{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T11:10:48Z","timestamp":1780312248994,"version":"3.54.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,5,30]],"date-time":"2026-05-30T00:00:00Z","timestamp":1780099200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T00:00:00Z","timestamp":1780272000000},"content-version":"vor","delay-in-days":2,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"the Intramural Grant of Joint Shantou International Eye Center","award":["24-008"],"award-info":[{"award-number":["24-008"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>To investigate whether anterior capsule polishing can prevent the fibrosis of the anterior capsule in phacovitrectomy without intraocular lens (IOL) implantation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods and analysis<\/jats:title>\n                    <jats:p>A retrospective study including seventy cases of phacovitrectomy without IOL implantation was conducted. Fifty cases received 360-degree anterior capsule polishing, and 20 cases did not receive polishing. The severity of anterior capsule fibrosis was calculated by adding the score (from 0 to 3) of each clock hour. The fibrosis severity was compared in the groups with and without polishing using Mann-Whitney U test. The risk factors of anterior capsule fibrosis were explored using single and multiple linear regression. The location of secondary intraocular lens implantation was compared between the polishing and non-polishing groups with Chi-square test.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The median severity score of the polishing group was significantly less than that of the non-polishing group (6 vs. 24 out of 36,\n                      <jats:bold>\n                        <jats:italic>P<\/jats:italic>\n                      <\/jats:bold>\n                      \u2009&lt;\u20090.001). Multiple regression showed that diabetes (b\u2009=\u200914.634,\n                      <jats:bold>\n                        <jats:italic>P<\/jats:italic>\n                      <\/jats:bold>\n                      \u2009=\u20090.001), silicone oil tamponade (b\u2009=\u20098.734,\n                      <jats:bold>\n                        <jats:italic>P<\/jats:italic>\n                      <\/jats:bold>\n                      \u2009&lt;\u20090.001), and non-polishing (b\u2009=\u200913.731,\n                      <jats:bold>\n                        <jats:italic>P<\/jats:italic>\n                      <\/jats:bold>\n                      \u2009&lt;\u20090.001) were the risk factors of anterior capsule fibrosis. Anterior capsule polishing was associated with a higher chance of secondary in-the-bag IOL implantation (OR\u2009=\u20094.889,\n                      <jats:bold>\n                        <jats:italic>P<\/jats:italic>\n                      <\/jats:bold>\n                      \u2009=\u20090.004).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Polishing the anterior capsule is associated with reduced fibrosis of the anterior capsule in phacovitrectomy without primary IOL implantation, and more chance of secondary in-the-bag IOL implantation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12886-026-04972-w","type":"journal-article","created":{"date-parts":[[2026,5,30]],"date-time":"2026-05-30T09:54:54Z","timestamp":1780134894000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Anterior capsule polishing prevents anterior capsule fibrosis after phacovitrectomy without intraocular lens implantation"],"prefix":"10.1186","volume":"26","author":[{"given":"Xulong","family":"Liao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qi","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuqiang","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weiqi","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrzej","family":"Grzybowski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haoyu","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,5,30]]},"reference":[{"key":"4972_CR1","first-page":"102","volume":"54","author":"VM Villegas","year":"2014","unstructured":"Villegas VM, Gold AS, Latiff A, Wildner AC, Ehlies FJ, Murray TG. Phacovitrectomy Dev Ophthalmol. 2014;54:102\u20137.","journal-title":"Phacovitrectomy Dev Ophthalmol"},{"issue":"6","key":"4972_CR2","doi-asserted-by":"publisher","first-page":"1112","DOI":"10.1097\/IAE.0000000000000061","volume":"34","author":"MI Seider","year":"2014","unstructured":"Seider MI, Michael Lahey J, Fellenbaum PS. Cost of phacovitrectomy versus vitrectomy and sequential phacoemulsification. Retina. 2014;34(6):1112\u20135.","journal-title":"Retina"},{"issue":"8","key":"4972_CR3","doi-asserted-by":"publisher","first-page":"1605","DOI":"10.1097\/IAE.0000000000003092","volume":"41","author":"G Moussa","year":"2021","unstructured":"Moussa G, Sachdev A, Mohite AA, Hero M, Ch\u2019ng SW, Andreatta W. Assessing refractive outcomes and accuracy of biometry in phacovitrectomy and sequential operations in patients with retinal detachment compared with routine cataract surgery. Retina. 