{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T10:55:49Z","timestamp":1740135349897,"version":"3.37.3"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,1,22]],"date-time":"2020-01-22T00:00:00Z","timestamp":1579651200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2020,1,22]],"date-time":"2020-01-22T00:00:00Z","timestamp":1579651200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000071","name":"National Institute of Child Health and Human Development","doi-asserted-by":"crossref","award":["HHSN2752010000031"],"award-info":[{"award-number":["HHSN2752010000031"]}],"id":[{"id":"10.13039\/100000071","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Pediatr"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Background<\/jats:title>\n<jats:p>Weight is critical for the medical management of infants; however, scales can be unavailable or inaccessible in some practice settings. We recently developed and validated a robust infant weight estimation method based on chest circumference (CC) and head circumference (HC). This study was designed to determine the human factors (HF) experience with, and predictive performance of, an infant weight estimation device that implements this method.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>Prospective, multi-center, observational, masked study of 486 preterm and term infants (0\u201390\u2009days) assessed by 15 raters. Raters measured the infant using calibrated scales\/measures and masked versions of the device. Raters also evaluated critical tasks associated with device use. Mean error (ME) and mean percentage error (MPE) were used to assess predictive performance.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Result<\/jats:title>\n<jats:p>Among 486 infants enrolled (36.8\u2009\u00b1\u20094.0\u2009weeks gestational age, 31.5\u2009\u00b1\u200928.6\u2009days postnatal age), predicted weight correlated highly with actual weight (r\u2009=\u20090.97, ME: \u2212\u200969\u2009\u00b1\u2009257\u2009g, MPE: \u2212\u20091.3\u2009\u00b1\u20096.9%). Predicted weight was within 10 and 15% of actual weight in 86 and 99%, of infants. HF errors were low, 0.1\u20130.8% depending on task. In all cases raters were confident or very confident in their measurements.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusion<\/jats:title>\n<jats:p>The device was statistically equivalent to the method on which it was based and approximated weight with acceptable variance from the true weight. HF data suggest the device is easy to use. This device can be used to estimate weight in infants when calibrated scales are impractical or unavailable.<\/jats:p>\n<\/jats:sec>","DOI":"10.1186\/s12887-020-1933-5","type":"journal-article","created":{"date-parts":[[2020,1,22]],"date-time":"2020-01-22T17:03:08Z","timestamp":1579712588000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Validation and human factor analysis study of an infant weight estimation device"],"prefix":"10.1186","volume":"20","author":[{"name":"on behalf of the Best Pharmaceuticals for Children Act \u2013 Pediatric Trials Network","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5815-2029","authenticated-orcid":false,"given":"Susan M.","family":"Abdel-Rahman","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ian M.","family":"Paul","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paula","family":"Delmore","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jia-Yuh","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mary","family":"Mills","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rachel G.","family":"Greenberg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,1,22]]},"reference":[{"key":"1933_CR1","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1016\/S0140-6736(07)61690-0","volume":"371","author":"RE Black","year":"2008","unstructured":"Black RE, Allen LH, Bhutta ZA, Caulfield LE, de Onis M, Ezzati M, et al. Maternal and child undernutrition: global and regional exposures and health consequences. Lancet. 2008;371:243\u201360.","journal-title":"Lancet"},{"key":"1933_CR2","doi-asserted-by":"publisher","first-page":"2151","DOI":"10.1016\/S0140-6736(12)60560-1","volume":"379","author":"L Liu","year":"2012","unstructured":"Liu L, Johnson HL, Cousens S, Perin J, Scott S, Lawn JE, et al. Global, regional, and national causes of child mortality: an updated systematic analysis for 2010 with time trends since 2000. Lancet. 2012;379:2151\u201361.","journal-title":"Lancet"},{"key":"1933_CR3","volume-title":"World health statistics 2013: a wealth of information on global public health","author":"WHO","year":"2013","unstructured":"WHO. World health statistics 2013: a wealth of information on global public health. Geneva: WHO; 2013. https:\/\/apps.who.int\/iris\/handle\/10665\/82058. Accessed 25 Nov 2019."