{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,13]],"date-time":"2026-02-13T04:38:41Z","timestamp":1770957521269,"version":"3.50.1"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,4,15]],"date-time":"2020-04-15T00:00:00Z","timestamp":1586908800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2020,4,15]],"date-time":"2020-04-15T00:00:00Z","timestamp":1586908800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Pulm Med"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Background<\/jats:title>\n<jats:p>The most prevalent complication of percutaneous lung biopsy is pneumothorax (PNX). A routine immediate post-procedure CT scan (ICT) to spot PNX is done in many centers. However, the diagnostic yield of this practice has not been studied broadly. We sought to evaluate whether an ICT could replace the routine follow-up chest X-ray (CXR) in detecting procedure related PNX.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>We examined case-records of 453 patients who underwent lung biopsy at our medical center<jats:bold>.<\/jats:bold> We analyzed findings from CXR performed 2-h after biopsy and from CT images at the site of biopsy acquired immediately after the procedure (ICT). Multivariate analysis was used to identify the risk factors for PNX, and we examined the concordance between ICT and CXR-2-h post-procedure.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>A total of 87 patients (19%) were diagnosed with PNX on CXR-2-h post-procedure. ICT detected 80.5% of diagnosed PNX (<jats:italic>p<\/jats:italic>\u2009&lt;\u2009\u00a00.01). However, ICT demonstrated a negative predictive value of only 94%, meaning 17 patients (6%) with a negative ICT did eventually develop PNX seen on CXR. Furthermore, bleeding surrounding the puncture area spotted on ICT negatively predicted the development of PNX (OR\u2009=\u20090.4 95% CI; 0.2\u20130.7).<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>We conclude that a CT scan performed immediately after percutaneous lung biopsy cannot replace the routine follow-up CXR in predicting iatrogenic PNX. Bleeding in the needle\u2019s tract may lower the risk for procedure-related PNX.<\/jats:p>\n<\/jats:sec>","DOI":"10.1186\/s12890-020-1128-8","type":"journal-article","created":{"date-parts":[[2020,4,15]],"date-time":"2020-04-15T11:03:17Z","timestamp":1586948597000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["The yield of immediate post lung biopsy CT in predicting iatrogenic pneumothorax"],"prefix":"10.1186","volume":"20","author":[{"given":"Rafael Y.","family":"Brzezinski","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ifat","family":"Vigiser","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Irina","family":"Fomin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lilach","family":"Israeli","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shani","family":"Shenhar-Tsarfaty","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9364-6887","authenticated-orcid":false,"given":"Amir","family":"Bar-Shai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,4,15]]},"reference":[{"key":"1128_CR1","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1186\/s12890-018-0713-6","volume":"18","author":"C-J Deng","year":"2018","unstructured":"Deng C-J, Dai F-Q, Qian K, Tan Q-Y, Wang R-W, Deng B, et al. Clinical updates of approaches for biopsy of pulmonary lesions based on systematic review. BMC Pulm Med. 2018;18:146.","journal-title":"BMC Pulm Med"},{"key":"1128_CR2","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1007\/s13244-017-0561-6","volume":"8","author":"M Anzidei","year":"2017","unstructured":"Anzidei M, Porfiri A, Andrani F, Di Martino M, Saba L, Catalano C, et al. Imaging-guided chest biopsies: techniques and clinical results. Insights Imaging. 2017;8:419\u201328.","journal-title":"Insights Imaging"},{"key":"1128_CR3","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1007\/s00330-016-4357-8","volume":"27","author":"WJ Heerink","year":"2017","unstructured":"Heerink WJ, de Bock GH, de Jonge GJ, Groen HJM, Vliegenthart R, Oudkerk M. Complication rates of CT-guided transthoracic lung biopsy: meta-analysis. Eur Radiol. 2017;27:138\u201348.","journal-title":"Eur Radiol"},{"issue":"Suppl 1","key":"1128_CR4","first-page":"S99","volume":"6","author":"T Boskovic","year":"2014","unstructured":"Boskovic T, Stanic J, Pena-Karan S, Zarogoulidis P, Drevelegas K, Katsikogiannis N, et al. Pneumothorax after transthoracic needle biopsy of lung lesions under CT guidance. J Thorac Dis. 2014;6(Suppl 1):S99\u2013107.","journal-title":"J Thorac Dis"},{"key":"1128_CR5","doi-asserted-by":"publisher","first-page":"474","DOI":"10.1111\/j.1754-9485.2011.02283.x","volume":"55","author":"M Nakamura","year":"2011","unstructured":"Nakamura M, Yoshizako T, Koyama S, Kitagaki H. Risk factors influencing chest tube placement among patients with pneumothorax because of CT-guided needle biopsy of the lung. J Med Imaging Radiat Oncol. 