{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T07:20:42Z","timestamp":1789716042123,"version":"4.0.1"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,1,31]],"date-time":"2022-01-31T00:00:00Z","timestamp":1643587200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,1,31]],"date-time":"2022-01-31T00:00:00Z","timestamp":1643587200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Pediatr"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Medical management of neonates is often established upon safe and reliable vascular access, frequently utilized to provide physiological monitoring, parenteral and supportive treatments, and diagnostic and\/or procedural purposes. For this, peripherally inserted central catheters (PICCs) are often used to provide safe vascular access and infusion-related therapies in the neonatal intensive care (NICU) setting.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:p>Difficult PICC guidewire removal is understood to cause catheter damage, causing luminal rupture or possible breakage of the catheter or guidewire itself. The aim of this study was to assess and compare the incidence of therapy failures with use of a preflush fluid using normal saline (NSS) versus a diluted lipid solution (DLS) prior to device insertion, to assist with guidewire removal and prevent unnecessary catheter damage.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Method and setting<\/jats:title>\n                    <jats:p>A retrospective, observational study was performed in the Neonatal Intensive Care Unit (NICU) of the Women\u2019s Wellness and Research Centre, Hamad Medical Corporation, Qatar. This single site study included 507 neonates who required intravenous therapy administered via a PICC during the study period.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Results demonstrated the use of a diluted lipid solution preflush (DLS) resulted in significantly lesser failures, when compared with the control group (NSS). This highlights a clinical significance after adjusting for day of insertion, gestational age, birth weight and catheter type.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>DLS preflush demonstrated a benefit over the use of a NSS preflush to enhance PICC guidewire removal in neonatal patients in the NICU. The risk for development of maintenance-related complications leading to premature device removal decreased significantly if the DLS preflush was used. During the study period, no complications related to the use of a lipid preflush solution were identified.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Implications for practice and research<\/jats:title>\n                    <jats:p>This may be the first study published investigating and supporting guidewire removal enhancement by using a diluted lipid\/saline preflush solution. When the requirement for vascular access is most pertinent in the neonate, using a diluted lipid preflush may provide an effective method to assist in guidewire removal to prevent malposition and vascular device complications in the neonatal population.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12887-022-03119-2","type":"journal-article","created":{"date-parts":[[2022,1,30]],"date-time":"2022-01-30T23:18:58Z","timestamp":1643584738000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Evaluation of a diluted lipid emulsion solution as a lubricant for improved peripherally inserted central catheter guidewire removal in a neonatal population"],"prefix":"10.1186","volume":"22","author":[{"given":"Matheus F. P. T.","family":"van Rens","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ratheesh","family":"Paramban","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Airene L. V.","family":"Francia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Prem","family":"Chandra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamad Adnan","family":"Mahmah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ulrich H.","family":"Thome","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad A. A.","family":"Bayoumi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timothy