{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:40:29Z","timestamp":1786120829034,"version":"build-2736575974"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T00:00:00Z","timestamp":1780444800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T00:00:00Z","timestamp":1786060800000},"content-version":"vor","delay-in-days":65,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>This study aimed to evaluate the agreement and interchangeability between a spectral-domain optical coherence tomography (SD-OCT)-based biometer (REVO FC) and a partial coherence interferometry (PCI) device (AL Scan).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This prospective comparative cross-sectional study included 60 right eyes of 60 patients aged 40\u201382 years, diagnosed with senile cataracts. Measurements of axial length (AL), anterior chamber depth (ACD), keratometry (K1, K2), and astigmatism vector components (J0, J45) were conducted using both devices. Paired comparisons were performed using appropriate statistical tests. Agreement was evaluated using Bland\u2013Altman analysis, while correlation and reliability were assessed using Pearson correlation coefficients and interclass correlation coefficients (ICC).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      No statistically significant differences were observed in AL (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.507) or ACD (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.218), with excellent correlations (AL:\n                      <jats:italic>r<\/jats:italic>\n                      \u2009=\u20090.998; ACD:\n                      <jats:italic>r<\/jats:italic>\n                      \u2009=\u20090.945). Bland\u2013Altman analysis demonstrated excellent agreement for AL measurements, with a mean difference (bias) of \u2212\u20090.01\u00a0mm and narrow 95% limits of agreement (LoA: \u22120.245 to 0.225\u00a0mm). For ACD, the mean difference was 0.02\u00a0mm, with a moderately wider LoA (\u2212\u20090.244 to 0.288\u00a0mm), indicating an acceptable but less robust agreement compared to AL. The keratometric values were significantly higher with REVO FC (K1: +0.76 D; K2: +0.94 D; both\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001), indicating a systematic bias. Despite strong correlations (K1:\n                      <jats:italic>r<\/jats:italic>\n                      \u2009=\u20090.980; K2:\n                      <jats:italic>r<\/jats:italic>\n                      \u2009=\u20090.924), the Bland\u2013Altman analysis revealed wide limits of agreement. J0 exhibited no significant difference (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.889), whereas J45 differed significantly (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.028). Both vector components demonstrated moderate agreement, with relatively wide limits of agreement.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>REVO FC and AL Scan demonstrate excellent agreement for AL and ACD measurements and may be used interchangeably for these parameters. However, significant discrepancies in keratometric and astigmatic measurements limit their interchangeability.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12886-026-04979-3","type":"journal-article","created":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T11:55:14Z","timestamp":1780487714000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Comparison of spectral-domain optical coherence tomography biometry measurements with partial coherence interferometry optical biometry"],"prefix":"10.1186","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3839-5699","authenticated-orcid":false,"given":"Konuralp","family":"Yakar","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1759-9753","authenticated-orcid":false,"given":"G\u00f6khan","family":"\u00d6zg\u00fcr","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,3]]},"reference":[{"key":"4979_CR1","doi-asserted-by":"publisher","first-page":"1191","DOI":"10.2147\/OPTH.S464538","volume":"18","author":"M Pathak","year":"2024","unstructured":"Pathak M, Sahu V, Kumar A, Kaur K, Gurnani B. Current Concepts and Recent Updates of Optical Biometry: A Comprehensive Review. Clin Ophthalmol. 