{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T05:54:52Z","timestamp":1781589292772,"version":"3.54.5"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,15]],"date-time":"2026-06-15T00:00:00Z","timestamp":1781481600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T00:00:00Z","timestamp":1781568000000},"content-version":"vor","delay-in-days":1,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"the Natural Science Foundation of Fujian Province","award":["No. 2023J01591"],"award-info":[{"award-number":["No. 2023J01591"]}]},{"name":"the Science and Technology Innovation Joint Fund Project of the Fujian Provincial Department of Science and Technology","award":["No. 2023Y9027"],"award-info":[{"award-number":["No. 2023Y9027"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"DOI":"10.1186\/s12886-026-04993-5","type":"journal-article","created":{"date-parts":[[2026,6,15]],"date-time":"2026-06-15T02:04:02Z","timestamp":1781489042000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Influence of angle kappa and angle alpha on visual outcomes after implantation of a nondiffractive extended-depth-of-focus intraocular lens: a prospective observation study"],"prefix":"10.1186","volume":"26","author":[{"given":"Nuozhou","family":"Wu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yihua","family":"Yao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Biting","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sinan","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yunhui","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaohui","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,15]]},"reference":[{"issue":"2","key":"4993_CR1","doi-asserted-by":"publisher","first-page":"e131","DOI":"10.3928\/1081597X-20241230-01","volume":"41","author":"F Howes","year":"2025","unstructured":"Howes F, Rementeria-Capelo LA, Poyales F, Borovik A, Khoramnia R, Perez-Vives C, et al. Visual Performance and Patient Satisfaction of Bilaterally Implanted Extended Depth of Focus Intraocular Lens: Outcomes of a Multicenter Registry. J Refract Surg. 2025;41(2):e131\u2013131143. https:\/\/doi.org\/10.3928\/1081597X-20241230-01.","journal-title":"J Refract Surg"},{"key":"4993_CR2","doi-asserted-by":"publisher","first-page":"1161","DOI":"10.2147\/OPTH.S402069","volume":"17","author":"R Kandavel","year":"2023","unstructured":"Kandavel R, Colvard M, Dredge J, Bayle M, Alam T, Snyder J, et al. Comparative Study Between Non-Diffractive Extended Depth of Focus and Monofocal Intraocular Lenses. Clin Ophthalmol. 2023;17:1161\u20138. https:\/\/doi.org\/10.2147\/OPTH.S402069.","journal-title":"Clin Ophthalmol"},{"issue":"11","key":"4993_CR3","doi-asserted-by":"publisher","first-page":"1297","DOI":"10.1097\/j.jcrs.0000000000000978","volume":"48","author":"C McCabe","year":"2022","unstructured":"McCabe C, Berdahl J, Reiser H, Newsom TH, Cibik L, Koch D, et al. Clinical outcomes in a U.S. registration study of a new EDOF intraocular lens with a nondiffractive design. J Cataract Refract Surg. 2022;48(11):1297\u2013304. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000978.","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"4993_CR4","doi-asserted-by":"publisher","first-page":"1258","DOI":"10.1016\/j.jcrs.2019.04.003","volume":"45","author":"Y Fu","year":"2019","unstructured":"Fu Y, Kou J, Chen D, Wang D, Zhao Y, Hu M, et al. Influence of angle kappa and angle alpha on visual quality after implantation of multifocal intraocular lenses. J Cataract Refract Surg. 2019;45(9):1258\u201364. https:\/\/doi.org\/10.1016\/j.jcrs.2019.04.003.","journal-title":"J Cataract Refract Surg"},{"issue":"9","key":"4993_CR5","doi-asserted-by":"publisher","first-page":"1187","DOI":"10.1038\/eye.2011.150","volume":"25","author":"G Prakash","year":"2011","unstructured":"Prakash G, Prakash DR, Agarwal A, Kumar DA, Agarwal A, Jacob S. Predictive factor and kappa angle analysis for visual satisfactions in patients with multifocal IOL implantation. Eye (Lond). 