{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T20:08:25Z","timestamp":1790712505710,"version":"4.1.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T00:00:00Z","timestamp":1781308800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T00:00:00Z","timestamp":1781568000000},"content-version":"vor","delay-in-days":3,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Medizinische Fakult\u00e4t Heidelberg der Universit\u00e4t Heidelberg"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>To compare the optical qualities of a novel enhanced monofocal intraocular lens (IOL) - Extend (Hanita), against a well-established IOL - Eyhance (ICB00, J&amp;J Vision) - through in vitro benchmarking.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Optical benchmarking was conducted using the OptiSpheric IOL PRO2 device in compliance with International Organization for Standardization (ISO) guidelines. Optical quality was assessed using the modulation transfer function (MTF), point spread function (PSF), area under the MTF (MTFa), and 1951 USAF test charts. Measurements were taken at 3.0\u00a0mm and 4.5\u00a0mm apertures using a model cornea that induced 0.13\u00a0\u03bcm of spherical aberration to simulate clinical performance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Both IOLs demonstrated comparable optical performance. At a 3\u00a0mm aperture, the Extend produced an average MTF at 50 lp\/mm of 0.38\u2009\u00b1\u20090.01, while the ICB00 produced 0.36\u2009\u00b1\u20090.01. The MTFa and derived logMAR visual acuity (VA) curves showed nearly complete overlap for defocus levels less than \u2212\u20091.25 D, with both lenses yielding identical VA at far focus (-0.09 logMAR). At higher defocus levels, the observed difference between the models accounted for &lt;\u20090.02 logMAR, which is small and below the resolution threshold of standard VA testing. Point spread function assessments revealed comparable light distribution for both IOLs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Under laboratory conditions, the Hanita Extend IOL shows comparable results to the Eyhance ICB00 regarding MTF function, USAF-Chart images, and PSF assessment.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12886-026-04973-9","type":"journal-article","created":{"date-parts":[[2026,6,13]],"date-time":"2026-06-13T09:45:27Z","timestamp":1781343927000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Monofocal intraocular lens based on the Bessel principle for improved intermediate vision: a comparative assessment"],"prefix":"10.1186","volume":"26","author":[{"given":"Frederick","family":"Kremser","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weijia","family":"Yan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ramin","family":"Khoramnia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerd Uwe","family":"Auffarth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Grzegorz","family":"\u0141abuz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,13]]},"reference":[{"issue":"10374","key":"4973_CR1","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1016\/S0140-6736(22)01839-6","volume":"401","author":"MV Cicinelli","year":"2023","unstructured":"Cicinelli MV, Buchan JC, Nicholson M, Varadaraj V, Khanna RC, Cataracts. Lancet. 2023;401(10374):377\u201389. https:\/\/doi.org\/10.1016\/S0140-6736(22)01839-6.","journal-title":"Lancet"},{"issue":"8","key":"4973_CR2","doi-asserted-by":"publisher","first-page":"538","DOI":"10.3928\/1081597X-20220707-01","volume":"38","author":"KH Wan","year":"2022","unstructured":"Wan KH, Au ACK, Kua WN, et al. Enhanced Monofocal Versus Conventional Monofocal Intraocular Lens in Cataract Surgery: A Meta-analysis. J Refract Surg. 2022;38(8):538\u201346. https:\/\/doi.org\/10.3928\/1081597X-20220707-01.","journal-title":"J Refract Surg"},{"issue":"5","key":"4973_CR3","doi-asserted-by":"publisher","first-page":"883","DOI":"10.1038\/s41433-025-03625-4","volume":"39","author":"J Fern\u00e1ndez","year":"2025","unstructured":"Fern\u00e1ndez J, Ribeiro F, Burguera N, Rodr\u00edguez-Calvo-de-Mora M, Rodr\u00edguez-Vallejo M. Visual and patient-reported outcomes of an enhanced versus monofocal intraocular lenses in cataract surgery: a systematic review and meta-analysis. Eye (Lond). 