2024;18:1191\u2013206.","journal-title":"Clin Ophthalmol"},{"issue":"7","key":"4979_CR2","doi-asserted-by":"publisher","first-page":"819","DOI":"10.1097\/j.jcrs.0000000000000865","volume":"48","author":"DL Cooke","year":"2022","unstructured":"Cooke DL, Waldron R, Savini G, Riaz KM, Taroni L, Murphy DA, Guaraldi F. Immersion ultrasound biometry vs optical biometry. J Cataract Refract Surg. 2022;48(7):819\u201325.","journal-title":"J Cataract Refract Surg"},{"issue":"12","key":"4979_CR3","doi-asserted-by":"publisher","first-page":"e0316439","DOI":"10.1371\/journal.pone.0316439","volume":"19","author":"H Park","year":"2024","unstructured":"Park H, Yoo YS, Shin E, Song WS, Won Y, Chung TY, Lim DH. Comparison of ocular biometry and refractive outcomes using two swept-source optical coherence tomography-based biometers. PLoS ONE. 2024;19(12):e0316439.","journal-title":"PLoS ONE"},{"issue":"1","key":"4979_CR4","doi-asserted-by":"publisher","first-page":"410","DOI":"10.1186\/s12886-024-03658-5","volume":"24","author":"RET Ang","year":"2024","unstructured":"Ang RET, Estolano BL, Luz PHC, Umali MIN, Araneta MMQ, Cruz EM. Comparison of measurements and calculated lens power using three biometers: a Scheimpflug tomographer with partial coherence interferometry and two swept source optical coherence tomographers. BMC Ophthalmol. 2024;24(1):410.","journal-title":"BMC Ophthalmol"},{"issue":"10","key":"4979_CR5","doi-asserted-by":"publisher","first-page":"694","DOI":"10.3928\/1081597X-20160712-03","volume":"32","author":"KJ Hoffer","year":"2016","unstructured":"Hoffer KJ, Savini G. Comparison of AL Scan and IOLMaster 500 Partial Coherence Interferometry Optical Biometers. J Refract Surg. 2016;32(10):694\u201398.","journal-title":"J Refract Surg"},{"issue":"4","key":"4979_CR6","doi-asserted-by":"publisher","first-page":"288","DOI":"10.4103\/0974-9233.194075","volume":"23","author":"E Can","year":"2016","unstructured":"Can E, Duran M, \u00c7etinkaya T, Ar\u0131t\u00fcrk N. Comparison of Anterior Segment Measurements with Optical Low-coherence Reflectometry and Partial-coherence Interferometry Optical Biometers. Middle East Afr J Ophthalmol. 2016;23(4):288\u201392.","journal-title":"Middle East Afr J Ophthalmol"},{"issue":"3","key":"4979_CR7","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1007\/s10792-016-0284-6","volume":"37","author":"\u00c7 \u00c7a\u011flar","year":"2017","unstructured":"\u00c7a\u011flar \u00c7, Kocam\u0131\u015f S\u0130, Demir E, Durmu\u015f M. Comparison of the measurements of a novel optical biometry: Nidek AL Scan with Sirius and a ultrasound biometry. Int Ophthalmol. 2017;37(3):491\u20138.","journal-title":"Int Ophthalmol"},{"issue":"1","key":"4979_CR8","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1186\/s12886-026-04658-3","volume":"26","author":"J Tubis","year":"2026","unstructured":"Tubis J, Zaj\u0105czkowska Z, Kanclerz P. Comparison of corneal thickness measured using the new Revo FC optical coherence tomographer and the pentacam Scheimpflug-based imaging system. BMC Ophthalmol. 2026;26(1):115.","journal-title":"BMC Ophthalmol"},{"issue":"1","key":"4979_CR9","doi-asserted-by":"publisher","first-page":"25252","DOI":"10.1038\/s41598-024-77177-0","volume":"14","author":"W Long","year":"2024","unstructured":"Long W, Ong A, Zheng B, Liang Z, Cui D. Comparative analysis of a novel spectral-domain OCT biometer versus swept-source OCT or OLCR biometer in healthy pediatric ocular biometry. Sci Rep. 2024;14(1):25252.","journal-title":"Sci Rep"},{"issue":"12","key":"4979_CR10","doi-asserted-by":"publisher","first-page":"2095","DOI":"10.18240\/ijo.2023.12.24","volume":"16","author":"S Sardari","year":"2023","unstructured":"Sardari S, Fotouhi A, Jafarzadehpur E, Khabazkhoob M. Agreements\u2019 profile of Scheimpflug-based optical biometer with gold standard partial coherence interferometry. Int J Ophthalmol. 2023;16(12):2095\u2013104.","journal-title":"Int J Ophthalmol"},{"issue":"3","key":"4979_CR11","first-page":"46","volume":"8","author":"N Rizzieri","year":"2024","unstructured":"Rizzieri N, Facchin A. Comparison of eye axial length measurements taken using partial coherence interferometry and OCT biometry. Vision (Basel). 