{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T20:20:07Z","timestamp":1784233207473,"version":"3.55.0"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,12,9]],"date-time":"2023-12-09T00:00:00Z","timestamp":1702080000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,12,9]],"date-time":"2023-12-09T00:00:00Z","timestamp":1702080000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Chinese Nursing Association","award":["ZHKY202101"],"award-info":[{"award-number":["ZHKY202101"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Pediatr"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Introduction<\/jats:title>\n                <jats:p>In recent years, intracardiac electrocardiogram (IC-ECG) technology has been widely used for epicutaneo-cava catheter (ECC) placement and has shown many potential advantages. However, evidence about the quantitative changes, effectiveness, and safety of IC-ECG for lower extremity ECC is sparse. This study aimed to explore the quantitative changes in IC-ECG for lower extremity ECC and determine its effectiveness and safety.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>A retrospective study was conducted on 303 premature infants who underwent successful IC-ECG-guided lower extremity ECC placement between January 2019 and December 2021. All patients underwent chest X-ray postoperatively to verify the position of the catheter tip. The amplitudes of the surface electrocardiogram and IC-ECG QRS waves and the difference between the two amplitudes were measured. The effectiveness (matching rate between IC-ECG and chest X-ray) and safety (incidence of catheter-related complications) of IC-ECG for lower extremity ECC were evaluated.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The matching rate between IC-ECG and chest X-ray was 95.0%. When the catheter tip was optimally positioned, the QRS amplitude of the IC-ECG was 0.85\u2009\u00b1\u20090.56 mv higher than that of the surface electrocardiogram. The overall incidence of catheter-related complications was 10.6%. The actual ECC insertion length was associated with a noticeably increased risk of catheter-related complications.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>This study suggests that IC-ECG is an effective and safe method by observing the dynamic changes in both QRS complexes and P wave to locate the tip of lower extremity ECC in preterm infants. Our findings would facilitate the application of IC-ECG for ECC localization.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12887-023-04444-w","type":"journal-article","created":{"date-parts":[[2023,12,9]],"date-time":"2023-12-09T06:01:48Z","timestamp":1702101708000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Effectiveness and safety of intracardiac electrocardiogram guidance for epicutaneo-cava catheters via the lower extremity in preterm infants: a retrospective study"],"prefix":"10.1186","volume":"23","author":[{"given":"Xinying","family":"Yu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Li","family":"Gai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuejun","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chaonan","family":"Kong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Na","family":"Cao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ling","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fan","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoyu","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Le","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,12,9]]},"reference":[{"issue":"12","key":"4444_CR1","doi-asserted-by":"publisher","first-page":"1676","DOI":"10.1007\/s00247-017-3939-1","volume":"47","author":"B Goldwasser","year":"2017","unstructured":"Goldwasser B, Baia C, Kim M, Taragin BH, Angert RM. Non-central peripherally inserted central catheters in neonatal intensive care: complication rates and longevity of catheters relative to tip position. Pediatr Radiol. 