{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T02:22:49Z","timestamp":1781662969247,"version":"3.54.5"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2016,1,11]],"date-time":"2016-01-11T00:00:00Z","timestamp":1452470400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2016,12]]},"DOI":"10.1186\/s12891-015-0845-2","type":"journal-article","created":{"date-parts":[[2016,1,11]],"date-time":"2016-01-11T21:34:56Z","timestamp":1452548096000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["A new adjustable parallel drill guide for internal fixation of femoral neck fracture: a developmental and experimental study"],"prefix":"10.1186","volume":"17","author":[{"given":"Varah","family":"Yuenyongviwat","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pakjai","family":"Tuntarattanapong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Boonsin","family":"Tangtrakulwanich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2016,1,11]]},"reference":[{"key":"845_CR1","doi-asserted-by":"crossref","first-page":"1793","DOI":"10.2106\/00004623-199412000-00005","volume":"76","author":"SE Asnis","year":"1994","unstructured":"Asnis SE, Wanek-Sgaglione L. Intracapsular fractures of the femoral neck. Results of cannulated screw fixation. J Bone Joint Surg Am. 1994;76:1793\u2013803.","journal-title":"J Bone Joint Surg Am"},{"key":"845_CR2","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1016\/S0020-1383(00)00125-X","volume":"31","author":"KJ Ravikumar","year":"2000","unstructured":"Ravikumar KJ, Marsh G. Internal fixation versus hemiarthroplasty versus total hip arthroplasty for displaced subcapital fractures of femur\u201413\u00a0year results of a prospective randomised study. Injury. 2000;31:793\u20137.","journal-title":"Injury"},{"key":"845_CR3","first-page":"481","volume":"36","author":"V Tan","year":"2007","unstructured":"Tan V, Wong KL, Born CT, Harten R, DeLong WG. Two-screw femoral neck fracture fixation: a biomechanical analysis of 2 different configurations. Am J Orthop. 2007;36:481\u20135.","journal-title":"Am J Orthop"},{"key":"845_CR4","doi-asserted-by":"publisher","first-page":"632","DOI":"10.1302\/0301-620X.87B5.15237","volume":"87","author":"K Gurusamy","year":"2005","unstructured":"Gurusamy K, Parker MJ, Rowlands TK. The complications of displaced intracapsular fractures of the hip: the effect of screw positioning and angulation on fracture healing. J Bone Joint Surg (Br). 2005;87:632\u20134.","journal-title":"J Bone Joint Surg (Br)"},{"key":"845_CR5","first-page":"438","volume":"32","author":"SG Maurer","year":"2003","unstructured":"Maurer SG, Wright KE, Kummer FJ, Zuckerman JD, Koval KJ. Two or three screws for fixation of femoral neck fractures? Am J Orthop. 2003;32:438\u201342.","journal-title":"Am J Orthop"},{"key":"845_CR6","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1097\/00005131-200303000-00013","volume":"17","author":"P Kloen","year":"2003","unstructured":"Kloen P, Rubel IF, Lyden JP, Helfet DL. Subtrochanteric fracture after cannulated screw fixation of femoral neck fractures: a report of four cases. J Orthop Trauma. 2003;17:225\u20139.","journal-title":"J Orthop Trauma"},{"key":"845_CR7","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1016\/S0020-1383(03)00059-7","volume":"35","author":"VT Selvan","year":"2004","unstructured":"Selvan VT, Oakley MJ, Rangan A, Al-Lami MK. Optimum configuration of cannulated hip screws for the fixation of intracapsular hip fractures: a biomechanical study. Injury. 2004;35:136\u201341.","journal-title":"Injury"},{"key":"845_CR8","doi-asserted-by":"publisher","first-page":"1748","DOI":"10.2106\/JBJS.E.00137","volume":"88","author":"M Liebergall","year":"2006","unstructured":"Liebergall M, Ben-David D, Weil Y, Peyser A, Mosheiff R. Computerized navigation for the internal fixation of femoral neck fractures. J Bone Joint Surg Am. 2006;88:1748\u201354.","journal-title":"J Bone Joint Surg Am"},{"key":"845_CR9","doi-asserted-by":"publisher","first-page":"317","DOI":"10.3109\/10929080601090557","volume":"11","author":"D Kendoff","year":"2006","unstructured":"Kendoff D, H\u00fcfner T, Citak M, Geerling J, Maier C, Wesemeier F, et al. Implementation of a new navigated parallel drill guide for femoral neck fractures. Comput Aided Surg. 2006;11:317\u201321.","journal-title":"Comput Aided Surg"},{"key":"845_CR10","doi-asserted-by":"publisher","first-page":"875","DOI":"10.1007\/s00113-006-1142-1","volume":"109","author":"D Kendoff","year":"2006","unstructured":"Kendoff D, H\u00fcfner T, Citak M, Maier C, Wesemeier F, Pearle A, et al. A new parallel drill guide for navigating femoral neck screw placement. Development and evaluation. Unfallchirurg. 2006;109:875\u201380.","journal-title":"Unfallchirurg"},{"key":"845_CR11","doi-asserted-by":"crossref","unstructured":"Tai T-W, Lien F-C, Lee P-Y, Jou I-M, Lin C-J, Huang Y-H. Using a cannulated screw as a drill guide and sleeve: a simple technique for multiple-screw fixation for intracapsular femoral neck fracture. Orthopedics. 2010;33.","DOI":"10.3928\/01477447-20100625-05"},{"key":"845_CR12","doi-asserted-by":"publisher","first-page":"897","DOI":"10.1007\/s00198-004-1627-0","volume":"15","author":"O Johnell","year":"2004","unstructured":"Johnell O, Kanis JA. An estimate of the worldwide prevalence, mortality and disability associated with hip fracture. Osteoporos Int. 2004;15:897\u2013902.","journal-title":"Osteoporos Int"},{"key":"845_CR13","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1097\/BOT.0000000000000291","volume":"29","author":"AV Florschutz","year":"2015","unstructured":"Florschutz AV, Langford JR, Haidukewych GJ, Koval KJ. Femoral neck fractures. J Orthop Trauma. 2015;29:121\u20139.","journal-title":"J Orthop Trauma"},{"key":"845_CR14","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1016\/S0020-1383(96)00161-1","volume":"28","author":"CA Bout","year":"1997","unstructured":"Bout CA, Cannegieter DM, Juttmann JW. Percutaneous cannulated screw fixation of femoral neck fractures: The three point principle. Injury. 1997;28:135\u20139.","journal-title":"Injury"},{"key":"845_CR15","doi-asserted-by":"crossref","unstructured":"Wu A-M, Wang X-Y, Xia D-D, Luo P, Xu H-Z, Chi Y-L. A novel technique of two-hole guide tube for percutaneous anterior odontoid screw fixation. Spine J. 2015;11.","DOI":"10.1016\/j.spinee.2015.02.013"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-015-0845-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12891-015-0845-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-015-0845-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,6,24]],"date-time":"2017-06-24T03:29:48Z","timestamp":1498274988000},"score":1,"resource":{"primary":{"URL":"http:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-015-0845-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,1,11]]},"references-count":15,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2016,12]]}},"alternative-id":["845"],"URL":"https:\/\/doi.org\/10.1186\/s12891-015-0845-2","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,1,11]]},"article-number":"8"}}