{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T13:24:35Z","timestamp":1783949075807,"version":"3.55.0"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,9,2]],"date-time":"2025-09-02T00:00:00Z","timestamp":1756771200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,9,2]],"date-time":"2025-09-02T00:00:00Z","timestamp":1756771200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Manual and digital-assisted marking are the two main marking methods used for toric intraocular lens (IOL) in cataract surgery. However, there is a lack of consensus regarding the consistency in accuracy for these two methods. This meta-analysis aimed to compare and evaluate the accuracy of digital and manual marking techniques for toric IOL alignment during cataract surgery.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>A comprehensive search was conducted using PubMed, Embase, and Cochrane Library databases to identify studies that compared the effectiveness of these two techniques in positioning toric IOLs. The primary outcome measures included postoperative uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), mean deviation from target-induced astigmatism, and postoperative IOL misalignment. Statistical analyses were performed using RevMan 5.3 software.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>This meta-analysis included four randomized controlled trials and three retrospective studies comprising 197 eyes in the digital marking group and 206 eyes in the manual marking group for comparative analyses. The statistical meta-analysis indicated no significant differences in postoperative UDVA (logMAR) between the two groups (<jats:italic>P<\/jats:italic>\u2009=\u20090.69). Additionally, the meta-analysis showed no significant differences in postoperative CDVA (logMAR) between the two groups (<jats:italic>P<\/jats:italic>\u2009=\u20090.29). However, the meta-analysis findings highlighted a significant reduction in the degree of postoperative IOL misalignment in the digital marking group compared to the manual marking group (<jats:italic>P<\/jats:italic>\u2009=\u20090.0001).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>The results of this meta-analysis offer compelling evidence that the digital marking technique resulted in a lower postoperative IOL misalignment rate than that for the traditional manual marking technique. Both marking methodologies were encouraged in clinical practice because of their effectiveness and accuracy; although, the digital marking technique was generally preferred and highly recommended.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Trial registration<\/jats:title>\n            <jats:p>The protocol of this study was registered in PROSPERO (registration ID: CRD420251045237).<\/jats:p>\n          <\/jats:sec>","DOI":"10.1186\/s12886-025-04329-9","type":"journal-article","created":{"date-parts":[[2025,9,2]],"date-time":"2025-09-02T09:25:36Z","timestamp":1756805136000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Digital marking versus manual marking technique for toric intraocular lens alignment: a meta-analysis"],"prefix":"10.1186","volume":"25","author":[{"given":"Ji-guo","family":"Yu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ting","family":"Ye","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi","family":"Xiang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,9,2]]},"reference":[{"key":"4329_CR1","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1186\/s12886-017-0450-2","volume":"17","author":"JG Yu","year":"2017","unstructured":"Yu JG, Zhong J, Mei ZM, Zhao F, Tao N, Xiang Y. Evaluation of biometry and corneal astigmatism in cataract surgery patients from central China. BMC Ophthalmol. 2017;17:56.","journal-title":"BMC Ophthalmol"},{"key":"4329_CR2","doi-asserted-by":"publisher","first-page":"11514","DOI":"10.1038\/s41598-021-91028-2","volume":"11","author":"Y Jiang","year":"2021","unstructured":"Jiang Y, Qin Y, Bu S, Zhang H, Zhang X, Tian F. Distribution and internal correlations of corneal astigmatism in cataract patients. Sci Rep. 2021;11:11514.","journal-title":"Sci Rep"},{"key":"4329_CR3","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1016\/j.jcrs.2010.09.022","volume":"37","author":"JS Wolffsohn","year":"2011","unstructured":"Wolffsohn JS, Bhogal G, Shah S. Effect of uncorrected astigmatism on vision. J Cataract Refract Surg. 2011;37:454\u201360.","journal-title":"J Cataract Refract Surg"},{"key":"4329_CR4","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1016\/j.ophtha.2015.10.002","volume":"123","author":"L Kessel","year":"2016","unstructured":"Kessel L, Andresen J, Tendal B, Erngaard D, Flesner P, Hjortdal J. Toric intraocular lenses in the correction of astigmatism during cataract surgery: A systematic review and Meta-analysis. Ophthalmology. 