{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T01:57:44Z","timestamp":1780538264780,"version":"3.54.1"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,11,19]],"date-time":"2019-11-19T00:00:00Z","timestamp":1574121600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2019,11,19]],"date-time":"2019-11-19T00:00:00Z","timestamp":1574121600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Pulm Med"],"published-print":{"date-parts":[[2019,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Background<\/jats:title>\n<jats:p>Decades of clinical research into pulsed oxygen delivery has shown variable efficacy between users, and across a user\u2019s behaviours (sleep, rest, activity). Modern portable oxygen concentrators (POCs) have been shown as effective as other oxygen delivery devices in many circumstances. However, there are concerns that they are not effective during sleep when the breathing is shallow, and at very high respiratory rates as during physical exertion. It can be challenging to examine the determinants of POC efficacy clinically due to the heterogeneity of lung function within oxygen users, the diversity of user behaviour, and measurement issues. Representative bench testing may help identify key determinants of pulsed-oxygen device efficacy.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>Three contemporary devices were bench-evaluated across three simulated breathing behaviours: activity, rest, &amp; oronasal breathing during sleep. Emphasis was placed on breathing patterns representative of oxygen users.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>All three POCs performed well during simulated breathing during exertion and at rest. Differences in triggering ability were noted for the scenario of oronasal breathing during sleep.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>The results are supportive of contemporary POC triggering abilities. The differences shown in ultimate trigger sensitivity may have relevance to oronasal breathing during sleep or other challenging scenarios for pulsed oxygen delivery, such as dominant mouth breathing during exertion or unfavourable nasal geometry.<\/jats:p>\n<\/jats:sec>","DOI":"10.1186\/s12890-019-0980-x","type":"journal-article","created":{"date-parts":[[2019,11,19]],"date-time":"2019-11-19T06:03:03Z","timestamp":1574143383000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Contemporary portable oxygen concentrators and diverse breathing behaviours -- a bench comparison"],"prefix":"10.1186","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6503-6395","authenticated-orcid":false,"given":"Dion C.","family":"Martin","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,11,19]]},"reference":[{"key":"980_CR1","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1186\/1471-2466-11-9","volume":"11","author":"E Arnold","year":"2011","unstructured":"Arnold E, Bruton A, Donovan-Hall M, Fenwick A, Dibb B, Walker E. Ambulatory oxygen: why do COPD patients not use their portable systems as prescribed? A qualitative study. BMC Pulm Med. 2011;11:9.","journal-title":"A qualitative study. BMC Pulm Med."},{"issue":"3","key":"980_CR2","first-page":"279","volume":"11","author":"AS Melani","year":"2018","unstructured":"Melani AS, Sestini P, Rottoli P. Home oxygen therapy: re-thinking the role of devices. Expert review of clinical pharmacology. Taylor \\& Francis. 2018;11(3):279\u201389.","journal-title":"Taylor \\& Francis"},{"issue":"5","key":"980_CR3","first-page":"519","volume":"51","author":"T Petty","year":"2006","unstructured":"Petty T, McCoy R, Doherty D. Long Term Oxygen Therapy (LTOT): History, Scientific Foundations, and Emerging Technologies. Respir Care. 2006;51(5):519\u201325.","journal-title":"Respir Care."},{"issue":"2","key":"980_CR4","first-page":"231","volume":"3","author":"MRG Rous","year":"2008","unstructured":"Rous MRG. Long-term oxygen therapy: are we prescribing appropriately? International journal of chronic obstructive pulmonary disease. Dove Medical Press. 2008;3(2):231.","journal-title":"Dove Medical Press"},{"key":"980_CR5","unstructured":"American Association for Respiratory Care. Oxygen Therapy in the Home or Alternate Site Health Care Facility\u20142007 Revision & Update. Respir Care. 2007;52(8):1063\u20138."