{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T19:33:06Z","timestamp":1780601586875,"version":"3.54.1"},"reference-count":9,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,8,17]],"date-time":"2022-08-17T00:00:00Z","timestamp":1660694400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,8,17]],"date-time":"2022-08-17T00:00:00Z","timestamp":1660694400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Pulm Med"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Computed tomography-guided hook wire localization (CT-GHWL) was used to localize the small pulmonary nodules before video-assisted thoracic surgery (VATS). Its associated complications included hook wire dislodgement, pulmonary hemorrhage, and pneumothorax. This is the first report of a patient with a hook wire sliding into the subglottic area after CT-GHWL.\n<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Case presentation<\/jats:title>\n                <jats:p>A 27-year-old female had productive cough for 8 days. A high-resolution CT scan showed a 12 mm part-solid nodule in the number 8 segment of the left lung. Prior to VATS, she received CT-GHWL to localize the nodule. During VATS, the hook wire unexpectedly slid away. A chest computed tomography was immediately performed and the sagittal reconstructed images showed the needle at the subglottic area. Finally, the needle was extracted by biopsy forceps under bronchoscope evaluation. The patient was eventually recovered and discharged.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Dislodge of the hook wire into the subglottic area is an extremely rare but serious complication following CT-GHWL. Attention should be paid to securing the needle on the lung surface during VATS.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12890-022-02065-0","type":"journal-article","created":{"date-parts":[[2022,8,17]],"date-time":"2022-08-17T13:03:33Z","timestamp":1660741413000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["A hook wire dislodged into the subglottic area as a rare complication following computed tomography-guided hook wire localization: a case report"],"prefix":"10.1186","volume":"22","author":[{"given":"Haiyin","family":"Fan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Changying","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0940-1041","authenticated-orcid":false,"given":"Bin","family":"Zou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,8,17]]},"reference":[{"issue":"3","key":"2065_CR1","first-page":"266","volume":"30","author":"JH Pedersen","year":"2016","unstructured":"Pedersen JH, Saghir Z, Wille MM, Thomsen LH, Skov BG, Ashraf H. Ground-glass opacity lung nodules in the era of lung cancer CT screening: radiology, pathology, and clinical management. Oncol Williston Park. 2016;30(3):266\u201374.","journal-title":"Oncol Williston Park"},{"issue":"4","key":"2065_CR2","doi-asserted-by":"publisher","first-page":"1467","DOI":"10.1378\/chest.122.4.1467","volume":"122","author":"J Burdine","year":"2002","unstructured":"Burdine J, Joyce LD, Plunkett MB, Inampudi S, Kaye MG, Dunn DH. Feasibility and value of video-assisted thoracoscopic surgery wedge excision of small pulmonary nodules in patients with malignancy. Chest. 2002;122(4):1467\u201370. https:\/\/doi.org\/10.1378\/chest.122.4.1467.","journal-title":"Chest"},{"issue":"2","key":"2065_CR3","doi-asserted-by":"publisher","first-page":"279","DOI":"10.2214\/ajr.161.2.8333361","volume":"161","author":"RM Shah","year":"1993","unstructured":"Shah RM, Spirn PW, Salazar AM, Steiner RM, Cohn HE, Solit RW, et al. Localization of peripheral pulmonary nodules for thoracoscopic excision: value of CT-guided wire placement. AJR Am J Roentgenol. 1993;161(2):279\u201383. https:\/\/doi.org\/10.2214\/ajr.161.2.8333361.","journal-title":"AJR Am J Roentgenol"},{"issue":"4","key":"2065_CR4","doi-asserted-by":"publisher","first-page":"1203","DOI":"10.1016\/j.athoracsur.2013.05.026","volume":"96","author":"J Ichinose","year":"2013","unstructured":"Ichinose J, Kohno T, Fujimori S, Harano T, Suzuki S. Efficacy and complications of computed tomography-guided hook wire localization. Ann Thorac Surg. 2013;96(4):1203\u20138. https:\/\/doi.org\/10.1016\/j.athoracsur.2013.05.026.","journal-title":"Ann Thorac Surg"},{"issue":"2","key":"2065_CR5","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1016\/j.chest.2016.09.017","volume":"151","author":"CH Park","year":"2017","unstructured":"Park CH, Han K, Hur J, Lee SM, Lee JW, Hwang SH, et al. Comparative effectiveness and safety of preoperative lung localization for pulmonary nodules: a systematic review and meta-analysis. Chest. 2017;151(2):316\u201328. https:\/\/doi.org\/10.1016\/j.chest.2016.09.017.","journal-title":"Chest"},{"issue":"6","key":"2065_CR6","doi-asserted-by":"publisher","first-page":"1334","DOI":"10.2214\/ajr.16.16272","volume":"207","author":"M Kleedehn","year":"2016","unstructured":"Kleedehn M, Kim DH, Lee FT, Lubner MG, Robbins JB, Ziemlewicz TJ, et al. Preoperative pulmonary nodule localization: a comparison of methylene blue and hookwire techniques. AJR Am J Roentgenol. 2016;207(6):1334\u20139. https:\/\/doi.org\/10.2214\/ajr.16.16272.","journal-title":"AJR Am J Roentgenol"},{"issue":"1","key":"2065_CR7","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1186\/s13019-020-01105-2","volume":"15","author":"X Song","year":"2020","unstructured":"Song X, Li J, Wang D. A hook wire sliding into pulmonary artery and being extracted under DSA: a case report about a rare complication associated with lung nodule localization. J Cardiothorac Surg. 2020;15(1):63. https:\/\/doi.org\/10.1186\/s13019-020-01105-2.","journal-title":"J Cardiothorac Surg"},{"issue":"2","key":"2065_CR8","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1007\/s11748-019-01142-2","volume":"68","author":"H Torigoe","year":"2020","unstructured":"Torigoe H, Hirano Y, Ando Y, Washio K. Migration of a hookwire used as a video-assisted thoracoscopic surgery marker into the splenic artery. Gen Thorac Cardiovasc Surg. 2020;68(2):194\u20138. https:\/\/doi.org\/10.1007\/s11748-019-01142-2.","journal-title":"Gen Thorac Cardiovasc Surg"},{"issue":"12","key":"2065_CR9","doi-asserted-by":"publisher","first-page":"5237","DOI":"10.21037\/jtd.2019.11.74","volume":"11","author":"M Patella","year":"2019","unstructured":"Patella M, Bartolucci DA, Mongelli F, Cartolari R, Minerva EM, Inderbitzi R, et al. Spiral wire localization of lung nodules: procedure effectiveness and oncological usefulness. J Thorac Dis. 2019;11(12):5237\u201346. https:\/\/doi.org\/10.21037\/jtd.2019.11.74.","journal-title":"J Thorac Dis"}],"container-title":["BMC Pulmonary Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12890-022-02065-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12890-022-02065-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12890-022-02065-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,17]],"date-time":"2022-08-17T13:03:43Z","timestamp":1660741423000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcpulmmed.biomedcentral.com\/articles\/10.1186\/s12890-022-02065-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,17]]},"references-count":9,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["2065"],"URL":"https:\/\/doi.org\/10.1186\/s12890-022-02065-0","relation":{},"ISSN":["1471-2466"],"issn-type":[{"value":"1471-2466","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,17]]},"assertion":[{"value":"21 April 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 July 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 August 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This case is based on retrospective study, so there is no need for ethical approval.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Informed written consent was obtained from the patient for publication of this report and any accompanying images.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"317"}}