{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T21:55:39Z","timestamp":1781646939839,"version":"3.54.5"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T00:00:00Z","timestamp":1775001600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,4,9]],"date-time":"2026-04-09T00:00:00Z","timestamp":1775692800000},"content-version":"vor","delay-in-days":8,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100009827","name":"Alexandria University","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100009827","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Pediatr"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Atrial Septal Defects (ASDs) are a common type of congenital heart defect (CHD) in children. Accurate pre-procedural assessment is crucial for successful transcatheter closure. This study aims to compare ASD size and surrounding rims measurements from transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) in pediatric patients undergoing transcatheter closure of ASDs, assess agreement between TTE and TEE measurements, and evaluate TTE\u2019s potential as a first-line imaging modality for ASD assessment.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This prospective cohort study was conducted on 50 pediatric patients with secundum ASD admitted for transcatheter device closure of ASD in Smouha University Hospital. Patients underwent TTE and TEE examinations before undergoing the procedure. ASD size and rim measurements (aortic, AV valve, SVC, IVC, posterior) were compared between modalities. Agreement was assessed using Bland-Altman analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      TTE measurements yielded significantly larger values of ASD size compared to TEE (22.27\u2009\u00b1\u20098.64\u00a0mm vs. 14.93\u2009\u00b1\u20095.11\u00a0mm;\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). Significant differences were also observed in rim measurements for the AV valve, Aortic, Posterior, and IVC rims (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.05), while SVC rim differences were not significant (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.212). Despite mean differences, a strong positive correlation was discovered between TTE and TEE measurements of ASD size (rs\u2009=\u20090.963,\n                      <jats:italic>p<\/jats:italic>\n                      \u2009&lt;\u20090.001). Bland-Altman analysis demonstrated good agreement with less than 5% of points falling outside the 95% limits of agreement. Procedural success was 100% with no residual shunts or complications at 24-hour follow-up.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>TTE was found to be reliable and cost-effective for evaluation of secundum ASDs, showing strong correlation with TEE. While TTE measurements were systematically larger, the agreement supports its use as a first-line modality for uncomplicated cases, while TEE remains valuable for detailed evaluation in complex scenarios.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12887-026-06695-9","type":"journal-article","created":{"date-parts":[[2026,4,1]],"date-time":"2026-04-01T05:08:54Z","timestamp":1775020134000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Two-dimensional transthoracic echocardiography versus two-dimensional trans esophageal echocardiography for assessment of moderate to large atrial septal defects and the device size in pediatric patients before transcatheter closure"],"prefix":"10.1186","volume":"26","author":[{"given":"Hani M.","family":"Adel","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed","family":"El-Nawawy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aly Abdel","family":"Mohsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3056-4398","authenticated-orcid":false,"given":"Omar","family":"Raafat","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,4,1]]},"reference":[{"issue":"4","key":"6695_CR1","doi-asserted-by":"publisher","first-page":"e0250006","DOI":"10.1371\/journal.pone.0250006","volume":"16","author":"YT Zikarg","year":"2021","unstructured":"Zikarg YT, Yirdaw CT, Aragie TG. Prevalence of congenital septal defects among congenital heart defect patients in East Africa: A systematic review and meta-analysis. PLoS ONE. 2021;16(4):e0250006. https:\/\/doi.org\/10.1371\/journal.pone.0250006.","journal-title":"PLoS ONE"},{"issue":"6","key":"6695_CR2","doi-asserted-by":"publisher","first-page":"837","DOI":"10.1161\/CIRCINTERVENTIONS.113.001254","volume":"7","author":"A-E Baruteau","year":"2014","unstructured":"Baruteau A-E, Petit J, Lambert V, Gouton M, Piot D, Brenot P, et al. Transcatheter Closure of Large Atrial Septal Defects. Circ Cardiovasc Interv. 