},{"issue":"10","key":"980_CR6","doi-asserted-by":"publisher","first-page":"1061","DOI":"10.1164\/rccm.200910-1638OC","volume":"181","author":"A Palwai","year":"2010","unstructured":"Palwai A, Skowronski M, Coreno A, Drummond C, McFadden ER. Critical comparisons of the clinical performance of oxygen-conserving devices. Am J Respir Crit Care Med. 2010;181(10):1061\u201371.","journal-title":"Am J Respir Crit Care Med."},{"issue":"10","key":"980_CR7","doi-asserted-by":"publisher","first-page":"1598","DOI":"10.4187\/respcare.02275","volume":"58","author":"CJ Leblanc","year":"2013","unstructured":"Leblanc CJ, Lavall\u00e9e LG, King JA, Taylor-Sussex RE, Woolnough A, McKim DA. A comparative study of 3 portable oxygen concentrators during a 6-minute walk test in patients with chronic lung disease. Respir Care. 2013;58(10):1598\u2013605.","journal-title":"Respir Care."},{"key":"980_CR8","first-page":"2559","volume":"12","author":"JZ Chen","year":"2017","unstructured":"Chen JZ, Katz IM, Pichelin M, Zhu K, Caillibotte G, Noga ML, et al. Comparison of pulsed versus continuous oxygen delivery using realistic adult nasal airway replicas. International journal of chronic obstructive pulmonary disease. Dove Press. 2017;12:2559.","journal-title":"Dove Press"},{"issue":"8","key":"980_CR9","doi-asserted-by":"publisher","first-page":"1199","DOI":"10.4187\/respcare.02878","volume":"59","author":"S Zhou","year":"2014","unstructured":"Zhou S, Chatburn RL. Effect of the anatomic reservoir on low-flow oxygen delivery via nasal cannula: constant flow versus pulse flow with portable oxygen concentrator. Respiratory care. Respiratory Care. 2014;59(8):1199\u2013209.","journal-title":"Respiratory care. Respiratory Care"},{"key":"980_CR10","unstructured":"Bliss PL, McCoy RW, Adams AB. A bench study comparison of demand oxygen delivery systems and continuous flow oxygen. Respir Care. Daedalus. 1999;44(8):925\u201331."},{"issue":"2","key":"980_CR11","first-page":"160","volume":"49","author":"PL Bliss","year":"2004","unstructured":"Bliss PL, McCoy RW, Adams AB. Characteristics of demand oxygen delivery systems: maximum output and setting recommendations. Respiratory care. American Association for Respiratory Care. 2004;49(2):160\u20135.","journal-title":"American Association for Respiratory Care"},{"key":"980_CR12","unstructured":"ISO 80601-2-67: Particular requirements for basic safety and essential performance of oxygen conserving equipment. 2014."},{"issue":"1","key":"980_CR13","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1183\/09031936.04.00072703","volume":"24","author":"DE O\u2019Donnell","year":"2004","unstructured":"O\u2019Donnell DE, Voduc N, Fitzpatrick M, Webb KA. Effect of salmeterol on the ventilatory response to exercise in chronic obstructive pulmonary disease. Eur Respir J. 2004;24(1):86\u201394.","journal-title":"Eur Respir J."},{"issue":"2","key":"980_CR14","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1183\/09031936.00063014","volume":"45","author":"CJ Jolley","year":"2015","unstructured":"Jolley CJ, Luo YM, Steier J, Rafferty GF, Polkey MI, Moxham J. Neural respiratory drive and breathlessness in COPD. European Respiratory Journal. Eur Respiratory Soc. 2015;45(2):355\u201364.","journal-title":"European Respiratory Journal. Eur Respiratory Soc"},{"issue":"1","key":"980_CR15","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1164\/ajrccm.159.1.9803037","volume":"159","author":"HF Becker","year":"1999","unstructured":"Becker HF, Piper AJ, Flynn WE, McNamara SG, Grunstein RR, Peter JH, et al. Breathing during sleep in patients with nocturnal desaturation. Am J Respir Crit Care Med. 1999;159(1):112\u20138.","journal-title":"Am J Respir Crit Care Med."},{"issue":"10","key":"980_CR16","doi-asserted-by":"publisher","first-page":"938","DOI":"10.1016\/j.rmed.2004.03.010","volume":"98","author":"C Fuhrman","year":"2004","unstructured":"Fuhrman C, Chouaid C, Herigault R, Housset B, Adnot S. Comparison of four demand oxygen delivery systems at rest and during exercise for chronic obstructive pulmonary disease. Respir Med. 2004;98(10):938\u201344.","journal-title":"Respir Med."},{"issue":"1","key":"980_CR17","first-page":"115","volume":"134","author":"K Gleeson","year":"1986","unstructured":"Gleeson K, Zwillich CW, Braier K, White DP. Breathing Route during Sleep. American Review of Respiratory Disease. Am Thoracic Soc. 1986;134(1):115\u201320.","journal-title":"Am Thoracic Soc"},{"key":"980_CR18","volume-title":"Principles and Practice of Sleep Medicine","author":"MHRTDW Kryger","year":"2010","unstructured":"Kryger MHRTDW. Principles and Practice of Sleep Medicine. 