{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,14]],"date-time":"2026-04-14T15:37:23Z","timestamp":1776181043608,"version":"3.50.1"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,3,20]],"date-time":"2024-03-20T00:00:00Z","timestamp":1710892800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,3,20]],"date-time":"2024-03-20T00:00:00Z","timestamp":1710892800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Key R&D Program of Zhejiang","award":["No. 2022C03086"],"award-info":[{"award-number":["No. 2022C03086"]}]},{"name":"Key R&D Program of Zhejiang","award":["No. 2022C03086"],"award-info":[{"award-number":["No. 2022C03086"]}]},{"name":"Key R&D Program of Zhejiang","award":["No. 2022C03086"],"award-info":[{"award-number":["No. 2022C03086"]}]},{"name":"Key R&D Program of Zhejiang","award":["No. 2022C03086"],"award-info":[{"award-number":["No. 2022C03086"]}]},{"name":"Key R&D Program of Zhejiang","award":["No. 2022C03086"],"award-info":[{"award-number":["No. 2022C03086"]}]},{"name":"Key R&D Program of Zhejiang","award":["No. 2022C03086"],"award-info":[{"award-number":["No. 2022C03086"]}]},{"name":"Key R&D Program of Zhejiang","award":["No. 2022C03086"],"award-info":[{"award-number":["No. 2022C03086"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Pulm Med"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Objective<\/jats:title>\n                <jats:p>Transbronchial biopsy is a safe manner with fewer complications than percutaneous transthoracic needle biopsy; however, the current diagnostic yield is still necessitating further improvement. We aimed to evaluate the diagnostic yield of using virtual bronchoscopic navigation (VBN) and cone-beam CT (CBCT) for transbronchial biopsy and to investigate the factors that affected the diagnostic sensitivity.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>We retrospectively investigated 255 patients who underwent VBN-CBCT-guided transbronchial biopsy at our two centers from May 2021 to April 2022. A total of 228 patients with final diagnoses were studied. Patient characteristics including lesion size, lesion location, presence of bronchus sign, lesion type and imaging tool used were collected and analyzed. Diagnostic yield was reported overall and in groups using different imaging tools.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The median size of lesion was 21\u00a0mm (range of 15.5\u201329\u00a0mm) with 46.1% less than 2\u00a0cm in diameter. Bronchus sign was present in 87.7% of the patients. The overall diagnostic yield was 82.1%, and sensitivity for malignancy was 66.3%. Patients with lesion\u2009&gt;\u20092\u00a0cm or with bronchus sign were shown to have a significantly higher diagnostic yield. Four patients had bleeding and no pneumothorax occurred.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Guided bronchoscopy with VBN and CBCT was an effective diagnostic method and was associated with a high diagnostic yield in a safe manner. In addition, the multivariant analysis suggested that lesion size and presence of bronchus sign could be a predictive factor for successful bronchoscopic diagnosis.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12890-024-02930-0","type":"journal-article","created":{"date-parts":[[2024,3,20]],"date-time":"2024-03-20T17:01:29Z","timestamp":1710954089000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Virtual bronchoscopic navigation with intraoperative cone-beam CT for the diagnosis of peripheral pulmonary nodules"],"prefix":"10.1186","volume":"24","author":[{"given":"Jisong","family":"Zhang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Enguo","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shan","family":"Xu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Li","family":"Xu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Huihui","family":"Hu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Liangliang","family":"Dong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kejing","family":"Ying","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,3,20]]},"reference":[{"key":"2930_CR1","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1055\/s-0038-1676775","volume":"39","author":"U Chaddha","year":"2018","unstructured":"Chaddha U, Kurman JS, Mahajan A, Hogarth DK. Lung nodule management: an interventional pulmonology perspective. Semin Respir Crit Care Med. 2018;39:661\u20136.","journal-title":"Semin Respir Crit