{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T18:01:06Z","timestamp":1781632866442,"version":"3.54.5"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T00:00:00Z","timestamp":1768780800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,2,11]],"date-time":"2026-02-11T00:00:00Z","timestamp":1770768000000},"content-version":"vor","delay-in-days":23,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>This study aimed to evaluate correlations between corneal optical densitometry (COD) and corneal higher-order aberrations (HOAs).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design<\/jats:title>\n                    <jats:p>A prospective cross-sectional study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A total of 67 participants were enrolled. The Pentacam quantified total COD and corneal HOAs. Coma and trefoil were described using the root mean square (RMS). HOAs measurements, including total HOA, spherical aberration (Z40), vertical coma (Z3-1), horizontal coma (Z31), oblique trefoil (Z3-3), horizontal trefoil (Z33), coma RMS (Z3\u2009\u00b1\u20091 RMS), and trefoil RMS (Z3\u2009\u00b1\u20093 RMS) of the total, anterior, and posterior corneas, were calculated for both the central 4.0\u00a0mm diameter and the central 6.0\u00a0mm diameter zones.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      In the central 4.0\u00a0mm diameter zone, total COD exhibited significant positive correlations with HOA, Z40, and Z3\u2009\u00b1\u20091 RMS of the total cornea, HOA and Z40 of the anterior cornea, as well as Z40 and Z31 of the posterior cornea; in the 6.0\u00a0mm zone, total COD was positively correlated with HOA, Z40, and Z3\u2009\u00b1\u20091 RMS of the total cornea, HOA of the anterior cornea, as well as Z40, Z3-1, Z31, and Z3\u2009\u00b1\u20091 RMS of the posterior cornea (\n                      <jats:italic>P<\/jats:italic>\n                      \u2009&lt;\u20090.05 for each one). Age and COD showed a statistically positive correlation (r\n                      <jats:sub>s<\/jats:sub>\n                      = 0.350,\n                      <jats:italic>P<\/jats:italic>\n                      \u2009=\u20090.004).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>An increase in COD may result in elevated levels of corneal HOAs, particularly including total HOA, spherical aberration, and coma. This increase could potentially compromise the sphericity, symmetry, and regularity of the cornea due to age-related changes in corneal microstructure and composition, even in clinically transparent corneas.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12886-025-04583-x","type":"journal-article","created":{"date-parts":[[2026,1,19]],"date-time":"2026-01-19T08:17:49Z","timestamp":1768810669000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Corneal optical densitometry in transparent corneas and its correlations with corneal higher-order aberrations"],"prefix":"10.1186","volume":"26","author":[{"given":"Ji","family":"Sun","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bin","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ling","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhangyi","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiayu","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenjuan","family":"Wan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Can","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,1,19]]},"reference":[{"issue":"2","key":"4583_CR1","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1016\/j.jcrs.2009.09.026","volume":"36","author":"M Lombardo","year":"2010","unstructured":"Lombardo M, Lombardo G. Wave aberration of human eyes and new descriptors of image optical quality and visual performance. J Cataract Refract Surg. 2010;36(2):313\u201331.","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"4583_CR2","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1007\/s10384-020-00737-0","volume":"64","author":"Y Iwama","year":"2020","unstructured":"Iwama Y, Maeda N, Ikeda T, Nakashima H, Emi K. Impact of vitrectomy and air tamponade on aspheric intraocular lens Tilt and decentration and ocular higher-order aberrations: phacovitrectomy versus cataract surgery. Jpn J Ophthalmol. 