{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,27]],"date-time":"2026-09-27T11:37:02Z","timestamp":1790509022875,"version":"4.1.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,11,28]],"date-time":"2023-11-28T00:00:00Z","timestamp":1701129600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,11,28]],"date-time":"2023-11-28T00:00:00Z","timestamp":1701129600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"the Program of Key science and technology research,Health Commission of Hebei Province","award":["Project No. 20191074"],"award-info":[{"award-number":["Project No. 20191074"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Pediatr"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The objective of this study was to evaluate intraobserver reliability and inter-observer reproducibility of a 3-dimensional (3D) assessment method for mandibular changes of growing patients after orthodontic treatment for Class III malocclusion.<\/jats:p>\n                  <jats:p>\n                    <jats:bold>Methods<\/jats:bold>\n                    Cone-beam computed tomography (CBCT) scans were performed before and after orthodontic treatment for 27 patients. During the scan, the patient was positioned such that his\/her mandibular plane was parallel to floor. Three observers independently worked on the DICOM data, reconstructed the pre- and post-treatment 3D models in software, selected the stable anatomical structures (basal bone area from the lingual surface of the symphysis to the distal aspect of the first molars) to guide the automated superimposition process. Then, each observer registered 14 anatomical landmarks on the virtual models, for three times after suitable interval, to generate 3 sets of coordinates; the mean was taken as the coordinates for that particular landmark. The intraobserver reliability and inter-observer reproducibility of the method were analyzed.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Results<\/jats:bold>\n                    The ICCs was\u2009&gt;\u20090.90 for 25 (92.6%) of the intraobserver assessments. The precision of the measurement method was\u2009&lt;\u20090.3\u00a0mm in 24 (88.9%) cases. The interobserver reproducibility errors were\u2009&lt;\u20090.3\u00a0mm in 21 of the 27 cases.\n                  <\/jats:p>\n                  <jats:p>\n                    <jats:bold>Conclusions<\/jats:bold>\n                    The intraobserver reliability and inter-observer reproducibility of 3D assessment of mandibular changes using the virtual models were excellent.\n                  <\/jats:p>","DOI":"10.1186\/s12887-023-04404-4","type":"journal-article","created":{"date-parts":[[2023,11,28]],"date-time":"2023-11-28T06:04:22Z","timestamp":1701151462000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Reliability and reproducibility of CBCT assessment of mandibular changes before and after treatment for Class III growing patients \u2013 an easy and quick way for evaluation"],"prefix":"10.1186","volume":"23","author":[{"given":"XiaoYing","family":"Hu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gary Shun Pan","family":"Cheung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"YiYang","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"RuoNan","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"FuSheng","family":"Dong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,11,28]]},"reference":[{"issue":"1","key":"4404_CR1","doi-asserted-by":"publisher","first-page":"59","DOI":"10.34172\/joddd.2021.011","volume":"15","author":"SR Iyer","year":"2021","unstructured":"Iyer SR, Premkumar S, Muruganandam M. Skeletal and dental changes induced by the Flip-Lock Herbst appliance in the treatment of Angle\u2019s Class II division 1 malocclusion during active growth period: a preliminary study. J Dent Res Dent Clin Dent Prospects. 2021;15(1):59\u201365. https:\/\/doi.org\/10.34172\/joddd.2021.011. Epub 2021 Feb 13. PMID: 33927843; PMCID: PMC8058159.","journal-title":"J Dent Res Dent Clin Dent Prospects."