{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T09:46:53Z","timestamp":1782899213062,"version":"3.54.5"},"reference-count":11,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T00:00:00Z","timestamp":1782777600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"vor","delay-in-days":1,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>\n                      We aimed to develop a three-dimensional\n                      <jats:bold>(<\/jats:bold>\n                      3D) printed glaucoma drainage device (GDD) surgery model and evaluate its realism and procedural performance compared with a commercially available GDD.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This prospective, simulation-based pilot feasibility study assessed preliminary face and content validity evidence for a 3D-printed GDD model. Fourteen glaucoma specialists (eight fellows and six consultants) were recruited using a convenience sample from a single tertiary eye hospital. Participants performed two simulated GDD surgeries on ovine eyes in a surgical training wet lab, first using the 3D-printed model and then using a commercially available Baerveldt glaucoma implant (BGI). Procedure time was measured using a stopwatch for comparative analysis, and participants evaluated technical realism, visual realism, and overall utility relative to the BGI on a 5-point Likert scale (1\u2009=\u2009not at all similar\/not useful at all to 5\u2009=\u2009extremely similar\/extremely useful). The study was non-randomized, and participant blinding was not feasible because of visible differences between the devices.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Total procedure duration was longer for the 3D-printed model than for the BGI (median interquartile range [IQR], 530.5 [302.5] vs. 342 [132.5] s;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001), with significantly longer times for plate insertion (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.039), tube insertion (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.001), and tube fixation (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.025), except for plate fixation (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.078). Technical realism was rated highest for plate and tube fixation, with median [IQR] scores of 4.00 [1] and 4.00 [0], respectively, and overall model utility was rated 4.00 [1]. When comparing consultants and glaucoma fellows, only BGI plate fixation time differed significantly (112.5 [101] vs. 180 [94] s;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.023).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Although procedure times were longer with the 3D-printed model than with the commercial implant, the model demonstrated acceptable moderate-to-high ratings for realism and high overall utility, supporting its potential role as a feasible simulation-based training tool for GDD surgery.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12886-026-05034-x","type":"journal-article","created":{"date-parts":[[2026,6,30]],"date-time":"2026-06-30T13:07:41Z","timestamp":1782824861000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Development and preliminary validation of a hybrid three-dimension printed model for glaucoma drainage device surgery training: a prospective simulation-based study"],"prefix":"10.1186","volume":"26","author":[{"given":"Adi Mohammed","family":"Al Owaifeer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed","family":"Al-Yahya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed Mashary","family":"Allubly","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Khalid Ali","family":"Alalmaee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anas","family":"Alqurashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdulrahman","family":"AlKaff","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sami","family":"AlShahwan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,30]]},"reference":[{"key":"5034_CR1","doi-asserted-by":"publisher","first-page":"1318","DOI":"10.18240\/ijo.2020.08.20","volume":"13","author":"P Agrawal","year":"2020","unstructured":"Agrawal P, Bhardwaj P. Glaucoma drainage implants. Int J Ophthalmol. 2020;13:1318\u201328.","journal-title":"Int J Ophthalmol"},{"key":"5034_CR2","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1016\/j.jcjo.2016.04.021","volume":"51","author":"EY Liu","year":"2016","unstructured":"Liu EY, Li B, Hutnik CML. Canadian ophthalmic microsurgery course: an innovative spin on wet lab\u2013based surgical education. Can J Ophthalmol. 