2014;7(6):837\u201343. https:\/\/doi.org\/10.1161\/CIRCINTERVENTIONS.113.001254.","journal-title":"Circ Cardiovasc Interv"},{"issue":"11","key":"6695_CR3","doi-asserted-by":"publisher","first-page":"1196","DOI":"10.15537\/smj.2016.11.15617","volume":"37","author":"AS Azhar","year":"2016","unstructured":"Azhar AS. Safety and efficacy of transthoracic versus transesophageal echocardiography in transcatheter closure of atrial septal defects. Saudi Med J. 2016;37(11):1196\u2013205.","journal-title":"Saudi Med J"},{"issue":"Suppl 24","key":"6695_CR4","doi-asserted-by":"publisher","first-page":"S2899","DOI":"10.21037\/jtd.2018.07.126","volume":"10","author":"BS Rana","year":"2018","unstructured":"Rana BS. Echocardiography guidance of atrial septal defect closure. J Thorac Dis. 2018;10(Suppl 24):S2899\u2013908. https:\/\/doi.org\/10.21037\/jtd.2018.07.126.","journal-title":"J Thorac Dis"},{"issue":"5","key":"6695_CR5","doi-asserted-by":"publisher","first-page":"1247","DOI":"10.21037\/jtd.2017.04.45","volume":"9","author":"AE Baruteau","year":"2017","unstructured":"Baruteau AE, Hasco\u00ebt S, Fraisse A. Transthoracic echocardiography is a safe alternative for assessment and guidance of transcatheter closure of secundum atrial septal defect in children. J Thorac Dis. 2017;9(5):1247\u201356. https:\/\/doi.org\/10.21037\/jtd.2017.04.45.","journal-title":"J Thorac Dis"},{"issue":"7","key":"6695_CR6","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1093\/ehjci\/jeu316","volume":"16","author":"S Hascoet","year":"2015","unstructured":"Hascoet S, Hadeed K, Marchal P, Dulac Y, Alacoque X, Heitz F, et al. The relation between atrial septal defect shape, diameter, and area using three-dimensional transoesophageal echocardiography and balloon sizing during percutaneous closure in children. Eur Heart J Cardiovasc Imaging. 2015;16(7):747\u201355. https:\/\/doi.org\/10.1093\/ehjci\/jeu316.","journal-title":"Eur Heart J Cardiovasc Imaging"},{"issue":"2","key":"6695_CR7","first-page":"87","volume":"27","author":"AY Khalaf","year":"2023","unstructured":"Khalaf AY. The promising role of different imaging diagnostic modalities for percutaneous transcatheter device closure of secundum atrial septal defect in pediatrics in Sohag University Hospital. Sohag Med J. 2023;27(2):87\u201394.","journal-title":"Sohag Med J"},{"key":"6695_CR8","doi-asserted-by":"crossref","unstructured":"Cinteza E, Vasile CM, Busnatu S, Armat I, Spinu AD, Vatasescu R et al. (2024) Can Artificial Intelligence Revolutionize the Diagnosis and Management of the Atrial Septal Defect in Children. Diagnostics 14.","DOI":"10.3390\/diagnostics14020132"},{"issue":"5","key":"6695_CR9","doi-asserted-by":"publisher","first-page":"1007","DOI":"10.1213\/ANE.0b013e31826a79c1","volume":"115","author":"CF Royse","year":"2012","unstructured":"Royse CF, Canty DJ, Faris J, Haji DL, Veltman M, Royse A. Core review: physician-performed ultrasound: the time has come for routine use in acute care medicine. Anesth Analg. 2012;115(5):1007\u201328.","journal-title":"Anesth Analg"},{"issue":"4","key":"6695_CR10","doi-asserted-by":"publisher","first-page":"378","DOI":"10.1007\/s12519-018-0179-x","volume":"14","author":"WZ Xu","year":"2018","unstructured":"Xu WZ, Shou XY, Li JH, Yu JG, Zhang ZW, Yu J, et al. Non-fluoroscopic percutaneous transcatheter closure of atrial septal defects in children under transesophageal echocardiographic guidance. World J Pediatr. 