{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T13:23:29Z","timestamp":1787664209395,"version":"build-2736575974"},"reference-count":7,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T00:00:00Z","timestamp":1781568000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T00:00:00Z","timestamp":1787616000000},"content-version":"vor","delay-in-days":70,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"DOI":"10.1186\/s12886-026-04981-9","type":"journal-article","created":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T10:33:56Z","timestamp":1781606036000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Management of sliding suction loss during keratorefractive lenticule extraction performed with VisuMax 800 femtosecond laser using CIRCLE software: a case report"],"prefix":"10.1186","volume":"26","author":[{"given":"Bu Ki","family":"Kim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Young Taek","family":"Chung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,16]]},"reference":[{"key":"4981_CR1","doi-asserted-by":"publisher","first-page":"2711","DOI":"10.4103\/ijo.IJO_3258_20","volume":"68","author":"MI Asif","year":"2020","unstructured":"Asif MI, Bafna RK, Mehta JS, Reddy J, Titiyal JS, Maharana PK, et al. Complications of small incision lenticule extraction. Indian J Ophthalmol. 2020;68:2711\u201322.","journal-title":"Indian J Ophthalmol"},{"key":"4981_CR2","doi-asserted-by":"publisher","first-page":"25484","DOI":"10.1038\/s41598-025-98041-9","volume":"15","author":"BK Kim","year":"2025","unstructured":"Kim BK, Chung YT. Comparison of clinical outcomes following small incision lenticule extraction performed with the visumax 800 versus visumax 500 femtosecond laser. Sci Rep. 2025;15:25484.","journal-title":"Sci Rep"},{"key":"4981_CR3","doi-asserted-by":"publisher","first-page":"e72","DOI":"10.1111\/aos.14215","volume":"98","author":"DZ Reinstein","year":"2020","unstructured":"Reinstein DZ, Archer TJ, Vida RS, Carp GI. Suction stability management in small incision lenticule extraction: incidence and outcomes of suction loss in 4000 consecutive procedures. Acta Ophthalmol. 2020;98:e72\u201380.","journal-title":"Acta Ophthalmol"},{"key":"4981_CR4","doi-asserted-by":"publisher","first-page":"511","DOI":"10.2147\/OPTH.S133188","volume":"11","author":"AA Gab-Alla","year":"2017","unstructured":"Gab-Alla AA. Refraction outcomes after suction loss during small-incision lenticule extraction (SMILE). Clin Ophthalmol. 2017;11:511\u20135.","journal-title":"Clin Ophthalmol"},{"key":"4981_CR5","first-page":"1","volume":"7","author":"GS Sachdev","year":"2019","unstructured":"Sachdev GS, Sachdev MS. Circle software for management of suction loss during small-incision lenticule extraction. J Cataract Refract Surg Case Rep. 2019;7:1\u20132.","journal-title":"J Cataract Refract Surg Case Rep"},{"key":"4981_CR6","doi-asserted-by":"publisher","first-page":"236","DOI":"10.3928\/1081597X-20130318-02","volume":"29","author":"AK Riau","year":"2013","unstructured":"Riau AK, Ang HP, Lwin NC, Chaurasia SS, Tan DT, Mehta JS. Comparison of four different VisuMax circle patterns for flap creation after small incision lenticule extraction. J Refract Surg. 2013;29:236\u201344.","journal-title":"J Refract Surg"},{"key":"4981_CR7","doi-asserted-by":"publisher","first-page":"60","DOI":"10.3928\/1081597X-20181120-01","volume":"35","author":"S Ganesh","year":"2019","unstructured":"Ganesh S, Brar S, Manasa KV. CIRCLE software for the management of retained lenticule tissue following complicated SMILE surgery. J Refract Surg. 2019;35:60\u20135.","journal-title":"J Refract Surg"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-026-04981-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-04981-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-04981-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T13:02:55Z","timestamp":1787662975000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12886-026-04981-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,16]]},"references-count":7,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["4981"],"URL":"https:\/\/doi.org\/10.1186\/s12886-026-04981-9","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-9285820\/v1","asserted-by":"object"}]},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,16]]},"assertion":[{"value":"1 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 May 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Written informed consent was obtained from the patient for publication of this case report and any accompanying images.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"520"}}