2020;64(4):359\u201366.","journal-title":"Jpn J Ophthalmol"},{"issue":"10","key":"4583_CR3","doi-asserted-by":"publisher","first-page":"2145","DOI":"10.1016\/j.jcrs.2015.10.052","volume":"41","author":"IS Song","year":"2015","unstructured":"Song IS, Park JH, Park JH, Yoon SY, Kim JY, Kim MJ, et al. Corneal coma and trefoil changes associated with incision location in cataract surgery. J Cataract Refract Surg. 2015;41(10):2145\u201351.","journal-title":"J Cataract Refract Surg"},{"key":"4583_CR4","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1016\/j.visres.2020.12.007","volume":"181","author":"G Kiuchi","year":"2021","unstructured":"Kiuchi G, Hiraoka T, Ueno Y, Mihashi T, Oshika T. Influence of refractive status and age on corneal higher-order aberration. Vis Res. 2021;181:32\u20137.","journal-title":"Vis Res"},{"issue":"1","key":"4583_CR5","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1186\/s12886-023-03067-0","volume":"23","author":"S Zhou","year":"2023","unstructured":"Zhou S, Chen X, Ortega-Usobiaga J, Zheng H, Luo W, Tu B, et al. Characteristics and influencing factors of corneal higher-order aberrations in patients with cataract. BMC Ophthalmol. 2023;23(1):313.","journal-title":"BMC Ophthalmol"},{"issue":"12","key":"4583_CR6","doi-asserted-by":"publisher","first-page":"1482","DOI":"10.1016\/j.jcrs.2018.07.048","volume":"44","author":"M Zhang","year":"2018","unstructured":"Zhang M, Jing Q, Chen J, Jiang Y. Analysis of corneal higher-order aberrations in cataract patients with high myopia. J Cataract Refract Surg. 2018;44(12):1482\u201390.","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"4583_CR7","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1016\/j.ophtha.2016.09.039","volume":"124","author":"S Macrae","year":"2017","unstructured":"Macrae S, Holladay JT, Glasser A, Calogero D, Hilmantel G, Masket S, et al. Special report: American academy of ophthalmology task force consensus statement for extended depth of focus intraocular Lenses. Ophthalmology. 2017;124(1):139\u201341.","journal-title":"Ophthalmology"},{"issue":"3","key":"4583_CR8","doi-asserted-by":"publisher","first-page":"238","DOI":"10.1016\/j.clae.2018.11.014","volume":"42","author":"MJ Doughty","year":"2019","unstructured":"Doughty MJ, Jonuscheit S. Corneal structure, transparency, thickness and optical density (densitometry), especially as relevant to contact lens wear-a review. Cont Lens Anterior Eye. 2019;42(3):238\u201345.","journal-title":"Cont Lens Anterior Eye"},{"issue":"Suppl 1","key":"4583_CR9","doi-asserted-by":"publisher","first-page":"S53","DOI":"10.1097\/ICO.0000000000001388","volume":"36","author":"T Yamaguchi","year":"2017","unstructured":"Yamaguchi T, Shimizu E, Yagi-Yaguchi Y, Tomida D, Satake Y, Shimazaki J. A novel entity of corneal diseases with irregular posterior corneal surfaces: concept and clinical Relevance. Cornea. 2017;36(Suppl 1):S53\u20139.","journal-title":"Cornea"},{"key":"4583_CR10","doi-asserted-by":"publisher","first-page":"1144455","DOI":"10.3389\/fbioe.2023.1144455","volume":"11","author":"Y He","year":"2023","unstructured":"He Y, Ma BS, Zeng JH, Ma DJ. Corneal optical density: structural basis, measurements, influencing factors, and roles in refractive surgery. Front Bioeng Biotechnol. 2023;11:1144455.","journal-title":"Front Bioeng Biotechnol"},{"issue":"1","key":"4583_CR11","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1016\/j.survophthal.2024.09.007","volume":"70","author":"Q Yang","year":"2025","unstructured":"Yang Q, Ju G, He Y. Corneal densitometry: A new evaluation indicator for corneal diseases. Surv Ophthalmol. 2025;70(1):132\u201340.","journal-title":"Surv Ophthalmol"},{"issue":"4","key":"4583_CR12","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1080\/08820538.2019.1620796","volume":"34","author":"TH Dohlman","year":"2019","unstructured":"Dohlman TH, Yin J, Dana R. Methods for assessing corneal Opacity. Semin Ophthalmol. 2019;34(4):205\u201310.","journal-title":"Semin Ophthalmol"},{"issue":"5","key":"4583_CR13","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1097\/ICO.0000000000000099","volume":"33","author":"S Wei","year":"2014","unstructured":"Wei S, Song H, Tang X. Correlation of anterior corneal higher-order aberrations with age: a comprehensive investigation. Cornea. 