5th ed. Roth T, Dement WC, editor. Elsevier Saunders: Kryger MH; 2010.","edition":"5"},{"issue":"4","key":"980_CR19","first-page":"433","volume":"55","author":"RL Chatburn","year":"2010","unstructured":"Chatburn RL, Williams TJ. Performance comparison of 4 portable oxygen concentrators. Respir Care. 2010;55(4):433\u201342.","journal-title":"Respir Care."},{"issue":"6","key":"980_CR20","doi-asserted-by":"publisher","first-page":"2143","DOI":"10.1152\/jappl.2000.88.6.2143","volume":"88","author":"Y Yamada","year":"2000","unstructured":"Yamada Y, Du H-L. Analysis of the mechanisms of expiratory asynchrony in pressure support ventilation: a mathematical approach. Journal of Applied Physiology. Am Physiological Soc. 2000;88(6):2143\u201350.","journal-title":"Journal of Applied Physiology. Am Physiological Soc"},{"key":"980_CR21","doi-asserted-by":"crossref","unstructured":"Milic-Emili J, Zin W. Relationship between neuromuscular respiratory drive and ventilatory output. Comprehensive Physiology. Wiley Online Library. 2011:631\u201346.","DOI":"10.1002\/cphy.cp030335"},{"key":"980_CR22","volume-title":"Slutsky AS","author":"JJ Marini","year":"1998","unstructured":"Marini JJ. Slutsky AS. Marcel Dekker New York: Physiological basis of ventilatory support; 1998."},{"issue":"5 Pt 1","key":"980_CR23","doi-asserted-by":"publisher","first-page":"1471","DOI":"10.1164\/ajrccm.158.5.9802014","volume":"158","author":"S Parthasarathy","year":"1998","unstructured":"Parthasarathy S, Jubran A, Tobin MJ. Cycling of inspiratory and expiratory muscle groups with the ventilator in airflow limitation. Am J Respir Crit Care Med. 1998;158(5 Pt 1):1471\u20138.","journal-title":"Am J Respir Crit Care Med."},{"key":"980_CR24","unstructured":"Messenger B. Continuous vs. Pulsed Dose Point & counterpoint [Internet]. HME Business. 2009 [cited 2018 Sep 11]. Available from: https:\/\/hme-business.com\/Articles\/2009\/09\/01\/Continuous-Flow-vs-Pulse-Dose.aspx"},{"issue":"6","key":"980_CR25","first-page":"425","volume":"11","author":"F Magnet","year":"2017","unstructured":"Magnet F, Storre J, Windisch W. Home oxygen therapy: evidence versus reality. Expert review of respiratory medicine. Taylor & Francis. 2017;11(6):425\u201341.","journal-title":"Taylor & Francis"},{"issue":"3","key":"980_CR26","first-page":"679","volume":"117","author":"R Plywaczewski","year":"2000","unstructured":"Plywaczewski R, Sliwinski P, Nowinski A, Kaminski D, Zieli\u2019nski J. Incidence of Nocturnal Desaturation While Breathing Oxygen in COPD Patients Undergoing Long-term Oxygen Therapy*. Chest. American College of Chest Physicians. 2000;117(3):679\u201383.","journal-title":"Chest. American College of Chest Physicians"},{"key":"980_CR27","doi-asserted-by":"crossref","unstructured":"Heinzer RC, S\u00e9ri\u00e8s F. Normal physiology of the upper and lower airways. Principles and Practice of Sleep Medicine (Fifth Edition). Elsevier. 2011:259\u201368.","DOI":"10.1016\/B978-1-4160-6645-3.00023-2"},{"issue":"2","key":"980_CR28","first-page":"663","volume":"559","author":"FJ O\u2019Donoghue","year":"2004","unstructured":"O\u2019Donoghue FJ, Catcheside PG, Eckert DJ, RD ME. Changes in respiration in NREM sleep in hypercapnic chronic obstructive pulmonary disease. The Journal of Physiology. Wiley Online Library. 2004;559(2):663\u201373.","journal-title":"The Journal of Physiology. Wiley Online Library"},{"issue":"1","key":"980_CR29","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1378\/chest.116.1.22","volume":"116","author":"A Cuvelier","year":"1999","unstructured":"Cuvelier A, Muir JF, Czernichow P, Vavasseur E, Portier F, Benhamou D, et al. Nocturnal efficiency and tolerance of a demand oxygen delivery system in COPD patients with nocturnal hypoxemia. Chest. 1999;116(1):22\u20139.","journal-title":"Chest."},{"issue":"8","key":"980_CR30","first-page":"1100","volume":"54","author":"PJ Dunne","year":"2009","unstructured":"Dunne PJ. The clinical impact of new long-term oxygen therapy technology. Respiratory Care. Respiratory Care. 2009;54(8):1100\u201311.","journal-title":"Respiratory Care. Respiratory Care"},{"issue":"8","key":"980_CR31","first-page":"879","volume":"47","author":"RW McCoy","year":"2002","unstructured":"McCoy RW. New technologies for lighter portable oxygen systems. Respiratory care. 2002;47(8):879.","journal-title":"Respiratory care."