{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T01:57:37Z","timestamp":1781229457489,"version":"3.54.1"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,4,27]],"date-time":"2026-04-27T00:00:00Z","timestamp":1777248000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T00:00:00Z","timestamp":1781222400000},"content-version":"vor","delay-in-days":46,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"This work was supported by the Jiangxi Provincial Health Commission Science and Technology Plan, General Program","award":["SKJP220229877"],"award-info":[{"award-number":["SKJP220229877"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"DOI":"10.1186\/s12886-026-04857-y","type":"journal-article","created":{"date-parts":[[2026,4,27]],"date-time":"2026-04-27T09:25:39Z","timestamp":1777281939000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Comparative analysis of preoperative and postoperative changes in photopic and mesopic angle kappa and angle alpha in cataract surgery"],"prefix":"10.1186","volume":"26","author":[{"given":"Yuxiang","family":"Hu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Feifan","family":"Du","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jie","family":"Lai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Quan","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,4,27]]},"reference":[{"key":"4857_CR1","doi-asserted-by":"crossref","unstructured":"Kohnen T, Ramasubramanian V, Suryakumar R. A review of angle kappa and multifocal intraocular lenses and their effect on visual outcomes. ACTA OPHTHALMOL; 2025.","DOI":"10.1111\/aos.17561"},{"issue":"9","key":"4857_CR2","doi-asserted-by":"publisher","first-page":"1258","DOI":"10.1016\/j.jcrs.2019.04.003","volume":"45","author":"Y Fu","year":"2019","unstructured":"Fu Y, Kou J, Chen D, Wang D, Zhao Y, Hu M, Lin X, Dai Q, Li J, Zhao YE. Influence of angle kappa and angle alpha on visual quality after implantation of multifocal intraocular lenses. J CATARACT REFR SURG. 2019;45(9):1258\u201364.","journal-title":"J CATARACT REFR SURG"},{"issue":"5","key":"4857_CR3","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1097\/j.jcrs.0000000000000490","volume":"47","author":"J Meng","year":"2021","unstructured":"Meng J, Du Y, Wei L, Yao Y, He W, Qian D, Lu Y, Zhu X. Distribution of angle \u03b1 and angle \u03ba in a population with cataract in Shanghai. J CATARACT REFR SURG. 2021;47(5):579\u201384.","journal-title":"J CATARACT REFR SURG"},{"issue":"3","key":"4857_CR4","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1097\/j.jcrs.0000000000000063","volume":"46","author":"R Wang","year":"2020","unstructured":"Wang R, Long T, Gu X, Ma T. Changes in angle kappa and angle alpha before and after cataract surgery. J CATARACT REFR SURG. 2020;46(3):365\u201371.","journal-title":"J CATARACT REFR SURG"},{"key":"4857_CR5","doi-asserted-by":"publisher","first-page":"2879","DOI":"10.2147\/OPTH.S478471","volume":"18","author":"AH Assaf","year":"2024","unstructured":"Assaf AH, Samy H, Fawky N, Kamel MA. Evaluation of Visual Outcomes, Postoperative Angle Alpha, and Angle Kappa After Implantation of Isofocal Intraocular Lenses. CLIN OPHTHALMOL. 2024;18:2879\u201390.","journal-title":"CLIN OPHTHALMOL"},{"issue":"1","key":"4857_CR6","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1186\/s12886-021-02116-w","volume":"22","author":"M Qin","year":"2022","unstructured":"Qin M, Yuan Y, Wang Y, Li P, Chen W, Wang Y, Yang M, Wu J, Ji M, Luo J, et al. Comparison of preoperative angle kappa measurements in the eyes of cataract patients obtained from Pentacam Scheimpflug system, optical low-coherence reflectometry, and ray-tracing aberrometry. BMC OPHTHALMOL. 2022;22(1):153.","journal-title":"BMC OPHTHALMOL"},{"issue":"1","key":"4857_CR7","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1186\/s12886-022-02302-4","volume":"22","author":"M Qin","year":"2022","unstructured":"Qin M, Ji M, Zhou T, Yuan Y, Luo J, Li P, Wang Y, Chen X, Chen W, Guan H. Influence of angle alpha on visual quality after implantation of extended depth of focus intraocular lenses. BMC OPHTHALMOL. 2022;22(1):82.","journal-title":"BMC OPHTHALMOL"},{"issue":"5","key":"4857_CR8","doi-asserted-by":"publisher","first-page":"1895","DOI":"10.1007\/s10792-021-01751-y","volume":"41","author":"H Fukumitsu","year":"2021","unstructured":"Fukumitsu H, Camps VJ, Miraflores S, Pinero DP. Could anatomical changes occurring with cataract surgery have a clinically significant effect on effective intraocular lens position? INT OPHTHALMOL. 2021;41(5):1895\u2013907.","journal-title":"INT OPHTHALMOL"},{"issue":"6","key":"4857_CR9","doi-asserted-by":"publisher","first-page":"e420","DOI":"10.3928\/1081597X-20240416-01","volume":"40","author":"P Kanclerz","year":"2024","unstructured":"Kanclerz P, Bazylczyk N, Przewlocka K, Khoramnia R, Atchison DA, Tuuminen R. Risk Factors for Corneal Monochromatic Aberrations and Implications for Multifocal and Extended Depth-of-Focus Intraocular Lens Implantation. J REFRACT SURG. 2024;40(6):e420\u201334.","journal-title":"J REFRACT SURG"},{"issue":"1","key":"4857_CR10","doi-asserted-by":"publisher","first-page":"626","DOI":"10.1186\/s12886-025-04431-y","volume":"25","author":"B Li","year":"2025","unstructured":"Li B, Rao T, Tseng Y, Ma S, He L, Li X. Analysis and comparison of factors influencing post-cataract surgery kappa angle changes. BMC OPHTHALMOL. 