2025;39(5):883\u201398. https:\/\/doi.org\/10.1038\/s41433-025-03625-4.","journal-title":"Eye (Lond)"},{"issue":"4","key":"4973_CR4","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1007\/s40123-021-00411-9","volume":"10","author":"G \u0141abuz","year":"2021","unstructured":"\u0141abuz G, Son H-S, Naujokaitis T, Yildirim TM, Khoramnia R, Auffarth GU. Laboratory Investigation of Preclinical Visual-Quality Metrics and Halo-Size in Enhanced Monofocal Intraocular Lenses. Ophthalmol Ther. 2021;10(4):1093\u2013104. https:\/\/doi.org\/10.1007\/s40123-021-00411-9.","journal-title":"Ophthalmol Ther"},{"key":"4973_CR5","doi-asserted-by":"publisher","unstructured":"Mencucci R, Romualdi G, Carnicci A, Panini F, Buzzi M, Giansanti F. Long-term effectiveness of a monofocal intraocular lens (IOL) enhanced for intermediate vision: a 5-year follow-up study. J Clin Med. 2025;14(16). https:\/\/doi.org\/10.3390\/jcm14165831.","DOI":"10.3390\/jcm14165831"},{"issue":"9","key":"4973_CR6","doi-asserted-by":"publisher","first-page":"601","DOI":"10.3928\/1081597X-20210610-03","volume":"37","author":"ID Baur","year":"2021","unstructured":"Baur ID, Khoramnia R, Weindler J, Naujokaitis T, Poompokawat P, Auffarth GU. Clinical Outcomes of a New Hybrid Monofocal IOL With Extended Depth of Focus. J Refract Surg. 2021;37(9):601\u20138. https:\/\/doi.org\/10.3928\/1081597X-20210610-03.","journal-title":"J Refract Surg"},{"issue":"1","key":"4973_CR7","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1186\/s12886-023-02897-2","volume":"23","author":"WK Choi","year":"2023","unstructured":"Choi WK, Han HJ, Son H-S, Khoramnia R, Auffarth GU, Choi CY. Clinical outcomes of bilateral implantation of new generation monofocal IOL enhanced for intermediate distance and conventional monofocal IOL in a Korean population. BMC Ophthalmol. 2023;23(1):157. https:\/\/doi.org\/10.1186\/s12886-023-02897-2.","journal-title":"BMC Ophthalmol"},{"key":"4973_CR8","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1016\/j.ajo.2023.11.006","volume":"261","author":"V Danzinger","year":"2024","unstructured":"Danzinger V, Schartm\u00fcller D, Lisy M, et al. Intraindividual Comparison of an Enhanced Monofocal and an Aspheric Monofocal Intraocular Lens of the Same Platform. Am J Ophthalmol. 2024;261:95\u2013102. https:\/\/doi.org\/10.1016\/j.ajo.2023.11.006.","journal-title":"Am J Ophthalmol"},{"key":"4973_CR9","doi-asserted-by":"publisher","first-page":"1673","DOI":"10.2147\/OPTH.S520086","volume":"19","author":"ID Baur","year":"2025","unstructured":"Baur ID, Khoramnia R, Son H-S, Auffarth GU, \u0141abuz G. Ray Visualization and Through-Focus Optical Quality of Diffractive Enhanced Monofocal and Extended-Depth-of-Focus Intraocular Lenses. Clin Ophthalmol. 2025;19:1673\u201382. https:\/\/doi.org\/10.2147\/OPTH.S520086.","journal-title":"Clin Ophthalmol"},{"issue":"9","key":"4973_CR10","doi-asserted-by":"publisher","first-page":"698","DOI":"10.1007\/s00347-024-02064-y","volume":"121","author":"G \u0141abuz","year":"2024","unstructured":"\u0141abuz G, Khoramnia R, Naujokaitis T, Auffarth GU. Optische Bank-Evaluierung f\u00fcr spezielle Intraokularlinsenoptiken. Ophthalmologie. 2024;121(9):698\u2013705. https:\/\/doi.org\/10.1007\/s00347-024-02064-y.","journal-title":"Ophthalmologie"},{"issue":"6","key":"4973_CR11","doi-asserted-by":"publisher","first-page":"520","DOI":"10.1097\/j.jcrs.0000000000001641","volume":"51","author":"R Kabura","year":"2025","unstructured":"Kabura R, Takeshita T, Furushima K, et al. Comparative evaluation of clinical results and patient-reported outcomes of enhanced monofocal and conventional monofocal intraocular lenses. J Cataract Refract Surg. 2025;51(6):520\u20134. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001641.","journal-title":"J Cataract Refract Surg"},{"key":"4973_CR12","doi-asserted-by":"publisher","first-page":"3283","DOI":"10.2147\/OPTH.S541269","volume":"19","author":"J Ota","year":"2025","unstructured":"Ota J, Matsunaga M, Haga F, et al. Enhanced Monofocal IOLs Improve Patient Satisfaction in Phaco-Vitrectomy for ERM. Clin Ophthalmol. 