},{"key":"1933_CR4","unstructured":"Caring for the Newborn at Home: A training course for community health workers: Facilitator Guide. WHO Press, World Health Organization, Geneva. 2012. https:\/\/www.who.int\/maternal_child_adolescent\/news\/events\/2012\/Facilitator_Guide_Unit1.pdf. Accessed 25 Nov 2019."},{"key":"1933_CR5","unstructured":"Ghana Statistical Service, Health Research Unit, Ministry of Health, Accra, Ghana and ORC Macro, Calverton. Ghana MCH SPA Final Report 2002. https:\/\/dhsprogram.com\/pubs\/pdf\/SPA6\/SPA6.pdf. Accessed 25 Nov 2019."},{"key":"1933_CR6","volume-title":"Kenya service provision assessment survey 2010","author":"National Coordinating Agency for Population and Development (NCAPD) [Kenya], Ministry of Medical Services (MOMS) [Kenya], Ministry of Public Health and Sanitation (MOPHS) [Kenya], Kenya National Bureau of Statistics (KNBS) [Kenya], ICF Macro","year":"2011","unstructured":"National Coordinating Agency for Population and Development (NCAPD) [Kenya], Ministry of Medical Services (MOMS) [Kenya], Ministry of Public Health and Sanitation (MOPHS) [Kenya], Kenya National Bureau of Statistics (KNBS) [Kenya], ICF Macro. Kenya service provision assessment survey 2010. Nairobi: National Coordinating Agency for Population and Development, Ministry of Medical Services, Ministry of Public Health and Sanitation, Kenya National Bureau of Statistics, and ICF Macro; 2011. https:\/\/dhsprogram.com\/pubs\/pdf\/SPA17\/SPA17.pdf. Accessed 25 Nov 2019"},{"key":"1933_CR7","volume-title":"Rwanda service provision assessment survey 2007","author":"National Institute of Statistics (NIS) [Rwanda], Ministry of Health (MOH) [Rwanda], and Macro International Inc","year":"2008","unstructured":"National Institute of Statistics (NIS) [Rwanda], Ministry of Health (MOH) [Rwanda], and Macro International Inc. Rwanda service provision assessment survey 2007. Calverton: NIS, MOH, and Macro International Inc.; 2008. https:\/\/dhsprogram.com\/pubs\/pdf\/SPA15\/SPA15.pdf. Accessed 25 Nov 2019"},{"key":"1933_CR8","volume-title":"Uganda service provision assessment survey 2007","author":"Ministry of Health (MOH) [Uganda] and Macro International Inc","year":"2008","unstructured":"Ministry of Health (MOH) [Uganda] and Macro International Inc. Uganda service provision assessment survey 2007. Kampala: Ministry of Health and Macro International Inc.; 2008. https:\/\/www.dhsprogram.com\/pubs\/pdf\/SPA13\/SPA13.pdf. Accessed 25 Nov 2019"},{"key":"1933_CR9","doi-asserted-by":"publisher","first-page":"354","DOI":"10.2188\/jea.JE20100182","volume":"21","author":"E Goto","year":"2001","unstructured":"Goto E. Meta-analysis: identification of low birthweight by other anthropometric measurements at birth in developing countries. J Epidemiol. 2001;21:354\u201362.","journal-title":"J Epidemiol"},{"key":"1933_CR10","first-page":"1","volume":"4","author":"SM Abdel-Rahman","year":"2017","unstructured":"Abdel-Rahman SM, Paul I, Delmore P, James L, Yogev R, Atz A, et al. A weight estimation strategy for preterm and full-term infants. Glob Pediatr Health. 2017;4:1\u20139.","journal-title":"Glob Pediatr Health"},{"key":"1933_CR11","doi-asserted-by":"publisher","first-page":"87","DOI":"10.2174\/1875181401204010087","volume":"4","author":"SM Abdel-Rahman","year":"2012","unstructured":"Abdel-Rahman SM, Ridge AL. An improved pediatric weight estimation strategy. Open Med Dev J. 2012;4:87\u201397.","journal-title":"Open Med Dev J"},{"key":"1933_CR12","volume-title":"Applying Human Factors and Usability Engineering to Medical Devices: Guidance for Industry and Food and Drug Administration Staff","author":"U.S. Department of Health and Human Services, Food and Drug Administration","year":"2016","unstructured":"U.S. Department of Health and Human Services, Food and Drug Administration. Applying Human Factors and Usability Engineering to Medical Devices: Guidance for Industry and Food and Drug Administration Staff. 2016."},{"key":"1933_CR13","doi-asserted-by":"publisher","first-page":"678","DOI":"10.1080\/03014460.2017.1392603","volume":"44","author":"SM Abdel-Rahman","year":"2017","unstructured":"Abdel-Rahman SM, Paul IM, Delmore P, James L, Fearn L, Atz AM, et al. An anthropometric survey of US pre-term and full-term neonates. Ann Hum Biol. 2017;44:678\u201386.","journal-title":"Ann Hum Biol"},{"key":"1933_CR14","unstructured":"Centers for Disease Control and Prevention. National Health and Nutrition Examination Survey: questionnaires, datasets, and related documentation. https:\/\/wwwn.cdc.gov\/nchs\/nhanes\/Default.aspx. Accessed 25 Nov 2019."