2016;123:275\u201386.","journal-title":"Ophthalmology"},{"key":"4329_CR5","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1007\/s10792-016-0250-3","volume":"37","author":"H Bayramlar","year":"2017","unstructured":"Bayramlar H, Dag Y, Karadag R, Cakici O. An easy and practical method for toric intraocular lens implantation: marking corneal astigmatic axis at slit-lamp. Int Ophthalmol. 2017;37:179\u201384.","journal-title":"Int Ophthalmol"},{"key":"4329_CR6","doi-asserted-by":"publisher","first-page":"559","DOI":"10.4103\/0301-4738.191486","volume":"64","author":"S Bhandari","year":"2016","unstructured":"Bhandari S, Nath M. Anterior stromal puncture with staining: A modified technique for preoperative reference corneal marking for toric lenses and its retrospective analyses. Indian J Ophthalmol. 2016;64:559\u201362.","journal-title":"Indian J Ophthalmol"},{"key":"4329_CR7","doi-asserted-by":"publisher","first-page":"e1618","DOI":"10.1097\/MD.0000000000001618","volume":"94","author":"AH Elhofi","year":"2015","unstructured":"Elhofi AH, Helaly HA. Comparison between digital and manual marking for toric intraocular lenses: A randomized trial. Med (Baltim). 2015;94:e1618.","journal-title":"Med (Baltim)"},{"key":"4329_CR8","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1016\/j.jcrs.2017.03.041","volume":"43","author":"VSC Webers","year":"2017","unstructured":"Webers VSC, Bauer NJC, Visser N, Berendschot T, van den Biggelaar F, Nuijts R. Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery. J Cataract Refract Surg. 2017;43:781\u20138.","journal-title":"J Cataract Refract Surg"},{"key":"4329_CR9","doi-asserted-by":"publisher","first-page":"3020","DOI":"10.4103\/ijo.IJO_465_20","volume":"68","author":"SK Kodavoor","year":"2020","unstructured":"Kodavoor SK, Divya J, Dandapani R, Ramamurthy C, Ramamurthy S, Sachdev G. Randomized trial comparing visual outcomes of toric intraocular lens implantation using manual and digital marker. Indian J Ophthalmol. 2020;68:3020\u20134.","journal-title":"Indian J Ophthalmol"},{"key":"4329_CR10","first-page":"108","volume":"5","author":"B Kose","year":"2020","unstructured":"Kose B, Erdogan H. Comparison of toric intraocular lens alignment using Image-Guided system and manual marking technique. Beyoglu Eye J. 2020;5:108\u201313.","journal-title":"Beyoglu Eye J"},{"key":"4329_CR11","doi-asserted-by":"publisher","first-page":"d5928","DOI":"10.1136\/bmj.d5928","volume":"343","author":"JP Higgins","year":"2011","unstructured":"Higgins JP, Altman DG, G\u00f8tzsche PC, J\u00fcni P, Moher D, Oxman AD, et al. The Cochrane collaboration\u2019s tool for assessing risk of bias in randomised trials. BMJ. 2011;343:d5928.","journal-title":"BMJ"},{"key":"4329_CR12","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1007\/s10654-010-9491-z","volume":"25","author":"A Stang","year":"2010","unstructured":"Stang A. Critical evaluation of the Newcastle-Ottawa scale for the assessment of the quality of nonrandomized studies in meta-analyses. Eur J Epidemiol. 2010;25:603\u20135.","journal-title":"Eur J Epidemiol"},{"key":"4329_CR13","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1186\/s12886-022-02548-y","volume":"22","author":"N Ding","year":"2022","unstructured":"Ding N, Wang X, Song X. Digital versus slit-beam marking for toric intraocular lenses in cataract surgery. BMC Ophthalmol. 2022;22:323.","journal-title":"BMC Ophthalmol"},{"key":"4329_CR14","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1080\/02713683.2022.2159981","volume":"48","author":"L Feldhaus","year":"2023","unstructured":"Feldhaus L, Mayer WJ, Dirisamer M, Kassumeh S, Shajari M, Priglinger SG, et al. Comparison of visual and refractive outcome between two methods of corneal marking for toric implantable collamer lenses (TICL) in Phakic eyes. Curr Eye Res. 2023;48:357\u201364.","journal-title":"Curr Eye Res"},{"key":"4329_CR15","doi-asserted-by":"publisher","first-page":"1281","DOI":"10.1016\/j.jcrs.2017.07.030","volume":"43","author":"WJ Mayer","year":"2017","unstructured":"Mayer WJ, Kreutzer T, Dirisamer M, Kern C, Kortuem K, Vounotrypidis E, et al. Comparison of visual outcomes, alignment accuracy, and surgical time between 2 methods of corneal marking for toric intraocular lens implantation. J Cataract Refract Surg. 2017;43:1281\u20136.","journal-title":"J Cataract Refract Surg"},{"key":"4329_CR16","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1097\/j.jcrs.0000000000001553","volume":"51","author":"W List","year":"2025","unstructured":"List W, Dirisamer M, Mayer WJ, Shajari M, Glatz W, Gran J, et al. Digital vs manual axis marking for toric Phakic intraocular lens alignment: prospective randomized intraindividual trial. J Cataract Refract Surg. 2025;51:23\u201330.","journal-title":"J Cataract Refract Surg"},{"key":"4329_CR17","doi-asserted-by":"publisher","first-page":"2061","DOI":"10.1016\/j.jcrs.2010.06.066","volume":"36","author":"H