2018;14(4):378\u201382. https:\/\/doi.org\/10.1007\/s12519-018-0179-x.","journal-title":"World J Pediatr"},{"issue":"9","key":"6695_CR11","first-page":"744","volume":"42","author":"X Pan","year":"2014","unstructured":"Pan X, Li S, Hu S, Ouyang W, Zhang F, Zhang D, et al. Feasibility of transcatheter closure of atrial septal defect under the guidance of transthoracic echocardiography. Zhonghua xin xue guan bing za zhi. 2014;42(9):744\u20137.","journal-title":"Zhonghua xin xue guan bing za zhi"},{"issue":"1","key":"6695_CR12","doi-asserted-by":"publisher","first-page":"G19","DOI":"10.1530\/ERP-19-0051","volume":"7","author":"A Zaidi","year":"2020","unstructured":"Zaidi A, Knight DS, Augustine DX, Harkness A, Oxborough D, Pearce K, et al. Echocardiographic Assessment of the Right Heart in Adults: A Practical Guideline from the British Society of Echocardiography. Echo Res Pract. 2020;7(1):G19\u201341. https:\/\/doi.org\/10.1530\/ERP-19-0051.","journal-title":"Echo Res Pract"},{"issue":"8","key":"6695_CR13","doi-asserted-by":"publisher","first-page":"795","DOI":"10.1016\/j.jcin.2018.01.262","volume":"11","author":"J Zakaria","year":"2018","unstructured":"Zakaria J, S\u00e9bastien H, C\u00e9line G, Fran\u00e7ois G, Lucia M, Claire D, et al. Long-Term Outcomes After Percutaneous Closure of Ostium Secundum Atrial Septal Defect in the Young. JACC Cardiovasc Interv. 2018;11(8):795\u2013804.","journal-title":"JACC Cardiovasc Interv"},{"issue":"8","key":"6695_CR14","doi-asserted-by":"publisher","first-page":"e31","DOI":"10.1016\/j.amjcard.2018.03.094","volume":"121","author":"E \u00d6zdemir","year":"2018","unstructured":"\u00d6zdemir E, K\u0131r\u0131\u015f T, Var\u0131\u015f E, Emren SV, Nazl\u0131 C, Toka\u00e7 M. In-Hospital Cost of Transcatheter Closure Versus Surgical Closure of Secundum Atrial Septal Defect. Am J Cardiol. 2018;121(8):e31\u20132. https:\/\/doi.org\/10.1016\/j.amjcard.2018.03.094.","journal-title":"Am J Cardiol"},{"issue":"6","key":"6695_CR15","doi-asserted-by":"publisher","first-page":"851","DOI":"10.4070\/kcj.2016.46.6.851","volume":"46","author":"T Saritas","year":"2016","unstructured":"Saritas T, Yucel IK, Demir IH, Demir F, Erdem A, Celebi A. Comparison of Transcatheter Atrial Septal Defect Closure in Children, Adolescents and adults: Differences, Challenges and Short-, Mid- and Long-Term Results. Korean Circ J. 2016;46(6):851\u201361.","journal-title":"Korean Circ J"},{"key":"6695_CR16","first-page":"231","volume":"71","author":"RI Rossi","year":"2008","unstructured":"Rossi RI, Cardoso CO, Machado PR, Francois LG, Horowitz ESK, Sarmento-Leite R. Transcatheter closure of atrial septal defect with Amplatzer device in children aged less than 10 years old: Immediate and late follow-up. Cathet Cardiovasc Intervent. 2008;71:231\u20136.","journal-title":"Cathet Cardiovasc Intervent"},{"issue":"9","key":"6695_CR17","doi-asserted-by":"publisher","first-page":"974","DOI":"10.1016\/j.jcin.2013.05.007","volume":"6","author":"S Bartakian","year":"2013","unstructured":"Bartakian S, El-Said HG, Printz B, Moore JW. Prospective Randomized Trial of Transthoracic Echocardiography Versus Transesophageal Echocardiography for Assessment and Guidance of Transcatheter Closure of Atrial Septal Defects in Children Using the Amplatzer Septal Occluder. JACC Cardiovasc Interv. 2013;6(9):974\u201380. https:\/\/doi.org\/10.1016\/j.jcin.2013.05.007.","journal-title":"JACC Cardiovasc Interv"},{"issue":"2","key":"6695_CR18","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1016\/j.euje.2005.12.014","volume":"7","author":"RM Lang","year":"2006","unstructured":"Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA, et al. Recommendations for chamber quantification. Eur J Echocardiogr. 2006;7(2):79\u2013108. https:\/\/doi.org\/10.1016\/j.euje.2005.12.014.","journal-title":"Eur J Echocardiogr"},{"issue":"16","key":"6695_CR19","doi-asserted-by":"publisher","first-page":"1309","DOI":"10.21037\/atm-21-3206","volume":"9","author":"B Deng","year":"2021","unstructured":"Deng B, Chen K, Huang T, Wei Y, Liu Y, Yang L, et al. Assessment of atrial septal defect using 2D or real-time 3D transesophageal echocardiography and outcomes following transcatheter closure. Ann Transl Med. 2021;9(16):1309.","journal-title":"Ann Transl Med"},{"issue":"2","key":"6695_CR20","doi-asserted-by":"publisher","first-page":"145","DOI":"10.5644\/ama2006-124.47","volume":"41","author":"S Mesihovi\u0107-Dinarevi\u0107","year":"2012","unstructured":"Mesihovi\u0107-Dinarevi\u0107 S, Begi\u0107 Z, Halimi\u0107 M, Kadi\u0107 A, Gojak R. Reliability