{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T20:56:59Z","timestamp":1781643419862,"version":"3.54.5"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T00:00:00Z","timestamp":1773878400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T00:00:00Z","timestamp":1777334400000},"content-version":"vor","delay-in-days":40,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>To compare the effectiveness and outcomes of three surgical techniques for dense cataract removal: Nitinol filament mechanical phaco-fragmentation (NFMP), Phaco-chop, and Stop&amp;Chop by evaluating their impact on ultrasound energy consumption and key perioperative parameters.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      This is a single-center non-randomized retrospective study of patients with dense cataracts who underwent phacoemulsification using NFMP, Phaco-chop, or Stop&amp;Chop techniques. The primary outcome was cumulative dissipated energy (CDE). Secondary outcomes included aspiration time, irrigation fluid usage, phacoemulsification time, endothelial cell loss, and postoperative inflammation. Patients with endothelial cell counts\u2009&lt;\u20092,000 cells\/mm\n                      <jats:sup>2<\/jats:sup>\n                      , pseudoexfoliation syndrome, uncontrolled glaucoma, zonular weakness, or prior ocular surgeries were excluded.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The study included 105 eyes, distributed across three groups. Mean CDE was lowest in the NFMP group (7.90\u00b13.16), followed by Phacochop (9.25\u00b13.13) and Stop&amp;Chop (10.79\u00b13.94); a statistically significant reduction was found between NFMP and Stop&amp;Chop (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.05). Mean phacoemulsification time with NFMP was significantly shorter (40.31\u00b131.71 s) than with Phaco-chop (79.18\u00b134.20 s) or Stop&amp;Chop (80.84\u00b136.76 s) (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.01).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Mechanical phaco-fragmentation with NFMP achieved significantly lower energy consumption compared to Stop&amp;Chop, with safety and fluidics comparable to those of conventional techniques. These findings align with the existing literature, which shows the benefits of NFMP in challenging cataract cases; however, the magnitude and significance of the effects may vary depending on patient selection and cataract complexity.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Clinical trial number<\/jats:title>\n                    <jats:p>Not applicable.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12886-026-04742-8","type":"journal-article","created":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T16:38:11Z","timestamp":1773938291000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Effectiveness of Phaco-chop, Stop&amp;Chop, and the nitinol filament nuclear disassembly techniques for dense cataract removal"],"prefix":"10.1186","volume":"26","author":[{"given":"Diego","family":"Zalapa","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juan Pablo","family":"Herrera-Espinosa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emilia","family":"Ramos-Barrera","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carolina","family":"Cant\u00fa-Rosales","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sabrina","family":"Munita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roberto","family":"Gonz\u00e1lez-Salinas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,19]]},"reference":[{"key":"4742_CR1","doi-asserted-by":"publisher","unstructured":"Hu EH, Buie T, Jensen RJ, Wu D, Pamnani RD. Comparative study of safety outcomes following nucleus disassembly with and without the NFMP lens fragmentation device during cataract surgery. Clin Ophthalmol. 2022;16:2391\u2013401. https:\/\/doi.org\/10.2147\/OPTH.S370290.","DOI":"10.2147\/OPTH.S370290"},{"key":"4742_CR2","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1586\/17469899.2015.982097","volume":"10","author":"J Crispim","year":"2014","unstructured":"Crispim J, Jung LS, Paz L, Allemann N, Schor P. The surgical challenges dense brunescent cataracts present. Expert Rev Ophthalmol. 