{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T16:17:31Z","timestamp":1793636251549,"version":"4.5.1"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,2,13]],"date-time":"2024-02-13T00:00:00Z","timestamp":1707782400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,2,13]],"date-time":"2024-02-13T00:00:00Z","timestamp":1707782400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Pediatr"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Neonatal jaundice is a condition caused by elevated levels of bilirubin in the bloodstream. Laboratory determination of serum bilirubin concentration by total serum bilirubin (TSB) test is still considered as gold standard for clinical guidance and practice. In developed countries, diagnosis of neonatal jaundice is shifting towards point-of-care medical devices. BiliDx is a device developed to allow a fast, blood-based determination of bilirubin levels at the point of care. This study aimed to determine the accuracy of the BiliDx device relative to a standard laboratory total serum bilirubin to diagnose and monitor jaundice among neonates admitted at Muhimbili National Hospital (MNH).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Material and methodology<\/jats:title>\n                    <jats:p>This was a prospective hospital-based observational study conducted at the Neonatal Ward \u2013 MNH, Dar-es-Salaam, Tanzania from November 2022 to January 2023. A total of 180 neonates admitted at the neonatal ward with jaundice and whose parents consented were enrolled in the study. Blood samples were collected; 2\u00a0ml of venous blood into the vacutainer bottle for standard laboratory measurement of total serum bilirubin (TSB) and 25\u00b5L blood collected into a transfer pipette tube and applied to BiliDx. STATA version 15.1 was used for data analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Out of 180 neonates, 39.4% (71\/180) had birth weight between 1500 \u2212\u20092499.9\u00a0g, approximately 2\/3rd (120\/180) were preterm, 92\/180 (51.1%) were males and 100\/180 (55.6%) were undergoing phototherapy treatment the moment sample taken. The mean bilirubin concentration was 92 mmol\/l for BiliDx and 118 mmol\/l for standard laboratory TSB. The minimum and maximum values obtained with BiliDx were, 3.4 and 427.5 mmol\/l respectively, compared with 10.7 and 382.1 mmol\/l using standard laboratory TSB. A linear relationship and correlation coefficient of 0.8408 (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.000) between BiliDx and standard laboratory TSB was found. The regression analysis showed the presence of constant error [coefficient of BiliDx\/slope\u2009=\u20090.91, 95% CI (0.82\u20130.99),\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.000] and random error exclusively [coefficient of constant\/y-intercept\u2009=\u200948.52, 95%CI (37.70-59.34),\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.000]. The Bland\u2013Altman plot showed an acceptable mean difference of 39.1mmol\/l, limits of agreement of -48.3mmol\/l to 126.4mmol\/l, and 179 points (179\/180\u2009=\u200999.4%) lying inside the limits of agreement.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The results support the use of BiliDx for rapid and accurate testing of elevated levels of bilirubin in the bloodstream among neonates since 99.4% of the differences between BiliDx and standard laboratory TSB lie between the lines of agreement.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12887-024-04565-w","type":"journal-article","created":{"date-parts":[[2024,2,13]],"date-time":"2024-02-13T04:02:31Z","timestamp":1707796951000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Validity of BiliDx as a point-of-care bilirubin measurement device to diagnose and monitor neonatal jaundice at Muhimbili National Hospital, an observational study"],"prefix":"10.1186","volume":"24","author":[{"given":"Pascal","family":"Clemence","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Moshiro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karim","family":"Manji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,2,13]]},"reference":[{"key":"4565_CR1","doi-asserted-by":"crossref","unstructured":"Liu L, Oza S, Hogan D, Chu Y, Perin J, Zhu J et al. Global, regional and national causes of child mortality in 2000\u20132015 \u2013 implications for the Sustainable Development Goals. Lancet. 