{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,10]],"date-time":"2026-08-10T10:29:47Z","timestamp":1786357787906,"version":"build-2736575974"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,8,8]],"date-time":"2026-08-08T00:00:00Z","timestamp":1786147200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,8,10]],"date-time":"2026-08-10T00:00:00Z","timestamp":1786320000000},"content-version":"vor","delay-in-days":2,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100007653","name":"Universit\u00e4tsklinikum Jena","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100007653","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Ophthalmol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Retinal vessel oximetry requires fundus images at two wavelengths with different hemoglobin absorption characteristics. Simultaneous acquisition using one-chip color cameras may be affected by incomplete spectral separation of detector channels, whereas multi-chip systems such as 3-chip CCD cameras can achieve improved spectral separation. We present a serial dual-wavelength illumination approach integrated into a conventional fundus camera and compare oxygen saturation measurements with those obtained from a commercial retinal oximeter.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A custom LED illumination unit was fiber-coupled into a fundus camera to provide serial illumination at 548\u00a0nm (isosbestic hemoglobin wavelength) and 605\u00a0nm (oxygen-sensitive wavelength with differential absorption between oxy- and deoxyhemoglobin), each for 250 ms. Corneal irradiance was 33 mW\/cm\u00b2 at 548\u00a0nm and 7 mW\/cm\u00b2 at 605\u00a0nm. Sequentially acquired images were registered and analyzed using established retinal oximetry algorithms. Mean arterial and venous oxygen saturation values were compared with measurements from a commercial retinal oximeter in nine participants undergoing routine ophthalmic examination. Linear regression analysis was performed to assess the association between methods, and agreement was additionally evaluated using Bland\u2013Altman analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Mean arterial oxygen saturation was 99.4\u2009\u00b1\u20095.7% with serial illumination and 100.4\u2009\u00b1\u20093.0% with standard oximetry. Mean venous oxygen saturation was 71.5\u2009\u00b1\u20097.0% and 69.5\u2009\u00b1\u200911.6%, respectively. The mean absolute differences between both techniques were 3.6\u2009\u00b1\u20092.7% for arteries and 8.4\u2009\u00b1\u20099.3% for veins. Bland\u2013Altman analysis showed a small arterial bias of 0.94% with limits of agreement from \u2212\u20097.9% to +\u20099.8%. For venous measurements, bias was \u2212\u20091.98% with wider limits of agreement (\u2212\u200926.9% to +\u200922.9%). Arterial measurements showed borderline non-significant correlation (\n                      <jats:italic>R<\/jats:italic>\n                      \u2009=\u20090.606,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.084). Venous measurements showed no correlation.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Serial illumination is feasible for retinal vessel oximetry and mitigates detector-level spectral crosstalk associated with simultaneous dual-wavelength imaging using one-chip color cameras. Arterial measurements showed only a small systematic bias compared with the commercial retinal oximeter, whereas venous measurements demonstrated greater variability, indicating the need for further optimization and validation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12886-026-05216-7","type":"journal-article","created":{"date-parts":[[2026,8,8]],"date-time":"2026-08-08T02:05:35Z","timestamp":1786154735000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Serial dual-wavelength illumination for retinal vessel oximetry using a conventional fundus camera: a proof-of-concept study"],"prefix":"10.1186","volume":"26","author":[{"ORCID":"https:\/\/orcid.org\/0009-0004-7996-7800","authenticated-orcid":false,"given":"Melih","family":"Tarhan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Meller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Hammer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,8]]},"reference":[{"issue":"2","key":"5216_CR1","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/S1350-9462(00)00027-6","volume":"20","author":"DY