{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,8]],"date-time":"2026-05-08T07:01:57Z","timestamp":1778223717736,"version":"3.51.4"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,5,29]],"date-time":"2020-05-29T00:00:00Z","timestamp":1590710400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,5,29]],"date-time":"2020-05-29T00:00:00Z","timestamp":1590710400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Pulm Med"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>Usual clinical practice for arterial blood gas analysis (BGA) in conscious patients involves a one-time arterial puncture to be performed after a resting period of 20\u201330\u2009min. The aim of this study was to evaluate the use of transcutaneous BGA for estimating this gold standard arterial BGA.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Spontaneously breathing Asian adults (healthy volunteers and respiratory patients) were enrolled (<jats:italic>n<\/jats:italic>\u2009=\u2009295). Transcutaneous PO<jats:sub>2<\/jats:sub>(PtcO<jats:sub>2<\/jats:sub>) and PCO<jats:sub>2<\/jats:sub>(PtcCO<jats:sub>2<\/jats:sub>) were monitored using a transcutaneous monitor (TCM4, Radiometer Medical AsP, Denmark) with sensors placed on the chest, forearm, earlobe or forehead. Transcutaneous BGA at 1-min intervals was compared with arterial BGA at 30\u2009min. Reasonable steps to find severe hypercapnia with PaCO<jats:sub>2<\/jats:sub>\u2009&gt;\u200950\u2009mmHg were evaluated.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Sensors on the chest and forearm were equally preferred and used because of small biases (<jats:italic>n<\/jats:italic>\u2009=\u2009272). The average PCO<jats:sub>2<\/jats:sub>bias was close to 0\u2009mmHg at 4\u2009min, and was almost constant (4\u20135\u2009mmHg) with PtcCO<jats:sub>2<\/jats:sub>being higher than PaCO<jats:sub>2<\/jats:sub>at \u22658\u2009min. The limit of agreement for PCO<jats:sub>2<\/jats:sub>narrowed over time: \u00b1 13.6\u2009mmHg at 4\u2009min, \u00b1 7.5\u2009mmHg at 12\u201313\u2009min, and\u2009\u00b1\u20096.3\u2009mmHg at 30\u2009min. The limit of agreement for PO<jats:sub>2<\/jats:sub>also narrowed over time (\u00b1 23.1\u2009mmHg at 30\u2009min). Subgroup analyses showed that the PaCO<jats:sub>2<\/jats:sub>and PaO<jats:sub>2<\/jats:sub>levels, gender, and younger age significantly affected the biases. All hypercapnia subjects with PaCO<jats:sub>2<\/jats:sub>\u2009&gt;\u200950\u2009mmHg (<jats:italic>n<\/jats:italic>\u2009=\u200913) showed PtcCO<jats:sub>2<\/jats:sub>\u2009\u2265\u200950\u2009mmHg for until 12\u2009min.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Although PtcCO<jats:sub>2<\/jats:sub>is useful, it cannot completely replace PaCO<jats:sub>2<\/jats:sub>because PCO<jats:sub>2<\/jats:sub>occasionally showed large bias. On the other hand, the prediction of PaO<jats:sub>2<\/jats:sub>using PtcO<jats:sub>2<\/jats:sub>was unrealistic in Asian adults. PtcCO<jats:sub>2<\/jats:sub>\u2009\u2265\u200950\u2009mmHg for until 12\u2009min can be used as a screening tool for severe hypercapnia with PaCO<jats:sub>2<\/jats:sub>\u2009&gt;\u200950\u2009mmHg.