{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,21]],"date-time":"2025-10-21T03:27:11Z","timestamp":1761017231727,"version":"3.37.3"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,7,19]],"date-time":"2018-07-19T00:00:00Z","timestamp":1531958400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"name":"NCS Lab s.r.l. (Carpi, Italia)"},{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2018,12]]},"DOI":"10.1186\/s12891-018-2089-4","type":"journal-article","created":{"date-parts":[[2018,7,19]],"date-time":"2018-07-19T21:22:26Z","timestamp":1532035346000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Biomechanical evaluation of an arthroscopic transosseous repair as a revision option for failed rotator cuff surgery"],"prefix":"10.1186","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2078-2241","authenticated-orcid":false,"given":"Felix","family":"Dyrna","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andreas","family":"Voss","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Leo","family":"Pauzenberger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elifho","family":"Obopilwe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Augustus D.","family":"Mazzocca","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alessandro","family":"Castagna","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cory","family":"Edgar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,7,19]]},"reference":[{"key":"2089_CR1","doi-asserted-by":"crossref","unstructured":"Gazielly DF, Gleyze P, Montagnon C. Functional and anatomical results after rotator cuff repair. Clin Orthop Relat Res 1994;&NA;:43???53.","DOI":"10.1097\/00003086-199407000-00009"},{"key":"2089_CR2","first-page":"1229","volume":"87","author":"P Boileau","year":"2005","unstructured":"Boileau P, Brassart N, Watkinson DJ, Carles M, Hatzidakis AM, Krishnan SG. Arthroscopic repair of full-thickness tears of the supraspinatus: does the tendon really heal? J Bone Joint Surg Am. The American Orthopedic Association. 2005;87:1229\u201340.","journal-title":"J Bone Joint Surg Am"},{"key":"2089_CR3","doi-asserted-by":"publisher","first-page":"219","DOI":"10.2106\/00004623-200402000-00002","volume":"86-A","author":"LM Galatz","year":"2004","unstructured":"Galatz LM, Ball CM, Teefey SA, Middleton WD, Yamaguchi K. The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears. J Bone Joint Surg. 2004;86-A:219\u201324.","journal-title":"J Bone Joint Surg"},{"key":"2089_CR4","doi-asserted-by":"publisher","first-page":"1283","DOI":"10.1177\/0363546517689873","volume":"45","author":"PR Heuberer","year":"2017","unstructured":"Heuberer PR, Smolen D, Pauzenberger L, Plachel F, Salem S, Laky B, et al. Longitudinal long-term magnetic resonance imaging and clinical follow-up after single-row arthroscopic rotator cuff repair: clinical superiority of structural tendon integrity. Am J Sports Med. 2017;45:1283\u20138.","journal-title":"Am J Sports Med"},{"key":"2089_CR5","doi-asserted-by":"publisher","first-page":"1247","DOI":"10.1177\/0363546507301661","volume":"35","author":"C Charousset","year":"2007","unstructured":"Charousset C, Grimberg J, Duranthon L-D, Bellaiche L, Petrover D. Can a double-row anchorage technique improve tendon healing in arthroscopic rotator cuff repair?: a prospective, nonrandomized, comparative study of double-row and single-row anchorage techniques with computed tomographic arthrography tendon healing assessment. Am J Sports Med. 2007;35:1247\u201353.","journal-title":"Am J Sports Med"},{"key":"2089_CR6","doi-asserted-by":"publisher","first-page":"1578","DOI":"10.1007\/s11999-009-0990-8","volume":"468","author":"J-Y Park","year":"2010","unstructured":"Park J-Y, Siti HT, Keum J-S, Moon S-G, Oh K-S. Does an arthroscopic suture bridge technique maintain repair integrity?: a serial evaluation by ultrasonography. Clin Orthop Relat Res. Springer-Verlag. 2010;468:1578\u201387.","journal-title":"Clin Orthop Relat Res"},{"key":"2089_CR7","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1007\/s00167-014-3234-8","volume":"23","author":"P Spennacchio","year":"2015","unstructured":"Spennacchio P, Banfi G, Cucchi D, D'Ambrosi R, Cabitza P, Randelli P. Long-term outcome after arthroscopic rotator cuff treatment. Knee Surg Sports Traumatol Arthrosc. Springer Berlin Heidelberg. 