{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,20]],"date-time":"2026-05-20T00:06:07Z","timestamp":1779235567255,"version":"3.51.4"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,4,14]],"date-time":"2026-04-14T00:00:00Z","timestamp":1776124800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,5,20]],"date-time":"2026-05-20T00:00:00Z","timestamp":1779235200000},"content-version":"vor","delay-in-days":36,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"DOI":"10.1186\/s12886-026-04820-x","type":"journal-article","created":{"date-parts":[[2026,4,14]],"date-time":"2026-04-14T09:49:06Z","timestamp":1776160146000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Analysis of visual quality after implantation of diffractive multifocal intraocular lens Diff - aA in cataract patients"],"prefix":"10.1186","volume":"26","author":[{"given":"Zhang","family":"Jingwen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sun","family":"Louxun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yang","family":"Yifan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Du","family":"Shanshan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shao","family":"Jingzhi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhang","family":"Fengyan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,4,14]]},"reference":[{"issue":"8","key":"4820_CR1","doi-asserted-by":"publisher","first-page":"1357","DOI":"10.1038\/s41433-020-0806-3","volume":"34","author":"H Hashemi","year":"2020","unstructured":"Hashemi H, Pakzad R, Yekta A, et al. Global and regional prevalence of age-related cataract: a comprehensive systematic review and meta-analysis[J]. Eye (Lond). 2020;34(8):1357\u201370. https:\/\/doi.org\/10.1038\/s41433-020-0806-3.","journal-title":"Eye (Lond)"},{"issue":"6","key":"4820_CR2","doi-asserted-by":"publisher","first-page":"668","DOI":"10.1111\/ceo.14535","volume":"53","author":"B Stern","year":"2025","unstructured":"Stern B, Gatinel D. Presbyopia Correction in Lens Replacement Surgery: A Review[J]. Clin Exp Ophthalmol. 2025;53(6):668\u201381. https:\/\/doi.org\/10.1111\/ceo.14535.","journal-title":"Clin Exp Ophthalmol"},{"issue":"2","key":"4820_CR3","doi-asserted-by":"publisher","first-page":"e131","DOI":"10.3928\/1081597X-20241230-01","volume":"41","author":"F Howes","year":"2025","unstructured":"Howes F, Rementeria-Capelo LA, Poyales F, Borovik A, et al. Visual Performance and Patient Satisfaction of Bilaterally Implanted Extended Depth of Focus Intraocular Lens: Outcomes of a Multicenter Registry[J]. J Refract Surg. 2025;41(2):e131\u201343. https:\/\/doi.org\/10.3928\/1081597X-20241230-01.","journal-title":"J Refract Surg"},{"issue":"5","key":"4820_CR4","doi-asserted-by":"publisher","first-page":"863","DOI":"10.1007\/s00417-018-04218-6","volume":"257","author":"SS Khandelwal","year":"2019","unstructured":"Khandelwal SS, Jun JJ, Mak S, et al. Effectiveness of multifocal and monofocal intraocular lenses for cataract surgery and lens replacement: a systematic review and meta-analysis[J]. Graefes Arch Clin Exp Ophthalmol. 2019;257(5):863\u201375. https:\/\/doi.org\/10.1007\/s00417-018-04218-6.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"issue":"5","key":"4820_CR5","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1016\/j.survophthal.2017.03.005","volume":"62","author":"JL Alio","year":"2017","unstructured":"Alio JL, Plaza-Puche AB, F\u00e9rnandez-Buenaga R, et al. Multifocal intraocular lenses: An overview[J]. Surv Ophthalmol. 