<\/jats:p><\/jats:sec>","DOI":"10.1186\/s12890-020-01184-w","type":"journal-article","created":{"date-parts":[[2020,5,29]],"date-time":"2020-05-29T11:02:58Z","timestamp":1590750178000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Evaluation of time courses of agreement between minutely obtained transcutaneous blood gas data and the gold standard arterial data from spontaneously breathing Asian adults, and various subgroup analyses"],"prefix":"10.1186","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3115-9842","authenticated-orcid":false,"given":"Akira","family":"Umeda","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masahiro","family":"Ishizaka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masamichi","family":"Tasaki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tateki","family":"Yamane","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Taiji","family":"Watanabe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasushi","family":"Inoue","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Taichi","family":"Mochizuki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasumasa","family":"Okada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sarah","family":"Kesler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,5,29]]},"reference":[{"key":"1184_CR1","doi-asserted-by":"crossref","unstructured":"Huch R, Huch A, Albani M, Gabriel M, Schulte FJ, Wolf H, et al. Transcutaneous PO2 monitoring in routine management of infants and children with cardiorespiratory problems. Pediatrics. 1976;57(5):681\u201390.","DOI":"10.1542\/peds.57.5.681"},{"issue":"8019","key":"1184_CR2","doi-asserted-by":"crossref","first-page":"982","DOI":"10.1016\/S0140-6736(77)92282-6","volume":"1","author":"A Huch","year":"1977","unstructured":"Huch A, Seiler D, Meinzer K, Huch R, Galster H, L\u00fcbbers DW. Transcutaneous PCO2 measurement with a miniaturised electrode. Lancet. 1977;1(8019):982\u20133.","journal-title":"Lancet."},{"key":"1184_CR3","doi-asserted-by":"crossref","unstructured":"Lucey JF. Clinical uses of transcutaneous oxygen monitoring. Adv Pediatr. 1981;28:27\u201356.","DOI":"10.1016\/S0065-3101(22)00634-X"},{"issue":"8","key":"1184_CR4","doi-asserted-by":"crossref","first-page":"1471","DOI":"10.1093\/clinchem\/29.8.1471","volume":"29","author":"P D Wimberley","year":"1983","unstructured":"Wimberley PD, Pedersen KG, Thode J, Fogh-Andersen N, S\u00f8rensen AM, Siggaard-Andersen O. Transcutaneous and capillary pCO2 and pO2 measurements in healthy adults. Clin Chem. 1983;29(8):1471\u20133.","journal-title":"Clinical Chemistry"},{"key":"1184_CR5","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1186\/1471-2431-5-30","volume":"5","author":"M R\u00fcdiger","year":"2005","unstructured":"R\u00fcdiger M, T\u00f6pfer K, Hammer H, Schmalisch G, Wauer RR. A survey of transcutaneous blood gas monitoring among European neonatal intensive care units. BMC Pediatr. 2005;5:30.","journal-title":"BMC Pediatr"},{"issue":"9","key":"1184_CR6","doi-asserted-by":"crossref","first-page":"1872","DOI":"10.1016\/j.ajem.2012.03.033","volume":"30","author":"Samuel Delerme","year":"2012","unstructured":"Delerme S, Montout V, Goulet H, Arhan A, Le Sach\u00e9 F, Devilliers C, et al. Concordance between transcutaneous and arterial measurements of carbon dioxide in an ED. Am J Emerg Med. 2012;30(9):1872\u20136.","journal-title":"The American Journal of Emergency Medicine"},{"issue":"1","key":"1184_CR7","doi-asserted-by":"crossref","first-page":"98","DOI":"10.4187\/respcare.03917","volume":"61","author":"S. Stieglitz","year":"2015","unstructured":"Stieglitz S, Matthes S, Priegnitz C, Hagmeyer L, Randerath W. Comparison of transcutaneous and capillary measurement of PCO2 in hypercapnic subjects. Respir Care. 2016;61(1):98\u2013105.","journal-title":"Respiratory Care"},{"issue":"4","key":"1184_CR8","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1007\/s00540-006-0422-9","volume":"20","author":"Tomoki Nishiyama","year":"2006","unstructured":"Nishiyama T, Nakamura S, Yamashita K. Effects of the electrode temperature of a new monitor, TCM4, on the measurement of transcutaneous oxygen and carbon dioxide tension. J Anesth. 