2014;33(5):490\u20136.","journal-title":"Cornea"},{"issue":"1","key":"4583_CR14","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1097\/ICO.0000000000002722","volume":"41","author":"E Karmiris","year":"2022","unstructured":"Karmiris E, Soulantzou K, Machairoudia G, Ntravalias T, Tsiogka A, Chalkiadaki E. Corneal densitometry assessed with Scheimpflug camera in healthy Corneas and correlation with specular microscopy values and Age. Cornea. 2022;41(1):60\u20138.","journal-title":"Cornea"},{"issue":"1","key":"4583_CR15","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1167\/iovs.13-13236","volume":"55","author":"ND Sorcha","year":"2014","unstructured":"Sorcha ND, Rozema JJ, Jongenelen S, Ruiz Hidalgo I, Zakaria N, Tassignon MJ. Normative values for corneal densitometry analysis by Scheimpflug optical assessment. Invest Ophthalmol Vis Sci. 2014;55(1):162\u20138.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"11","key":"4583_CR16","doi-asserted-by":"publisher","first-page":"1336","DOI":"10.1097\/ICO.0000000000001363","volume":"36","author":"K Tekin","year":"2017","unstructured":"Tekin K, Sekeroglu MA, Kiziltoprak H, Yilmazbas P. Corneal densitometry in healthy Corneas and its correlation with endothelial Morphometry. Cornea. 2017;36(11):1336\u201342.","journal-title":"Cornea"},{"issue":"1","key":"4583_CR17","doi-asserted-by":"publisher","first-page":"50","DOI":"10.4103\/joco.joco_173_21","volume":"34","author":"M Pakbin","year":"2022","unstructured":"Pakbin M, Khabazkhoob M, Pakravan M, Fotouhi A, Jafarzadehpur E, Aghamirsalim M, et al. Repeatability of corneal densitometry measurements using a Scheimpflug camera in healthy normal Corneas. J Curr Ophthalmol. 2022;34(1):50\u20135.","journal-title":"J Curr Ophthalmol"},{"issue":"3","key":"4583_CR18","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1007\/s10384-018-0584-7","volume":"62","author":"AB Cankaya","year":"2018","unstructured":"Cankaya AB, Tekin K, Kiziltoprak H, Karahan S, Yilmazbas P. Assessment of corneal backward light scattering in the healthy cornea and factors affecting corneal transparency. Jpn J Ophthalmol. 2018;62(3):335\u201341.","journal-title":"Jpn J Ophthalmol"},{"issue":"2","key":"4583_CR19","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1097\/ICO.0000000000002511","volume":"40","author":"A Consejo","year":"2021","unstructured":"Consejo A, Jim\u00e9nez-Garc\u00eda M, Rozema JJ. Age-Related corneal transparency changes evaluated with an alternative method to corneal Densitometry. Cornea. 2021;40(2):215\u201322.","journal-title":"Cornea"},{"issue":"10","key":"4583_CR20","doi-asserted-by":"publisher","first-page":"7274","DOI":"10.1167\/iovs.11-7747","volume":"52","author":"T Hillenaar","year":"2011","unstructured":"Hillenaar T, Cals RH, Eilers PH, Wubbels RJ, Van Cleynenbreugel H, Remeijer L. Normative database for corneal backscatter analysis by in vivo confocal microscopy. Invest Ophthalmol Vis Sci. 2011;52(10):7274\u201381.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"1","key":"4583_CR21","doi-asserted-by":"publisher","first-page":"230","DOI":"10.1186\/s12886-024-03500-y","volume":"24","author":"J Ning","year":"2024","unstructured":"Ning J, Sun S, Zhang Q, Jin L, Liu X, Xu J, et al. Corneal densitometry in Chinese adults with healthy corneas: associations with sex, age, ocular metrics, and optical characteristics. BMC Ophthalmol. 2024;24(1):230.","journal-title":"BMC Ophthalmol"},{"issue":"1","key":"4583_CR22","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1186\/s12886-017-0407-5","volume":"17","author":"T Tandogan","year":"2017","unstructured":"Tandogan T, Auffarth GU, Choi CY, Liebing S, Mayer C, Khoramnia R. In vitro comparative optical bench analysis of a spherical and aspheric optic design of the same IOL model. BMC Ophthalmol. 2017;17(1):9.","journal-title":"BMC Ophthalmol"},{"key":"4583_CR23","doi-asserted-by":"crossref","unstructured":"Dubbelman M, Sicam VA, Van Der Heijde RG. The contribution of the posterior surface to the coma aberration of the human cornea. J Vis. 2007;7(7):10.1\u201310.8.","DOI":"10.1167\/7.7.10"},{"key":"4583_CR24","doi-asserted-by":"publisher","first-page":"933","DOI":"10.2147\/OPTH.S44056","volume":"7","author":"AC Kingston","year":"2013","unstructured":"Kingston AC, Cox IG. Population spherical aberration: associations with ametropia, age, corneal curvature, and image quality. Clin Ophthalmol. 