Jin","year":"2010","unstructured":"Jin H, Limberger IJ, Ehmer A, Guo H, Auffarth GU. Impact of axis misalignment of toric intraocular lenses on refractive outcomes after cataract surgery. J Cataract Refract Surg. 2010;36:2061\u201372.","journal-title":"J Cataract Refract Surg"},{"key":"4329_CR18","doi-asserted-by":"publisher","first-page":"482","DOI":"10.3928\/1081597X-20170504-02","volume":"33","author":"AS Hura","year":"2017","unstructured":"Hura AS, Osher RH. Comparing the zeiss Callisto eye and the Alcon Verion image guided system toric lens alignment technologies. J Refract Surg. 2017;33:482\u20137.","journal-title":"J Refract Surg"},{"key":"4329_CR19","first-page":"1","volume":"5","author":"B Kose","year":"2020","unstructured":"Kose B, Albayrak S. Results of Callisto eye system in toric intraocular lens alignment. Beyoglu Eye J. 2020;5:1\u20134.","journal-title":"Beyoglu Eye J"},{"key":"4329_CR20","doi-asserted-by":"publisher","first-page":"667","DOI":"10.18240\/ijo.2020.04.21","volume":"13","author":"S Emerah","year":"2020","unstructured":"Emerah S. Evaluation of axis alignment and refractive results of toric Phakic IOL using image-guided system. Int J Ophthalmol. 2020;13:667\u201370.","journal-title":"Int J Ophthalmol"},{"key":"4329_CR21","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.ajo.2021.05.028","volume":"231","author":"S Yang","year":"2021","unstructured":"Yang S, Byun YS, Kim HS, Chung SH. Comparative accuracy of Barrett toric calculator with and without posterior corneal astigmatism measurements and the Kane toric formula. Am J Ophthalmol. 2021;231:48\u201357.","journal-title":"Am J Ophthalmol"},{"key":"4329_CR22","doi-asserted-by":"publisher","first-page":"1895","DOI":"10.1016\/j.jcrs.2011.04.036","volume":"37","author":"A Felipe","year":"2011","unstructured":"Felipe A, Artigas JM, D\u00edez-Ajenjo A, Garc\u00eda-Domene C, Alcocer P. Residual astigmatism produced by toric intraocular lens rotation. J Cataract Refract Surg. 2011;37:1895\u2013901.","journal-title":"J Cataract Refract Surg"},{"key":"4329_CR23","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.4103\/ijo.IJO_810_17","volume":"65","author":"M Kaur","year":"2017","unstructured":"Kaur M, Shaikh F, Falera R, Titiyal JS. Optimizing outcomes with toric intraocular lenses. Indian J Ophthalmol. 2017;65:1301\u201313.","journal-title":"Indian J Ophthalmol"},{"key":"4329_CR24","doi-asserted-by":"publisher","first-page":"1232","DOI":"10.1016\/j.jcrs.2014.09.045","volume":"41","author":"YJ Woo","year":"2015","unstructured":"Woo YJ, Lee H, Kim HS, Kim EK, Seo KY, Kim TI. Comparison of 3 marking techniques in preoperative assessment of toric intraocular lenses using a wavefront aberrometer. J Cataract Refract Surg. 2015;41:1232\u201340.","journal-title":"J Cataract Refract Surg"},{"key":"4329_CR25","doi-asserted-by":"publisher","first-page":"4135","DOI":"10.2147\/OPTH.S277945","volume":"14","author":"T Ohashi","year":"2020","unstructured":"Ohashi T, Kojima T. Comparison of the orientation of the corneal steep meridian determined by Image-Guided system and manual method in the same eye. Clin Ophthalmol. 2020;14:4135\u201344.","journal-title":"Clin Ophthalmol"},{"key":"4329_CR26","doi-asserted-by":"publisher","first-page":"1535","DOI":"10.1097\/j.jcrs.0000000000000688","volume":"47","author":"E Barber\u00e1-Loustaunau","year":"2021","unstructured":"Barber\u00e1-Loustaunau E, Basanta I, V\u00e1zquez J, Dur\u00e1n P, Costa M, Cou\u00f1ago F, et al. Time-efficiency assessment of guided toric intraocular lens cataract surgery: pilot study. J Cataract Refract Surg. 2021;47:1535\u201341.","journal-title":"J Cataract Refract Surg"},{"key":"4329_CR27","doi-asserted-by":"publisher","first-page":"1234","DOI":"10.1016\/j.jcrs.2019.04.009","volume":"45","author":"RM Varsits","year":"2019","unstructured":"Varsits RM, Hirnschall N, D\u00f6ller B, Findl O. Evaluation of an intraoperative toric intraocular lens alignment system using an image-guided system. J Cataract Refract Surg. 2019;45:1234\u20138.","journal-title":"J Cataract Refract Surg"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-025-04329-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-025-04329-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-025-04329-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,10]],"date-time":"2025-09-10T04:15:32Z","timestamp":1757477732000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-025-04329-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,2]]},"references-count":27,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["4329"],"URL":"https:\/\/doi.org\/10.1186\/s12886-025-04329-9","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,2]]},"assertion":[{"value":"13 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 September 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"499"}}