2017;47(12):1676\u201381. https:\/\/doi.org\/10.1007\/s00247-017-3939-1.","journal-title":"Pediatr Radiol"},{"issue":"4","key":"4444_CR2","doi-asserted-by":"publisher","first-page":"307","DOI":"10.1038\/jp.2012.112","volume":"33","author":"A Jain","year":"2013","unstructured":"Jain A, Deshpande P, Shah P. Peripherally inserted central catheter tip position and risk of associated Complications in neonates. J Perinatol. 2013;33(4):307\u201312. https:\/\/doi.org\/10.1038\/jp.2012.112.","journal-title":"J Perinatol"},{"issue":"6","key":"4444_CR3","doi-asserted-by":"publisher","first-page":"636","DOI":"10.1177\/1129729819838136","volume":"20","author":"T Yu","year":"2019","unstructured":"Yu T, Wu L, Yuan L, Dawson R, Li R, Qiu Z, et al. The diagnostic value of intracavitary electrocardiogram for verifying tip position of peripherally inserted central catheters in cancer patients: a retrospective multicenter study. J Vasc Access. 2019;20(6):636\u201345. https:\/\/doi.org\/10.1177\/1129729819838136.","journal-title":"J Vasc Access"},{"key":"4444_CR4","doi-asserted-by":"publisher","unstructured":"Gorski LA, Hadaway L, Hagle ME, Broadhurst D, Clare S, Kleidon T et al. Infusion Therapy Standards of Practice, 8th Edition. J Infus Nurs. 2021;44:S1\u2013S224. https:\/\/doi.org\/10.1097\/NAN.0000000000000396.","DOI":"10.1097\/NAN.0000000000000396"},{"issue":"2","key":"4444_CR5","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1177\/1129729818781266","volume":"20","author":"C Monard","year":"2019","unstructured":"Monard C, Lef\u00e8vre M, Subtil F, Piriou V, David JS. Peripherally inserted central catheter with intracavitary electrocardiogram guidance: Malposition risk factors and indications for post-procedural control. J Vasc Access. 2019;20(2):128\u201333. https:\/\/doi.org\/10.1177\/1129729818781266.","journal-title":"J Vasc Access"},{"issue":"3","key":"4444_CR6","doi-asserted-by":"publisher","first-page":"439","DOI":"10.1007\/s00431-019-03524-3","volume":"179","author":"AQ Xiao","year":"2020","unstructured":"Xiao AQ, Sun J, Zhu LH, Liao ZY, Shen P, Zhao LL, et al. Effectiveness of intracavitary electrocardiogram-guided peripherally inserted central catheter tip placement in premature infants: a multicentre pre-post intervention study. Eur J Pediatr. 2020;179(3):439\u201346. https:\/\/doi.org\/10.1007\/s00431-019-03524-3.","journal-title":"Eur J Pediatr"},{"issue":"6","key":"4444_CR7","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1177\/1129729819826028","volume":"20","author":"G Liu","year":"2019","unstructured":"Liu G, Hou W, Zhou C, Yin Y, Lu S, Duan C, et al. Meta-analysis of intracavitary electrocardiogram guidance for peripherally inserted central catheter placement. J Vasc Access. 2019;20(6):577\u201382. https:\/\/doi.org\/10.1177\/1129729819826028.","journal-title":"J Vasc Access"},{"issue":"1","key":"4444_CR8","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1097\/JPN.0000000000000389","volume":"33","author":"Q Ling","year":"2019","unstructured":"Ling Q, Chen H, Tang M, Qu Y, Tang B. Accuracy and Safety Study of Intracavitary Electrocardiographic Guidance for Peripherally Inserted Central Catheter Placement in neonates. J Perinat Neonatal Nurs. 2019;33(1):89\u201395. https:\/\/doi.org\/10.1097\/JPN.0000000000000389.","journal-title":"J Perinat Neonatal Nurs"},{"issue":"2","key":"4444_CR9","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1177\/1129729819865812","volume":"21","author":"MD Weber","year":"2020","unstructured":"Weber MD, Himebauch AS, Conlon T. Repositioning of malpositioned peripherally inserted central catheter lines with the use of intracavitary electrocardiogram: a pediatric case series. J Vasc Access. 