2006;20(4):331\u20134.","journal-title":"Journal of Anesthesia"},{"issue":"11","key":"1184_CR9","doi-asserted-by":"crossref","first-page":"1955","DOI":"10.4187\/respcare.02011","volume":"57","author":"Ruben D Restrepo","year":"2012","unstructured":"Restrepo RD, Hirst KR, Wittnebel L, Wettstein R. AARC clinical practice guideline: transcutaneous monitoring of carbon dioxide and oxygen: 2012. Respir Care. 2012;57(11):1955\u201362.","journal-title":"Respiratory Care"},{"issue":"5","key":"1184_CR10","doi-asserted-by":"crossref","first-page":"202","DOI":"10.12968\/jowc.2010.19.5.48048","volume":"19","author":"C. Ruangsetakit","year":"2010","unstructured":"Ruangsetakit C, Chinsakchai K, Mahawongkajit P, Wongwanit C, Mutirangura P. Transcutaneous oxygen tension: a useful predictor of ulcer healing in critical limb ischaemia. J Wound Care. 2010;19(5):202\u20136.","journal-title":"Journal of Wound Care"},{"issue":"3","key":"1184_CR11","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1111\/j.1440-1843.2008.01442.x","volume":"14","author":"Satoshi FUKE","year":"2009","unstructured":"Fuke S, Miyamoto K, Ohira H, Ohira M, Odajima N, Nishimura M. Evaluation of transcutaneous CO2 responses following acute changes in PaCO2 in healthy subjects. Respirology. 2009;14(3):436\u201342.","journal-title":"Respirology"},{"issue":"5","key":"1184_CR12","doi-asserted-by":"crossref","first-page":"1744","DOI":"10.1378\/chest.127.5.1744","volume":"127","author":"Antoine Cuvelier","year":"2005","unstructured":"Cuvelier A, Grigoriu B, Morano LC, Muir JF. Limitation of transcutaneous carbon dioxide measurements for assessing long-term mechanical ventilation. Chest. 2005;127(5):1744\u20138.","journal-title":"Chest"},{"issue":"6","key":"1184_CR13","doi-asserted-by":"crossref","first-page":"1810","DOI":"10.1378\/chest.07-1173","volume":"132","author":"Jan H. Storre","year":"2007","unstructured":"Storre JH, Steurer B, Kabitz HJ, Dreher M, Windisch W. Transcutaneous PCO2 monitoring during initiation of noninvasive ventilation. Chest. 2007;132(6):1810\u20136.","journal-title":"Chest"},{"issue":"5","key":"1184_CR14","doi-asserted-by":"crossref","first-page":"1211","DOI":"10.1378\/chest.99.5.1211","volume":"99","author":"Steven Kesten","year":"1991","unstructured":"Kesten S, Chapman KR, Rebuck AS. Response characteristics of a dual transcutaneous oxygen\/carbon dioxide monitoring system. Chest. 1991;99(5):1211\u20135.","journal-title":"Chest"},{"key":"1184_CR15","unstructured":"Dejours P. Oxygen and carbon dioxide exchanges by diffusion. In: Principles of comparative respiratory physiology. 2nd ed. Amsterdam: Elsevier\/North-Holland Biomedical Press; 1981. p. 63\u201374."},{"issue":"12","key":"1184_CR16","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1017\/S0265021506001116","volume":"23","author":"T. Nishiyama","year":"2006","unstructured":"Nishiyama T, Nakamura S, Yamashita K. Comparison of the transcutaneous oxygen and carbon dioxide tension in different electrode locations during general anaesthesia. Eur J Anaesthesiol. 2006;23(12):1049\u201354.","journal-title":"European Journal of Anaesthesiology"},{"key":"1184_CR17","unstructured":"Malley WJ. Arterial blood gases. In: Clinical blood gases: Assessment and Intervention. 2nd ed. St. Louis: Elsevier Saunders; 2005. p. 3\u201334."