{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,16]],"date-time":"2026-11-16T21:57:59Z","timestamp":1794866279954,"version":"4.9.1"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T00:00:00Z","timestamp":1783382400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"vor","delay-in-days":86,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"DOI":"10.1186\/s12886-026-05048-5","type":"journal-article","created":{"date-parts":[[2026,7,7]],"date-time":"2026-07-07T16:12:48Z","timestamp":1783440768000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Accuracy of Kane, Hill-RBF, and PEARL-DGS versus traditional IOL formulas in highly myopic eyes: a systematic review and meta-analysis"],"prefix":"10.1186","volume":"26","author":[{"given":"Hong","family":"Chang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fei","family":"Qi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,7]]},"reference":[{"key":"5048_CR1","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1016\/j.ajo.2020.09.019","volume":"223","author":"H Cheng","year":"2021","unstructured":"Cheng H, Wang L, Kane JX, Li J, Liu L, Wu M. Accuracy of artificial intelligence formulas and axial length adjustments for highly myopic eyes. Am J Ophthalmol. 2021;223:100\u20137. https:\/\/doi.org\/10.1016\/j.ajo.2020.09.019.","journal-title":"Am J Ophthalmol"},{"issue":"10","key":"5048_CR2","doi-asserted-by":"publisher","first-page":"680","DOI":"10.3928\/1081597X-20210712-03","volume":"37","author":"Y Chen","year":"2021","unstructured":"Chen Y, Wei L, He W, Lu Y, Zhu X. Comparison of Kane, Hill-RBF 2.0, Barrett Universal II, and Emmetropia Verifying Optical formulas in eyes with extreme myopia. J Refract Surg. 2021;37(10):680\u20135. https:\/\/doi.org\/10.3928\/1081597X-20210712-03.","journal-title":"J Refract Surg"},{"key":"5048_CR3","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1186\/s40662-022-00293-3","volume":"9","author":"L Wei","year":"2022","unstructured":"Wei L, Cheng K, He W, Zhu X, Lu Y. Application of total keratometry in ten intraocular lens power calculation formulas in highly myopic eyes. Eye Vis (Lond). 2022;9:21. https:\/\/doi.org\/10.1186\/s40662-022-00293-3.","journal-title":"Eye Vis (Lond)"},{"key":"5048_CR4","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1007\/s10792-025-03608-0","volume":"45","author":"M Vilaltella","year":"2025","unstructured":"Vilaltella M, Cid-Bertomeu P, Seres-Noriega T, Huerva V. Accuracy of 12 IOL power calculation formulas in highly myopic eyes. Int Ophthalmol. 2025;45:264. https:\/\/doi.org\/10.1007\/s10792-025-03608-0.","journal-title":"Int Ophthalmol"},{"key":"5048_CR5","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1016\/j.ajo.2025.08.013","volume":"280","author":"M Kinoshita","year":"2025","unstructured":"Kinoshita M, Goto S, Mori Y, Torii H, Hasegawa Y, Kojima T, et al. Accuracy of new-generation intraocular lens power calculation formulas for highly myopic eyes: a multicenter study in Japan. Am J Ophthalmol. 2025;280:390\u20138. https:\/\/doi.org\/10.1016\/j.ajo.2025.08.013.","journal-title":"Am J Ophthalmol"},{"key":"5048_CR6","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1186\/s12886-025-04365-5","volume":"25","author":"X Jiang","year":"2025","unstructured":"Jiang X, Wang J, Jiang Q, Zhou X, Xia F, Gao M. Comparative evaluation of traditional and AI-based intraocular lens power calculation formulas in highly myopic eyes. BMC Ophthalmol. 2025;25:507. https:\/\/doi.org\/10.1186\/s12886-025-04365-5.","journal-title":"BMC Ophthalmol"},{"key":"5048_CR7","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1007\/s10792-026-04016-8","volume":"46","author":"GY Li","year":"2026","unstructured":"Li GY, Li ZY, Yang ZH, Zhao P, Li M, Xu J, et al. Accuracy of twelve intraocular lens calculation formulas in highly myopic eyes. Int Ophthalmol. 2026;46:144. https:\/\/doi.org\/10.1007\/s10792-026-04016-8.","journal-title":"Int Ophthalmol"},{"key":"5048_CR8","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1186\/s12886-026-04626-x","volume":"26","author":"GY Li","year":"2026","unstructured":"Li GY, Zhao P, Li ZY, Yang ZH, Li M, Xu J, et al. The influence of keratometry on the accuracy of intraocular lens formulas in highly myopic eyes. BMC Ophthalmol. 