2017;62(5):611\u201334. https:\/\/doi.org\/10.1016\/j.survophthal.2017.03.005.","journal-title":"Surv Ophthalmol"},{"issue":"2","key":"4820_CR6","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1016\/j.ophtha","volume":"128","author":"S Modi","year":"2021","unstructured":"Modi S, Lehmann R, Maxwell A, et al. Visual and patient-reported outcomes of a diffractive trifocal intraocular lens compared with those of a monofocal intraocular lens[J]. Ophthalmology. 2021;128(2):197\u2013207. https:\/\/doi.org\/10.1016\/j.ophtha.","journal-title":"Ophthalmology"},{"issue":"22","key":"4820_CR7","doi-asserted-by":"publisher","first-page":"1540","DOI":"10.21037\/atm-2020-rcs-16","volume":"8","author":"A Grzybowski","year":"2020","unstructured":"Grzybowski A. Recent developments in cataract surgery[J]. Ann Transl Med. 2020;8(22):1540. https:\/\/doi.org\/10.21037\/atm-2020-rcs-16.","journal-title":"Ann Transl Med"},{"key":"4820_CR8","unstructured":"HumanOptics(n. d.). DIFFRACTIVA\u00ae. https:\/\/www.humanoptics.com\/arzte\/intraokularlinsen\/multifokal-diffractiva\/."},{"issue":"3","key":"4820_CR9","doi-asserted-by":"publisher","first-page":"673","DOI":"10.1007\/s00417-020-05052-5","volume":"259","author":"K Mih\u00e1ltz","year":"2021","unstructured":"Mih\u00e1ltz K, V\u00e9csei-Marlovits PV. The impact of visual axis position on the optical quality after implantation of multifocal intraocular lenses with different asphericity values. Graefes Arch Clin Exp Ophthalmol. 2021;259(3):673\u201383. https:\/\/doi.org\/10.1007\/s00417-020-05052-5.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"issue":"2","key":"4820_CR10","doi-asserted-by":"publisher","first-page":"87","DOI":"10.3760\/cma.j.issn.1674-845X.2017.02.005","volume":"19","author":"F Fan","year":"2017","unstructured":"Fan F, Xin L, Yanwen F, et al. A pilot study of +\u20093.5 D aspheric diffractive multifocal intraocular lens implantation using a real-time intraoperative navigation system[J]. Chin J Optometry Ophthalmol Visual Sci. 2017;19(2):87\u201392. https:\/\/doi.org\/10.3760\/cma.j.issn.1674-845X.2017.02.005.","journal-title":"Chin J Optometry Ophthalmol Visual Sci"},{"key":"4820_CR11","unstructured":"TECNIS\u2122 ZMB00 DfU-INT-Z311335[M]. Rev. 02, Johnson & Johnson Vision, 2019."},{"key":"4820_CR12","unstructured":"TECNIS\u2122. Multifocal 1-Piece IOLs, Models ZKB00, ZLB00 and ZMB00-Patient Information Brochure[M]. Johnson & Johnson Vision; 2015."},{"issue":"1","key":"4820_CR13","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1186\/s12886-024-03439-0","volume":"24","author":"S Guo","year":"2024","unstructured":"Guo S, Huang H, Li B, et al. Comparatively analysing the postoperative optical performance of different intraocular lenses: a prospective observational study[J]. BMC Ophthalmol. 2024;24(1):198. https:\/\/doi.org\/10.1186\/s12886-024-03439-0.","journal-title":"BMC Ophthalmol"},{"issue":"5","key":"4820_CR14","doi-asserted-by":"publisher","first-page":"630","DOI":"10.1001\/archopht.1994.01090170074026","volume":"112","author":"EP Steinberg","year":"1994","unstructured":"Steinberg EP, Tielsch JM, Schein OD, et al. The VF-14. An index of functional impairment in patients with cataract. Arch Ophthalmol. 1994;112(5):630\u20138. https:\/\/doi.org\/10.1001\/archopht.1994.01090170074026.","journal-title":"Arch Ophthalmol"},{"issue":"4","key":"4820_CR15","doi-asserted-by":"publisher","first-page":"607","DOI":"10.3980\/j.issn.1672-5123.2023.4.15","volume":"23","author":"ZY Citation:Li","year":"2023","unstructured":"Citation:Li ZY, Li C. Research progress and clinical application of the visual functioning index. Guoji Yanke Zazhi(Int Eye Sci). 