},{"key":"1184_CR18","unstructured":"American Association for Respiratory Care. AARC clinical practice guideline. Sampling for arterial blood gas analysis. Respir Care. 1992;37(8):913\u20137."},{"issue":"1","key":"1184_CR19","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1164\/ajrccm.152.1.7599814","volume":"152","author":"S A Sasse","year":"1995","unstructured":"Sasse SA, Jaffe MB, Chen PA, Voelker KG, Mahutte CK. Arterial oxygenation time after an FIO2 increase in mechanically ventilated patients. Am J Respir Crit Care Med. 1995;152(1):148\u201352.","journal-title":"American Journal of Respiratory and Critical Care Medicine"},{"key":"1184_CR20","doi-asserted-by":"crossref","unstructured":"Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307\u201310.","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"1184_CR21","unstructured":"Malley WJ. Blood gas electrodes and quality assurance. In: Clinical blood gases: Assessment and Intervention. 2nd ed. St. Louis: Elsevier Saunders; 2005. p. 82\u2013113."},{"key":"1184_CR22","volume-title":"Designing clinical research","author":"SB Hulley","year":"2013","unstructured":"Hulley SB, Cummings SR, Browner WS, Grady DG, Newman TB. Designing clinical research. 4th ed. Philadelphia: Lippincott Williams & Wilkins, a Wolters Kluwer business; 2013.","edition":"4"},{"issue":"9","key":"1184_CR23","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1016\/j.ajem.2007.12.001","volume":"26","author":"Akira Umeda","year":"2008","unstructured":"Umeda A, Kawasaki K, Abe T, Watanabe M, Ishizaka A, Okada Y. Hyperventilation and finger exercise increase venous-arterial PCO2 and pH differences. Am J Emerg Med. 2008;26(9):975\u201380.","journal-title":"The American Journal of Emergency Medicine"},{"key":"1184_CR24","doi-asserted-by":"crossref","unstructured":"Aliwalas LL, Noble L, Nesbitt K, Fallah S, Shah V, Shah PS. Agreement of carbon dioxide levels measured by arterial, transcutaneous and end tidal methods in preterm infants < or = 28 weeks gestation. J Perinatol. 2005;25(1):26\u20139.","DOI":"10.1038\/sj.jp.7211202"},{"issue":"1","key":"1184_CR25","first-page":"55","volume":"85","author":"Joseph D. Tobias","year":"1997","unstructured":"Tobias JD, Meyer DJ. Noninvasive monitoring of carbon dioxide during respiratory failure in toddlers and infants: end-tidal versus transcutaneous carbon dioxide. Anesth Analg. 1997;85(1):55\u20138.","journal-title":"Anesthesia & Analgesia"},{"key":"1184_CR26","doi-asserted-by":"crossref","unstructured":"Oshibuchi M, Cho S, Hara T, Tomiyasu S, Makita T, Sumikawa K. A comparative evaluation of transcutaneous and end-tidal measurements of CO2 in thoracic anesthesia. Anesth Analg. 2003;97(3):776\u20139.","DOI":"10.1213\/01.ANE.0000074793.12070.1E"},{"issue":"6","key":"1184_CR27","doi-asserted-by":"crossref","first-page":"F523","DOI":"10.1136\/adc.2004.064717","volume":"90","author":"D G Tingay","year":"2005","unstructured":"Tingay DG, Stewart MJ, Morley CJ. Monitoring of end tidal carbon dioxide and transcutaneous carbon dioxide during neonatal transport. Arch Dis Child Fetal Neonatal Ed. 2005;90(6):F523\u20136.","journal-title":"Archives of Disease in Childhood - Fetal and Neonatal Edition"},{"key":"1184_CR28","doi-asserted-by":"crossref","unstructured":"Hirabayashi M, Fujiwara C, Ohtani N, Kagawa S, Kamide M. Transcutaneous PCO2 monitors are more accurate than end-tidal PCO2 monitors. J Anesth. 2009;23(2):198\u2013202.","DOI":"10.1007\/s00540-008-0734-z"},{"key":"1184_CR29","unstructured":"Severinghaus JW, Bradley AF, Stafford MJ. Transcutaneous PCO2 electrode design with internal silver heat path. Birth Defects Orig Artic Ser. 1979;15(4):265\u201370."