R.","family":"Spencer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,1,31]]},"reference":[{"issue":"23","key":"3119_CR1","doi-asserted-by":"publisher","first-page":"2612","DOI":"10.1001\/jama.2016.7020","volume":"315","author":"SB Ainsworth","year":"2016","unstructured":"Ainsworth SB, McGuire W. Peripherally inserted central catheters vs peripheral cannulas for delivering parenteral nutrition in neonates. JAMA. 2016;315(23):2612\u20133. https:\/\/doi.org\/10.1001\/jama.2016.7020.","journal-title":"JAMA"},{"key":"3119_CR2","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4471-4721-3_9","volume-title":"Rickham's neonatal surgery","author":"CT Baillie","year":"2018","unstructured":"Baillie CT. Neonatal Vascular Access. In: Losty P, Flake A, Rintala R, Hutson J, lwai N., editors. Rickham's neonatal surgery. London: Springer; 2018. https:\/\/doi.org\/10.1007\/978-1-4471-4721-3_9."},{"key":"3119_CR3","doi-asserted-by":"publisher","unstructured":"Ullman AJ, Bernstein SJ, Brown E, Aiyagari R, Doellman D, Faustino E, Gore B, Jacobs JP, Jaffray J, Kleidon T, Mahajan PV, McBride CA, Morton K, Pitts S, Prentice E, Rivard DC, Shaughnessy E, Stranz M, Wolf J, Cooper DS, Chopra V. The Michigan appropriateness guide for intravenous catheters in pediatrics: miniMAGIC. Pediatrics. 2020;145(Suppl 3):S269\u201384. https:\/\/doi.org\/10.1542\/peds.2019-3474I","DOI":"10.1542\/peds.2019-3474I"},{"issue":"6","key":"3119_CR4","doi-asserted-by":"publisher","first-page":"304","DOI":"10.1053\/adnc.2002.36826","volume":"2","author":"J Pettit","year":"2002","unstructured":"Pettit J. Assessment of infants with peripherally inserted central catheters: part 1. Detecting the most frequently occurring complications. Adv Neonatal Care. 2002;2(6):304\u201315. https:\/\/doi.org\/10.1053\/adnc.2002.36826.","journal-title":"Adv Neonatal Care."},{"issue":"5","key":"3119_CR5","first-page":"230","volume":"3","author":"J Pettit","year":"2003","unstructured":"Pettit J. Assessment of the infant with a peripheral intravenous device. Adv Neonatal Care. 2003;3(5):230\u201340.","journal-title":"Adv Neonatal Care"},{"issue":"4","key":"3119_CR6","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1016\/j.java.2018.07.002","volume":"23","author":"N Moureau","year":"2018","unstructured":"Moureau N. Impact and safety associated with accidental dislodgement of vascular access devices: a survey of professions, settings, and devices. J Assoc Vasc Access. 2018;23(4):203\u201315, ISSN 1552-8855. https:\/\/doi.org\/10.1016\/j.java.2018.07.002.","journal-title":"J Assoc Vasc Access"},{"key":"3119_CR7","doi-asserted-by":"publisher","first-page":"3769376","DOI":"10.1155\/2018\/3769376","volume":"2018","author":"X Yu","year":"2018","unstructured":"Yu X, Yue S, Wang M, Cao C, Liao Z, Ding Y, et al. Risk factors related to peripherally inserted central venous catheter nonselective removal in neonates. Biomed Res Int. 2018;2018:3769376. https:\/\/doi.org\/10.1155\/2018\/3769376.","journal-title":"Biomed Res Int"},{"issue":"19","key":"3119_CR8","doi-asserted-by":"publisher","first-page":"S12","DOI":"10.12968\/bjon.2020.29.19.S12","volume":"29","author":"K Hugill","year":"2020","unstructured":"Hugill K, van Rens M. Inserting central lines via the peripheral circulation in neonates. Br J Nurs. 2020;29(19):S12\u20138. https:\/\/doi.org\/10.12968\/bjon.2020.29.19.S12.","journal-title":"Br J Nurs"},{"issue":"10","key":"3119_CR9","doi-asserted-by":"publisher","first-page":"e027278","DOI":"10.1136\/bmjopen-2018-027278","volume":"9","author":"D Wang","year":"2019","unstructured":"Wang D, Niu F, Gao H, Yu M, Li Y, Xu L, et al. Influence of guide wire removal on tip location in peripherally inserted central catheters (PICCs): a retrospective cross-sectional study. BMJ Open. 2019;9(10):e027278. https:\/\/doi.org\/10.1136\/bmjopen-2018-027278.","journal-title":"BMJ Open"},{"key":"3119_CR10","unstructured":"Thome UH. personal email communication. (2019, May 23)"},{"issue":"4","key":"3119_CR11","doi-asserted-by":"publisher","first-page":"388","DOI":"10.3390\/nu9040388","volume":"9","author":"M Raman","year":"2017","unstructured":"Raman M, Almutairdi A, Mulesa L, Alberda C, Beattie C, Gramlich L. Parenteral nutrition and lipids. Nutrients. 