2016.","DOI":"10.1016\/S0140-6736(16)31593-8"},{"issue":"1","key":"4565_CR2","first-page":"25","volume":"1","author":"F Raimondi","year":"2012","unstructured":"Raimondi F, Ferrara T, Borrelli AC, Schettino D, Parrella C, Capasso L. Neonatal hyperbilirubinemia: a critical appraisal of current guidelines and evidence. J Pediatr Neonatal Individ Med. 2012;1(1):25\u201332.","journal-title":"J Pediatr Neonatal Individ Med"},{"key":"4565_CR3","unstructured":"Ministry of Health. The United Republic of Tanzania Ministry of Health, Community Development, Gender, Elderly and Children, National Guideline for Neonatal Care and Establishment of Neonatal Care Unit. 2019;(August):115\u20137."},{"issue":"1","key":"4565_CR4","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12887-018-1290-9","volume":"18","author":"R Rohsiswatmo","year":"2018","unstructured":"Rohsiswatmo R, Oswari H, Amandito R, Sjakti HA, Windiastuti E, Roeslani RD, et al. Agreement test of transcutaneous bilirubin and bilistick with serum bilirubin in preterm infants receiving phototherapy 11 Medical and Health sciences 1114 Paediatrics and Reproductive Medicine. BMC Pediatr. 2018;18(1):1\u20137.","journal-title":"BMC Pediatr"},{"issue":"51","key":"4565_CR5","doi-asserted-by":"publisher","first-page":"E10965","DOI":"10.1073\/pnas.1714020114","volume":"114","author":"PA Keahey","year":"2017","unstructured":"Keahey PA, Simeral ML, Schroder KJ, Bond MM, Mtenthaonnga PJ, Miros RH, et al. Point-of-care device to diagnose and monitor neonatal jaundice in low-resource settings. Proc Natl Acad Sci U S A. 2017;114(51):E10965\u201371.","journal-title":"Proc Natl Acad Sci U S A"},{"issue":"12","key":"4565_CR6","doi-asserted-by":"publisher","first-page":"722","DOI":"10.1007\/s00431-004-1533-7","volume":"163","author":"P Szabo","year":"2004","unstructured":"Szabo P, Wolf M, Bucher HU, Fauch\u00e8re JC, Haensse D, Arlettaz R. Detection of hyperbilirubinaemia in jaundiced full-term neonates by eye or by bilirubinometer? Eur J Pediatr. 2004;163(12):722\u20137.","journal-title":"Eur J Pediatr"},{"issue":"SUPPL 1","key":"4565_CR7","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1038\/pr.2013.208","volume":"74","author":"VK Bhutani","year":"2013","unstructured":"Bhutani VK, Zipursky A, Blencowe H, Khanna R, Sgro M, Ebbesen F, et al. Neonatal hyperbilirubinemia and rhesus disease of the newborn: incidence and impairment estimates for 2010 at regional and global levels. Pediatr Res. 2013;74(SUPPL 1):86\u2013100.","journal-title":"Pediatr Res"},{"issue":"12","key":"4565_CR8","doi-asserted-by":"publisher","first-page":"1909","DOI":"10.1111\/j.1651-2227.2009.01497.x","volume":"98","author":"S Wainer","year":"2009","unstructured":"Wainer S, Rabi Y, Parmar SM, Allegro D, Lyon M. Impact of skin tone on the performance of a transcutaneous jaundice meter. Acta Paediatr Int J Paediatr. 2009;98(12):1909\u201315.","journal-title":"Acta Paediatr Int J Paediatr"},{"key":"4565_CR9","unstructured":"NEST360. 2022, NEST360 Tanzania website, accessed 18 September 2022, https:\/\/nest360.org\/tanzania\/."},{"issue":"3","key":"4565_CR10","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1111\/j.1939-165X.2006.tb00131.x","volume":"35","author":"AL Jensen","year":"2006","unstructured":"Jensen AL, Kjelgaard-Hansen M. Method comparison in the clinical laboratory. Vet Clin Pathol. 2006;35(3):276\u201386.","journal-title":"Vet Clin Pathol"},{"key":"4565_CR11","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1016\/S2214-109X(21)00131-5","volume":"9","author":"A Shapiro","year":"2021","unstructured":"Shapiro A, Anderson J, Bond M, Schwarz R, Carns J, Mtenthaonga P, Kumwenda W, Johnston R, Miros R, Dube Q, Chiume M. A low-cost bilirubin measurement tool for neonatal jaundice monitoring at the point-of-care: a comparison of BiliDx with a standard laboratory bilirubinometer and transcutaneous bilirubinometer. The Lancet Global Health. 2021;9:23.","journal-title":"The Lancet Global Health"},{"issue":"9","key":"4565_CR12","doi-asserted-by":"publisher","first-page":"621","DOI":"10.1038\/jp.2011.5","volume":"31","author":"MJ Maisels","year":"2011","unstructured":"Maisels MJ, Engle WD, Wainer S, Jackson GL, McManus S, Artinian F. Transcutaneous bilirubin levels in an outpatient and office population. J Perinatol. 2011;31(9):621\u20134.","journal-title":"J Perinatol"},{"issue":"9","key":"4565_CR13","doi-asserted-by":"publisher","first-page":"659","DOI":"10.1016\/j.clinbiochem.2012.03.014","volume":"45","author":"C Romagnoli","year":"2012","unstructured":"Romagnoli C, Zecca E, Catenazzi P, Barone G, Zuppa AA. Transcutaneous bilirubin measurement: comparison of Respironics BiliCheck and JM-103 in a normal newborn population. Clin Biochem. 2012;45(9):659\u201362.","journal-title":"Clin Biochem"},{"key":"4565_CR14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1471-2431-9-70","volume":"9","author":"T Karen","year":"2009","unstructured":"Karen T, Bucher HU, Fauch\u00e8re JC. Comparison of a new transcutaneous bilirubinometer (Bilimed\u00ae) with serum bilirubin measurements in preterm and full-term infants. BMC Pediatr. 