of transthoracic and transesophageal echocardiography in predicting the size of atrial septal defect. Acta Med Acad. 2012;41(2):145\u201353. https:\/\/doi.org\/10.5644\/ama2006-124.47.","journal-title":"Acta Med Acad"},{"issue":"4","key":"6695_CR21","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1016\/j.echo.2010.12.011","volume":"24","author":"AM Johri","year":"2011","unstructured":"Johri AM, Witzke C, Solis J, Palacios IF, Inglessis I, Picard MH, et al. Real-Time Three-Dimensional Transesophageal Echocardiography in Patients with Secundum Atrial Septal Defects: Outcomes following Transcatheter Closure. J Am Soc Echocardiogr. 2011;24(4):431\u20137.","journal-title":"J Am Soc Echocardiogr"},{"key":"6695_CR22","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1111\/joic.12214","volume":"28","author":"XB Pan","year":"2015","unstructured":"Pan XB, Ou-Yang WB, Pang KJ, Zhang FW, Wang SZ, Liu Y, et al. Percutaneous closure of atrial septal defects under transthoracic echocardiography guidance without fluoroscopy or intubation in children. J Interv Cardiol. 2015;28:390\u20135.","journal-title":"J Interv Cardiol"},{"key":"6695_CR23","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1007\/s10554-011-9933-z","volume":"29","author":"A Erdem","year":"2013","unstructured":"Erdem A, Sar\u0131tas T, Zeybek C, Yucel IK, Erol N, Demir H, et al. Transthoracic echocardiographic guidance during transcatheter closure of atrial septal defects in children and adults. Int J Cardiovasc Imaging. 2013;29:53\u201361.","journal-title":"Int J Cardiovasc Imaging"},{"key":"6695_CR24","doi-asserted-by":"publisher","first-page":"1082663","DOI":"10.3389\/fcvm.2023.1082663","volume":"10","author":"Q Lan","year":"2023","unstructured":"Lan Q, Wu F, Ye X, Wang S, Zhong J. Intracardiac vs. transesophageal echocardiography for guiding transcatheter closure of interatrial communications: a systematic review and meta-analysis. Front Cardiovasc Med. 2023;10:1082663. https:\/\/doi.org\/10.3389\/fcvm.2023.1082663.","journal-title":"Front Cardiovasc Med"},{"issue":"6","key":"6695_CR25","doi-asserted-by":"publisher","first-page":"1722","DOI":"10.1161\/01.CIR.96.6.1722","volume":"96","author":"G Magni","year":"1997","unstructured":"Magni G, Hijazi ZM, Pandian NG, Delabays A, Sugeng L, Laskari C, et al. Two- and Three-Dimensional Transesophageal Echocardiography in Patient Selection and Assessment of Atrial Septal Defect Closure by the New DAS\u2013Angel Wings Device. Circulation. 1997;96(6):1722\u20138. https:\/\/doi.org\/10.1161\/01.CIR.96.6.1722.","journal-title":"Circulation"},{"key":"6695_CR26","unstructured":"Vesal A, Moradian M, Ghasemnezhad M, Tabib A, Rashidi F, Disney PJ et al. (2022) Comparison Between 2D Transthoracic Echocardiography, Transesophageal Echocardiography, and Balloon Sizing Methods for Device Size Selection in Pediatric Patients Undergoing Transcatheter Closure of Atrial Septal Defects. Iran Heart J 23(1)."}],"container-title":["BMC Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12887-026-06695-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12887-026-06695-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12887-026-06695-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T21:17:30Z","timestamp":1781644650000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12887-026-06695-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,4,1]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["6695"],"URL":"https:\/\/doi.org\/10.1186\/s12887-026-06695-9","relation":{},"ISSN":["1471-2431"],"issn-type":[{"value":"1471-2431","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,4,1]]},"assertion":[{"value":"24 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 February 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 April 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethical approval for this study was granted by the Alexandria University Ethical Committee (date: 10.05.2022, Serial No. 0201787). Written informed consent was obtained from the parents or legal guardians of all participating children prior to enrollment, in accordance with the Declaration of Helsinki and its 2020 amendments.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"288"}}