2020;21(2):259\u201364. https:\/\/doi.org\/10.1177\/1129729819865812.","journal-title":"J Vasc Access"},{"issue":"4","key":"4444_CR10","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1097\/JPN.0000000000000264","volume":"31","author":"L Zhou","year":"2017","unstructured":"Zhou L, Xu H, Liang J, Xu M, Yu J. Effectiveness of Intracavitary Electrocardiogram Guidance in peripherally inserted Central Catheter Tip Placement in neonates. J Perinat Neonatal Nurs. 2017;31(4):326\u201331. https:\/\/doi.org\/10.1097\/JPN.0000000000000264.","journal-title":"J Perinat Neonatal Nurs"},{"key":"4444_CR11","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1515\/med-2017-0019","volume":"12","author":"LJ Zhou","year":"2017","unstructured":"Zhou LJ, Xua HZ, Xu MF, Hu Y, Lou XF. An Accuracy Study of the Intracavitary Electrocardiogram (IC-ECG) guided peripherally inserted Central Catheter Tip Placement among neonates. Open Med (Wars). 2017;12:125\u201330. https:\/\/doi.org\/10.1515\/med-2017-0019.","journal-title":"Open Med (Wars)"},{"issue":"10","key":"4444_CR12","doi-asserted-by":"publisher","first-page":"10228","DOI":"10.21037\/apm-21-1893","volume":"10","author":"X Wang","year":"2021","unstructured":"Wang X, Yang Y, Dong J, Wang X, Zheng Y, Chen J, et al. A comparative study on the tip position of peripherally inserted central catheter inserted at two forward P-wave amplitudes by intracavitary electrocardiogram in cancer patients. Ann Palliat Med. 2021;10(10):10228\u201335. https:\/\/doi.org\/10.21037\/apm-21-1893.","journal-title":"Ann Palliat Med"},{"issue":"8","key":"4444_CR13","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1177\/0268355520921357","volume":"35","author":"YX Yin","year":"2020","unstructured":"Yin YX, Gao W, Li XY, Lu W, Deng QH, Zhao CY, et al. Randomized multicenter study on long-term Complications of peripherally inserted central catheters positioned by electrocardiographic technique. Phlebology. 2020;35(8):614\u201322. https:\/\/doi.org\/10.1177\/0268355520921357.","journal-title":"Phlebology"},{"issue":"10","key":"4444_CR14","doi-asserted-by":"publisher","first-page":"2409","DOI":"10.21037\/tp-20-370","volume":"10","author":"LB Zhu","year":"2021","unstructured":"Zhu LB, Liu L, Zhang TS, Zheng YT, Lu CY, Lu K, et al. A clinical study on the tip localization of peripherally inserted central catheter (PICC) guided by intracavitary electrocardiography in newborns: a randomised trial. Transl Pediatr. 2021;10(10):2409\u201317. https:\/\/doi.org\/10.21037\/tp-20-370.","journal-title":"Transl Pediatr"},{"issue":"2","key":"4444_CR15","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1177\/1129729819891565","volume":"22","author":"SS Zhu","year":"2021","unstructured":"Zhu SS, Zhao J, Zhou XY, Gao W, Pan MH, Yu WW, et al. Influence of arm position change from adduction to Abduction on intracavitary electrocardiogram. J Vasc Access. 2021;22(2):292\u20138. https:\/\/doi.org\/10.1177\/1129729819891565.","journal-title":"J Vasc Access"},{"issue":"6","key":"4444_CR16","doi-asserted-by":"publisher","first-page":"542","DOI":"10.1177\/1129729818761292","volume":"19","author":"A Capasso","year":"2018","unstructured":"Capasso A, Mastroianni R, Passariello A, Palma M, Messina F, Ansalone A, et al. The intracavitary electrocardiography method for positioning the tip of epicutaneous cava catheter in neonates: pilot study. J Vasc Access. 2018;19(6):542\u20137. https:\/\/doi.org\/10.1177\/1129729818761292.","journal-title":"J Vasc Access"},{"issue":"3","key":"4444_CR17","doi-asserted-by":"publisher","first-page":"497","DOI":"10.12182\/20210560506","volume":"52","author":"BZ Tang","year":"2021","unstructured":"Tang BZ, Chen CH, Chen H, Ling QY. RCT of reduction in catheter-related Complications by using Intracavitary Electrocardiogram-assisted Guidance in neonatal PICC Placement. Sichuan Da Xue Xue Bao Yi Xue Ban. 2021;52(3):497\u2013502. https:\/\/doi.org\/10.12182\/20210560506.","journal-title":"Sichuan Da Xue Xue Bao Yi Xue Ban"},{"key":"4444_CR18","doi-asserted-by":"publisher","first-page":"570978","DOI":"10.3389\/fped.2020.570978","volume":"8","author":"X Yu","year":"2020","unstructured":"Yu X, Wang X, Fan L, Cao N, Yang F, Li J, et al. Iatrogenic pleural effusion due to Extravasation of Parenteral Nutrition via an Epicutaneo Cava Catheter in neonates: a prospective cohort study. Front Pediatr. 