2009;9:1\u20137.","journal-title":"BMC Pediatr"},{"issue":"7","key":"4565_CR15","doi-asserted-by":"publisher","first-page":"486","DOI":"10.1038\/sj.jp.7211333","volume":"25","author":"WD Engle","year":"2005","unstructured":"Engle WD, Jackson GL, Stehel EK, Sendelbach DM, Manning MD. Evaluation of a transcutaneous Jaundice Meter following hospital discharge in term and near-term neonates. J Perinatol. 2005;25(7):486\u201390.","journal-title":"J Perinatol"},{"issue":"3","key":"4565_CR16","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1093\/pch\/16.3.141","volume":"16","author":"DM Campbell","year":"2011","unstructured":"Campbell DM, Danayan KC, McGovern V, Cheema S, Stade B, Sgro M. Transcutaneous bilirubin measurement at the time of hospital discharge in a multiethnic newborn population. Paediatr Child Health (Oxford). 2011;16(3):141\u20135.","journal-title":"Paediatr Child Health (Oxford)"},{"issue":"2","key":"4565_CR17","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1159\/000107351","volume":"93","author":"G Bertini","year":"2008","unstructured":"Bertini G, Pratesi S, Cosenza E, Dani C. Transcutaneous bilirubin measurement: evaluation of Bilitest\u2122. Neonatology. 2008;93(2):101\u20135.","journal-title":"Neonatology"},{"issue":"11","key":"4565_CR18","doi-asserted-by":"publisher","first-page":"1128","DOI":"10.1111\/j.1651-2227.2012.02797.x","volume":"101","author":"F Ebbesen","year":"2012","unstructured":"Ebbesen F, Vandborg PK, Trydal T. Comparison of the transcutaneous bilirubinometers BiliCheck and Minolta JM-103 in preterm neonates. Acta Paediatr Int J Paediatr. 2012;101(11):1128\u201333.","journal-title":"Acta Paediatr Int J Paediatr"},{"key":"4565_CR19","doi-asserted-by":"crossref","unstructured":"Raimondi F, Lama S, Landolfo F, Sellitto M, Borrelli AC, Maffucci R et al. Measuring transcutaneous bilirubin: a comparative analysis of three devices on a multiracial population. BMC Pediatr. 2012;12.","DOI":"10.1186\/1471-2431-12-70"},{"issue":"3","key":"4565_CR20","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1159\/000345425","volume":"103","author":"CD Coda Zabetta","year":"2013","unstructured":"Coda Zabetta CD, Iskander IF, Greco C, Bellarosa C, Demarini S, Tiribelli C, et al. Bilistick: a low-cost point-of-care system to measure total plasma bilirubin. Neonatology. 2013;103(3):177\u201381.","journal-title":"Neonatology"}],"container-title":["BMC Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12887-024-04565-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12887-024-04565-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12887-024-04565-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,17]],"date-time":"2024-02-17T10:08:44Z","timestamp":1708164524000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcpediatr.biomedcentral.com\/articles\/10.1186\/s12887-024-04565-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,13]]},"references-count":20,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["4565"],"URL":"https:\/\/doi.org\/10.1186\/s12887-024-04565-w","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-2917044\/v1","asserted-by":"object"}]},"ISSN":["1471-2431"],"issn-type":[{"value":"1471-2431","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,13]]},"assertion":[{"value":"10 May 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 January 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 February 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethical clearance and permission to conduct this study was sought from Directorate of Research, Training and Consultancy at Muhimbili National Hospital (Ref. No.: MNH\/TRCU\/Perm\/2022\/087). Mothers of respective neonates were informed about the study, its importance and the steps which were followed; those who understood and agreed to participate were requested to sign a written informed consent before enrollment. For the mothers who were not able to write, thumbprints were taken as proof of consent with an unbiased witness signing their testimony on the same consent form.Confidentiality was maintained during the whole period of study by use of a study identification number assigned to each participant. All neonates received the optimal standard of care offered at Muhimbili National Hospital (MNH) regardless of whether they accept to participate to the study or not, and all testing were done in accordance to the hospital unit\u2019s guidelines and regulations.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical Clearance and consideration"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent of publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"114"}}