2017;9(4):388. https:\/\/doi.org\/10.3390\/nu9040388.","journal-title":"Nutrients"},{"key":"3119_CR12","unstructured":"Fresenius Kabi (2017, May 11). INTRALIPID\u00ae Lipid Injectable Emulsion. https:\/\/www.fresenius-kabi.com\/en-ca\/documents\/Intralipid-PM-ENG.pdf"},{"issue":"3","key":"3119_CR13","doi-asserted-by":"publisher","first-page":"31","DOI":"10.2309\/j.java.2019.003.004","volume":"24","author":"L Steere","year":"2019","unstructured":"Steere L, Ficara C, Davis M, Moureau N. (2019). Reaching one peripheral intravenous catheter (PIVC) per patient visit with lean multimodal strategy: the PIV5Rights TM bundle. J Assoc Vasc Access. 2019;24(3):31\u201343. https:\/\/doi.org\/10.2309\/j.java.2019.003.004.","journal-title":"J Assoc Vasc Access"},{"key":"3119_CR14","unstructured":"Wyckoff M, Sharpe E. Peripherally Inserted Central Catheters: Guideline for Practice. 3rd ed, ed. N.A.o.N. Nurses. 2015"},{"issue":"1S Suppl 1","key":"3119_CR15","doi-asserted-by":"publisher","first-page":"S1","DOI":"10.1097\/NAN.0000000000000396","volume":"44","author":"LA Gorski","year":"2021","unstructured":"Gorski LA, Hadaway L, Hagle ME, Broadhurst D, Clare S, Kleidon T, et al. Infusion therapy standards of practice, 8th. J Infus Nurs. 2021;44(1S Suppl 1):S1\u2013S224. https:\/\/doi.org\/10.1097\/NAN.0000000000000396.","journal-title":"J Infus Nurs"},{"issue":"3","key":"3119_CR16","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1016\/j.clae.2012.01.003","volume":"35","author":"A Panaser","year":"2012","unstructured":"Panaser A, Tighe BJ. Function of lipids \u2212 their fate in contact lens wear: an interpretive review. Contact Lens Anterior Eye. 2012;35(3):100\u201311. https:\/\/doi.org\/10.1016\/j.clae.2012.01.003.","journal-title":"Contact Lens Anterior Eye"},{"issue":"1","key":"3119_CR17","doi-asserted-by":"publisher","first-page":"53","DOI":"10.5863\/1551-6776-25.1.53","volume":"25","author":"EA Omran","year":"2020","unstructured":"Omran EA, Eisa FF, Bakr W. Microbial contamination of neonatal injectable lipid emulsions at 12 and 24 hours infusion time with evaluation of infection control measures. J Pediatr Pharmacol Ther. 2020;25(1):53\u201360. https:\/\/doi.org\/10.5863\/1551-6776-25.1.53.","journal-title":"J Pediatr Pharmacol Ther"}],"container-title":["BMC Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12887-022-03119-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12887-022-03119-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12887-022-03119-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,1,30]],"date-time":"2022-01-30T23:19:07Z","timestamp":1643584747000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcpediatr.biomedcentral.com\/articles\/10.1186\/s12887-022-03119-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,31]]},"references-count":17,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["3119"],"URL":"https:\/\/doi.org\/10.1186\/s12887-022-03119-2","relation":{},"ISSN":["1471-2431"],"issn-type":[{"value":"1471-2431","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,31]]},"assertion":[{"value":"28 October 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 January 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 January 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study design and procedures (MRC-01-20-890) were approved by the local Institution Review Board (IRB). As the data source was anonymized, the local IRB committee determined the study an \u2018observational chart review\u2019 and that participant consent was not required. All methods were performed in accordance with the relevant guidelines and regulations.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not Applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"This research received no specific grant from any funding agency in the public, commercial or not-for-profit sectors. The local IRB made funds available to support open publication of this article.All contributing authors declare no financial disclosures, conflicts, or competing interests in the development of this research. No industry funding, grants or sponsorship was received in the development of this research.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"71"}}