2021;41(8):1605\u201311.","journal-title":"Retina"},{"issue":"8","key":"4972_CR4","doi-asserted-by":"publisher","first-page":"1408","DOI":"10.1097\/IAE.0000000000002987","volume":"43","author":"K Wu","year":"2023","unstructured":"Wu K, Zong Y, Yu J, Fang W, Jiang C, Xu G. Secondary in-the-bag intraocular lens implantation in aphakic eyes after vitrectomy and silicone oil tamponade for rhegmatogenous retinal detachment. Retina. 2023;43(8):1408\u201312.","journal-title":"Retina"},{"issue":"4","key":"4972_CR5","doi-asserted-by":"publisher","first-page":"e62381","DOI":"10.1371\/journal.pone.0062381","volume":"8","author":"L Luo","year":"2013","unstructured":"Luo L, Lin H, Chen W, Wang C, Zhang X, Tang X, et al. In-the-bag intraocular lens placement via secondary capsulorhexis with radiofrequency diathermy in pediatric aphakic eyes. PLoS ONE. 2013;8(4):e62381.","journal-title":"PLoS ONE"},{"issue":"5","key":"4972_CR6","doi-asserted-by":"publisher","first-page":"739","DOI":"10.1016\/j.jcrs.2012.02.023","volume":"38","author":"DS Grewal","year":"2012","unstructured":"Grewal DS, Basti S. Modified technique for removal of Soemmerring ring and in-the-bag secondary intraocular lens placement in aphakic eyes. J Cataract Refract Surg. 2012;38(5):739\u201342.","journal-title":"J Cataract Refract Surg"},{"issue":"12","key":"4972_CR7","doi-asserted-by":"publisher","first-page":"e66","DOI":"10.1097\/j.jcrs.0000000000000675","volume":"47","author":"YJ Liu","year":"2021","unstructured":"Liu YJ, Zhang WW, Chen FF, He ZF, Xie ZG. Reopening the severely contracted lens capsular bag post-phacovitrectomy by injecting OVD and removing the fibrous membranous material. J Cataract Refract Surg. 2021;47(12):e66\u20139.","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"4972_CR8","doi-asserted-by":"publisher","first-page":"785","DOI":"10.4103\/ijo.IJO_2088_19","volume":"68","author":"P Biswas","year":"2020","unstructured":"Biswas P, Batra S, Commentary. Anterior capsule polishing: The present perspective. Indian J Ophthalmol. 2020;68(5):785\u20136.","journal-title":"Indian J Ophthalmol"},{"issue":"9","key":"4972_CR9","doi-asserted-by":"publisher","first-page":"1513","DOI":"10.1016\/j.jcrs.2006.04.020","volume":"32","author":"M Bolz","year":"2006","unstructured":"Bolz M, Menapace R, Findl O, Sacu S, Buehl W, Wirtitsch M, et al. Effect of anterior capsule polishing on the posterior capsule opacification-inhibiting properties of a sharp-edged, 3-piece, silicone intraocular lens: three- and 5-year results of a randomized trial. J Cataract Refract Surg. 2006;32(9):1513\u201320.","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"4972_CR10","doi-asserted-by":"publisher","first-page":"e0210205","DOI":"10.1371\/journal.pone.0210205","volume":"14","author":"MY Han","year":"2019","unstructured":"Han MY, Yu AH, Yuan J, Cai XJ, Ren JB. Effect of anterior capsule polish on visual function: A meta-analysis. PLoS ONE. 2019;14(1):e0210205.","journal-title":"PLoS ONE"},{"issue":"8","key":"4972_CR11","doi-asserted-by":"publisher","first-page":"1702","DOI":"10.1038\/eye.2008.355","volume":"23","author":"SK Shah","year":"2009","unstructured":"Shah SK, Praveen MR, Kaul A, Vasavada AR, Shah GD, Nihalani BR. Impact of anterior capsule polishing on anterior capsule opacification after cataract surgery: a randomized clinical trial. Eye (Lond). 2009;23(8):1702\u20136.","journal-title":"Eye (Lond)"},{"issue":"1","key":"4972_CR12","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/j.sjopt.2010.11.006","volume":"26","author":"R Baile","year":"2012","unstructured":"Baile R, Sahasrabuddhe M, Nadkarni S, Karira V, Kelkar J. Effect of anterior capsular polishing on the rate of posterior capsule opacification: A retrospective analytical study. Saudi J Ophthalmol. 2012;26(1):101\u20134.","journal-title":"Saudi J Ophthalmol"},{"issue":"2","key":"4972_CR13","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1097\/j.jcrs.0000000000000711","volume":"48","author":"T Rossi","year":"2022","unstructured":"Rossi T, Ceccacci A, Testa G, Ruggiero A, Bonora N, D\u2019Agostino I, et al. Influence of anterior capsulorhexis shape, centration, size, and location on intraocular lens position: finite element model. J Cataract Refract Surg. 2022;48(2):222\u20139.","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"4972_CR14","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/j.jcrs.2010.07.027","volume":"37","author":"K Hayashi","year":"2011","unstructured":"Hayashi K, Yoshida M, Hirata A, Hayashi H. Anterior capsule relaxing incisions with neodymium:YAG laser for patients at high-risk for anterior capsule