Care Med"},{"key":"2930_CR2","doi-asserted-by":"publisher","first-page":"395","DOI":"10.1056\/NEJMoa1102873","volume":"365","author":"T Research","year":"2011","unstructured":"National Lung Screening Trial, Research T, Aberle DR, Adams AM, Berg CD, Black WC, Clapp JD, Fagerstrom RM, Gareen IF, Gatsonis C, Marcus PM, Sicks JD. Reduced lung-cancer mortality with low-dose computed tomographic screening. N Engl J Med. 2011;365:395\u2013409.","journal-title":"N Engl J Med"},{"key":"2930_CR3","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1055\/s-0034-1395499","volume":"35","author":"P Chenna","year":"2014","unstructured":"Chenna P, Chen AC. Radial probe endobronchial ultrasound and novel navigation biopsy techniques. Semin Respir Crit Care Med. 2014;35:645\u201354.","journal-title":"Semin Respir Crit Care Med"},{"key":"2930_CR4","doi-asserted-by":"crossref","unstructured":"Wahidi MM, Govert JA, Goudar RK, Gould MK, McCrory DC, American College of Chest P. Evidence for the treatment of patients with pulmonary nodules: when is it lung cancer? ACCP evidence-based clinical practice guidelines (2nd edition). Chest. 2007;132:94S\u2013107S.","DOI":"10.1378\/chest.07-1352"},{"key":"2930_CR5","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1007\/s00408-016-9866-3","volume":"194","author":"M Sachdeva","year":"2016","unstructured":"Sachdeva M, Ronaghi R, Mills PK, Peterson MW. Complications and yield of computed tomography-guided transthoracic core needle biopsy of lung nodules at a high-volume academic center in an endemic coccidioidomycosis area. Lung. 2016;194:379\u201385.","journal-title":"Lung"},{"key":"2930_CR6","doi-asserted-by":"publisher","first-page":"7683","DOI":"10.21037\/jtd-2020-abpd-003","volume":"12","author":"A Wagh","year":"2020","unstructured":"Wagh A, Ho E, Murgu S, Hogarth DK. Improving diagnostic yield of navigational bronchoscopy for peripheral pulmonary lesions: a review of advancing technology. J Thorac Disease. 2020;12:7683\u201390.","journal-title":"J Thorac Disease"},{"key":"2930_CR7","doi-asserted-by":"publisher","first-page":"672","DOI":"10.1007\/s11748-019-01241-0","volume":"68","author":"T Ishiwata","year":"2020","unstructured":"Ishiwata T, Gregor A, Inage T, Yasufuku K. Bronchoscopic navigation and tissue diagnosis. Gen Thorac Cardiovasc Surg. 2020;68:672\u20138.","journal-title":"Gen Thorac Cardiovasc Surg"},{"key":"2930_CR8","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1016\/j.jtho.2021.12.008","volume":"17","author":"EE Folch","year":"2022","unstructured":"Folch EE, Bowling MR, Pritchett MA, Murgu SD, Nead MA, Flandes J, Krimsky WS, Mahajan AK, LeMense GP, Murillo BA, Bansal S, Lau K, Gildea TR, Christensen M, Arenberg DA, Singh J, Bhadra K, Hogarth DK, Towe CW, Lamprecht B, Bezzi M, Mattingley JS, Hood KL, Lin H, Wolvers JJ, Khandhar SJ. NAVIGATE 24-month results: electromagnetic navigation bronchoscopy for pulmonary lesions at 37 centers in Europe and the United States. J Thorac Oncol. 2022;17:519\u201331.","journal-title":"J Thorac Oncol"},{"key":"2930_CR9","doi-asserted-by":"publisher","first-page":"1753","DOI":"10.1016\/j.chest.2020.05.534","volume":"158","author":"EE Folch","year":"2020","unstructured":"Folch EE, Labarca G, Ospina-Delgado D, Kheir F, Majid A, Khandhar SJ, Mehta HJ, Jantz MA, Fernandez-Bussy S. Sensitivity and safety of electromagnetic navigation bronchoscopy for lung cancer diagnosis. Chest. 2020;158:1753\u201369.","journal-title":"Chest"},{"key":"2930_CR10","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.ejrad.2006.02.001","volume":"59","author":"N Tomiyama","year":"2006","unstructured":"Tomiyama N, Yasuhara Y, Nakajima Y, Adachi S, Arai Y, Kusumoto M, Eguchi K, Kuriyama K, Sakai F, Noguchi M, Murata K, Murayama S, Mochizuki T, Mori K, Yamada K. CT-guided needle biopsy of lung lesions: a survey of severe complication based on 9783 biopsies in Japan. Eur J Radiol. 2006;59:60\u20134.","journal-title":"Eur J Radiol"},{"key":"2930_CR11","doi-asserted-by":"crossref","unstructured":"Wiener RS, Schwartz LM, Woloshin S, Welch HG. Population-based risk for complications after transthoracic needle lung biopsy of a pulmonary nodule: an analysis of discharge records. Ann Intern Med. 2011;155.","DOI":"10.7326\/0003-4819-155-3-201108020-00003"},{"key":"2930_CR12","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1097\/LBR.0b013e3182198f24","volume":"18","author":"M Oshige","year":"2011","unstructured":"Oshige M, Shirakawa T, Nakamura M, Mineshita M, Kurimoto N, Miyazawa T, Becker HD. Clinical application of virtual bronchoscopic navigation system for peripheral lung lesions. J Bronchol Interventional Pulmonol. 