},{"issue":"1","key":"4404_CR2","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13005-020-0215-7","volume":"16","author":"C Ponce-Garcia","year":"2020","unstructured":"Ponce-Garcia C, Ruellas ACO, Cevidanes LHS, Flores-Mir C, Carey JP, Lagravere-Vich M. Measurement error and reliability of three available 3D superimposition methods in growing patients. Head Face Med. 2020;16(1):1.","journal-title":"Head Face Med"},{"issue":"4","key":"4404_CR3","first-page":"341","volume":"34","author":"YW Cheong","year":"2011","unstructured":"Cheong YW, Lo LJ. Facial asymmetry: etiology, evaluation, and management. Chang Gung Med J. 2011;34(4):341\u201351. PMID: 21880188.","journal-title":"Chang Gung Med J."},{"issue":"2","key":"4404_CR4","doi-asserted-by":"publisher","first-page":"1100639","DOI":"10.1016\/j.ortho.2022.100639","volume":"20","author":"MY Hajeer","year":"2022","unstructured":"Hajeer MY, Al-Homsi HK, Alfailany DT, Murad RMT. Evaluation of the diagnostic accuracy of CBCT -based interpretations of maxillary impacted canines compared to those of conventional radiography: An in vitro study. Int Orthod. 2022;20(2):1100639. https:\/\/doi.org\/10.1016\/j.ortho.2022.100639. Epub 2022 May 21. PMID:35606269.","journal-title":"Int Orthod."},{"issue":"8","key":"4404_CR5","doi-asserted-by":"publisher","first-page":"648","DOI":"10.5005\/jp-journals-10024-1736","volume":"16","author":"HK Al-Homsi","year":"2015","unstructured":"Al-Homsi HK, Hajeer MY. An evaluation of inter- and intraobserver reliability of cone-beam computed tomography and two dimensional-based interpretations of maxillary canine impactions using a panel of orthodontically trained observers. J Contemp Dent Pract. 2015;16(8):648\u201356. https:\/\/doi.org\/10.5005\/jp-journals-10024-1736. PMID: 26423501.","journal-title":"J Contemp Dent Pract"},{"issue":"4","key":"4404_CR6","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1111\/ocr.12205","volume":"20","author":"A Ghoneima","year":"2017","unstructured":"Ghoneima A, Cho H, Farouk K, Kula K. Accuracy and reliability of landmark-based, surface-based and voxel-based 3D cone-beam computed tomography superimposition methods. Orthod Craniofac Res. 2017;20(4):227\u201336. https:\/\/doi.org\/10.1111\/ocr.12205. Epub 2017 Sep 27 PMID: 28960842.","journal-title":"Orthod Craniofac Res"},{"issue":"1","key":"4404_CR7","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1186\/s40510-021-00391-3","volume":"22","author":"MY Hajeer","year":"2021","unstructured":"Hajeer MY, Al-Homsi HK, Alfailany DT, Murad RMT. Three-dimensional oropharyngeal airway changes after facemask therapy using low-dose computed tomography: a clinical trial with a retrospectively collected control group. Prog Orthod. 2021;22(1):50. https:\/\/doi.org\/10.1186\/s40510-021-00391-3. PMID:34939164;PMCID:PMC8695404.","journal-title":"Prog Orthod"},{"key":"4404_CR8","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1016\/j.ajodo.2005.11.031","volume":"129","author":"MO Lagrav\u00e8re","year":"2006","unstructured":"Lagrav\u00e8re MO, Hansen L, Harzer W, Majord PW. Plane orientation for standardization in 3-dimensional cephalometric analysis with computerized tomography imaging. Am J Orthod. 2006;129:601\u20134.","journal-title":"Am J Orthod"},{"key":"4404_CR9","doi-asserted-by":"publisher","first-page":"1775","DOI":"10.1007\/s00784-020-03480-5","volume":"25","author":"RM Leonardi","year":"2021","unstructured":"Leonardi RM, Aboulazm K, Giudice AL, et al. Evaluation of mandibular changes after rapid maxillary expansion: a CBCT study in youngsters with unilateral posterior crossbite using a surface-to-surface matching technique. Clin Oral Investig. 2021;25:1775\u201385. https:\/\/doi.org\/10.1007\/s00784-020-03480-5.","journal-title":"Clin Oral Investig"},{"issue":"5","key":"4404_CR10","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1016\/j.ajodo.2017.07.026","volume":"153","author":"T Nguyen","year":"2018","unstructured":"Nguyen T, Cevidanes L, Franchi L, Ruellas A, Jackson T. Three-dimensional mandibular regional superimposition in growing patients. Am J Orthod Dentofacial Orthop. 