{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T20:33:26Z","timestamp":1757622806805,"version":"3.44.0"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,8,11]],"date-time":"2025-08-11T00:00:00Z","timestamp":1754870400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,8,11]],"date-time":"2025-08-11T00:00:00Z","timestamp":1754870400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100003392","name":"Natural Science Foundation of Fujian Province","doi-asserted-by":"publisher","award":["2023J011582"],"award-info":[{"award-number":["2023J011582"]}],"id":[{"id":"10.13039\/501100003392","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Natural Science Foundation of Xiamen","award":["3502Z202374103"],"award-info":[{"award-number":["3502Z202374103"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"DOI":"10.1186\/s12886-025-04301-7","type":"journal-article","created":{"date-parts":[[2025,8,11]],"date-time":"2025-08-11T12:00:23Z","timestamp":1754913623000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Rescue of a dislocated intraocular lens with silicone tip aspiration: a novel technique"],"prefix":"10.1186","volume":"25","author":[{"given":"Haibo","family":"Li","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiuju","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shuxin","family":"Cai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ranqing","family":"Lin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaoxin","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,8,11]]},"reference":[{"issue":"4","key":"4301_CR1","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1016\/S0161-6420(83)34555-3","volume":"90","author":"WJ Stark","year":"1983","unstructured":"Stark WJ, Worthen DM, Holladay JT, Bath PE, Jacobs ME, Murray GC, McGhee ET, Talbott MW, Shipp MD, Thomas NE, et al. The FDA report on intraocular lenses. Ophthalmology. 1983a;90(4):311\u20137.","journal-title":"Ophthalmology"},{"issue":"1","key":"4301_CR2","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1016\/S0146-2776(81)80100-0","volume":"7","author":"RP Kratz","year":"1981","unstructured":"Kratz RP, Mazzocco TR, Davidson B, Colvard DM. The shearing intraocular lens: a report of 1,000 cases. J Am Intraocul Implant Soc. 1981;7(1):55\u20137.","journal-title":"J Am Intraocul Implant Soc"},{"key":"4301_CR3","first-page":"280","volume":"81","author":"WJ Stark Jr","year":"1983","unstructured":"Stark WJ Jr., Maumenee AE, Datiles M, Fagadau W, Baker CC, Worthen D, Auer C, Klein P, McGhee E, Jacobs ME, et al. Intraocular lenses: complications and visual results. Trans Am Ophthalmol Soc. 1983b;81:280\u2013309.","journal-title":"Trans Am Ophthalmol Soc"},{"issue":"5","key":"4301_CR4","doi-asserted-by":"publisher","first-page":"969","DOI":"10.1016\/j.ophtha.2006.09.017","volume":"114","author":"K Hayashi","year":"2007","unstructured":"Hayashi K, Hirata A, Hayashi H. Possible predisposing factors for in-the-bag and out-of-the-bag intraocular lens dislocation and outcomes of intraocular lens exchange surgery. Ophthalmology. 2007;114(5):969\u201375.","journal-title":"Ophthalmology"},{"issue":"6","key":"4301_CR5","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1038\/eye.2015.22","volume":"29","author":"SY Oh","year":"2015","unstructured":"Oh SY, Lee SJ, Park JM. Comparision of surgical outcomes of intraocular lens refixation and intraocular lens exchange with perfluorocarbon liquid and fibrin glue-assisted sutureless scleral fixation. Eye (Lond). 2015;29(6):757\u201363.","journal-title":"Eye (Lond)"},{"issue":"4","key":"4301_CR6","doi-asserted-by":"publisher","first-page":"664","DOI":"10.1016\/j.ophtha.2008.11.018","volume":"116","author":"D Davis","year":"2009","unstructured":"Davis D, Brubaker J, Espandar L, Stringham J, Crandall A, Werner L, Mamalis N. Late in-the-bag spontaneous intraocular lens dislocation: evaluation of 86 consecutive cases. Ophthalmology. 2009;116(4):664\u201370.","journal-title":"Ophthalmology"},{"issue":"5","key":"4301_CR7","doi-asserted-by":"publisher","first-page":"929","DOI":"10.1016\/j.jcrs.2014.08.037","volume":"41","author":"E Liu","year":"2015","unstructured":"Liu E, Cole S, Werner L, Hengerer F, Mamalis N, Kohnen T. Pathologic evidence of pseudoexfoliation in cases of in-the-bag intraocular lens subluxation or dislocation. J Cataract Refract Surg. 2015;41(5):929\u201335.","journal-title":"J Cataract Refract Surg"},{"issue":"7","key":"4301_CR8","doi-asserted-by":"publisher","first-page":"1055","DOI":"10.1016\/S0161-6420(13)31541-3","volume":"100","author":"H Lewis","year":"1993","unstructured":"Lewis H, Sanchez G. The use of perfluorocarbon liquids in the repositioning of posteriorly dislocated intraocular lenses. Ophthalmology. 