2025;19:3283\u201393. https:\/\/doi.org\/10.2147\/OPTH.S541269.","journal-title":"Clin Ophthalmol"},{"key":"4973_CR13","doi-asserted-by":"publisher","unstructured":"Dorronzoro-Ramirez E, Sanchez-Tena MA, Alvarez-Peregrina C, Cardenas Rebollo JM, Flores Cervantes D, S\u00e1nchez-Ramos C. Visual outcomes of a non-diffractive extended depth-of-focus intraocular lens in patients with early-stage age-related macular degeneration. J Clin Med. 2025;14(17). https:\/\/doi.org\/10.3390\/jcm14175953.","DOI":"10.3390\/jcm14175953"},{"key":"4973_CR14","doi-asserted-by":"publisher","first-page":"3515","DOI":"10.2147\/OPTH.S549693","volume":"19","author":"F Mayordomo-Cerd\u00e1","year":"2025","unstructured":"Mayordomo-Cerd\u00e1 F, Ortega-Usobiaga J, Bilbao-Calabuig R, et al. Satisfaction and Visual and Refractive Outcomes Combining an Enhanced Monofocal and a Trifocal Intraocular Lens in Patients with Specific Visual Demands. Clin Ophthalmol. 2025;19:3515\u201326. https:\/\/doi.org\/10.2147\/OPTH.S549693.","journal-title":"Clin Ophthalmol"},{"issue":"2","key":"4973_CR15","doi-asserted-by":"publisher","first-page":"181","DOI":"10.4103\/IJO.IJO_681_23","volume":"72","author":"G Singh","year":"2024","unstructured":"Singh G, Sidhharthan KS, Reddy JK, Sundaram V, Thulasidas M. Comparison of visual outcomes in patients implanted with Tecnis Eyhance ICB00 and 1-Piece ZCB00 monofocal intraocular lenses. Indian J Ophthalmol. 2024;72(2):181\u20134. https:\/\/doi.org\/10.4103\/IJO.IJO_681_23.","journal-title":"Indian J Ophthalmol"},{"issue":"11","key":"4973_CR16","doi-asserted-by":"publisher","first-page":"979","DOI":"10.1097\/j.jcrs.0000000000001734","volume":"51","author":"S Hayashi","year":"2025","unstructured":"Hayashi S, Yoshida M, Hayashi K, Negishi K. Comparison of visual performance among three higher-order aspheric enhanced monofocal intraocular lenses and a standard aspheric monofocal lens. J Cataract Refract Surg. 2025;51(11):979\u201385. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001734.","journal-title":"J Cataract Refract Surg"},{"key":"4973_CR17","doi-asserted-by":"publisher","unstructured":"Mencucci R, Morelli A, Cennamo M, Roszkowska AM, Favuzza E. Enhanced monofocal intraocular lenses: a retrospective, comparative study between three different models. J Clin Med. 2023;12(10). https:\/\/doi.org\/10.3390\/jcm12103588.","DOI":"10.3390\/jcm12103588"},{"issue":"8","key":"4973_CR18","doi-asserted-by":"publisher","first-page":"818","DOI":"10.1097\/j.jcrs.0000000000001224","volume":"49","author":"R Donoso","year":"2023","unstructured":"Donoso R, Torres A, Klagges J, et al. Enhanced vs conventional monofocal intraocular lens clinical results in patients with cataract: randomized clinical trial. J Cataract Refract Surg. 2023;49(8):818\u201325. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001224.","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"4973_CR19","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1007\/s00347-024-02071-z","volume":"121","author":"GU Auffarth","year":"2024","unstructured":"Auffarth GU, \u0141abuz G, Khoramnia R, Yildirim TM. \u00dcbersicht \u00fcber Intraokularlinsen mit Presbyopie-korrigierenden Optiken. Ophthalmologie. 2024;121(9):685\u201397. https:\/\/doi.org\/10.1007\/s00347-024-02071-z.","journal-title":"Ophthalmologie"},{"key":"4973_CR20","unstructured":"The International Organization for Standardization. ISO-11979-2, Ophthalmic implants - intraocular lenses - Part 2: Optical properties and test methods. 2024."},{"key":"4973_CR21","doi-asserted-by":"crossref","unstructured":"Wang L, Dai E, Koch DD, Nathoo A. Optical aberrations of the human anterior cornea. J Cataract Refract Surg. 2003;29(8):1514\u201321.","DOI":"10.1016\/S0886-3350(03)00467-X"},{"key":"4973_CR22","doi-asserted-by":"publisher","first-page":"578508","DOI":"10.2147\/OPTH.S578508","volume":"20","author":"H-S Son","year":"2026","unstructured":"Son H-S, Labuz G, Bl\u00f6ck L, et al. Normative Data of Higher-Order Aberrations in Healthy Caucasian Eyes and Their Correlation with Age, Gender, and Spherical Equivalent. Clin Ophthalmol. 