2018;153(5):747\u201354.","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"4404_CR11","first-page":"473","volume":"87","author":"L Koerich","year":"2017","unstructured":"Koerich L, Weissheimer A, de Menezes LM, Lindauer SJ. Rapid 3D mandibular superimposition for growing patients. Am J Orthod. 2017;87:473\u20139.","journal-title":"Am J Orthod"},{"key":"4404_CR12","doi-asserted-by":"publisher","unstructured":"Husson AH, Burhan AS, Hajeer MY, Nawaya FR. Evaluation of the dimensional changes in the mandible, condyles, and the temporomandibular joint following skeletal Class III treatment with chin cup and bonded maxillary bite block using low-dose computed tomography: A single-center, randomized controlled trial.2023;12:264.\u00a0https:\/\/doi.org\/10.12688\/f1000research.130941.1. PMID:37008891; PMCID:PMC10050907.","DOI":"10.12688\/f1000research.130941.1"},{"key":"4404_CR13","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1186\/s12903-022-02131-3","volume":"22","author":"B Baldini","year":"2022","unstructured":"Baldini B, Cavagnetto D, Baselli G, et al. Cephalometric measurements performed on CBCT and reconstructed lateral cephalograms: a cross-sectional study providing a quantitative approach of differences and bias. BMC Oral Health. 2022;22:98. https:\/\/doi.org\/10.1186\/s12903-022-02131-3.","journal-title":"BMC Oral Health"},{"issue":"4","key":"4404_CR14","doi-asserted-by":"publisher","first-page":"e93402","DOI":"10.1371\/journal.pone.0093402","volume":"9","author":"A Almukhtar","year":"2014","unstructured":"Almukhtar A, Ju X, Khambay B, McDonald J, Ayoub A. Comparison of the accuracy of voxel based registration and surface based registration for 3D assessment of surgical change following orthognathic surgery. PLoS One. 2014;9(4):e93402. https:\/\/doi.org\/10.1371\/journal.pone.0093402.","journal-title":"PLoS One"},{"issue":"6","key":"4404_CR15","doi-asserted-by":"publisher","first-page":"822","DOI":"10.2319\/013021-86.1","volume":"91","author":"R Leonardi","year":"2021","unstructured":"Leonardi R, Ronsivalle V, Lagravere MO, Barbato E, Isola G, Giudice AL. Three-dimensional assessment of the spheno-occipital synchondrosis and clivus after tooth-borne and bone-borne rapid maxillary expansion: A retrospective CBCT study using voxel-based superimposition. Angle Orthod. 2021;91(6):822\u20139. https:\/\/doi.org\/10.2319\/013021-86.1.","journal-title":"Angle Orthod."},{"issue":"9","key":"4404_CR16","doi-asserted-by":"publisher","first-page":"1188","DOI":"10.1016\/j.ijom.2015.04.001","volume":"44","author":"A Weissheimer","year":"2015","unstructured":"Weissheimer A, Menezes LM, Koerich L, Pham J, Cevidanes LH. Fast three-dimensional superimposition of cone beam computed tomography for orthopaedics and orthognathic surgery evaluation. Int J Oral Maxillofac Surg. 2015;44(9):1188\u201396.","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"9","key":"4404_CR17","doi-asserted-by":"publisher","first-page":"1238","DOI":"10.1164\/rccm.201805-0977LE","volume":"198","author":"XY Hu","year":"2018","unstructured":"Hu XY, Xu JT, Dong FS. How to determine the patient\u2019s head and neck posture during the CT scanning? Am J Respir Crit Care Med. 2018;198(9):1238.","journal-title":"Am J Respir Crit Care Med"},{"issue":"3","key":"4404_CR18","doi-asserted-by":"publisher","first-page":"e22789","DOI":"10.7759\/cureus.22789","volume":"14","author":"HI Alsino","year":"2022","unstructured":"Alsino HI, Alsino HI, Hajeer MY, Alkhouri I, Murad RMT. The diagnostic accuracy of cone-beam computed tomography (CBCT) imaging in detecting and measuring dehiscence and fenestration in patients with Class I malocclusion: a surgical-exposure-based validation study. Cureus. 