2023;23(4):607\u201311. https:\/\/doi.org\/10.3980\/j.issn.1672-5123.2023.4.15.","journal-title":"Guoji Yanke Zazhi(Int Eye Sci)"},{"issue":"7","key":"4820_CR16","doi-asserted-by":"publisher","first-page":"1195","DOI":"10.1016\/s0886-3350(02)01208-7","volume":"28","author":"JD Hunkeler","year":"2002","unstructured":"Hunkeler JD, Coffman TM, Paugh J, Lang A, Smith P, Tarantino N. Characterization of visual phenomena with the Array multifocal intraocular lens[J]. J Cataract Refract Surg. 2002;28(7):1195\u2013204. https:\/\/doi.org\/10.1016\/s0886-3350(02)01208-7.","journal-title":"J Cataract Refract Surg"},{"key":"4820_CR17","doi-asserted-by":"publisher","unstructured":"Chongxing Liu Y, Yang W, Yang et al. Applications of complex surfaces in ophthalmic lens design: microlens arrays, freeform surfaces, and diffractive optics[J].Optics & Laser Technology. 2025,192,113471-22. https:\/\/doi.org\/10.1016\/j.optlastec.2025.113471.","DOI":"10.1016\/j.optlastec.2025.113471"},{"issue":"10094","key":"4820_CR18","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1016\/S0140-6736(17)30544-5","volume":"390","author":"YC Liu","year":"2017","unstructured":"Liu YC, Wilkins M, Kim T, et al. Cataracts[J] Lancet. 2017;390(10094):600\u201312. https:\/\/doi.org\/10.1016\/S0140-6736(17)30544-5.","journal-title":"Cataracts[J] Lancet"},{"issue":"1","key":"4820_CR19","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1186\/s12886-024-03685-2","volume":"27","author":"J Wang","year":"2024","unstructured":"Wang J, Luo J, Yang W, et al. Efficacy and comfort following the implantation of extended depth of focus, multifocal, and monofocal intraocular lenses in cataract patients[J]. BMC Ophthalmol. 2024;27(1):423. https:\/\/doi.org\/10.1186\/s12886-024-03685-2.","journal-title":"BMC Ophthalmol"},{"issue":"2","key":"4820_CR20","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1016\/j.optom.2015.06.005","volume":"9","author":"G Cardona","year":"2016","unstructured":"Cardona G, L\u00f3pez S. Pupil diameter, working distance and illumination during habitual tasks. Implications for simultaneous vision contact lenses for presbyopia[J]. J Optom. 2016;9(2):78\u201384. https:\/\/doi.org\/10.1016\/j.optom.2015.06.005.","journal-title":"J Optom"},{"issue":"2","key":"4820_CR21","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1111\/cxo.12453","volume":"100","author":"J Long","year":"2017","unstructured":"Long J, Cheung R, Duong S, et al. Viewing distance and eyestrain symptoms with prolonged viewing of smartphones. Clin Exp Optom. 2017;100(2):133\u20137. https:\/\/doi.org\/10.1111\/cxo.12453.","journal-title":"Clin Exp Optom"},{"issue":"7","key":"4820_CR22","doi-asserted-by":"publisher","first-page":"795","DOI":"10.1097\/OPX.0b013e3182198792","volume":"88","author":"Y Bababekova","year":"2011","unstructured":"Bababekova Y, Rosenfield M, Hue JE, et al. Font size and viewing distance of handheld smart phones. Optom Vis Sci. 2011;88(7):795\u20137. https:\/\/doi.org\/10.1097\/OPX.0b013e3182198792.","journal-title":"Optom Vis Sci"},{"issue":"2","key":"4820_CR23","doi-asserted-by":"publisher","first-page":"85","DOI":"10.3390\/photonics9020085","volume":"9","author":"L Clav\u00e9","year":"2022","unstructured":"Clav\u00e9 L, Torrents A, Mill\u00e1n MS. Visual Acuity at Various Distances and Defocus Curve: A Good Match[J]. Photonics. 2022;9(2):85. https:\/\/doi.org\/10.3390\/photonics9020085.","journal-title":"Photonics"},{"issue":"9","key":"4820_CR24","doi-asserted-by":"publisher","first-page":"942","DOI":"10.1097\/j.jcrs.0000000000001491","volume":"50","author":"P Ta\u00f1\u00e1-Rivero","year":"2024","unstructured":"Ta\u00f1\u00e1-Rivero P, Ta\u00f1\u00e1-Sanz P, Ta\u00f1\u00e1-Sanz S, et al. Recognition vs resolution charts for defocus curve determination in trifocal intraocular lenses[J]. J Cataract Refract Surg. 2024;50(9):942\u20136. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001491.","journal-title":"J Cataract Refract Surg"},{"issue":"8","key":"4820_CR25","doi-asserted-by":"publisher","first-page":"961","DOI":"10.1097\/j.jcrs.0000000000000906","volume":"48","author":"T Kohnen","year":"2022","unstructured":"Kohnen T, Lemp-Hull J, Suryakumar R. Defocus curves: focusing on factors influencing assessment[J]. J Cataract Refract Surg. 2022;48(8):961\u20138. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000906.","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"4820_CR26","doi-asserted-by":"publisher","first-page":"1287","DOI":"10.1016\/j.jcrs.2017.07.031","volume":"43","author":"AM Rosa","year":"2017","unstructured":"Rosa AM, Miranda \u00c2C, Patr\u00edcio MM, Castelo-Branco M, Murta JN, et al. Functional magnetic resonance imaging to assess neuroadaptation to multifocal intraocular lenses[J]. J Cataract Refract Surg. 2017;43(10):1287\u201396. https:\/\/doi.org\/10.1016\/j.jcrs.2017.07.031.","journal-title":"J Cataract Refract Surg"},{"key":"4820_CR27","doi-asserted-by":"publisher","first-page":"1310468","DOI":"10.3389\/fopht.2024.1310468","volume":"4","author":"GK Bhogal-Bhamra","year":"2024","unstructured":"Bhogal-Bhamra GK, Aujla M, Kolli S, et al. Glare prediction and mechanism of adaptation following implantation of hydrophilic and hydrophobic intraocular lenses[J]. Front Ophthalmol (Lausanne). 2024;4:1310468. https:\/\/doi.org\/10.3389\/fopht.2024.1310468.","journal-title":"Front Ophthalmol (Lausanne)"},{"issue":"8","key":"4820_CR28","doi-asserted-by":"publisher","first-page":"1487","DOI":"10.1016\/s0886-3350(03)00334-1","volume":"29","author":"RA Applegate","year":"2003","unstructured":"Applegate RA, Marsack JD, Ramos R, et al. Interaction between aberrations to improve or reduce visual performance[J]. J Cataract Refract Surg. 2003;29(8):1487\u201395. https:\/\/doi.org\/10.1016\/s0886-3350(03)00334-1.","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"4820_CR29","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1097\/00006324-200302000-00005","volume":"80","author":"RA Applegate","year":"2003","unstructured":"Applegate RA, Ballentine C, Gross H, et al. Visual acuity as a function of Zernike mode and level of root mean square error[J]. Optom Vis Sci. 2003;80(2):97\u2013105. https:\/\/doi.org\/10.1097\/00006324-200302000-00005.","journal-title":"Optom Vis Sci"},{"issue":"7","key":"4820_CR30","doi-asserted-by":"publisher","first-page":"1273","DOI":"10.18240\/ijo.2024.07.12","volume":"17","author":"BW Li","year":"2024","unstructured":"Li BW, Huang H, Huang MS, Guo SL, Gao L, Zeng YY, Cheng L, Yao SY, Lin JQ, Liu L, Yang Y, Lu XM, Cheng H. Changes in visual performance after implantation of different intraocular lenses[J]. Int J Ophthalmol. 2024;17(7):1273\u201382. https:\/\/doi.org\/10.18240\/ijo.2024.07.12.","journal-title":"Int J Ophthalmol"},{"key":"4820_CR31","doi-asserted-by":"publisher","first-page":"1244","DOI":"10.1016\/j.jcrs.2009.02.024","volume":"35","author":"A Castillo-Gomez","year":"2009","unstructured":"Castillo-Gomez A, Carmona-Gonzalez D, Martinez-de-la-Casa JM, et al. Evaluation of image quality after implantation of 2 diffractive multifocal intraocular lens models. J Cataract Refract Surg. 2009;35:1244\u201350. https:\/\/doi.org\/10.1016\/j.jcrs.2009.02.024.","journal-title":"J Cataract Refract Surg"},{"issue":"7","key":"4820_CR32","doi-asserted-by":"publisher","first-page":"434","DOI":"10.3928\/1081597X-20190618-01","volume":"35","author":"L Rodov","year":"2019","unstructured":"Rodov L, Reitblat O, Levy A, Assia