2016;51:315\u201320.","journal-title":"Can J Ophthalmol"},{"key":"5034_CR3","doi-asserted-by":"publisher","first-page":"324","DOI":"10.1016\/j.sjopt.2018.01.003","volume":"32","author":"S Alwadani","year":"2018","unstructured":"Alwadani S. Cataract surgery training using surgical simulators and wet-labs: course description and literature review. Saudi J Ophthalmol. 2018;32:324\u20139.","journal-title":"Saudi J Ophthalmol"},{"key":"5034_CR4","doi-asserted-by":"publisher","first-page":"1537","DOI":"10.1038\/s41433-018-0093-4","volume":"32","author":"AM Porteous","year":"2018","unstructured":"Porteous AM, Ahmed F. A novel wet-lab teaching model for trabeculectomy surgery. Eye. 2018;32:1537\u201350.","journal-title":"Eye"},{"key":"5034_CR5","doi-asserted-by":"publisher","first-page":"e31","DOI":"10.1016\/j.jaapos.2019.10.008","volume":"24","author":"L Jagan","year":"2020","unstructured":"Jagan L, Turk W, Petropolis C, Egan R, Cofie N, Wright KW, et al. Validation of a novel strabismus surgery 3D-printed silicone eye model for simulation training. J Am Assoc Pediatr Ophthalmol Strabismus. 2020;24:e31\u20136.","journal-title":"J Am Assoc Pediatr Ophthalmol Strabismus"},{"key":"5034_CR6","doi-asserted-by":"publisher","first-page":"585","DOI":"10.1016\/j.jcjo.2019.02.012","volume":"54","author":"DJA Plemel","year":"2019","unstructured":"Plemel DJA, Nazarali SA, Damji KF, Chen SH. Tube shunt surgery in pig eyes: a wet lab teaching model. Can J Ophthalmol. 2019;54:585\u20139.","journal-title":"Can J Ophthalmol"},{"key":"5034_CR7","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1007\/s10544-018-0301-9","volume":"20","author":"A Ganguli","year":"2018","unstructured":"Ganguli A, Pagan-Diaz GJ, Grant L, Cvetkovic C, Bramlet M, Vozenilek J, et al. 3D printing for preoperative planning and surgical training: a review. Biomed Microdevices. 2018;20:65.","journal-title":"Biomed Microdevices"},{"key":"5034_CR8","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1046\/j.1442-9071.2002.00485.x","volume":"30","author":"YA Kerdraon","year":"2002","unstructured":"Kerdraon YA, Downie JA, Suaning GJ, Capon MR, Coroneo MT, Lovell NH. Development and surgical implantation of a vision prosthesis model into the ovine eye. Clin Exper Ophthalmol. 2002;30:36\u201340.","journal-title":"Clin Exper Ophthalmol"},{"key":"5034_CR9","doi-asserted-by":"publisher","first-page":"1251","DOI":"10.3390\/biology11091251","volume":"11","author":"A Banstola","year":"2022","unstructured":"Banstola A, Reynolds JNJ. The sheep as a large animal model for the investigation and treatment of human disorders. Biology. 2022;11:1251.","journal-title":"Biology"},{"key":"5034_CR10","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1016\/j.jsurg.2016.07.005","volume":"74","author":"JT Lichtenstein","year":"2017","unstructured":"Lichtenstein JT, Zeller AN, Lemound J, Lichtenstein TE, Rana M, Gellrich NC, et al. 3D-printed simulation device for orbital surgery. J Surg Educ. 2017;74:2\u20138.","journal-title":"J Surg Educ"},{"key":"5034_CR11","doi-asserted-by":"publisher","first-page":"1470","DOI":"10.1016\/j.gie.2015.03.1916","volume":"81","author":"BA Holt","year":"2015","unstructured":"Holt BA, Hearn G, Hawes R, Tharian B, Varadarajulu S. Development and evaluation of a 3D printed endoscopic ampullectomy training model (with video). Gastrointest Endosc. 2015;81:1470\u2013e14755.","journal-title":"Gastrointest Endosc"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-026-05034-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-05034-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-05034-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T08:55:16Z","timestamp":1782896116000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12886-026-05034-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,30]]},"references-count":11,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["5034"],"URL":"https:\/\/doi.org\/10.1186\/s12886-026-05034-x","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,30]]},"assertion":[{"value":"2 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethical approval was obtained from the King Khaled Eye Specialist Hospital and Research Center (IRB No. 20149-P) and written informed consent was obtained from all participants.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"369"}}