2024;8(3):46.","journal-title":"Vis (Basel)"},{"issue":"1","key":"4979_CR12","doi-asserted-by":"publisher","first-page":"107","DOI":"10.4103\/ijo.IJO_854_21","volume":"70","author":"S Gonz\u00e1lez-God\u00ednez","year":"2022","unstructured":"Gonz\u00e1lez-God\u00ednez S, Saucedo-Urdapilleta R, Mayorqu\u00edn-Ruiz M, Velasco-Barona C, Moragrega-Adame E, Dom\u00ednguez-Varela IA, Gonzalez-Salinas R. Ocular biometry in dense cataracts: Comparison of partial-coherence interferometry, swept-source optical coherence tomography and immersion ultrasound. Indian J Ophthalmol. 2022;70(1):107\u201311.","journal-title":"Indian J Ophthalmol"},{"issue":"7","key":"4979_CR13","doi-asserted-by":"publisher","first-page":"748","DOI":"10.1080\/08164622.2023.2277287","volume":"107","author":"M Aldaba","year":"2024","unstructured":"Aldaba M, Ochando P, Vila-Vidal N, Vinuela-Navarro V, Guisasola L, Perez-Corral J. Precision and agreement of axial length in paediatric population measured with MYAH and AL Scan biometers. Clin Exp Optom. 2024;107(7):748\u201353.","journal-title":"Clin Exp Optom"},{"issue":"3","key":"4979_CR14","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1097\/IIO.0000000000000175","volume":"57","author":"R Guimar\u00e3es de Souza","year":"2017","unstructured":"Guimar\u00e3es de Souza R, Montes de Oca I, Esquenazi I, Al-Mohtaseb Z, Weikert MP. Updates in Biometry. Int Ophthalmol Clin. 2017;57(3):115\u201324.","journal-title":"Int Ophthalmol Clin"},{"issue":"6","key":"4979_CR15","doi-asserted-by":"publisher","first-page":"802","DOI":"10.1097\/j.jcrs.0000000000000551","volume":"47","author":"R Mont\u00e9s-Mic\u00f3","year":"2021","unstructured":"Mont\u00e9s-Mic\u00f3 R, Pastor-Pascual F, Ruiz-Mesa R, Ta\u00f1\u00e1-Rivero P. Ocular biometry with swept-source optical coherence tomography. J Cataract Refract Surg. 2021;47(6):802\u201314.","journal-title":"J Cataract Refract Surg"},{"key":"4979_CR16","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1016\/j.jcrs.2013.09.020","volume":"40","author":"S Srivannaboon","year":"2014","unstructured":"Srivannaboon S, Chirapapaisan C, Chonpimai P, et al. Comparison of ocular biometry and intraocular lens power using a new biometer and a standard biometer. J Cataract Refract Surg. 2014;40:709\u201315.","journal-title":"J Cataract Refract Surg"},{"key":"4979_CR17","doi-asserted-by":"publisher","first-page":"1277","DOI":"10.1136\/bjophthalmol-2014-305150","volume":"98","author":"J Huang","year":"2014","unstructured":"Huang J, Savini G, Li J, et al. Evaluation of a new optical biometry device for measurements of ocular components and its comparison with IOLMaster. Br J Ophthalmol. 2014;98:1277\u201381.","journal-title":"Br J Ophthalmol"},{"key":"4979_CR18","first-page":"6347236","volume":"2016","author":"J Huang","year":"2016","unstructured":"Huang J, et al. Comparison between a New Optical Biometry Device and an Anterior Segment Optical Coherence Tomographer for Measuring Central Corneal Thickness and Anterior Chamber Depth. J Ophthalmol. 2016;2016:6347236.","journal-title":"J Ophthalmol"},{"issue":"1","key":"4979_CR19","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1097\/ICL.0000000000000603","volume":"46","author":"TCY Chan","year":"2020","unstructured":"Chan TCY, Wan KH, Tang FY, Wang YM, Yu M, Cheung C. Repeatability and Agreement of a Swept-Source Optical Coherence Tomography-Based Biometer IOLMaster 700 Versus a Scheimpflug Imaging-Based Biometer AL Scan in Cataract Patients. Eye Contact Lens. 2020;46(1):35\u201345.","journal-title":"Eye Contact Lens"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-026-04979-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-04979-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-04979-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T01:28:24Z","timestamp":1786066104000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12886-026-04979-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,3]]},"references-count":19,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["4979"],"URL":"https:\/\/doi.org\/10.1186\/s12886-026-04979-3","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,3]]},"assertion":[{"value":"12 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This prospective comparative study was conducted in accordance with the guidelines of the Declaration of Helsinki. The study received ethical approval from Samsun University (Approval No: GOKAEK 2025\/11\/10). Informed consent was obtained from all participants for the use of prospective data in this study.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"473"}}