2013;7:933\u20138.","journal-title":"Clin Ophthalmol"},{"issue":"2","key":"4583_CR25","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/j.joco.2016.03.001","volume":"28","author":"A Mirzajani","year":"2016","unstructured":"Mirzajani A, Aghataheri S, Ghoreishi M, Jafarzadepour E, Mohammadinia M. Evaluation of corneal higher order aberrations in normal topographic patterns. J Curr Ophthalmol. 2016;28(2):75\u201380.","journal-title":"J Curr Ophthalmol"},{"issue":"6","key":"4583_CR26","doi-asserted-by":"publisher","first-page":"1263","DOI":"10.1007\/s10792-016-0397-y","volume":"37","author":"N Garz\u00f3n","year":"2017","unstructured":"Garz\u00f3n N, Poyales F, Illarramendi I, Mendicute J, J\u00e1\u00f1ez \u00d3, Caro P, et al. Corneal densitometry and its correlation with age, pachymetry, corneal curvature, and refraction. Int Ophthalmol. 2017;37(6):1263\u20138.","journal-title":"Int Ophthalmol"},{"issue":"9","key":"4583_CR27","doi-asserted-by":"publisher","first-page":"1218","DOI":"10.1097\/j.jcrs.0000000000000650","volume":"47","author":"PK Gupta","year":"2021","unstructured":"Gupta PK, Berdahl JP, Chan CC, Rocha KM, Yeu E, Ayres B, et al. The corneal endothelium: clinical review of endothelial cell health and function. J Cataract Refract Surg. 2021;47(9):1218\u201326.","journal-title":"J Cataract Refract Surg"},{"issue":"14","key":"4583_CR28","doi-asserted-by":"publisher","first-page":"Des36","DOI":"10.1167\/iovs.17-23500","volume":"59","author":"S Koh","year":"2018","unstructured":"Koh S. Irregular astigmatism and Higher-Order aberrations in eyes with dry eye Disease. Invest Ophthalmol Vis Sci. 2018;59(14):Des36\u201340.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"8","key":"4583_CR29","doi-asserted-by":"publisher","first-page":"2667","DOI":"10.1007\/s10792-021-01822-0","volume":"41","author":"YC Y\u0131lmaz","year":"2021","unstructured":"Y\u0131lmaz YC, Ipek SC, Ozer MD. Corneal and lens densitometry in patients with vernal keratoconjunctivitis. Int Ophthalmol. 2021;41(8):2667\u201376.","journal-title":"Int Ophthalmol"},{"issue":"9","key":"4583_CR30","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1007\/s00347-018-0667-3","volume":"115","author":"M Alnawaiseh","year":"2018","unstructured":"Alnawaiseh M, Eter N. [Corneal densitometry: value for keratoconus diagnostics]. Ophthalmologe. 2018;115(9):737\u201343.","journal-title":"Ophthalmologe"},{"issue":"3","key":"4583_CR31","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1097\/ICO.0000000000000711","volume":"35","author":"M Alnawaiseh","year":"2016","unstructured":"Alnawaiseh M, Zumhagen L, Wirths G, Eveslage M, Eter N, Rosentreter A. Corneal Densitometry, central corneal thickness, and corneal central-to-Peripheral thickness ratio in patients with Fuchs endothelial Dystrophy. Cornea. 2016;35(3):358\u201362.","journal-title":"Cornea"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-025-04583-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-025-04583-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-025-04583-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T17:49:10Z","timestamp":1781632150000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12886-025-04583-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,19]]},"references-count":31,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["4583"],"URL":"https:\/\/doi.org\/10.1186\/s12886-025-04583-x","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,19]]},"assertion":[{"value":"20 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study protocol was reviewed and approved by the Human Research Ethics Committee of the First Affiliated Hospital of Chongqing Medical University, approval number (2021\u2009\u2212\u2009587). Written informed consent was obtained from all participants before data collection in accordance with the tenets of the Declaration of Helsinki.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"80"}}