{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,17]],"date-time":"2025-09-17T02:15:09Z","timestamp":1758075309094,"version":"3.44.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,9,16]],"date-time":"2025-09-16T00:00:00Z","timestamp":1757980800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,9,16]],"date-time":"2025-09-16T00:00:00Z","timestamp":1757980800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"DOI":"10.1186\/s12886-025-04340-0","type":"journal-article","created":{"date-parts":[[2025,9,16]],"date-time":"2025-09-16T10:23:40Z","timestamp":1758018220000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["A case series study of laser refractive corneal surgery assisted by a virtual postoperative corneal simulation"],"prefix":"10.1186","volume":"25","author":[{"given":"Jerry","family":"Tan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Samuel","family":"Arba Mosquera","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,9,16]]},"reference":[{"issue":"1","key":"4340_CR1","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1016\/s0886-3350(88)80063-4","volume":"14","author":"CR Munnerlyn","year":"1988","unstructured":"Munnerlyn CR, Koons SJ, Marshall J. Photorefractive keratectomy: a technique for laser refractive surgery. J Cataract Refract Surg. 1988;14(1):46\u201352. https:\/\/doi.org\/10.1016\/s0886-3350(88)80063-4.","journal-title":"J Cataract Refract Surg"},{"issue":"8","key":"4340_CR2","first-page":"1736","volume":"42","author":"D Gatinel","year":"2001","unstructured":"Gatinel D, Hoang-Xuan T, Azar DT. Determination of corneal asphericity after myopia surgery with the excimer laser: a mathematical model. Invest Ophthalmol Vis Sci. 2001;42(8):1736\u201342.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"10","key":"4340_CR3","doi-asserted-by":"publisher","first-page":"708","DOI":"10.3928\/1081597X-20140903-10","volume":"30","author":"D Gatinel","year":"2014","unstructured":"Gatinel D, Azar DT, Dumas L, Malet J. Effect of anterior corneal surface asphericity modification on fourth-order zernike spherical aberrations. J Refract Surg. 2014;30(10):708\u201315. https:\/\/doi.org\/10.3928\/1081597X-20140903-10. (PMID: 25291755).","journal-title":"J Refract Surg"},{"issue":"2","key":"4340_CR4","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1007\/s13246-024-01403-2","volume":"47","author":"MV Mascolini","year":"2024","unstructured":"Mascolini MV, Toniolo I, Carniel EL, Fontanella CG. Ex vivo, in vivo and in silico studies of corneal biomechanics: a systematic review. Phys Eng Sci Med. 2024;47(2):403\u201341. https:\/\/doi.org\/10.1007\/s13246-024-01403-2. (Epub 2024 Apr 10. PMID: 38598066; PMCID: PMC11166853).","journal-title":"Phys Eng Sci Med"},{"issue":"5 Suppl","key":"4340_CR5","doi-asserted-by":"publisher","first-page":"S741","DOI":"10.3928\/1081-597X-20040903-24","volume":"20","author":"S Pieger","year":"2004","unstructured":"Pieger S. Pearls, tips, and tricks for use of the Nidek OPD-scan and FinalFit software. J Refract Surg. 2004;20(5 Suppl):S741-6. https:\/\/doi.org\/10.3928\/1081-597X-20040903-24.","journal-title":"J Refract Surg"},{"issue":"11","key":"4340_CR6","doi-asserted-by":"publisher","first-page":"S829","DOI":"10.3928\/1081597X-20121005-04","volume":"28","author":"J Tan","year":"2012","unstructured":"Tan J, Simon D, Mrochen M, Por YM. Clinical results of topography-based customized ablations for myopia and myopic astigmatism. J Refract Surg. 2012;28(11):S829\u201336. https:\/\/doi.org\/10.3928\/1081597X-20121005-04. (PMID: 23447897).","journal-title":"J Refract Surg"},{"key":"4340_CR7","doi-asserted-by":"publisher","first-page":"3389","DOI":"10.2147\/OPTH.S497131","volume":"18","author":"AL Thananjeyan","year":"2024","unstructured":"Thananjeyan AL, Bala C. Higher-order aberrations following ray trace LASIK and the impact of eye movement on coma. Clin Ophthalmol. 2024;18:3389\u201398. https:\/\/doi.org\/10.2147\/OPTH.S497131.","journal-title":"Clin Ophthalmol"},{"issue":"12","key":"4340_CR8","doi-asserted-by":"publisher","first-page":"e1003","DOI":"10.3928\/1081597X-20241002-01","volume":"40","author":"M Kr\u00e4mer","year":"2024","unstructured":"Kr\u00e4mer M, Charonis A, Arba-Mosquera S. Clipped topography-guided treatments: a different approach to custom corrections. J Refract Surg. 2024;40(12):e1003\u201314. https:\/\/doi.org\/10.3928\/1081597X-20241002-01. (Epub 2024 Dec 1. PMID: 39656250).","journal-title":"J Refract Surg"},{"key":"4340_CR9","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/S0002-9394(14)73521-4","volume":"115","author":"RK Maloney","year":"1993","unstructured":"Maloney RK, Bogan SJ, Waring GO. Determination of corneal image-forming properties from corneal topography. Am J Ophthalmol. 