","volume":"395","author":"C Schweitzer","year":"2020","unstructured":"Schweitzer C, Brezin A, Cochener B, et al. Femtosecond laser-assisted versus phacoemulsification cataract surgery (FEMCAT): a multicentre participant-masked randomised superiority and cost-effectiveness trial. Lancet Lond Engl. 2020;395(10219):212\u201324. https:\/\/doi.org\/10.1016\/S0140-6736(19)32481-X.","journal-title":"Lancet Lond Engl"},{"issue":"8","key":"4150_CR24","doi-asserted-by":"publisher","first-page":"1012","DOI":"10.1016\/j.ophtha.2020.02.028","volume":"127","author":"AC Day","year":"2020","unstructured":"Day AC, Burr JM, Bennett K, et al. Femtosecond Laser-Assisted cataract surgery versus phacoemulsification cataract surgery (FACT): A randomized noninferiority trial. Ophthalmology. 2020;127(8):1012\u20139. https:\/\/doi.org\/10.1016\/j.ophtha.2020.02.028.","journal-title":"Ophthalmology"},{"key":"4150_CR25","doi-asserted-by":"publisher","first-page":"2391","DOI":"10.2147\/OPTH.S370290","volume":"16","author":"EH Hu","year":"2022","unstructured":"Hu EH, Buie T, Jensen RJ, Wu D, Pamnani RD. Comparative study of safety outcomes following nucleus disassembly with and without the MiLOOP Lens fragmentation device during cataract surgery. Clin Ophthalmol Auckl NZ. 2022;16:2391\u2013401. https:\/\/doi.org\/10.2147\/OPTH.S370290.","journal-title":"Clin Ophthalmol Auckl NZ"},{"issue":"4","key":"4150_CR26","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1016\/j.jfo.2017.11.011","volume":"41","author":"Y Zhao","year":"2018","unstructured":"Zhao Y, Yang K, Li J, Zhu S. Comparison between the prechopping method with a reverse chopper and the routine stop-and-chop method in treating cataract with grade IV hard nucleus. J Fr Ophtalmol. 2018;41(4):315\u201320. https:\/\/doi.org\/10.1016\/j.jfo.2017.11.011.","journal-title":"J Fr Ophtalmol"},{"issue":"1","key":"4150_CR27","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1186\/s12886-022-02392-0","volume":"22","author":"J Zhao","year":"2022","unstructured":"Zhao J, Li Z, Liu Y, Han X, Huang S. Application of prechop technique in phacoemulsification for cataract patients with highly liquefied vitreous: a retrospective study. BMC Ophthalmol. 2022;22(1):167. https:\/\/doi.org\/10.1186\/s12886-022-02392-0.","journal-title":"BMC Ophthalmol"},{"issue":"2","key":"4150_CR28","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1136\/bjophthalmol-2017-311766","volume":"103","author":"T Ianchulev","year":"2019","unstructured":"Ianchulev T, Chang DF, Koo E, et al. Microinterventional endocapsular nucleus disassembly: novel technique and results of first-in-human randomised controlled study. Br J Ophthalmol. 2019;103(2):176\u201380. https:\/\/doi.org\/10.1136\/bjophthalmol-2017-311766.","journal-title":"Br J Ophthalmol"},{"key":"4150_CR29","doi-asserted-by":"publisher","unstructured":"Ianchulev S, Yeu E, Hu EH, et al. First in-human clinical performance of a novel non-cavitating hand-held lensectomy system in 665 consecutive cataract surgeries. J Cataract Refract Surg Published Online March. 2024;22. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001446.","DOI":"10.1097\/j.jcrs.0000000000001446"},{"key":"4150_CR30","doi-asserted-by":"publisher","first-page":"1095","DOI":"10.2147\/OPTH.S105065","volume":"10","author":"J Zacharias","year":"2016","unstructured":"Zacharias J. Laboratory assessment of thermal characteristics of three phacoemulsification tip designs operated using torsional ultrasound. Clin Ophthalmol Auckl NZ. 2016;10:1095\u2013101. https:\/\/doi.org\/10.2147\/OPTH.S105065.","journal-title":"Clin Ophthalmol Auckl NZ"},{"issue":"6","key":"4150_CR31","doi-asserted-by":"publisher","first-page":"831","DOI":"10.1001\/archopht.1993.01090060119035","volume":"111","author":"LT Chylack","year":"1993","unstructured":"Chylack LT, Wolfe JK, Singer DM, et al. The Lens opacities classification system III. The longitudinal study of cataract study group. Arch Ophthalmol Chic Ill 1960. 1993;111(6):831\u20136. https:\/\/doi.org\/10.1001\/archopht.1993.01090060119035.","journal-title":"Arch Ophthalmol Chic Ill 1960"},{"issue":"1","key":"4150_CR32","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1007\/s10792-021-02014-6","volume":"42","author":"M Shekhar","year":"2022","unstructured":"Shekhar M, Choudhury P, Ramya G, Sankarananthan R, Balagiri S, Wijesinghe HK. Cataract surgery risk stratification in phacoemulsification and manual small incision cataract surgery in a teaching hospital. Int Ophthalmol. 2022;42(1):201\u20139. https:\/\/doi.org\/10.1007\/s10792-021-02014-6.","journal-title":"Int Ophthalmol"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-025-04150-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-025-04150-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-025-04150-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,2]],"date-time":"2025-07-02T01:05:35Z","timestamp":1751418335000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-025-04150-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,1]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["4150"],"URL":"https:\/\/doi.org\/10.1186\/s12886-025-04150-4","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,1]]},"assertion":[{"value":"13 October 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 May 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study met the criteria under 42 CFR 11.22(b) and was not required to be listed on ClinicalTrials.gov. This retrospective chart review was IRB-approved by WCG IRB (a fully accredited IRB Board). The surgical case logs were collected under full patient confidentiality and data were subsequently anonymized. All research adhered to the tenets of the Declaration of Helsinki.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics\/Ethical approval"}},{"value":"Drs. Elizabeth Yeu, Edward H Hu, Seth Pantanelli, Paul Singh, and Farrell Tyson are consultants for Zeiss. Dr. Sean Ianchulev is the inventor of the miCOR and miLOOP and holds patents for the devices. Dr. Gautam Kamthan has no financial or proprietary interest in any material or method mentioned.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"362"}}