2011;25(9):1187\u201393. https:\/\/doi.org\/10.1038\/eye.2011.150.","journal-title":"Eye (Lond)"},{"key":"4993_CR6","doi-asserted-by":"publisher","unstructured":"Chang DH, Waring GO 4. The subject-fixated coaxially sighted corneal light reflex: a clinical marker for centration of refractive treatments and devices. Am J Ophthalmol. 2014;158(5):863\u201374. https:\/\/doi.org\/10.1016\/j.ajo.2014.06.028.","DOI":"10.1016\/j.ajo.2014.06.028"},{"issue":"8","key":"4993_CR7","doi-asserted-by":"publisher","first-page":"949","DOI":"10.1016\/j.jcrs.2018.05.026","volume":"44","author":"Y Qi","year":"2018","unstructured":"Qi Y, Lin J, Leng L, Zhao G, Wang Q, Li C, et al. Role of angle \u03ba in visual quality in patients with a trifocal diffractive intraocular lens. J Cataract Refract Surg. 2018;44(8):949\u201354. https:\/\/doi.org\/10.1016\/j.jcrs.2018.05.026.","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"4993_CR8","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1186\/s12886-022-02302-4","volume":"22","author":"M Qin","year":"2022","unstructured":"Qin M, Ji M, Zhou T, Yuan Y, Luo J, Li P, et al. Influence of angle alpha on visual quality after implantation of extended depth of focus intraocular lenses. BMC Ophthalmol. 2022;22(1):82. https:\/\/doi.org\/10.1186\/s12886-022-02302-4.","journal-title":"BMC Ophthalmol"},{"issue":"5","key":"4993_CR9","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1097\/j.jcrs.0000000000000156","volume":"46","author":"N Garz\u00f3n","year":"2020","unstructured":"Garz\u00f3n N, Garc\u00eda-Montero M, L\u00f3pez-Artero E, Albarr\u00e1n-Diego C, P\u00e9rez-Cambrod\u00ed R, Illarramendi I, et al. Influence of angle \u03ba on visual and refractive outcomes after implantation of a diffractive trifocal intraocular lens. J Cataract Refract Surg. 2020;46(5):721\u20137. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000156.","journal-title":"J Cataract Refract Surg"},{"key":"4993_CR10","doi-asserted-by":"publisher","first-page":"1321","DOI":"10.2147\/OPTH.S363536","volume":"16","author":"HP Sandoval","year":"2022","unstructured":"Sandoval HP, Potvin R, Solomon KD. The Effects of Angle Kappa on Clinical Results and Patient-Reported Outcomes After Implantation of a Trifocal Intraocular Lens. Clin Ophthalmol. 2022;16:1321\u20139. https:\/\/doi.org\/10.2147\/OPTH.S363536.","journal-title":"Clin Ophthalmol"},{"key":"4993_CR11","doi-asserted-by":"publisher","first-page":"7018937","DOI":"10.1155\/2019\/7018937","volume":"2019","author":"C Velasco-Barona","year":"2019","unstructured":"Velasco-Barona C, Corredor-Ortega C, Mendez-Leon A, Casillas-Chavar\u00edn NL, Velarde DV, Cervantes-Coste G, et al. Influence of Angle \u03ba and Higher-Order Aberrations on Visual Quality Employing Two Diffractive Trifocal IOLs. J Ophthalmol. 2019;2019:7018937. https:\/\/doi.org\/10.1155\/2019\/7018937.","journal-title":"J Ophthalmol"},{"issue":"1","key":"4993_CR12","doi-asserted-by":"publisher","first-page":"26943","DOI":"10.1038\/s41598-025-07970-y","volume":"15","author":"A Niknahad","year":"2025","unstructured":"Niknahad A, Wu Z, Son HS, Auffarth GU, Khoramnia R, \u0141abuz G. Evaluation of Clareon Vivity and PureSee intraocular lenses: optical quality, depth of focus and misalignment effects. Sci Rep. 2025;15(1):26943. https:\/\/doi.org\/10.1038\/s41598-025-07970-y.","journal-title":"Sci Rep"},{"key":"4993_CR13","doi-asserted-by":"publisher","unstructured":"Schmid R, Luedtke H, Borkenstein AF. Effect of decentration and tilt on four novel extended range of vision intraocular lenses regarding far distance. Eur J Ophthalmol. 