contraction. J Cataract Refract Surg. 2011;37(1):97\u2013103.","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"4972_CR15","doi-asserted-by":"publisher","first-page":"582","DOI":"10.1016\/S0886-3350(13)80004-1","volume":"19","author":"JA Davison","year":"1993","unstructured":"Davison JA. Capsule contraction syndrome. J Cataract Refract Surg. 1993;19(5):582\u20139.","journal-title":"J Cataract Refract Surg"},{"issue":"8","key":"4972_CR16","first-page":"13769","volume":"8","author":"Y Gao","year":"2015","unstructured":"Gao Y, Dang GF, Wang X, Duan L, Wu XY. Influences of anterior capsule polishing on effective lens position after cataract surgery: a randomized controlled trial. Int J Clin Exp Med. 2015;8(8):13769\u201375.","journal-title":"Int J Clin Exp Med"},{"issue":"5","key":"4972_CR17","first-page":"3662","volume":"15","author":"B Liu","year":"2023","unstructured":"Liu B, Zhang L, Fang S. Efficacy and safety of anterior capsule polishing in cataract patients: a meta-analysis. Am J Transl Res. 2023;15(5):3662\u201373.","journal-title":"Am J Transl Res"},{"issue":"5","key":"4972_CR18","doi-asserted-by":"publisher","first-page":"796","DOI":"10.1016\/j.jcrs.2007.01.020","volume":"33","author":"C Corydon","year":"2007","unstructured":"Corydon C, Lindholt M, Knudsen EB, Graakjaer J, Corydon TJ, Dam-Johansen M. Capsulorhexis contraction after cataract surgery: comparison of sharp anterior edge and modified anterior edge acrylic intraocular lenses. J Cataract Refract Surg. 2007;33(5):796\u20139.","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"4972_CR19","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1016\/j.ajo.2005.10.041","volume":"141","author":"S Sacu","year":"2006","unstructured":"Sacu S, Menapace R, Findl O. Effect of optic material and haptic design on anterior capsule opacification and capsulorrhexis contraction. Am J Ophthalmol. 2006;141(3):488\u201393.","journal-title":"Am J Ophthalmol"},{"issue":"1","key":"4972_CR20","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1016\/S0886-3350(13)80046-6","volume":"20","author":"CF Mathey","year":"1994","unstructured":"Mathey CF, Kohnen TB, Ensikat HJ, Koch HR. Polishing methods for the lens capsule: histology and scanning electron microscopy. J Cataract Refract Surg. 1994;20(1):64\u20139.","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"4972_CR21","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1097\/j.jcrs.0000000000000742","volume":"48","author":"C Culp","year":"2022","unstructured":"Culp C, Qu P, Jones J, Fram N, Ogawa G, Masket S, et al. Clinical and histopathological findings in the dead bag syndrome. J Cataract Refract Surg. 2022;48(2):177\u201384.","journal-title":"J Cataract Refract Surg"},{"issue":"7","key":"4972_CR22","doi-asserted-by":"publisher","first-page":"1517","DOI":"10.1016\/j.jcrs.2003.11.045","volume":"30","author":"Y Hayashi","year":"2004","unstructured":"Hayashi Y, Kato S, Fukushima H, Numaga J, Kaiya T, Tamaki Y, et al. Relationship between anterior capsule contraction and posterior capsule opacification after cataract surgery in patients with diabetes mellitus. J Cataract Refract Surg. 2004;30(7):1517\u201320.","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"4972_CR23","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1007\/s10792-025-03913-8","volume":"46","author":"C Zheng","year":"2025","unstructured":"Zheng C, Huang B, Liang H, Liao X, Grzybowski A, Chen H. Outcomes of secondary in-the-bag intraocular lens implantation following phacovitrectomy. Int Ophthalmol. 2025;46(1):40.","journal-title":"Int Ophthalmol"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-026-04972-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-04972-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-04972-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T10:51:04Z","timestamp":1780311064000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12886-026-04972-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,30]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["4972"],"URL":"https:\/\/doi.org\/10.1186\/s12886-026-04972-w","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,30]]},"assertion":[{"value":"18 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 May 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study follows the tenets of the Declaration of Helsinki. The protocol was reviewed and approved by the Ethics Committee of Joint Shantou International Eye Center of Shantou University and the Chinese University of Hong Kong [ethics approval code: EC 20250107(1)-P02]. Given the retrospective nature of the study and the anonymization of patient data, the requirement for informed consent was waived by the Ethics Committee.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not Applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"297"}}