Yu","year":"2001","unstructured":"Yu DY, Cringle SJ. Oxygen distribution and consumption within the retina in vascularised and avascular retinas and in animal models of retinal disease. Prog Retin Eye Res. 2001;20(2):175\u2013208.","journal-title":"Prog Retin Eye Res"},{"issue":"2","key":"5216_CR2","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1007\/BF00935719","volume":"228","author":"E Stefansson","year":"1990","unstructured":"Stefansson E. Oxygen and diabetic eye disease. Graefes Arch Clin Exp Ophthalmol. 1990;228(2):120\u20133.","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"issue":"3","key":"5216_CR3","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1016\/j.preteyeres.2008.02.002","volume":"27","author":"CJ Pournaras","year":"2008","unstructured":"Pournaras CJ, Rungger-Br\u00e4ndle E, Riva CE, Hardarson SH, Stefansson E. Regulation of retinal blood flow in health and disease. Prog Retin Eye Res. 2008;27(3):284\u2013330.","journal-title":"Prog Retin Eye Res"},{"issue":"4","key":"5216_CR4","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1136\/bjophthalmol-2011-300640","volume":"96","author":"SH Hardarson","year":"2012","unstructured":"Hardarson SH, Stef\u00e1nsson E. Retinal oxygen saturation is altered in diabetic retinopathy. Br J Ophthalmol. 2012;96(4):560\u20133.","journal-title":"Br J Ophthalmol"},{"issue":"11","key":"5216_CR5","doi-asserted-by":"publisher","first-page":"5011","DOI":"10.1167\/iovs.06-0039","volume":"47","author":"SH Hardarson","year":"2006","unstructured":"Hardarson SH, Harris A, Karlsson RA, Halldorsson GH, Kagemann L, Rechtman E, Zoega GMr, Eysteinsson T, Benediktsson JA, Thorsteinsson A, et al. Automatic Retinal Oximetry. Investig Ophthalmol Vis Sci. 2006;47(11):5011\u20136.","journal-title":"Investig Ophthalmol Vis Sci"},{"issue":"1","key":"5216_CR6","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1111\/aos.12294","volume":"92","author":"A Geirsdottir","year":"2014","unstructured":"Geirsdottir A, Hardarson SH, Olafsdottir OB, Stef\u00e1nsson E. Retinal oxygen metabolism in exudative age-related macular degeneration. Acta Ophthalmol. 2014;92(1):27\u201333.","journal-title":"Acta Ophthalmol"},{"issue":"6","key":"5216_CR7","doi-asserted-by":"publisher","first-page":"1113","DOI":"10.1364\/AO.27.001113","volume":"27","author":"FC Delori","year":"1988","unstructured":"Delori FC. Noninvasive technique for oximetry of blood in retinal vessels. Appl Opt. 1988;27(6):1113\u201325.","journal-title":"Appl Opt"},{"issue":"7","key":"5216_CR8","doi-asserted-by":"publisher","first-page":"1183","DOI":"10.1364\/AO.39.001183","volume":"39","author":"MH Smith","year":"2000","unstructured":"Smith MH, Denninghoff KR, Lompado A, Hillman LW. Effect of multiple light paths on retinal vessel oximetry. Appl Opt. 2000;39(7):1183\u201393.","journal-title":"Appl Opt"},{"issue":"12","key":"5216_CR9","doi-asserted-by":"publisher","first-page":"1454","DOI":"10.1109\/10.804573","volume":"46","author":"D Schweitzer","year":"1999","unstructured":"Schweitzer D, Hammer M, Kraft J, Thamm E, K\u00f6nigsd\u00f6rffer E, Strobel J. In vivo measurement of the oxygen saturation of retinal vessels in healthy volunteers. IEEE Trans Biomed Eng. 1999;46(12):1454\u201365.","journal-title":"IEEE Trans Biomed Eng"},{"issue":"5","key":"5216_CR10","doi-asserted-by":"publisher","first-page":"054015","DOI":"10.1117\/1.2976032","volume":"13","author":"M Hammer","year":"2008","unstructured":"Hammer M, Vilser W, Riemer T, Schweitzer D. Retinal vessel oximetry-calibration, compensation for vessel diameter and fundus pigmentation, and reproducibility. J Biomed Opt. 2008;13(5):054015.","journal-title":"J Biomed Opt"},{"issue":"2","key":"5216_CR11","doi-asserted-by":"publisher","first-page":"748","DOI":"10.1152\/jappl.1999.86.2.748","volume":"86","author":"JM Beach","year":"1999","unstructured":"Beach JM, Schwenzer KJ, Srinivas S, Kim D, Tiedeman JS. Oximetry of retinal vessels by dual-wavelength imaging: calibration and influence of pigmentation. J Appl Physiol (1985). 