2020;8:570978. https:\/\/doi.org\/10.3389\/fped.2020.570978.","journal-title":"Front Pediatr"},{"issue":"3","key":"4444_CR19","doi-asserted-by":"publisher","first-page":"1556","DOI":"10.1002\/nop2.932","volume":"9","author":"C Yu","year":"2022","unstructured":"Yu C, Shulan L, Juan W, Ling L, Chun-Mei L. The accuracy and safety of using the electrocardiogram positioning technique in localizing the peripherally inserted central catheter tip position: a systematic review and meta-analysis. Nurs Open. 2022;9(3):1556\u201363. https:\/\/doi.org\/10.1002\/nop2.932.","journal-title":"Nurs Open"},{"key":"4444_CR20","doi-asserted-by":"publisher","first-page":"112972982211001","DOI":"10.1177\/11297298221100174","volume":"30","author":"S Zhang","year":"2022","unstructured":"Zhang S, Zhu Y, Du Y, Yin X. The positioning of the catheter tip with an intracavitary electrocardiogram in epicutaneo-caval catheter placement via lower limbs in newborns: a retrospective study. J Vasc Access. 2022;30:11297298221100174. https:\/\/doi.org\/10.1177\/11297298221100174.","journal-title":"J Vasc Access"},{"issue":"1","key":"4444_CR21","doi-asserted-by":"publisher","first-page":"57","DOI":"10.3233\/NPM-1817","volume":"12","author":"A Elmekkawi","year":"2019","unstructured":"Elmekkawi A, Maulidi H, Mak W, Aziz A, Lee KS. Outcomes of upper extremity versus lower extremity placed peripherally inserted central catheters in a medical-surgical neonatal intensive care unit1. J Neonatal Perinatal Med. 2019;12(1):57\u201363. https:\/\/doi.org\/10.3233\/NPM-1817.","journal-title":"J Neonatal Perinatal Med"},{"key":"4444_CR22","doi-asserted-by":"publisher","first-page":"102753","DOI":"10.1016\/j.iccn.2019.08.003","volume":"56","author":"H Chen","year":"2020","unstructured":"Chen H, Zhang X, Wang H, Hu X. Complications of upper extremity versus lower extremity placed peripherally inserted central catheters in neonatal intensive care units: a meta-analysis. Intensive Crit Care Nurs. 2020;56:102753. https:\/\/doi.org\/10.1016\/j.iccn.2019.08.003.","journal-title":"Intensive Crit Care Nurs"},{"issue":"1","key":"4444_CR23","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1097\/NHH.0000000000000481","volume":"35","author":"LA Gorski","year":"2017","unstructured":"Gorski LA. The 2016 infusion Therapy standards of Practice. Home Healthc Now. 2017;35(1):10\u20138. https:\/\/doi.org\/10.1097\/NHH.0000000000000481.","journal-title":"Home Healthc Now"},{"issue":"3","key":"4444_CR24","doi-asserted-by":"publisher","first-page":"201","DOI":"10.7499\/j.issn.1008-8830.2101087","volume":"23","author":"N Society","year":"2021","unstructured":"Evidence-Based Medicine Group, Society N, Chinese Medical Doctor Association. Operation and management guidelines for peripherally inserted central catheter in neonates (2021). Zhongguo Dang Dai Er Ke Za Zhi. 2021;23(3):201\u201312. https:\/\/doi.org\/10.7499\/j.issn.1008-8830.2101087.","journal-title":"Zhongguo Dang Dai Er Ke Za Zhi"},{"issue":"4","key":"4444_CR25","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1177\/1129729820958334","volume":"22","author":"M Ma","year":"2021","unstructured":"Ma M, Zhang J, Hou J, Gong Z, Hu Z, Chen S, et al. The application of intracavitary electrocardiogram for tip location of femoral vein catheters in chemotherapy patients with superior vena cava obstruction. J Vasc Access. 2021;22(4):613\u201322. https:\/\/doi.org\/10.1177\/1129729820958334.","journal-title":"J Vasc Access"},{"issue":"5","key":"4444_CR26","doi-asserted-by":"publisher","first-page":"679","DOI":"10.1177\/11297298211007703","volume":"23","author":"G Barone","year":"2022","unstructured":"Barone G, Pittiruti M, Biasucci DG, Elisei D, Iacobone E, La Greca A, et al. Neo-ECHOTIP: a structured protocol for ultrasound-based tip navigation and tip location during placement of central venous access devices in neonates. J Vasc Access. 2022;23(5):679\u201388. https:\/\/doi.org\/10.1177\/11297298211007703.","journal-title":"J Vasc Access"},{"issue":"10","key":"4444_CR27","doi-asserted-by":"publisher","first-page":"945","DOI":"10.1055\/s-0036-1582127","volume":"33","author":"RA Bashir","year":"2016","unstructured":"Bashir RA, Swarnam K, Vayalthrikkovil S, Yee W, Soraisham AS. Association between peripherally inserted central venous catheter insertion site and complication rates in Preterm infants. Am J Perinatol. 