},{"key":"1184_CR30","doi-asserted-by":"crossref","unstructured":"Severinghaus JW, Stafford M, Thunstrom AM. Estimation of skin metabolism and blood flow with tcPO2 and tcPO2 electrodes by cuff occlusion of the circulation. Acta Anaesthesiol Scand Suppl. 1978;68:9\u201315.","DOI":"10.1111\/j.1399-6576.1978.tb01386.x"},{"key":"1184_CR31","unstructured":"Malley WJ. Noninvasive blood gas monitoring. In: Clinical blood gases: Assessment and Intervention. 2nd ed. St. Louis: Elsevier Saunders; 2005. p. 387\u2013418."},{"issue":"10","key":"1184_CR32","doi-asserted-by":"crossref","first-page":"2203","DOI":"10.1097\/01.CCM.0000181734.26070.26","volume":"33","author":"Karim Bendjelid","year":"2005","unstructured":"Bendjelid K, Sch\u00fctz N, Stotz M, Gerard I, Suter PM, Romand JA. Transcutaneous PCO2 monitoring in critically ill adults: clinical evaluation of a new sensor. Crit Care Med. 2005;33(10):2203\u20136.","journal-title":"Critical Care Medicine"},{"issue":"20","key":"1184_CR33","doi-asserted-by":"crossref","first-page":"6254","DOI":"10.1073\/pnas.1506523112","volume":"112","author":"Shathiyah Kulandavelu","year":"2015","unstructured":"Kulandavelu S, Balkan W, Hare JM. Regulation of oxygen delivery to the body via hypoxic vasodilation. Proc Natl Acad Sci U S A. 2015;112(20):6254\u20135.","journal-title":"Proceedings of the National Academy of Sciences"},{"issue":"4","key":"1184_CR34","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1164\/ajrccm.159.4.9612071","volume":"159","author":"JULIO SANDOVAL","year":"1999","unstructured":"Sandoval J, Alvarado P, Mart\u00ednez-Guerra ML, G\u00f3mez A, Palomar A, Meza S, et al. Effect of body position changes on pulmonary gas exchange in Eisenmenger's syndrome. Am J Respir Crit Care Med. 1999;159(4 Pt 1):1070\u20133.","journal-title":"American Journal of Respiratory and Critical Care Medicine"},{"issue":"2","key":"1184_CR35","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1159\/000056314","volume":"69","author":"Jon A. Hardie","year":"2002","unstructured":"Hardie JA, M\u00f8rkve O, Ellingsen I. Effect of body position on arterial oxygen tension in the elderly. Respiration. 2002;69(2):123\u20138.","journal-title":"Respiration"}],"container-title":["BMC Pulmonary Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12890-020-01184-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12890-020-01184-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12890-020-01184-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T17:38:41Z","timestamp":1696181921000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcpulmmed.biomedcentral.com\/articles\/10.1186\/s12890-020-01184-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5,29]]},"references-count":35,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["1184"],"URL":"https:\/\/doi.org\/10.1186\/s12890-020-01184-w","relation":{},"ISSN":["1471-2466"],"issn-type":[{"value":"1471-2466","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,5,29]]},"assertion":[{"value":"7 March 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 May 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 May 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The project was approved by the Ethics Committee of the International University of Health and Welfare (IUHW, approval number 13-B-109). All subjects provided written consent before participating in this study.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors have no potential conflicts of interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"151"}}