1999;86(2):748\u201358.","journal-title":"J Appl Physiol (1985)"},{"issue":"1","key":"5216_CR12","doi-asserted-by":"publisher","first-page":"014036","DOI":"10.1117\/1.2434950","volume":"12","author":"WR Johnson","year":"2007","unstructured":"Johnson WR, Wilson DW, Fink W, Humayun M, Bearman G. Snapshot hyperspectral imaging in ophthalmology. J Biomed Opt. 2007;12(1):014036.","journal-title":"J Biomed Opt"},{"issue":"11","key":"5216_CR13","doi-asserted-by":"publisher","first-page":"6633","DOI":"10.1167\/iovs.15-17321","volume":"56","author":"AE Felder","year":"2015","unstructured":"Felder AE, Wanek J, Blair NP, Shahidi M. Inner Retinal Oxygen Extraction Fraction in Response to Light Flicker Stimulation in Humans. Invest Ophthalmol Vis Sci. 2015;56(11):6633\u20137.","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"4","key":"5216_CR14","doi-asserted-by":"publisher","first-page":"041212","DOI":"10.1117\/1.2772655","volume":"12","author":"L Kagemann","year":"2007","unstructured":"Kagemann L, Wollstein G, Wojtkowski M, Ishikawa H, Townsend KA, Gabriele ML, Srinivasan VJ, Fujimoto JG, Schuman JS. Spectral oximetry assessed with high-speed ultra-high-resolution optical coherence tomography. J Biomed Opt. 2007;12(4):041212.","journal-title":"J Biomed Opt"},{"key":"5216_CR15","doi-asserted-by":"publisher","first-page":"1577","DOI":"10.1109\/TMI.2011.2140329","volume":"30","author":"S Kim","year":"2011","unstructured":"Kim S, Kim D, Suh M, Kim M, Kim HC. Retinal Oximetry Based on Nonsimultaneous Image Acquisition Using a Conventional Fundus Camera. IEEE Trans Med Imaging. 2011;30:1577\u201380.","journal-title":"IEEE Trans Med Imaging"},{"issue":"1","key":"5216_CR16","doi-asserted-by":"publisher","first-page":"4270","DOI":"10.1038\/s41598-017-04085-x","volume":"7","author":"S Singh","year":"2017","unstructured":"Singh S, Velu G, Raman R. Development and Validation of Non simultaneous Retinal Image Acquisition\u2013Based Retinal Oximeter. Sci Rep. 2017;7(1):4270.","journal-title":"Sci Rep"},{"issue":"7","key":"5216_CR17","doi-asserted-by":"publisher","first-page":"717","DOI":"10.1111\/j.1755-3768.2009.01587.x","volume":"88","author":"G Garhofer","year":"2010","unstructured":"Garhofer G, Bek T, Boehm AG, Gherghel D, Grunwald J, Jeppesen P, Kergoat H, Kotliar K, Lanzl I, Lovasik JV, et al. Use of the retinal vessel analyzer in ocular blood flow research. Acta Ophthalmol. 2010;88(7):717\u201322.","journal-title":"Acta Ophthalmol"},{"issue":"8476","key":"5216_CR18","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","volume":"1","author":"JM Bland","year":"1986","unstructured":"Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet (London England). 1986;1(8476):307\u201310.","journal-title":"Lancet (London England)"}],"container-title":["BMC Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12886-026-05216-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-05216-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12886-026-05216-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,10]],"date-time":"2026-08-10T09:42:16Z","timestamp":1786354936000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12886-026-05216-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,8]]},"references-count":18,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["5216"],"URL":"https:\/\/doi.org\/10.1186\/s12886-026-05216-7","relation":{},"ISSN":["1471-2415"],"issn-type":[{"value":"1471-2415","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,8]]},"assertion":[{"value":"23 April 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 August 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 August 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study adhered to the tenets of the Declaration of Helsinki and was approved by the Ethics Committee of the University Hospital Jena (Friedrich Schiller University Jena, Germany; reference number: 2019-1555-BO). Written informed consent was obtained from all participants prior to examination.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"477"}}