2022. https:\/\/doi.org\/10.1177\/11206721221128864.","DOI":"10.1177\/11206721221128864"},{"issue":"1","key":"4993_CR14","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1186\/s40662-024-00424-y","volume":"12","author":"G Savini","year":"2025","unstructured":"Savini G, Galzignato A, Coutinho CP, Huang J, Wu Y, Barboni P, et al. Influence of preoperative variables on the 3-month functional outcomes of the Vivity extended depth-of-focus intraocular lens: a prospective case series. Eye Vis (Lond). 2025;12(1):8. https:\/\/doi.org\/10.1186\/s40662-024-00424-y.","journal-title":"Eye Vis (Lond)"},{"issue":"10","key":"4993_CR15","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1097\/ICL.0000000000000931","volume":"48","author":"MY Song","year":"2022","unstructured":"Song MY, Kang KH, Lee H, Kim T, Koh K. A Comparative Study of Two Extended Depth of Focus Intraocular Lenses. Eye Contact Lens. 2022;48(10):433\u20138. https:\/\/doi.org\/10.1097\/ICL.0000000000000931.","journal-title":"Eye Contact Lens"},{"issue":"2","key":"4993_CR16","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1097\/j.jcrs.0000000000001330","volume":"50","author":"MC Fernandes","year":"2024","unstructured":"Fernandes MC, Nunomura CY, Messias A. Visual performance and photic disturbances with diffractive and nondiffractive EDOF intraocular lenses using mini-monovision: randomized trial. J Cataract Refract Surg. 2024;50(2):153\u20139. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001330.","journal-title":"J Cataract Refract Surg"},{"issue":"12","key":"4993_CR17","doi-asserted-by":"publisher","first-page":"1354","DOI":"10.1097\/j.jcrs.0000000000000988","volume":"48","author":"M Guarro","year":"2022","unstructured":"Guarro M, Sararols L, Londo\u00f1o GJ, Go\u00f1i I, V\u00e1zquez M, Ruiz S, et al. Visual disturbances produced after the implantation of 3 EDOF intraocular lenses vs 1 monofocal intraocular lens. J Cataract Refract Surg. 2022;48(12):1354\u20139. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000988.","journal-title":"J Cataract Refract Surg"},{"issue":"1","key":"4993_CR18","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1159\/000529234","volume":"8","author":"R Schmid","year":"2023","unstructured":"Schmid R, Borkenstein AF. Enhanced Depth of Focus Intraocular Lenses: Through Focus Evaluation of Wavefront-Shaping versus Diffractive Optics. Biomed Hub. 2023;8(1):25\u201330. https:\/\/doi.org\/10.1159\/000529234.","journal-title":"Biomed Hub"},{"issue":"4","key":"4993_CR19","doi-asserted-by":"publisher","first-page":"354","DOI":"10.1097\/j.jcrs.0000000000001113","volume":"49","author":"MA Scheepers","year":"2023","unstructured":"Scheepers MA, Hall B. Randomized and double-blind comparison of clinical visual outcomes of 2 EDOF intraocular lenses. J Cataract Refract Surg. 2023;49(4):354\u20139. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001113.","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"4993_CR20","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1097\/j.jcrs.0000000000000490","volume":"47","author":"J Meng","year":"2021","unstructured":"Meng J, Du Y, Wei L, Yao Y, He W, Qian D, et al. Distribution of angle \u03b1 and angle \u03ba in a population with cataract in Shanghai. J Cataract Refract Surg. 2021;47(5):579\u201384. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000490.","journal-title":"J Cataract Refract Surg"},{"key":"4993_CR21","doi-asserted-by":"publisher","first-page":"103911","DOI":"10.1016\/j.pdpdt.2023.103911","volume":"45","author":"S Dong","year":"2024","unstructured":"Dong S, Xu R, Wang Y, Xiao W, Jiao Y. Comparisons of biometric parameters measurements by OPD-SCAN \u2162 and Pentacam in cataract. Photodiagnosis Photodyn Ther. 2024;45:103911. https:\/\/doi.org\/10.1016\/j.pdpdt.2023.103911.","journal-title":"Photodiagnosis Photodyn