},{"issue":"3","key":"980_CR32","doi-asserted-by":"publisher","first-page":"382","DOI":"10.4187\/respcare.03470","volume":"60","author":"AM Y\u00e1\u00f1ez","year":"2015","unstructured":"Y\u00e1\u00f1ez AM, Prat JP, \u00c1lvarez-Sala JL, Calle M, Lobato SD, Gonzalez JLG, et al. Oxygenation with a single portable pulse-dose oxygen-conserving device and combined stationary and portable oxygen delivery devices in subjects with COPD. Respiratory care. Respiratory Care. 2015;60(3):382\u20137.","journal-title":"Respiratory care. Respiratory Care"},{"issue":"2","key":"980_CR33","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1378\/chest.119.2.442","volume":"119","author":"L Hern\u00e1ndez","year":"2001","unstructured":"Hern\u00e1ndez L, Ballester E, Farr\u00e9 R, Badia JR, Lobelo R, Navajas D, et al. Performance of nasal prongs in sleep studies: spectrum of flow-related events. Chest. Elsevier. 2001;119(2):442\u201350.","journal-title":"Chest. Elsevier"},{"issue":"6","key":"980_CR34","doi-asserted-by":"publisher","first-page":"651","DOI":"10.1080\/000164802320396349","volume":"122","author":"B Oeverland","year":"2002","unstructured":"Oeverland B, Akre H, Skatvedt O. Oral breathing in patients with sleep-related breathing disorders. Acta Otolaryngol. 2002;122(6):651\u20134.","journal-title":"Acta Otolaryngol."},{"issue":"1","key":"980_CR35","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1183\/09031936.04.00004303","volume":"24","author":"MR Madronio","year":"2004","unstructured":"Madronio MR, Di Somma E, Stavrinou R, Kirkness JP, Goldfinch E, Wheatley JR, et al. Older individuals have increased oro-nasal breathing during sleep. Eur Respir J. 2004;24(1):71\u20137.","journal-title":"Eur Respir J."},{"key":"980_CR36","unstructured":"James DS, Lambert WE, Mermier CM, Stidley CA, Chick TW, Samet JM. Oronasal distribution of ventilation at different ages. Archives of Environmental Health: An International Journal. Taylor & Francis; 1997;52(2):118\u2013123."},{"issue":"6","key":"980_CR37","doi-asserted-by":"publisher","first-page":"1037","DOI":"10.1378\/chest.92.6.1037","volume":"92","author":"TS Chadha","year":"1987","unstructured":"Chadha TS, Birch S, Sackner MA. Oronasal distribution of ventilation during exercise in normal subjects and patients with asthma and rhinitis. Chest. Elsevier. 1987;92(6):1037\u201341.","journal-title":"Chest. Elsevier"},{"issue":"1","key":"980_CR38","first-page":"1","volume":"5","author":"A Leiberman","year":"1991","unstructured":"Leiberman A, Ohki M, Cole P. The open mouth and oronasal breathing. American Journal of Rhinology. OceanSide Publications. Inc. 1991;5(1):1\u20135.","journal-title":"Inc"},{"key":"980_CR39","unstructured":"Moore CP, Finlay W, Martin AR. Investigating Intersubject Variability In Pulsed Oxygen Delivery Using Adult Nasal Airway Replicas. American Journal of Respiratory and Critical Care Medicine. 2015;A5811."},{"issue":"1","key":"980_CR40","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1136\/thx.2004.031211","volume":"60","author":"IM Balfour-Lynn","year":"2005","unstructured":"Balfour-Lynn IM, Primhak RA, Shaw BNJ. Home oxygen for children: who, how and when? Thorax. 2005;60(1):76\u201381.","journal-title":"Thorax."}],"container-title":["BMC Pulmonary Medicine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12890-019-0980-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12890-019-0980-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12890-019-0980-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,11,18]],"date-time":"2020-11-18T03:58:25Z","timestamp":1605671905000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcpulmmed.biomedcentral.com\/articles\/10.1186\/s12890-019-0980-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,19]]},"references-count":40,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["980"],"URL":"https:\/\/doi.org\/10.1186\/s12890-019-0980-x","relation":{},"ISSN":["1471-2466"],"issn-type":[{"value":"1471-2466","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11,19]]},"assertion":[{"value":"29 January 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 October 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 November 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable - All data are bench-derived (no plant, animal, or human experimentation), free of consent or ethical issues.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable - All data employed were generated from bench measurements, free of consent or ethical issues.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Dion Martin is a full-time employee of ResMed Ltd., Sydney, Australia.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"217"}}