1993;115:31\u201341.","journal-title":"Am J Ophthalmol"},{"issue":"2","key":"4340_CR10","doi-asserted-by":"publisher","first-page":"137","DOI":"10.3928\/1081597X-20080201-03","volume":"24","author":"D de Ortueta","year":"2008","unstructured":"de Ortueta D, Arba-Mosquera S, Baatz H. Topographic changes after hyperopic LASIK with the SCHWIND ESIRIS laser platform. J Refract Surg. 2008;24(2):137\u201344. https:\/\/doi.org\/10.3928\/1081597X-20080201-03. (PMID: 18297937).","journal-title":"J Refract Surg"},{"issue":"1","key":"4340_CR11","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-024-03235-1","volume":"44","author":"L Li","year":"2024","unstructured":"Li L, Xiong L, Wang Z. Comparison of clinical outcomes of a corneal wavefront- and topography-guided platforms for laser in situ keratomileusis on virgin eyes: an expanded cohort study. Int Ophthalmol. 2024;44(1):331. https:\/\/doi.org\/10.1007\/s10792-024-03235-1. (PMID: 39037500; PMCID: PMC11263421).","journal-title":"Int Ophthalmol"},{"issue":"1","key":"4340_CR12","doi-asserted-by":"publisher","first-page":"1124","DOI":"10.1038\/s41598-020-57926-7","volume":"10","author":"D Schiano-Lomoriello","year":"2020","unstructured":"Schiano-Lomoriello D, Bono V, Abicca I, Savini G. Repeatability of anterior segment measurements by optical coherence tomography combined with Placido disk corneal topography in eyes with keratoconus. Sci Rep. 2020;10(1):1124. https:\/\/doi.org\/10.1038\/s41598-020-57926-7. (PMID: 31980662; PMCID: PMC6981210).","journal-title":"Sci Rep"},{"key":"4340_CR13","doi-asserted-by":"publisher","first-page":"3841","DOI":"10.2147\/OPTH.S267091","volume":"14","author":"M Motwani","year":"2020","unstructured":"Motwani M. Analysis and causation of all inaccurate outcomes after wavelight contoura LASIK with LYRA protocol. Clin Ophthalmol. 2020;14:3841\u201354. https:\/\/doi.org\/10.2147\/OPTH.S267091.","journal-title":"Clin Ophthalmol"},{"key":"4340_CR14","doi-asserted-by":"publisher","first-page":"2563","DOI":"10.2147\/OPTH.S423087","volume":"17","author":"M Moshirfar","year":"2023","unstructured":"Moshirfar M, Theis JS, Cha DS, Porter KB, Payne CJ, Hoopes PC. Influence of preoperative parameters on the ratio of keratometric change per diopter of attempted spherical equivalent (\u2206K\/\u2206SEQ) for myopic correction within LASIK, PRK, and SMILE. Clin Ophthalmol. 2023;17:2563\u201373. https:\/\/doi.org\/10.2147\/OPTH.S423087.","journal-title":"Clin Ophthalmol"},{"issue":"4","key":"4340_CR15","doi-asserted-by":"publisher","first-page":"7","DOI":"10.22037\/joos.v7i4.47444","volume":"7","author":"H Mohammad-Rabei","year":"2023","unstructured":"Mohammad-Rabei H, Ghadyani Z, Delfaza S, Feizi S. Visual and refractive outcomes after topographic-guided customized ablation photorefractive keratectomy in keratoconic eyes. J Ophthalmic Optom Sci. 2023;7(4):7\u201311. https:\/\/doi.org\/10.22037\/joos.v7i4.47444.","journal-title":"J Ophthalmic Optom Sci"},{"issue":"4","key":"4340_CR16","doi-asserted-by":"publisher","DOI":"10.3390\/vision6040074","volume":"6","author":"D de Ortueta","year":"2022","unstructured":"de Ortueta D, von R\u00fcden D, Arba-Mosquera S. Refractive effect of epithelial remodelling in myopia after transepithelial photorefractive keratectomy. Vision. 2022;6(4):74. https:\/\/doi.org\/10.3390\/vision6040074.","journal-title":"Vision"},{"issue":"7","key":"4340_CR17","doi-asserted-by":"publisher","first-page":"1541","DOI":"10.1364\/JOSAA.27.001541","volume":"27","author":"A P\u00e9rez-Escudero","year":"2010","unstructured":"P\u00e9rez-Escudero A, Dorronsoro C, Marcos S. Correlation between radius and asphericity in surfaces fitted by conics. J Opt Soc Am A Opt Image Sci Vis. 2010;27(7):1541\u20138. https:\/\/doi.org\/10.1364\/JOSAA.27.001541.","journal-title":"J Opt Soc Am A Opt Image Sci Vis"},{"key":"4340_CR18","unstructured":"Tan J. Reduction of corneal epithelial hyperplasia after Customised Corneal Wavefront-guided LASIK combined with accelerated Crosslinking (LASIK Xtra) for low, moderate and high myopic corrections. Presented at the 39th Congress of the ESCRS in Amsterdam on 8th October 2021 (accessed on 24th Jan 2025: https:\/\/congress.2021.escrs.org\/wp-content\/uploads\/2021\/09\/ESCRS-2021-Free-Paper-Refractive.pdf)."},{"issue":"3","key":"4340_CR19","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1016\/s0002-9394(02)01942-6","volume":"135","author":"D Huang","year":"2003","unstructured":"Huang D, Tang M, Shekhar R. Mathematical model of corneal surface smoothing after laser refractive surgery. Am J Ophthalmol. 2003;135(3):267\u201378. https:\/\/doi.org\/10.1016\/s0002-9394(02)01942-6.","journal-title":"Am J Ophthalmol"},{"issue":"12","key":"4340_CR20","doi-asserted-by":"publisher","first-page":"1659","DOI":"10.1097\/j.jcrs.0000000000000343","volume":"46","author":"S Taneri","year":"2020","unstructured":"Taneri S, Arba-Mosquera S, Rost A, Kie\u00dfler S, Dick HB. Repeatability and reproducibility of manifest refraction. J Cataract Refract Surg. 2020;46(12):1659\u201366. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000343. (PMID: 33259390).","journal-title":"J Cataract Refract Surg"},{"issue":"11","key":"4340_CR21","doi-asserted-by":"publisher","first-page":"e814","DOI":"10.3928\/1081597X-20240917-02","volume":"40","author":"S Taneri","year":"2024","unstructured":"Taneri S, Arba-Mosquera S, F\u00f6rster A, Dick HB. Predictability of keratorefractive lenticule extraction is equal to variance of preoperative manifest refraction measurement. J Refract Surg. 2024;40(11):e814\u201323. https:\/\/doi.org\/10.3928\/1081597X-20240917-02. (Epub 2024 Nov 1. PMID: 39530992).","journal-title":"J Refract Surg"},{"key":"4340_CR22","unstructured":"Nithin Manohar Chowdary Rayudu, Rafael Grytz, William J. Dupps Jr; Prediction of corneal geometric responses to lasik with patient-specific computational modelling. Invest. Ophthalmol. Vis. Sci. 2024;65(7):2059."},{"issue":"6","key":"4340_CR23","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1515\/aot-2021-0039","volume":"10","author":"T Kehrer","year":"2021","unstructured":"Kehrer T, Arba MS. A simple cornea deformation model. Adv Opt Technol. 2021;10(6):433\u201350. https:\/\/doi.org\/10.1515\/aot-2021-0039.","journal-title":"Adv Opt Technol"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-025-04340-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-025-04340-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-025-04340-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,16]],"date-time":"2025-09-16T23:04:09Z","timestamp":1758063849000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcophthalmol.biomedcentral.com\/articles\/10.1186\/s12886-025-04340-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,16]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["4340"],"URL":"https:\/\/doi.org\/10.1186\/s12886-025-04340-0","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,16]]},"assertion":[{"value":"29 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 September 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethics approval was not required due to the retrospective nature of the review chart. The purpose of this clinical research does not represent a clinical investigation. The medical device was used within its intended purpose without any additional invasive or patient burdensome procedures used. Thus, this work does not report any experiments on humans. All methods were carried out in accordance with relevant guidelines and regulations. Informed consent was obtained from all subjects and\/or their legal guardian(s).The evaluated preview ForeSight does not qualify as a medical device. This work is an observational study on previously generated clinical data. Research on anonymous or non-identified data (as in this work) is categorized as \u201cless than minimal risk\u201d since the \u201cprobability of harm or discomfort anticipated in the research is nil or not expected\u201d. Based on the risk categorization, research on anonymous or non-identified data (as in this work) meets the conditions of the guideline from exemption from review by the Ethical Review Board.If the need for ethics approval was deemed unnecessary according to national guidelines ().The work did not require additional consent from subjects, beyond what is already obtained for clinical practice. The work did not pose any risks for subjects beyond those of their routine care. The work did not impose a burden on subjects beyond that experienced in their routine care. The work was not conducted by a person who does not normally have access to the subjects\u2019 records for clinical care. The work did not risk breaching the confidentiality of any individuals\u2019 personal information, beyond that experienced in the provision of routine care. The work did not involve any clinically significant departure from the routine clinical care provided to the subjects. The work did not involve randomization. The work did not involve the use of a control group or a placebo. The work did not gather information about the participant beyond that collected in routine clinical care. The work did not infringe the rights, privacy or professional reputation of health care providers or the institution(s). The work involved only Anonymised Data and as such does not meet the definition of human subjects research, as there is no use of identifiable private information. These studies do not require review and approval by the Domain Specific Review Board.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable. No identifiable information (image, face, name etc.) from the participants is revealed in the submission.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"SAM is employee of SCHWIND eye-tech-solutions.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"502"}}