Ther"},{"issue":"3","key":"4993_CR22","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1007\/s40123-025-01092-4","volume":"14","author":"J Fern\u00e1ndez","year":"2025","unstructured":"Fern\u00e1ndez J, Ribeiro F, Burguera N, Burguera-Gim\u00e9nez N, Rodr\u00edguez-Vallejo M. Replacing Theories with Evidence Around the Axes of the Eye in Intraocular Lens Selection: A Review for the Clinician. Ophthalmol Ther. 2025;14(3):471\u201387. https:\/\/doi.org\/10.1007\/s40123-025-01092-4.","journal-title":"Ophthalmol Ther"},{"issue":"7","key":"4993_CR23","doi-asserted-by":"publisher","first-page":"2513","DOI":"10.1007\/s10792-021-01809-x","volume":"41","author":"J Luo","year":"2021","unstructured":"Luo J, Liu Y, Wang F, Su Y, Xiao X, Du H, et al. Effect of the kappa angle on depth of focus after implantation of the TECNIS Symfony intraocular lens. Int Ophthalmol. 2021;41(7):2513\u201320. https:\/\/doi.org\/10.1007\/s10792-021-01809-x.","journal-title":"Int Ophthalmol"},{"issue":"1","key":"4993_CR24","doi-asserted-by":"publisher","first-page":"26732","DOI":"10.1038\/s41598-024-77699-7","volume":"14","author":"RET Ang","year":"2024","unstructured":"Ang RET, Doroy ZAM, Yao JAA, Cruz EM. Correlation of angle kappa and angle alpha on visual outcomes in eyes implanted with three types of multifocal intraocular lenses. Sci Rep. 2024;14(1):26732. https:\/\/doi.org\/10.1038\/s41598-024-77699-7.","journal-title":"Sci Rep"},{"issue":"1","key":"4993_CR25","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1186\/s12886-025-03884-5","volume":"25","author":"Y Zhang","year":"2025","unstructured":"Zhang Y, Zhang J, Liang C, Xu Y, Wu J, Wu J, et al. Effect of crystalline lens decentration and tilt on visual performance in eyes implanted with bifocal or extended depth of focus intraocular lenses. BMC Ophthalmol. 2025;25(1):58. https:\/\/doi.org\/10.1186\/s12886-025-03884-5.","journal-title":"BMC Ophthalmol"},{"key":"4993_CR26","doi-asserted-by":"publisher","DOI":"10.1111\/aos.17561","author":"T Kohnen","year":"2025","unstructured":"Kohnen T, Ramasubramanian V, Suryakumar R. A review of angle kappa and multifocal intraocular lenses and their effect on visual outcomes. Acta Ophthalmol. 2025. https:\/\/doi.org\/10.1111\/aos.17561.","journal-title":"Acta Ophthalmol"},{"issue":"1","key":"4993_CR27","doi-asserted-by":"publisher","first-page":"626","DOI":"10.1186\/s12886-025-04431-y","volume":"25","author":"B Li","year":"2025","unstructured":"Li B, Rao T, Tseng Y, Ma S, He L, Li X. Analysis and comparison of factors influencing post-cataract surgery kappa angle changes. BMC Ophthalmol. 2025;25(1):626. https:\/\/doi.org\/10.1186\/s12886-025-04431-y.","journal-title":"BMC Ophthalmol"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-026-04993-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-04993-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-04993-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T05:51:03Z","timestamp":1781589063000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12886-026-04993-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,15]]},"references-count":27,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["4993"],"URL":"https:\/\/doi.org\/10.1186\/s12886-026-04993-5","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,15]]},"assertion":[{"value":"13 February 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This research protocol received ethical approval from the Medical Research and Clinical Technology Application SubCommittee of the Ethics Committee of First Affiliated Hospital of Fujian Medical University (Approval No.: MTCA, FECFAH of FMU [2015]084\u2009\u2212\u20092), and all procedures strictly adhered to the ethical principles outlined in the Declaration of Helsinki. Written informed consent was obtained from all participants prior to enrollment.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"335"}}