EI, Kleinmann G. Visual Outcomes and Patient Satisfaction for Trifocal, Extended Depth of Focus and Monofocal Intraocular Lenses[J]. J Refract Surg. 2019;35(7):434\u201340. https:\/\/doi.org\/10.3928\/1081597X-20190618-01.","journal-title":"J Refract Surg"},{"key":"4820_CR33","doi-asserted-by":"publisher","first-page":"403","DOI":"10.2147\/OPTH.S24425","volume":"6","author":"CP Bautista","year":"2012","unstructured":"Bautista CP, Gonz\u00e1lez DC, G\u00f3mez AC. Evolution of visual performance in 70 eyes implanted with the Tecnis(\u00ae) ZMB00 multifocal intraocular lens[J]. Clin Ophthalmol. 2012;6:403\u20137. https:\/\/doi.org\/10.2147\/OPTH.S24425.","journal-title":"Clin Ophthalmol"},{"issue":"5","key":"4820_CR34","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1016\/j.jcrs.2010.11.032","volume":"37","author":"NE de Vries","year":"2011","unstructured":"de Vries NE, Webers CA, Touwslager WR, Bauer NJ, de Brabander J, Berendschot TT, Nuijts RM. Dissatisfaction after implantation of multifocal intraocular lenses[J]. J Cataract Refract Surg. 2011;37(5):859\u201365. https:\/\/doi.org\/10.1016\/j.jcrs.2010.11.032.","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"4820_CR35","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1016\/s0886-3350(02)01648-6","volume":"29","author":"R Mont\u00e9s-Mic\u00f3","year":"2003","unstructured":"Mont\u00e9s-Mic\u00f3 R, Ali\u00f3 JL. Distance and near contrast sensitivity function after multifocal intraocular lens implantation[J]. J Cataract Refract Surg. 2003;29(4):703\u201311. https:\/\/doi.org\/10.1016\/s0886-3350(02)01648-6.","journal-title":"J Cataract Refract Surg"},{"issue":"4","key":"4820_CR36","doi-asserted-by":"publisher","first-page":"257","DOI":"10.3928\/1081597X-20161206-03","volume":"33","author":"V Akondi","year":"2017","unstructured":"Akondi V, Perez-Merino P, Martinez-Enriquez E, et al. Evaluation of the true wavefront aberrations in eyes implanted with a rotationally asymmetric multifocal intraocular lens[J]. J Refract Surg. 2017;33(4):257\u201365. https:\/\/doi.org\/10.3928\/1081597X-20161206-03.","journal-title":"J Refract Surg"},{"issue":"1","key":"4820_CR37","doi-asserted-by":"publisher","first-page":"19625","DOI":"10.1038\/s41598-022-23694-9","volume":"12","author":"M Zhu","year":"2022","unstructured":"Zhu M, Fan W, Zhang G. Visual outcomes and subjective experience with three intraocular lenses based presbyopia correcting strategies in cataract patients[J]. Sci Rep. 2022;12(1):19625. https:\/\/doi.org\/10.1038\/s41598-022-23694-9.","journal-title":"Sci Rep"},{"issue":"5","key":"4820_CR38","doi-asserted-by":"publisher","first-page":"863","DOI":"10.1007\/s00417-018-04218-6","volume":"257","author":"SS Khandelwal","year":"2019","unstructured":"Khandelwal SS, Jun JJ, Mak S, Booth MS, Shekelle PG. Effectiveness of multifocal and monofocal intraocular lenses for cataract surgery and lens replacement: a systematic review and meta-analysis. Graefe\u2019s Arch Clin Exp Ophthalmol. 2019;257(5):863\u201375. https:\/\/doi.org\/10.1007\/s00417-018-04218-6.","journal-title":"Graefe\u2019s Arch Clin Exp Ophthalmol"},{"key":"4820_CR39","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/j.neuroscience.2019.10.003","volume":"421","author":"D Khammash","year":"2019","unstructured":"Khammash D, Simmonite M, Polk TA, Taylor SF, Meehan SK. Temporal Dynamics of Corticocortical Inhibition in Human Visual Cortex: A TMS Study. Neuroscience[J]. 