2011;18:196\u2013202.","journal-title":"J Bronchol Interventional Pulmonol"},{"key":"2930_CR13","doi-asserted-by":"publisher","first-page":"430","DOI":"10.1159\/000367900","volume":"88","author":"F Asano","year":"2014","unstructured":"Asano F, Eberhardt R, Herth FJF. Virtual bronchoscopic navigation for peripheral pulmonary lesions. Respiration. 2014;88:430\u201340.","journal-title":"Respiration"},{"key":"2930_CR14","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.ejrad.2009.11.023","volume":"79","author":"S Iwano","year":"2011","unstructured":"Iwano S, Imaizumi K, Okada T, Hasegawa Y, Naganawa S. Virtual bronchoscopy-guided transbronchial biopsy for aiding the diagnosis of peripheral lung cancer. Eur J Radiol. 2011;79:155\u20139.","journal-title":"Eur J Radiol"},{"key":"2930_CR15","doi-asserted-by":"publisher","first-page":"1864","DOI":"10.1111\/1759-7714.13995","volume":"12","author":"X Zheng","year":"2021","unstructured":"Zheng X, Xie F, Li Y, Chen J, Jiang Y, Sun J. Ultrathin bronchoscope combined with virtual bronchoscopic navigation and endobronchial ultrasound for the diagnosis of peripheral pulmonary lesions with or without fluoroscopy: a randomized trial. Thorac Cancer. 2021;12:1864\u201372.","journal-title":"Thorac Cancer"},{"key":"2930_CR16","doi-asserted-by":"publisher","first-page":"964","DOI":"10.2214\/AJR.12.10156","volume":"201","author":"SH Choi","year":"2013","unstructured":"Choi SH, Chae EJ, Kim J-E, Kim EY, Oh SY, Hwang HJ, Lee HJ. Percutaneous CT-guided aspiration and core biopsy of pulmonary nodules smaller than 1\u00a0cm: analysis of outcomes of 305 procedures from a tertiary referral center. Am J Roentgenol. 2013;201:964\u201370.","journal-title":"Am J Roentgenol"},{"key":"2930_CR17","doi-asserted-by":"crossref","unstructured":"Wang Y, Jiang F, Tan X, Tian P. CT-guided percutaneous transthoracic needle biopsy for paramediastinal and nonparamediastinal lung lesions. Medicine. 2016;95.","DOI":"10.1097\/MD.0000000000004460"},{"key":"2930_CR18","doi-asserted-by":"publisher","first-page":"6950","DOI":"10.21037\/jtd.2018.11.21","volume":"10","author":"RF Casal","year":"2018","unstructured":"Casal RF, Sarkiss M, Jones AK, Stewart J, Tam A, Grosu HB, Ost DE, Jimenez CA, Eapen GA. Cone beam computed tomography-guided thin\/ultrathin bronchoscopy for diagnosis of peripheral lung nodules: a prospective pilot study. J Thorac Disease. 2018;10:6950\u20139.","journal-title":"J Thorac Disease"},{"key":"2930_CR19","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1159\/000500228","volume":"98","author":"EAA Ali","year":"2019","unstructured":"Ali EAA, Takizawa H, Kawakita N, Sawada T, Tsuboi M, Toba H, Takashima M, Matsumoto D, Yoshida M, Kawakami Y, Kondo K, Khairy El-Badrawy M, Tangoku A. Transbronchial biopsy using an ultrathin bronchoscope guided by cone-beam computed tomography and virtual bronchoscopic navigation in the diagnosis of pulmonary nodules. Respiration. 2019;98:321\u20138.","journal-title":"Respiration"},{"key":"2930_CR20","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1164\/rccm.201211-2104OC","volume":"188","author":"F Asano","year":"2013","unstructured":"Asano F, Shinagawa N, Ishida T, Shindoh J, Anzai M, Tsuzuku A, Oizumi S, Morita S. Virtual bronchoscopic navigation combined with ultrathin bronchoscopy. A randomized clinical trial. Am J Respir Crit Care Med. 2013;188:327\u201333.","journal-title":"Am J Respir Crit Care Med"},{"key":"2930_CR21","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1164\/rccm.201502-0205OC","volume":"192","author":"M Oki","year":"2015","unstructured":"Oki M, Saka H, Ando M, Asano F, Kurimoto N, Morita K, Kitagawa C, Kogure Y, Miyazawa T. Ultrathin bronchoscopy with multimodal devices for peripheral pulmonary lesions. A Randomized Trial. Am J Respir Crit Care Med. 2015;192:468\u201376.","journal-title":"Am J Respir Crit Care Med"},{"key":"2930_CR22","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1186\/s12890-017-0531-2","volume":"17","author":"F Asano","year":"2017","unstructured":"Asano F, Ishida T, Shinagawa N, Sukoh N, Anzai M, Kanazawa K, Tsuzuku A, Morita S. Virtual bronchoscopic navigation without X-ray fluoroscopy to diagnose peripheral pulmonary lesions: a