2025;25(1):626.","journal-title":"BMC OPHTHALMOL"},{"issue":"1","key":"4857_CR11","doi-asserted-by":"publisher","first-page":"26732","DOI":"10.1038\/s41598-024-77699-7","volume":"14","author":"RET Ang","year":"2024","unstructured":"Ang RET, Doroy ZAM, Yao JAA, Cruz EM. Correlation of angle kappa and angle alpha on visual outcomes in eyes implanted with three types of multifocal intraocular lenses. SCI REP-UK. 2024;14(1):26732.","journal-title":"SCI REP-UK"},{"issue":"20","key":"4857_CR12","doi-asserted-by":"publisher","first-page":"5917","DOI":"10.1364\/AO.423000","volume":"60","author":"B Yuan","year":"2021","unstructured":"Yuan B, Li J, Song H. Effect of misalignment at different orientations associated with angle kappa on optical performance of aspheric intraocular lenses with different surface designs. APPL Opt. 2021;60(20):5917\u201324.","journal-title":"APPL Opt"},{"key":"4857_CR13","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1016\/j.ajo.2022.05.005","volume":"242","author":"J Xu","year":"2022","unstructured":"Xu J, Lin P, Zhang S, Lu Y, Zheng T. Risk Factors Associated With Intraocular Lens Decentration After Cataract Surgery. AM J OPHTHALMOL. 2022;242:88\u201395.","journal-title":"AM J OPHTHALMOL"},{"issue":"10","key":"4857_CR14","doi-asserted-by":"publisher","first-page":"1279","DOI":"10.1097\/j.jcrs.0000000000000612","volume":"47","author":"C Velasco-Barona","year":"2021","unstructured":"Velasco-Barona C, Corredor-Ortega C, Avendano-Dominguez A, Cervantes-Coste G, Cantu-Trevino MP, Gonzalez-Salinas R. Impact of correlation of angle alpha with ocular biometry variables. J CATARACT REFR SURG. 2021;47(10):1279\u201384.","journal-title":"J CATARACT REFR SURG"},{"issue":"3","key":"4857_CR15","doi-asserted-by":"publisher","first-page":"372","DOI":"10.1097\/j.jcrs.0000000000000066","volume":"46","author":"MA Mahr","year":"2020","unstructured":"Mahr MA, Simpson MJ, Erie JC. Angle alpha orientation and magnitude distribution in a cataract surgery population. J CATARACT REFR SURG. 2020;46(3):372\u20137.","journal-title":"J CATARACT REFR SURG"},{"issue":"1","key":"4857_CR16","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1007\/s00417-024-06596-6","volume":"263","author":"G Neuman","year":"2025","unstructured":"Neuman G, Abulafia A, Wasser L, Zadok D. Distribution of angle alpha and angle kappa offsets among adult candidates for cataract surgery. GRAEF ARCH CLIN EXP. 2025;263(1):157\u201370.","journal-title":"GRAEF ARCH CLIN EXP"},{"issue":"1","key":"4857_CR17","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1186\/s12886-024-03409-6","volume":"24","author":"Y Ye","year":"2024","unstructured":"Ye Y, Zhao Y, Zhang Z, Wei R, Xian Y, Huang Y, Liu F, Xu Y, Zhou X. Correlation analysis of angles kappa and alpha with the refraction and anterior segment parameters in children. BMC OPHTHALMOL. 2024;24(1):143.","journal-title":"BMC OPHTHALMOL"},{"issue":"1","key":"4857_CR18","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1016\/j.jcrs.2015.07.044","volume":"42","author":"G Savini","year":"2016","unstructured":"Savini G, Hoffer KJ, Lombardo M, Serrao S, Schiano-Lomoriello D, Ducoli P. Influence of the effective lens position, as predicted by axial length and keratometry, on the near add power of multifocal intraocular lenses. J CATARACT REFR SURG. 2016;42(1):44\u20139.","journal-title":"J CATARACT REFR SURG"},{"issue":"6","key":"4857_CR19","doi-asserted-by":"publisher","first-page":"1023","DOI":"10.18240\/ijo.2025.06.08","volume":"18","author":"XN Chen","year":"2025","unstructured":"Chen XN, Xiong YY, Wei J, Luo B, Gao YL. Alpha and Kappa angle on postoperative visual quality in cataract surgery. INT J OPHTHALMOL-CHI. 2025;18(6):1023\u201331.","journal-title":"INT J OPHTHALMOL-CHI"},{"issue":"9","key":"4857_CR20","doi-asserted-by":"publisher","first-page":"1258","DOI":"10.1016\/j.jcrs.2019.04.003","volume":"45","author":"Y Fu","year":"2019","unstructured":"Fu Y, Kou J, Chen D, Wang D, Zhao Y, Hu M, Lin X, Dai Q, Li J, Zhao Y. Influence of angle kappa and angle alpha on visual quality after implantation of multifocal intraocular lenses. J CATARACT REFR SURG. 2019;45(9):1258\u201364.","journal-title":"J CATARACT REFR SURG"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-026-04857-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-04857-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-04857-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T01:35:50Z","timestamp":1781228150000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12886-026-04857-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,27]]},"references-count":20,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["4857"],"URL":"https:\/\/doi.org\/10.1186\/s12886-026-04857-y","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,27]]},"assertion":[{"value":"11 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 April 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was conducted in accordance with the Declaration of Helsinki. Ethical approval was reviewed by the Institutional Review Board of the First Affiliated Hospital of Nanchang University. All of the participants signed informed consent forms.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"329"}}