2016;33(10):945\u201350. https:\/\/doi.org\/10.1055\/s-0036-1582127.","journal-title":"Am J Perinatol"},{"issue":"4","key":"4444_CR28","doi-asserted-by":"publisher","first-page":"320","DOI":"10.5301\/jva.5000157","volume":"14","author":"S Ozkiraz","year":"2013","unstructured":"Ozkiraz S, Gokmen Z, Anuk Ince D, Akcan AB, Kilicdag H, Ozel D, et al. Peripherally inserted central venous catheters in critically ill premature neonates. J Vasc Access. 2013;14(4):320\u20134. https:\/\/doi.org\/10.5301\/jva.5000157.","journal-title":"J Vasc Access"},{"issue":"7","key":"4444_CR29","doi-asserted-by":"publisher","first-page":"e14210","DOI":"10.1111\/ijcp.14210","volume":"75","author":"J Wu","year":"2021","unstructured":"Wu J, Li J, Li H, Lei X, Liu H. Comparison of formula-based PICC catheterisation versus common method for the treatment of newborns. Int J Clin Pract. 2021;75(7):e14210. https:\/\/doi.org\/10.1111\/ijcp.14210.","journal-title":"Int J Clin Pract"},{"issue":"4","key":"4444_CR30","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1097\/JPN.0000000000000585","volume":"35","author":"DY Kim","year":"2021","unstructured":"Kim DY, Park HR. Estimating the insertion depth of a peripherally inserted Central Catheter in newborns using weight and gestational age measurements. J Perinat Neonatal Nurs. 2021;35(4):362\u20138. https:\/\/doi.org\/10.1097\/JPN.0000000000000585.","journal-title":"J Perinat Neonatal Nurs"},{"issue":"4","key":"4444_CR31","doi-asserted-by":"publisher","first-page":"314","DOI":"10.1097\/ANC.0000000000000817","volume":"21","author":"D Armbruster","year":"2021","unstructured":"Armbruster D, Slaughter J, Stenger M, Warren P. Neonatal anthropometric measures and peripherally inserted central catheter depth. Adv Neonatal Care. 2021;21(4):314\u201321. https:\/\/doi.org\/10.1097\/ANC.0000000000000817.","journal-title":"Adv Neonatal Care"},{"issue":"50","key":"4444_CR32","doi-asserted-by":"publisher","first-page":"e18368","DOI":"10.1097\/MD.0000000000018368","volume":"98","author":"L Yang","year":"2019","unstructured":"Yang L, Bing X, Song L, Na C, Minghong D, Annuo L. Intracavitary electrocardiogram guidance for placement of peripherally inserted central catheters in premature infants. Med (Baltim). 2019;98(50):e18368. https:\/\/doi.org\/10.1097\/MD.0000000000018368.","journal-title":"Med (Baltim)"},{"issue":"1","key":"4444_CR33","doi-asserted-by":"publisher","first-page":"166","DOI":"10.1177\/1129729820982864","volume":"23","author":"MD Weber","year":"2022","unstructured":"Weber MD, Himebauch AS, Conlon T. Use of intracavitary-ECG for tip location of femorally inserted central catheters. J Vasc Access. 2022;23(1):166\u201370. https:\/\/doi.org\/10.1177\/1129729820982864.","journal-title":"J Vasc Access"},{"issue":"2","key":"4444_CR34","doi-asserted-by":"publisher","first-page":"e12922","DOI":"10.1111\/anec.12922","volume":"27","author":"Y Duan","year":"2022","unstructured":"Duan Y, Hu X, Zhu Y, Zhao X, Yin X, Zhang H, et al. Intracavitary electrocardiography for femorally inserted central catheter tip location in adult patients. Ann Noninvasive Electrocardiol. 2022;27(2):e12922. https:\/\/doi.org\/10.1111\/anec.12922.","journal-title":"Ann Noninvasive Electrocardiol"},{"issue":"4","key":"4444_CR35","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1111\/j.1460-9592.2005.01433.x","volume":"15","author":"BC Tsui","year":"2005","unstructured":"Tsui BC, Richards GJ, Van Aerde J. Umbilical vein catheterization under electrocardiogram guidance. Paediatr Anaesth. 2005;15(4):297\u2013300. https:\/\/doi.org\/10.1111\/j.1460-9592.2005.01433.x.","journal-title":"Paediatr Anaesth"},{"key":"4444_CR36","doi-asserted-by":"publisher","first-page":"987512","DOI":"10.3389\/fped.2022.987512","volume":"31","author":"Y Wu","year":"2022","unstructured":"Wu Y, Yan J, Tang M, Hu Y, Wan X, Li X, et al. A review of neonatal peripherally inserted central venous catheters in extremely or very low birthweight infants based on a 3-year clinical practice: complication incidences and risk factors. Front Pediatr. 