2026;20:578508. https:\/\/doi.org\/10.2147\/OPTH.S578508.","journal-title":"Clin Ophthalmol"},{"issue":"9","key":"4973_CR23","doi-asserted-by":"publisher","first-page":"e0222297","DOI":"10.1371\/journal.pone.0222297","volume":"14","author":"H Asano","year":"2019","unstructured":"Asano H, Hiraoka T, Seki Y, et al. Distribution of corneal spherical aberration in a Tanzanian population. PLoS ONE. 2019;14(9):e0222297. https:\/\/doi.org\/10.1371\/journal.pone.0222297.","journal-title":"PLoS ONE"},{"issue":"8","key":"4973_CR24","doi-asserted-by":"publisher","first-page":"520","DOI":"10.3928\/1081597X-20200612-01","volume":"36","author":"A Alarcon","year":"2020","unstructured":"Alarcon A, C\u00e1novas C, Koopman B, Weeber H, Auffarth GU, Piers PA. Enhancing the Intermediate Vision of Monofocal Intraocular Lenses Using a Higher Order Aspheric Optic. J Refract Surg. 2020;36(8):520\u20137. https:\/\/doi.org\/10.3928\/1081597X-20200612-01.","journal-title":"J Refract Surg"},{"key":"4973_CR25","doi-asserted-by":"publisher","unstructured":"Baur ID, Auffarth GU, Yan W, \u0141abuz G, Khoramnia R. Visualization of ray propagation through extended depth-of-focus intraocular lenses. Diagnostics (Basel). 2022;12(11). https:\/\/doi.org\/10.3390\/diagnostics12112667.","DOI":"10.3390\/diagnostics12112667"},{"issue":"2","key":"4973_CR26","doi-asserted-by":"publisher","first-page":"111","DOI":"10.3928\/1081597X-20221207-02","volume":"39","author":"W Yan","year":"2023","unstructured":"Yan W, \u0141abuz G, Khoramnia R, Auffarth GU. Trifocal Intraocular Lens Selection: Predicting Visual Function From Optical Quality Measurements. J Refract Surg. 2023;39(2):111\u20138. https:\/\/doi.org\/10.3928\/1081597X-20221207-02.","journal-title":"J Refract Surg"},{"issue":"8","key":"4973_CR27","doi-asserted-by":"publisher","first-page":"794","DOI":"10.1097\/j.jcrs.0000000000001502","volume":"50","author":"F Ribeiro","year":"2024","unstructured":"Ribeiro F, Dick HB, Kohnen T, et al. Evidence-based functional classification of simultaneous vision intraocular lenses: seeking a global consensus by the ESCRS Functional Vision Working Group. J Cataract Refract Surg. 2024;50(8):794\u20138. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001502.","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"4973_CR28","doi-asserted-by":"publisher","first-page":"367","DOI":"10.1007\/s00417-016-3566-9","volume":"255","author":"A Bari\u0161i\u0107","year":"2017","unstructured":"Bari\u0161i\u0107 A, Patel S, Gabric N, Feinbaum CG. The clinical depth of field achievable with trifocal and monofocal intraocular lenses: theoretical considerations and proof of concept clinical results. Graefes Arch Clin Exp Ophthalmol. 2017;255(2):367\u201373. https:\/\/doi.org\/10.1007\/s00417-016-3566-9.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"issue":"3","key":"4973_CR29","doi-asserted-by":"publisher","first-page":"430","DOI":"10.1016\/j.jcrs.2006.10.051","volume":"33","author":"JF Alfonso","year":"2007","unstructured":"Alfonso JF, Fern\u00e1ndez-Vega L, Baamonde MB, Mont\u00e9s-Mic\u00f3 R. Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens. J Cataract Refract Surg. 2007;33(3):430\u20138. https:\/\/doi.org\/10.1016\/j.jcrs.2006.10.051.","journal-title":"J Cataract Refract Surg"},{"issue":"12","key":"4973_CR30","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1167\/18.12.5","volume":"18","author":"JF Zapata-D\u00edaz","year":"2018","unstructured":"Zapata-D\u00edaz JF, Mar\u00edn-Franch I, Radhakrishnan H, L\u00f3pez-Gil N. Impact of higher-order aberrations on depth-of-field. J Vis. 2018;18(12):5. https:\/\/doi.org\/10.1167\/18.12.5.","journal-title":"J Vis"},{"key":"4973_CR31","doi-asserted-by":"publisher","first-page":"3739","DOI":"10.2147\/OPTH.S441172","volume":"17","author":"JM Micheletti","year":"2023","unstructured":"Micheletti JM, McCauley MB, Duncan N, Hall B. Biometric Indicators for Maximizing Intermediate Vision with a Monofocal IOL. Clin Ophthalmol. 