},{"key":"1933_CR15","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1093\/tropej\/fmr004","volume":"57","author":"M Ghosh","year":"2011","unstructured":"Ghosh M, Das S, Chakraborty S, Chatterjee R. Designing colour-coded measuring tapes based on mid-arm and chest circumference to predict low birth weight in the field. J Trop Pediatr. 2011;57:464\u20137.","journal-title":"J Trop Pediatr"},{"key":"1933_CR16","first-page":"143","volume":"27","author":"TO Lawoyin","year":"1998","unstructured":"Lawoyin TO. Validation and use of a simple device to identify low birth weight babies at birth. Afr J Med Med Sci. 1998;27:143\u20135.","journal-title":"Afr J Med Med Sci"},{"key":"1933_CR17","first-page":"36","volume":"5","author":"RK Sachar","year":"1994","unstructured":"Sachar RK, Soni RK, Afzal T, Singh H, Sofat R. Efficacy of colour coded strips for classifying birth weights. Indian J Matern Child Health. 1994;5:36\u20138.","journal-title":"Indian J Matern Child Health"},{"key":"1933_CR18","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1186\/1471-2458-14-859","volume":"14","author":"T Marchant","year":"2014","unstructured":"Marchant T, Penfold S, Mkumbo E, Shamba D, Jaribu J, Manzi F, et al. The reliabilityof a newborn foot length measurement tool used by community volunteers to identify low birth weight or premature babies born at home in southern Tanzania. BMC Public Health. 2014;14:859.","journal-title":"BMC Public Health"},{"key":"1933_CR19","doi-asserted-by":"publisher","first-page":"332","DOI":"10.1016\/j.annemergmed.2013.02.021","volume":"62","author":"SM Abdel-Rahman","year":"2013","unstructured":"Abdel-Rahman SM, Paul IM, James LP, Lewandowski A, on behalf of the Pediatric Trials Network. Evaluation of the mercy TAPE: performance against the standard for pediatric weight estimation. Ann Emerg Med. 2013;62:332\u20139.","journal-title":"Ann Emerg Med"},{"key":"1933_CR20","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1097\/PEC.0000000000000543","volume":"33","author":"SM Abdel-Rahman","year":"2017","unstructured":"Abdel-Rahman SM, Jacobsen R, Watts JL, Doyle SL, O\u2019Malley DM, Hefner TD, et al. Comparative performance of pediatric weight estimation techniques: a human factor errors analysis. Pediatr Emerg Care. 2017;33:548\u201352.","journal-title":"Pediatr Emerg Care"},{"key":"1933_CR21","first-page":"112","volume":"18","author":"SM Abdel-Rahman","year":"2013","unstructured":"Abdel-Rahman SM, Ahlers N, Holmes A, Wright K, Harris A, Weigel J, et al. Validation of an improved pediatric weight estimation strategy. J Pediatr Pharmacol Ther. 2013;18:112\u201321.","journal-title":"J Pediatr Pharmacol Ther"}],"container-title":["BMC Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12887-020-1933-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12887-020-1933-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12887-020-1933-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,21]],"date-time":"2021-01-21T00:14:16Z","timestamp":1611188056000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcpediatr.biomedcentral.com\/articles\/10.1186\/s12887-020-1933-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,1,22]]},"references-count":21,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["1933"],"URL":"https:\/\/doi.org\/10.1186\/s12887-020-1933-5","relation":{},"ISSN":["1471-2431"],"issn-type":[{"type":"electronic","value":"1471-2431"}],"subject":[],"published":{"date-parts":[[2020,1,22]]},"assertion":[{"value":"22 April 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 January 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 January 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"All infants were enrolled following receipt of verbal parental informed consent under a protocol that was reviewed and approved by the Institutional Review Boards at Children\u2019s Mercy (IRB# 16110806), Penn State Children\u2019s Hospital (IRB# 00006333), and Wesley Medical Center (IRB# 00002143). A waiver of documentation of permission was authorized by the IRBs because 1) the study presented minimal risk to the participant, 2) investigators collected no protected health information, and 3) a signed permission form would be the only record linking the participant and the study introducing an unnecessary risk from breach of confidentiality.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Children\u2019s Mercy (CM) has been issued a patent for a related weight estimation device for children that <b>does not<\/b> extend to the device described in this manuscript. CM will file a 510(k) seeking marketing clearance from the U.S. Food and Drug Administration for the Mercy babyTAPE; however, CM does not have, never has had, and will not develop an interest in extracting royalties for use of these devices in developing countries or in situations in which royalties could hinder adoption of this device.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"30"}}