2026;26:89. https:\/\/doi.org\/10.1186\/s12886-026-04626-x.","journal-title":"BMC Ophthalmol"},{"issue":"3","key":"5048_CR9","doi-asserted-by":"publisher","first-page":"100198","DOI":"10.1016\/j.apjo.2025.100198","volume":"14","author":"W Stopyra","year":"2025","unstructured":"Stopyra W, Voytsekhivskyy O, Grzybowski A. Comparison of the accuracy of twenty intraocular lens power calculation formulas in long eyes. Asia Pac J Ophthalmol (Phila). 2025;14(3):100198. https:\/\/doi.org\/10.1016\/j.apjo.2025.100198.","journal-title":"Asia Pac J Ophthalmol (Phila)"},{"issue":"2","key":"5048_CR10","doi-asserted-by":"publisher","first-page":"100301","DOI":"10.1016\/j.apjo.2026.100301","volume":"15","author":"W Stopyra","year":"2026","unstructured":"Stopyra W, Voytsekhivskyy O, Grzybowski A. Accuracy of sixteen axial length adjusted intraocular lens power calculation formulas in long Caucasian eyes. Asia Pac J Ophthalmol (Phila). 2026;15(2):100301. https:\/\/doi.org\/10.1016\/j.apjo.2026.100301.","journal-title":"Asia Pac J Ophthalmol (Phila)"},{"key":"5048_CR11","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1016\/j.ajo.2024.04.017","volume":"265","author":"ER Mo","year":"2024","unstructured":"Mo ER, Chen Z, Feng KE, Zhu Z, Xu J, Zhu C, et al. Accuracy of modern intraocular lens formulas in highly myopic eyes implanted with plate-haptic intraocular lenses. Am J Ophthalmol. 2024;265:105\u201316. https:\/\/doi.org\/10.1016\/j.ajo.2024.04.017.","journal-title":"Am J Ophthalmol"},{"key":"5048_CR12","doi-asserted-by":"publisher","first-page":"1279718","DOI":"10.3389\/fpubh.2023.1279718","volume":"11","author":"Y Zhou","year":"2023","unstructured":"Zhou Y, Dai M, Sun L, Tang X, Zhou L, Tang Z, et al. The accuracy of intraocular lens power calculation formulas based on artificial intelligence in highly myopic eyes: a systematic review and network meta-analysis. Front Public Health. 2023;11:1279718. https:\/\/doi.org\/10.3389\/fpubh.2023.1279718.","journal-title":"Front Public Health"},{"issue":"8","key":"5048_CR13","doi-asserted-by":"publisher","first-page":"1066","DOI":"10.1136\/bjophthalmol-2021-320599","volume":"107","author":"T Li","year":"2023","unstructured":"Li T, Stein JD, Nallasamy N. Evaluation of the Nallasamy formula: a stacking ensemble machine learning method for refraction prediction in cataract surgery. Br J Ophthalmol. 2023;107(8):1066\u201371. https:\/\/doi.org\/10.1136\/bjophthalmol-2021-320599.","journal-title":"Br J Ophthalmol"},{"issue":"4","key":"5048_CR14","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1097\/j.jcrs.0000000000001126","volume":"49","author":"L Taroni","year":"2023","unstructured":"Taroni L, Hoffer KJ, Pellegrini M, Lupardi E, Savini G. Comparison of the new Hoffer QST with 4 modern accurate formulas. J Cataract Refract Surg. 2023;49(4):378\u201384. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001126.","journal-title":"J Cataract Refract Surg"},{"issue":"10","key":"5048_CR15","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1167\/tvst.13.10.40","volume":"13","author":"W Lou","year":"2024","unstructured":"Lou W, Zhou W, Wu M, Jin H. A new intraocular lens power formula integrating an artificial intelligence-powered estimation for effective lens position based on Chinese eyes. Transl Vis Sci Technol. 2024;13(10):40. https:\/\/doi.org\/10.1167\/tvst.13.10.40.","journal-title":"Transl Vis Sci Technol"},{"issue":"5","key":"5048_CR16","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1016\/j.ophtha.2018.12.046","volume":"126","author":"L Wang","year":"2019","unstructured":"Wang L, Cao D, Weikert MP, Koch DD. Calculation of axial length using a single group refractive index versus using different refractive indices for each ocular segment: theoretical study and refractive outcomes. Ophthalmology. 2019;126(5):663\u201370. https:\/\/doi.org\/10.1016\/j.ophtha.2018.12.046.","journal-title":"Ophthalmology"},{"key":"5048_CR17","doi-asserted-by":"publisher","first-page":"1511","DOI":"10.2147\/OPTH.S256851","volume":"14","author":"HJ Shammas","year":"2020","unstructured":"Shammas HJ, Shammas MC, Jivrajka RV, Cooke DL, Potvin R. Effects on IOL power calculation and expected clinical outcomes of axial length measurements based on multiple vs single refractive indices. Clin Ophthalmol. 2020;14:1511\u20139. https:\/\/doi.org\/10.2147\/OPTH.S256851.","journal-title":"Clin Ophthalmol"},{"key":"5048_CR18","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-031-50666-6_46","volume-title":"Intraocular Lens Calculations","author":"JX Kane","year":"2024","unstructured":"Kane JX. Kane formula. In: Aramberri J, Hoffer KJ, Olsen T, Savini G, Shammas HJ, editors. Intraocular Lens Calculations. Cham: Springer; 2024. https:\/\/doi.org\/10.1007\/978-3-031-50666-6_46."