2023;17:3739\u201346. https:\/\/doi.org\/10.2147\/OPTH.S441172.","journal-title":"Clin Ophthalmol"},{"key":"4973_CR32","doi-asserted-by":"publisher","unstructured":"Pieh S, Artmayr C, Schartm\u00fcller D, Kriechbaum K. IOL decentration sensitivity according to spatial frequencies. BMJ Open Ophth. 2024;9(1). https:\/\/doi.org\/10.1136\/bmjophth-2024-001661.","DOI":"10.1136\/bmjophth-2024-001661"},{"issue":"5","key":"4973_CR33","doi-asserted-by":"publisher","first-page":"848","DOI":"10.1016\/j.jcrs.2007.01.035","volume":"33","author":"GHH Beiko","year":"2007","unstructured":"Beiko GHH, Haigis W, Steinmueller A. Distribution of corneal spherical aberration in a comprehensive ophthalmology practice and whether keratometry can predict aberration values. J Cataract Refract Surg. 2007;33(5):848\u201358. https:\/\/doi.org\/10.1016\/j.jcrs.2007.01.035.","journal-title":"J Cataract Refract Surg"},{"key":"4973_CR34","doi-asserted-by":"publisher","first-page":"4571","DOI":"10.2147\/OPTH.S288738","volume":"14","author":"RS Elkitkat","year":"2020","unstructured":"Elkitkat RS, Fouad YA, Shams A, Hamza I. Normative Values of Corneal Spherical Aberration, Pupil Size, and Other Key Refractive and Topographic Parameters in a Large Cohort of Egyptian Cataract Surgery Candidates. Clin Ophthalmol. 2020;14:4571\u20137. https:\/\/doi.org\/10.2147\/OPTH.S288738.","journal-title":"Clin Ophthalmol"},{"issue":"10","key":"4973_CR35","doi-asserted-by":"publisher","first-page":"6073","DOI":"10.1364\/BOE.533714","volume":"15","author":"G \u0141abuz","year":"2024","unstructured":"\u0141abuz G, Yan W, Khoramnia R, Auffarth GU. Through-focus performance and off-axis effects in aspheric monofocal intraocular lenses. Biomed Opt Express. 2024;15(10):6073\u201382. https:\/\/doi.org\/10.1364\/BOE.533714.","journal-title":"Biomed Opt Express"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-026-04973-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-04973-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-04973-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T10:46:06Z","timestamp":1781606766000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12886-026-04973-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,13]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["4973"],"URL":"https:\/\/doi.org\/10.1186\/s12886-026-04973-9","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-9215734\/v1","asserted-by":"object"}]},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,13]]},"assertion":[{"value":"24 March 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Due to the in vitro nature of this study, without the involvement of any patients nor their personal data need for approval was waived.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors have no proprietary or commercial interest in any materials discussed in this article. GU Auffarth reports grants, personal fees, nonfinancial support and consulting fees from Alcon, Johnson & Johnson, Carl Zeiss Meditec, Rayner and SIFI, grants, personal fees, and nonfinancial support from Hoya, Kowa, Teleon and Santen, grants, personal fees and consulting fees from Cristalens and VSY, grants and personal fees from Bausch + Lomb, Biotech and Oculus, personal fees from Eyebright, grants from Contamac, Croma, Hanita, Ophtec and Physiol, outside the submitted work. R Khoramnia reports grants, personal fees and nonfinancial support from Alcon and Teleon; grants, personal fees and nonfinancial support from Hoya and Johnson&Johnson, grants and personal fees from Bausch + Lomb, personal fees and nonfinancial support from Carl Zeiss Meditec and Ophtec, personal fees from Heidelberg Engineering, Oculus and Rayner, outside the submitted work. G \u0141abuz reports nonfinancial support from Contamac and Alcon outside the submitted work. The University of Heidelberg holds a patent application (No. EP22187235) entitled \u201cLens with extended depth of focus by inducing an excess of longitudinal chromatic aberration\u201d, with GU Auffarth and G \u0141abuz as inventors. The remaining authors have nothing to disclose.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"336"}}