2019;421:31\u20138. https:\/\/doi.org\/10.1016\/j.neuroscience.2019.10.003.","journal-title":"Neuroscience[J]"},{"issue":"10","key":"4820_CR40","doi-asserted-by":"publisher","first-page":"1287","DOI":"10.1016\/j.jcrs.2017.07.031","volume":"43","author":"AM Rosa","year":"2017","unstructured":"Rosa AM, Miranda \u00c2C, Patr\u00edcio MM, McAlinden C, Silva FL, Castelo-Branco M, Murta JN. Functional magnetic resonance imaging to assess neuroadaptation to multifocal intraocular lenses[J]. J Cataract Refract Surg. 2017;43(10):1287\u201396. https:\/\/doi.org\/10.1016\/j.jcrs.2017.07.031.","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"4820_CR41","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1111\/aos.13508","volume":"96","author":"NY Makhotkina","year":"2018","unstructured":"Makhotkina NY, Nijkamp MD, Berendschot TTJM, van den Borne B, Nuijts RMMA. Effect of active evaluation on the detection of negative dysphotopsia after sequential cataract surgery: discrepancy between incidences of unsolicited and solicited complaints[J]. Acta Ophthalmol. 2018;96(1):81\u20137. https:\/\/doi.org\/10.1111\/aos.13508.","journal-title":"Acta Ophthalmol"},{"issue":"9","key":"4820_CR42","doi-asserted-by":"publisher","first-page":"1254","DOI":"10.1136\/bjophthalmol-2019-315255","volume":"104","author":"S Hopf","year":"2020","unstructured":"Hopf S, Korb C, Nickels S, et al. Prevalence of myopic maculopathy in the German population: results from the Gutenberg health study[J]. Br J Ophthalmol. 2020;104(9):1254\u20139. https:\/\/doi.org\/10.1136\/bjophthalmol-2019-315255.","journal-title":"Br J Ophthalmol"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-026-04820-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-04820-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-04820-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,19]],"date-time":"2026-05-19T23:13:22Z","timestamp":1779232402000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12886-026-04820-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,14]]},"references-count":42,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["4820"],"URL":"https:\/\/doi.org\/10.1186\/s12886-026-04820-x","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-8626404\/v1","asserted-by":"object"}]},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,14]]},"assertion":[{"value":"17 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Written informed consent was obtained from all participants before their inclusion in the study. This trial was conducted in accordance with the guidelines for clinical trials involving human participants and the Declaration of Helsinki. The research protocol was approved by the Ethics Committee of Zhengzhou University. (Ethical Review Number: 2024-KY-0645). This study adheres to the principles of the Declaration of Helsinki and was approved by the Ethics Committee of the Affiliated Hospital of Zhengzhou University on January 24, 2022 (Ethical Review Number: 2022 - KY\u2009\u2212\u20090006\u2009\u2212\u2009001). This approval covers relevant research on patients undergoing phacoemulsification combined with intraocular lens implantation for unilateral cataract from the date of approval until December 2025, including the collection of patients\u2019 clinical data, the evaluation of the implantation effects of different models of intraocular lenses, eye examinations, and follow - up.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participants"}},{"value":"Before the participant enters the study, written informed consent was obtained from all participants for the publication of results that will be used in a completely confidential manner and solely for research purposes, and the participants\u2019 identity will remain confidential within the framework of the law.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"279"}}