},{"key":"5048_CR19","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-031-50666-6_42","volume-title":"Intraocular Lens Calculations","author":"WE Hill","year":"2024","unstructured":"Hill WE. Hill-RBF: improving IOL power selection by artificial intelligence. In: Aramberri J, Hoffer KJ, Olsen T, Savini G, Shammas HJ, editors. Intraocular Lens Calculations. Cham: Springer; 2024. https:\/\/doi.org\/10.1007\/978-3-031-50666-6_42."},{"key":"5048_CR20","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.ajo.2021.05.004","volume":"232","author":"G Debellemani\u00e8re","year":"2021","unstructured":"Debellemani\u00e8re G, Dubois M, Gauvin M, Wallerstein A, Brenner LF, Rampat R, et al. The PEARL-DGS formula: the development of an open-source machine learning-based thick IOL calculation formula. Am J Ophthalmol. 2021;232:58\u201369. https:\/\/doi.org\/10.1016\/j.ajo.2021.05.004.","journal-title":"Am J Ophthalmol"},{"issue":"4","key":"5048_CR21","doi-asserted-by":"publisher","first-page":"200","DOI":"10.1016\/j.jcjo.2025.01.020","volume":"60","author":"W Stopyra","year":"2025","unstructured":"Stopyra W, Voytsekhivskyy O, Grzybowski A. Accuracy of 7 artificial intelligence-based intraocular lens power calculation formulas in medium-long eyes: 2-center study. Can J Ophthalmol. 2025;60(4):200\u20137. https:\/\/doi.org\/10.1016\/j.jcjo.2025.01.020.","journal-title":"Can J Ophthalmol"},{"issue":"1","key":"5048_CR22","doi-asserted-by":"publisher","first-page":"45","DOI":"10.3390\/life15010045","volume":"15","author":"W Stopyra","year":"2025","unstructured":"Stopyra W, Voytsekhivskyy O, Grzybowski A. Prediction of seven artificial intelligence-based intraocular lens power calculation formulas in medium-long Caucasian eyes. Life (Basel). 2025;15(1):45. https:\/\/doi.org\/10.3390\/life15010045.","journal-title":"Life (Basel)"},{"issue":"17","key":"5048_CR23","doi-asserted-by":"publisher","first-page":"e36609","DOI":"10.1016\/j.heliyon.2024.e36609","volume":"10","author":"F Cione","year":"2024","unstructured":"Cione F, De Bernardo M, Di Paola I, Caputo A, Graziano M, Rosa N. IOL power calculation in long eyes: selection of the best axial length adjustement factor using the most common formulas. Heliyon. 2024;10(17):e36609. https:\/\/doi.org\/10.1016\/j.heliyon.2024.e36609.","journal-title":"Heliyon"},{"issue":"12","key":"5048_CR24","doi-asserted-by":"publisher","first-page":"1063","DOI":"10.1097\/j.jcrs.0000000000001739","volume":"51","author":"AML De Vitto","year":"2025","unstructured":"De Vitto AML, Pasculli F, Cione F, Santorum P, Rosa N, De Bernardo M, Emesz M, Bertelli E. Intraocular lens power calculation adapted to sutureless scleral fixation with the Yamane technique. J Cataract Refract Surg. 2025;51(12):1063\u201370. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001739.","journal-title":"J Cataract Refract Surg"},{"key":"5048_CR25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.ajo.2026.02.017","volume":"286","author":"W Stopyra","year":"2026","unstructured":"Stopyra W, Voytsekhivskyy O, Grzybowski A, Wang L, Koch DD. Prediction of 9 artificial intelligence-based intraocular lens power calculation formulas in long Caucasian eyes. Am J Ophthalmol. 2026;286:1\u201311. https:\/\/doi.org\/10.1016\/j.ajo.2026.02.017.","journal-title":"Am J Ophthalmol"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-026-05048-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-05048-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-05048-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:27:17Z","timestamp":1790814437000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12886-026-05048-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,7]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["5048"],"URL":"https:\/\/doi.org\/10.1186\/s12886-026-05048-5","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,7]]},"assertion":[{"value":"22 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Ethics approval and informed consent were not required because this study was a systematic review and meta-analysis of previously published studies.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"612"}}