2011;55:474\u20138.","journal-title":"J Med Imaging Radiat Oncol"},{"key":"1128_CR6","doi-asserted-by":"publisher","first-page":"e0178078","DOI":"10.1371\/journal.pone.0178078","volume":"12","author":"D Lendeckel","year":"2017","unstructured":"Lendeckel D, Kromrey M-L, Ittermann T, Sch\u00e4fer S, Mensel B, K\u00fchn J-P. Pulmonary emphysema is a predictor of pneumothorax after CT-guided transthoracic pulmonary biopsies of pulmonary nodules. PLoS One. 2017;12:e0178078.","journal-title":"PLoS One"},{"key":"1128_CR7","doi-asserted-by":"publisher","first-page":"1049","DOI":"10.2214\/ajr.146.5.1049","volume":"146","author":"LM Perlmutt","year":"1986","unstructured":"Perlmutt LM, Braun SD, Newman GE, Oke EJ, Dunnick NR. Timing of chest film follow-up after transthoracic needle aspiration. Am J Roentgenol. 1986;146:1049\u201350.","journal-title":"Am J Roentgenol"},{"key":"1128_CR8","doi-asserted-by":"publisher","first-page":"1516","DOI":"10.1378\/chest.126.5.1516","volume":"126","author":"CM Choi","year":"2004","unstructured":"Choi CM, Um SW, Yoo CG, Young WK, Sung KH, Shim YS, et al. Incidence and risk factors of delayed pneumothorax after transthoracic needle biopsy of the lung. Chest. 2004;126:1516\u201321.","journal-title":"Chest."},{"key":"1128_CR9","doi-asserted-by":"publisher","first-page":"1415","DOI":"10.1007\/s00270-017-1632-2","volume":"40","author":"S Taleb","year":"2017","unstructured":"Taleb S, Jalaeian H, Frank N, Golzarian J, D\u2019Souza D. Is a routine chest X-ray necessary in every patient after percutaneous CT-guided lung biopsy? A retrospective review of 278 cases. Cardiovasc Intervent Radiol. 2017;40:1415\u201320.","journal-title":"Cardiovasc Intervent Radiol"},{"key":"1128_CR10","doi-asserted-by":"publisher","first-page":"920","DOI":"10.1136\/thorax.58.11.920","volume":"58","author":"A Manhire","year":"2003","unstructured":"Manhire A, Charig M, Clelland C, Gleeson F, Miller R, Moss H, et al. Guidelines for radiologically guided lung biopsy. Thorax. 2003;58:920\u201336.","journal-title":"Thorax."},{"key":"1128_CR11","doi-asserted-by":"publisher","first-page":"087","DOI":"10.1055\/s-0031-1273943","volume":"28","author":"K Birchard","year":"2011","unstructured":"Birchard K. Transthoracic Needle Biopsy. Semin Intervent Radiol. 2011;28:087\u201397.","journal-title":"Semin Intervent Radiol"},{"key":"1128_CR12","doi-asserted-by":"publisher","first-page":"1328","DOI":"10.1007\/s00330-017-5058-7","volume":"28","author":"WH Lim","year":"2018","unstructured":"Lim WH, Park CM, Yoon SH, Lim H, Hwang EJ, Lee JH, et al. Time-dependent analysis of incidence, risk factors and clinical significance of pneumothorax after percutaneous lung biopsy. Eur Radiol. 2018;28:1328\u201337.","journal-title":"Eur Radiol"},{"key":"1128_CR13","first-page":"1","volume":"2019","author":"S Wang","year":"2019","unstructured":"Wang S, Tu J, Chen W. Development and validation of a prediction pneumothorax model in CT-guided transthoracic needle biopsy for solitary pulmonary nodule. Biomed Res Int. 2019;2019:1\u20137.","journal-title":"Biomed Res Int"}],"container-title":["BMC Pulmonary Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12890-020-1128-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12890-020-1128-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12890-020-1128-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,14]],"date-time":"2021-04-14T23:21:27Z","timestamp":1618442487000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcpulmmed.biomedcentral.com\/articles\/10.1186\/s12890-020-1128-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,15]]},"references-count":13,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["1128"],"URL":"https:\/\/doi.org\/10.1186\/s12890-020-1128-8","relation":{},"ISSN":["1471-2466"],"issn-type":[{"value":"1471-2466","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,15]]},"assertion":[{"value":"10 October 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 March 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 April 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study was approved by the Tel Aviv Medical Center Institutional Review Board (IRB), conformed to the principles outlined in the Declaration of Helsinki and Informed consent was waived due to the retrospective nature of the study.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"91"}}