1993;100(7):1055\u20139.","journal-title":"Ophthalmology"},{"issue":"3","key":"4301_CR9","doi-asserted-by":"publisher","first-page":"334","DOI":"10.1016\/j.jcrs.2013.01.022","volume":"39","author":"SJ Lee","year":"2013","unstructured":"Lee SJ, Kim IG, Park JM. Management of posteriorly dislocated crystalline lens with perfluorocarbon liquid and fibrin glue-assisted scleral-fixated intraocular lens implantation. J Cataract Refract Surg. 2013;39(3):334\u20138.","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"4301_CR10","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1016\/j.jcrs.2003.11.024","volume":"30","author":"H Bhattacharjee","year":"2004","unstructured":"Bhattacharjee H, Bhattacharjee K, Das D, Jain PK, Chakraborty D, Deka S. Management of a posteriorly dislocated endocapsular tension ring and a foldable acrylic intraocular lens. J Cataract Refract Surg. 2004;30(1):243\u20136.","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"4301_CR11","doi-asserted-by":"publisher","first-page":"1807","DOI":"10.1097\/IAE.0000000000003225","volume":"43","author":"LT Yip","year":"2023","unstructured":"Yip LT, Fong A, Tsang CW. Novel technique for 27-gauge forceps-assisted transscleral refixation of the dislocated CZ70BD intraocular lens. Retina. 2023;43(10):1807\u201310.","journal-title":"Retina"},{"key":"4301_CR12","doi-asserted-by":"publisher","first-page":"315","DOI":"10.2147\/OPTH.S445244","volume":"18","author":"BJ Iranipour","year":"2024","unstructured":"Iranipour BJ, Rosander JH, Zetterberg M. Visual improvement and Lowered intraocular pressure after surgical management of In-The-Bag intraocular lens dislocation and aphakia correction; retrospective analysis of scleral suturing versus retropupillary fixated Iris-Claw intraocular lens during a 5-Year period. Clin Ophthalmol. 2024;18:315\u201324.","journal-title":"Clin Ophthalmol"},{"key":"4301_CR13","doi-asserted-by":"crossref","unstructured":"Icoz M, Usta SA. Modified double-flanged technique in the management of dislocated posterior intraocular lenses. Graefes Arch Clin Exp Ophthalmol. Published online March 12, 2025.","DOI":"10.1007\/s00417-025-06795-9"},{"issue":"2","key":"4301_CR14","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1016\/j.jcrs.2012.12.004","volume":"39","author":"JL Olson","year":"2013","unstructured":"Olson JL, Velez-Montoya R, Erlanger M, Mackenzie D. Management of a dislocated intraocular lens with a suction-based grasping tool. J Cataract Refract Surg. 2013;39(2):154\u20137.","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"4301_CR15","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1186\/s40942-024-00562-4","volume":"10","author":"L Michaels","year":"2024","unstructured":"Michaels L, Moussa G, Ziaei H, Davies A. Dislocated 4-haptic intraocular lens rescue with Gore-Tex suture scleral re-fixation. Int J Retina Vitreous. 2024;10(1):47.","journal-title":"Int J Retina Vitreous"},{"issue":"7","key":"4301_CR16","doi-asserted-by":"publisher","first-page":"910","DOI":"10.1136\/bjophthalmol-2013-304700","volume":"98","author":"A Agarwal","year":"2014","unstructured":"Agarwal A, Narang P, Agarwal A, Kumar DA. Sleeveless-extrusion cannula for levitation of dislocated intraocular lens. Br J Ophthalmol. 2014;98(7):910\u20134.","journal-title":"Br J Ophthalmol"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-025-04301-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-025-04301-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-025-04301-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,8]],"date-time":"2025-09-08T22:48:05Z","timestamp":1757371685000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-025-04301-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,11]]},"references-count":16,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["4301"],"URL":"https:\/\/doi.org\/10.1186\/s12886-025-04301-7","relation":{},"ISSN":["1471-2415"],"issn-type":[{"type":"electronic","value":"1471-2415"}],"subject":[],"published":{"date-parts":[[2025,8,11]]},"assertion":[{"value":"28 April 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 August 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures were approved by the hospital ethics committee of Xiamen Eye Center of Xiamen University and informed consent forms were signed by the patients.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"453"}}