2014;10:13\u201322. https:\/\/doi.org\/10.1586\/17469899.2015.982097.","journal-title":"Expert Rev Ophthalmol"},{"key":"4742_CR3","doi-asserted-by":"publisher","first-page":"1799","DOI":"10.1016\/j.jcrs.2011.04.024","volume":"37","author":"EC Kim","year":"2011","unstructured":"Kim EC, Byun YS, Kim MS. Microincision versus small-incision coaxial cataract surgery using different power modes for hard nuclear cataract. J Cataract Refract Surg. 2011;37:1799\u2013805. https:\/\/doi.org\/10.1016\/j.jcrs.2011.04.024.","journal-title":"J Cataract Refract Surg"},{"key":"4742_CR4","doi-asserted-by":"publisher","first-page":"236","DOI":"10.3928\/15428877-20100303-13","volume":"41","author":"JH Park","year":"2010","unstructured":"Park JH, Lee SM, Kwon JW, et al. Ultrasound energy in phacoemulsification: a comparative analysis of phaco-chop and stop-and-chop techniques according to the degree of nuclear density. Ophthalmic Surg Lasers Imag. 2010;41:236\u201341. https:\/\/doi.org\/10.3928\/15428877-20100303-13.","journal-title":"Ophthalmic Surg Lasers Imag"},{"key":"4742_CR5","doi-asserted-by":"publisher","first-page":"1028","DOI":"10.1097\/j.jcrs.0000000000000575","volume":"47","author":"WF Wiley","year":"2021","unstructured":"Wiley WF, Bafna S, Logothetis HD. Comparative study of phacoemulsification parameters with and without nitinol filament nuclear disassembly. J Cataract Refract Surg. 2021;47:1028\u201331. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000575.","journal-title":"J Cataract Refract Surg"},{"key":"4742_CR6","doi-asserted-by":"publisher","first-page":"831","DOI":"10.1001\/archopht.1993.01090060119035","volume":"111","author":"LT Chylack","year":"1993","unstructured":"Chylack LT, Wolfe JK, Singer DM, et al. The lens Opacities Classification System III. The longitudinal study of cataract study group. Arch Ophthalmol. 1993;111:831\u201336. https:\/\/doi.org\/10.1001\/archopht.1993.01090060119035.","journal-title":"Arch Ophthalmol"},{"key":"4742_CR7","doi-asserted-by":"publisher","first-page":"1907","DOI":"10.1007\/s10792-017-0674-4","volume":"38","author":"R Gonzalez-Salinas","year":"2018","unstructured":"Gonzalez-Salinas R, Garza-Leon M, Saenz-de-Viteri M, Solis-S JC, Gulias-Ca\u00f1izo R, Quiroz-Mercado H. Comparison of cumulative dissipated energy delivered by active-fluidic pressure control phacoemulsification system versus gravity-fluidics. Int Ophthalmol. 2018;38:1907\u201313. https:\/\/doi.org\/10.1007\/s10792-017-0674-4.","journal-title":"Int Ophthalmol"},{"key":"4742_CR8","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1016\/j.ajo.2005.03.057","volume":"140","author":"DA Jabs","year":"2005","unstructured":"Jabs DA, Nussenblatt RB, Rosenbaum JT. Standardization of uveitis nomenclature (SUN) working group. Standardization of uveitis nomenclature for reporting clinical data. Results First Int Workshop. Am J Ophthalmol. 2005;140:509\u201316. https:\/\/doi.org\/10.1016\/j.ajo.2005.03.057.","journal-title":"Results The First Int Workshop. Am J Ophthalmol"},{"key":"4742_CR9","doi-asserted-by":"publisher","first-page":"932","DOI":"10.1016\/j.jcrs.2018.05.017","volume":"44","author":"T Ianchulev","year":"2018","unstructured":"Ianchulev T, Chang DF, Koo E, MacDonald S. Microinterventional endocapsular nucleus disassembly for phacoemulsification-free full-thickness fragmentation. J Cataract Refract Surg. 2018;44:932\u201334. https:\/\/doi.org\/10.1016\/j.jcrs.2018.05.017.","journal-title":"J Cataract Refract Surg"},{"key":"4742_CR10","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1136\/bjophthalmol-2017-311766","volume":"103","author":"T Ianchulev","year":"2019","unstructured":"Ianchulev T, Chang DF, Koo E, et al. Microinterventional endocapsular nucleus disassembly: novel technique and results of first-in-human randomised controlled study. Br J Ophthalmol. 2019;103:176\u201380. https:\/\/doi.org\/10.1136\/bjophthalmol-2017-311766.","journal-title":"Br J Ophthalmol"},{"key":"4742_CR11","doi-asserted-by":"publisher","first-page":"1463","DOI":"10.1016\/j.jcrs.2013.04.033","volume":"39","author":"J Park","year":"2013","unstructured":"Park J, Yum HR, Kim MS, Harrison AR, Kim EC. Comparison of phaco-chop, divide-and-conquer, and stop-and-chop phaco techniques in microincision coaxial cataract surgery. J Cataract Refractive Surg. 2013;39:1463\u201369. https:\/\/doi.org\/10.1016\/j.jcrs.2013.04.033.","journal-title":"J Cataract Refractive Surg"},{"key":"4742_CR12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2015\/210716","volume":"2015","author":"HB Hwang","year":"2015","unstructured":"Hwang HB, Lyu B, Yim HB, Lee NY. Endothelial cell loss after phacoemulsification according to different anterior chamber depths. J Ophthalmol. 