2022;14(3):e22789. https:\/\/doi.org\/10.7759\/cureus.22789. PMID:35291727;PMCID:PMC8896840.","journal-title":"Cureus"},{"issue":"1","key":"4404_CR19","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1186\/s12903-019-0891-5","volume":"19","author":"T Dong","year":"2019","unstructured":"Dong T, Xia L, Cai C, Yuan L, Ye N, Fang B. Accuracy of in vitro mandibular volumetric measurements from CBCT of different voxel sizes with different segmentation threshold settings. BMC Oral Health. 2019;19(1):206. https:\/\/doi.org\/10.1186\/s12903-019-0891-5. PMID:31484529;PMCID:PMC6727515.","journal-title":"BMC Oral Health"},{"issue":"1","key":"4404_CR20","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1111\/ocr.12347","volume":"23","author":"ST H\u00e4ner","year":"2020","unstructured":"H\u00e4ner ST, Kanavakis G, Matthey F, Gkantidis N. Voxel-based superimposition of serial craniofacial CBCTs: Reliability, reproducibility and segmentation effect on hard-tissue outcomes. Orthod Craniofac Res. 2020;23(1):92\u2013101. https:\/\/doi.org\/10.1111\/ocr.12347. Epub 2019 Oct 1 PMID: 31529585.","journal-title":"Orthod Craniofac Res"},{"key":"4404_CR21","doi-asserted-by":"publisher","unstructured":"Koerich L, Tufekci E, Lindauer SJ. 3D Imaging to Assess Growth and Treatment Effects. In: Kadioglu O, Currier G, editors. Craniofacial 3D Imaging. Cham: Springer; 2019. https:\/\/doi.org\/10.1007\/978-3-030-00722-5_3.","DOI":"10.1007\/978-3-030-00722-5_3"},{"issue":"17","key":"4404_CR22","doi-asserted-by":"publisher","first-page":"5229","DOI":"10.3390\/jcm11175229","volume":"11","author":"C Zhang","year":"2022","unstructured":"Zhang C, Ji L, Li Y, Pan F, Liao W, Zhao Z. A novel method to combine maxilla-based coordinate system and mandibular voxel-based superimposition with cone-beam computed tomography. J Clin Med. 2022;11(17):5229. https:\/\/doi.org\/10.3390\/jcm11175229. PMID:36079159;PMCID:PMC9456660.","journal-title":"J Clin Med"},{"issue":"4","key":"4404_CR23","doi-asserted-by":"publisher","first-page":"294","DOI":"10.5005\/jp-journals-10024-1844","volume":"17","author":"AL Maroua","year":"2016","unstructured":"Maroua AL, Ajaj M, Hajeer MY. The accuracy and reproducibility of linear measurements made on CBCT-derived digital models. J Contemp Dent Pract. 2016;17(4):294\u20139. https:\/\/doi.org\/10.5005\/jp-journals-10024-1844. PMID: 27340163.","journal-title":"J Contemp Dent Pract"}],"container-title":["BMC Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12887-023-04404-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12887-023-04404-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12887-023-04404-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,28]],"date-time":"2023-11-28T06:06:34Z","timestamp":1701151594000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcpediatr.biomedcentral.com\/articles\/10.1186\/s12887-023-04404-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,28]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["4404"],"URL":"https:\/\/doi.org\/10.1186\/s12887-023-04404-4","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-2494364\/v1","asserted-by":"object"}]},"ISSN":["1471-2431"],"issn-type":[{"value":"1471-2431","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,28]]},"assertion":[{"value":"19 January 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 November 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 November 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All experiments were performed in accordance with relevant guidelines and regulations (Declarations of Helsinki).Study protocol was approved by the Medical Ethical Commission of the Hebei Medical University.The informed consents from all subjects and\/or their legal guardian(s) have been obtained for study participation.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The informed consents from all subjects and\/or their legal guardian(s) have been obtained for publication of identifying information\/images in an online open-access publication.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"602"}}