randomized trial. BMC Pulm Med. 2017;17:184.","journal-title":"BMC Pulm Med"},{"key":"2930_CR23","doi-asserted-by":"publisher","first-page":"7416","DOI":"10.21037\/jtd-20-2382","volume":"12","author":"R Setser","year":"2020","unstructured":"Setser R, Chintalapani G, Bhadra K, Casal RF. Cone beam CT imaging for bronchoscopy: a technical review. J Thorac Dis. 2020;12:7416\u201328.","journal-title":"J Thorac Dis"},{"key":"2930_CR24","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1097\/LBR.0000000000000697","volume":"28","author":"RLJ Verhoeven","year":"2021","unstructured":"Verhoeven RLJ, Futterer JJ, Hoefsloot W, van der Heijden E, Cone-Beam CT. Image guidance with and without electromagnetic navigation bronchoscopy for biopsy of peripheral pulmonary lesions. J Bronchol Interv Pulmonol. 2021;28:60\u20139.","journal-title":"J Bronchol Interv Pulmonol"},{"key":"2930_CR25","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1097\/LBR.0000000000000536","volume":"25","author":"MA Pritchett","year":"2018","unstructured":"Pritchett MA, Schampaert S, de Groot JAH, Schirmer CC, van der Bom I. Cone-beam CT with augmented fluoroscopy combined with electromagnetic navigation bronchoscopy for biopsy of pulmonary nodules. J Bronchol Interv Pulmonol. 2018;25:274\u201382.","journal-title":"J Bronchol Interv Pulmonol"},{"key":"2930_CR26","doi-asserted-by":"publisher","first-page":"1275","DOI":"10.1378\/chest.14-1425","volume":"147","author":"A Chen","year":"2015","unstructured":"Chen A, Pastis N, Furukawa B, Silvestri GA. The effect of respiratory motion on pulmonary nodule location during electromagnetic navigation bronchoscopy. Chest. 2015;147:1275\u201381.","journal-title":"Chest"},{"key":"2930_CR27","doi-asserted-by":"publisher","first-page":"E416","DOI":"10.21037\/jtd.2017.04.48","volume":"9","author":"CP Hsieh","year":"2017","unstructured":"Hsieh CP, Hsieh MJ, Fang HY, Chao YK. Imaging-guided thoracoscopic resection of a ground-glass opacity lesion in a hybrid operating room equipped with a robotic C-arm CT system. J Thorac Dis. 2017;9:E416\u2013E9.","journal-title":"J Thorac Dis"},{"key":"2930_CR28","doi-asserted-by":"publisher","first-page":"142","DOI":"10.21037\/jovs.2017.09.08","volume":"3","author":"HY Fang","year":"2017","unstructured":"Fang HY, Chao YK, Hsieh MJ, Wen CT, Ho PH, Tang WJ, Liu YH. Image-guided video-assisted thoracoscopic surgery for small ground glass opacities: a case series. J Vis Surg. 2017;3:142.","journal-title":"J Vis Surg"},{"key":"2930_CR29","doi-asserted-by":"publisher","first-page":"3312","DOI":"10.21037\/tlcr-21-561","volume":"10","author":"J Chen","year":"2021","unstructured":"Chen J, Xie F, Zheng X, Li Y, Liu S, Ma KC, Goto T, Muller T, Chan ED, Sun J. Mobile 3-dimensional (3D) C-arm system-assisted transbronchial biopsy and ablation for ground-glass opacity pulmonary nodules: a case report. Transl Lung Cancer Res. 2021;10:3312\u20139.","journal-title":"Transl Lung Cancer Res"}],"container-title":["BMC Pulmonary Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12890-024-02930-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12890-024-02930-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12890-024-02930-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,3,20]],"date-time":"2024-03-20T17:01:52Z","timestamp":1710954112000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcpulmmed.biomedcentral.com\/articles\/10.1186\/s12890-024-02930-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3,20]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["2930"],"URL":"https:\/\/doi.org\/10.1186\/s12890-024-02930-0","relation":{},"ISSN":["1471-2466"],"issn-type":[{"value":"1471-2466","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,3,20]]},"assertion":[{"value":"17 October 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 February 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 March 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study received approval from the institutional review board of Sir Run Run Hospital. The authors confirm that their study was performed in accordance with the Declaration of Helsinki. Informed consent was approved and waived by the Sir Run Run Hospital Review Board due to retrospective nature of the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not Applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to publish"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"146"}}