2015;2015:1\u20137. https:\/\/doi.org\/10.1155\/2015\/210716.","journal-title":"J Ophthalmol"},{"key":"4742_CR13","doi-asserted-by":"publisher","first-page":"7","DOI":"10.69605\/ijlbpr_13.6.2","volume":"13","author":"N Singh","year":"2024","unstructured":"Singh N, Kumar R, Singh K. Comparison between direct chop and stop and chop phacoemulsification techniques in grade 3 and 4 cataract patients. Int J Multiling Life Sci, Biotechnol Pharma Res. 2024;13:7\u201319. https:\/\/doi.org\/10.69605\/ijlbpr_13.6.2.","journal-title":"Int J Multiling Life Sci, Biotechnol Pharma Res"},{"key":"4742_CR14","doi-asserted-by":"publisher","first-page":"2405","DOI":"10.2147\/OPTH.S407705","volume":"17","author":"E Fern\u00e1ndez-Mu\u00f1oz","year":"2023","unstructured":"Fern\u00e1ndez-Mu\u00f1oz E, Ch\u00e1vez-Romero Y, Rivero-G\u00f3mez R, Aridjis R, Gonzalez-Salinas R. Cumulative dissipated energy (CDE) in three Phaco-fragmentation techniques for dense cataract removal. Clin Ophthalmol. 2023;17:2405\u201312. https:\/\/doi.org\/10.2147\/OPTH.S407705.","journal-title":"Clin Ophthalmol"},{"key":"4742_CR15","doi-asserted-by":"publisher","first-page":"1515","DOI":"10.1097\/j.jcrs.0000000000000320","volume":"46","author":"GJ Roper","year":"2020","unstructured":"Roper GJ, Hoffer KJ, Pamnani RD. Effect of microinterventional endocapsular nucleus disassembly using centripetal loop fragmentation on refractive outcomes after cataract surgery. J Cataract Refract Surg. 2020;46:1515\u201321. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000320.","journal-title":"J Cataract Refract Surg"},{"key":"4742_CR16","doi-asserted-by":"publisher","unstructured":"Vivekanandan VR, Nachiappan S, Odayappan A, Venkatesh R, Chang DF. Piggyback miLOOP-assisted phacoemulsification combined with intraocular lens scaffold in hypermature cataracts. J Cataract Refractive Surg. 2020;47:e10\u201313. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000473.","DOI":"10.1097\/j.jcrs.0000000000000473"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-026-04742-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-04742-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-04742-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T20:30:15Z","timestamp":1781641815000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12886-026-04742-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,19]]},"references-count":16,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["4742"],"URL":"https:\/\/doi.org\/10.1186\/s12886-026-04742-8","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,19]]},"assertion":[{"value":"6 November 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Ethics Committee and Internal Review Board of the Asociaci\u00f3n para Evitar la Ceguera and conducted in accordance with the Declaration of Helsinki and Good Clinical Practices Guidelines. As this was a retrospective study of previously collected, anonymized clinical data, the requirement for individual informed consent to participate was waived by the Ethics Committee and Internal Review Board of the Asociaci\u00f3n para Evitar la Ceguera.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"During the preparation of this work, the authors used Grammarly to improve the grammar and clarity of the manuscript text. After using this tool, the authors reviewed and edited the content as needed and take full responsibility for the content of the publication.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"AI Use"}},{"value":"Dr. Gonzalez-Salinas reports personal fees from NexEos Inc., LayerBio Inc., and Alcon Inc. outside the submitted work. None of the previous disclosures conflicts with the present work. The other authors have no financial or proprietary interest in any material or method mentioned.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"218"}}