2022;31:10:987512. https:\/\/doi.org\/10.3389\/fped.2022.987512.","journal-title":"Front Pediatr"},{"issue":"3","key":"4444_CR37","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1097\/ANC.0b013e31827e1d01","volume":"13","author":"DD Wrightson","year":"2013","unstructured":"Wrightson DD. Peripherally inserted central catheter Complications in neonates with upper versus lower extremity insertion sites. Adv Neonatal Care. 2013;13(3):198\u2013204. https:\/\/doi.org\/10.1097\/ANC.0b013e31827e1d01.","journal-title":"Adv Neonatal Care"},{"key":"4444_CR38","doi-asserted-by":"publisher","first-page":"3769376","DOI":"10.1155\/2018\/3769376","volume":"2018","author":"X Yu","year":"2018","unstructured":"Yu X, Yue S, Wang M, Cao C, Liao Z, Ding Y, et al. Risk factors related to peripherally inserted central venous catheter nonselective removal in neonates. Biomed Res Int. 2018;2018:3769376. https:\/\/doi.org\/10.1155\/2018\/3769376.","journal-title":"Biomed Res Int"},{"issue":"5","key":"4444_CR39","doi-asserted-by":"publisher","first-page":"276","DOI":"10.4103\/jiaps.JIAPS_87_19","volume":"25","author":"K Patil","year":"2020","unstructured":"Patil K, Dhaded SM, Bhandankar M. A 1-Year study on Association between Peripherally Inserted Central Catheter Tip Position and Complications in neonates. J Indian Assoc Pediatr Surg. 2020;25(5):276\u20139. https:\/\/doi.org\/10.4103\/jiaps.JIAPS_87_19.","journal-title":"J Indian Assoc Pediatr Surg"},{"issue":"2","key":"4444_CR40","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1055\/s-0039-1694760","volume":"38","author":"XL Ren","year":"2021","unstructured":"Ren XL, Li HL, Liu J, Chen YJ, Wang M, Qiu RX. Ultrasound to localize the peripherally inserted Central Catheter tip position in Newborn infants. Am J Perinatol. 2021;38(2):122\u20135. https:\/\/doi.org\/10.1055\/s-0039-1694760.","journal-title":"Am J Perinatol"},{"issue":"5","key":"4444_CR41","doi-asserted-by":"publisher","first-page":"2097","DOI":"10.1007\/s00431-022-04412-z","volume":"181","author":"S Rossi","year":"2022","unstructured":"Rossi S, Jogeesvaran KH, Matu E, Khan H, Grande E, Meau-Petit V. Point-of-care ultrasound for neonatal central catheter positioning: impact on X-rays and line tip position accuracy. Eur J Pediatr. 2022;181(5):2097\u2013108. https:\/\/doi.org\/10.1007\/s00431-022-04412-z.","journal-title":"Eur J Pediatr"}],"container-title":["BMC Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12887-023-04444-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12887-023-04444-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12887-023-04444-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,9]],"date-time":"2023-12-09T06:04:01Z","timestamp":1702101841000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcpediatr.biomedcentral.com\/articles\/10.1186\/s12887-023-04444-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,9]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["4444"],"URL":"https:\/\/doi.org\/10.1186\/s12887-023-04444-w","relation":{},"ISSN":["1471-2431"],"issn-type":[{"value":"1471-2431","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,9]]},"assertion":[{"value":"24 July 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 November 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 December 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was conducted following the guidelines outlined in the Declaration of Helsinki. All methods were carried out in accordance with relevant guidelines and regulations. The study protocol was approved by the Institutional Review Board of Shengjing Hospital of China Medical University (approval number: 2021PS774K). The need for informed consent was waived by the Institutional Review Board of Shengjing Hospital of China Medical University because of the retrospective nature of the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"623"}}