2015;23:523\u20139.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"2089_CR8","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1007\/s00590-009-0579-7","volume":"20","author":"AS Kilinc","year":"2010","unstructured":"Kilinc AS, Giarreti R, Diaz L, Sauzi\u00e8res P, Valenti P. Recurrent rotator cuff tears: an evaluation of open re-surgery results. Eur J Orthop Surg Traumatol. 2010;20:373\u201380.","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"2089_CR9","doi-asserted-by":"publisher","first-page":"1479","DOI":"10.1016\/j.arthro.2013.06.015","volume":"29","author":"N Parnes","year":"2013","unstructured":"Parnes N, DeFranco M, Wells JH, Higgins LD, Warner JJP. Complications after arthroscopic revision rotator cuff repair. Arthroscopy. Elsevier. 2013;29:1479\u201386.","journal-title":"Arthroscopy"},{"key":"2089_CR10","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1177\/0363546509346401","volume":"38","author":"DP Piasecki","year":"2010","unstructured":"Piasecki DP, Verma NN, Nho SJ, Bhatia S, Boniquit N, Cole BJ, et al. Outcomes after arthroscopic revision rotator cuff repair. Am Orthop Soc Sports Med. 2010;38:40\u20136.","journal-title":"Am Orthop Soc Sports Med"},{"key":"2089_CR11","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1053\/jars.2002.30443","volume":"18","author":"F Wilson","year":"2002","unstructured":"Wilson F, Hinov V, Adams G. Arthroscopic repair of full-thickness tears of the rotator cuff: 2- to 14-year follow-up. Arthroscopy. 2002;18:136\u201344.","journal-title":"Arthroscopy"},{"key":"2089_CR12","doi-asserted-by":"publisher","first-page":"1031","DOI":"10.1007\/s00167-011-1725-4","volume":"20","author":"R Garofalo","year":"2012","unstructured":"Garofalo R, Castagna A, Borroni M, Krishnan SG. Arthroscopic transosseous (anchorless) rotator cuff repair. Knee Surg Sports Traumatol Arthrosc. 2012;20:1031\u20135.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"2089_CR13","doi-asserted-by":"publisher","first-page":"e183","DOI":"10.1016\/j.eats.2013.02.001","volume":"2","author":"KP Lavery","year":"2013","unstructured":"Lavery KP, Rasmussen JF, Dhawan A. Arthroscopic transosseous-equivalent rotator cuff repair. Arthrosc Tech. 2013;2:e183\u20135.","journal-title":"Arthrosc Tech"},{"key":"2089_CR14","doi-asserted-by":"publisher","first-page":"89","DOI":"10.4055\/cios.2013.5.2.89","volume":"5","author":"TQ Lee","year":"2013","unstructured":"Lee TQ. Current biomechanical concepts for rotator cuff repair. Clin Orthop Surg. 2013;5:89\u201397.","journal-title":"Clin Orthop Surg"},{"key":"2089_CR15","doi-asserted-by":"publisher","first-page":"603","DOI":"10.1016\/j.arthro.2006.04.001","volume":"22","author":"AS Curtis","year":"2006","unstructured":"Curtis AS, Burbank KM, Tierney JJ, Scheller AD, Curran AR. The insertional footprint of the rotator cuff: an anatomic study. Arthroscopy. 2006;22:603\u2013609.e1.","journal-title":"Arthroscopy"},{"key":"2089_CR16","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.arthro.2004.09.020","volume":"21","author":"S Lee","year":"2005","unstructured":"Lee S, Mahar A, Bynum K, Pedowitz R. Biomechanical comparison of bioabsorbable sutureless screw anchor versus suture anchor fixation for rotator cuff repair. Arthroscopy. 2005;21:43\u20137.","journal-title":"Arthroscopy"},{"key":"2089_CR17","doi-asserted-by":"publisher","first-page":"895","DOI":"10.1016\/j.arthro.2014.06.001","volume":"30","author":"SS Burkhart","year":"2014","unstructured":"Burkhart SS. Reprint of: the deadman theory of suture anchors: observations along a South Texas fence line. Arthroscopy. 2014;30:895\u20139.","journal-title":"Arthroscopy"},{"key":"2089_CR18","doi-asserted-by":"publisher","first-page":"1861","DOI":"10.1177\/0363546505279575","volume":"33","author":"AD Mazzocca","year":"2005","unstructured":"Mazzocca AD, Millett PJ, Guanche CA, Santangelo SA, Arciero RA. Arthroscopic single-row versus double-row suture anchor rotator cuff repair. Am J Sports Med. 2005;33:1861\u20138.","journal-title":"Am J Sports Med"},{"issue":"Suppl 1","key":"2089_CR19","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1007\/s12306-013-0254-3","volume":"97","author":"P Baudi","year":"2013","unstructured":"Baudi P, Rasia Dani E, Campochiaro G, Rebuzzi M, Serafini F, Catani F. The rotator cuff tear repair with a new arthroscopic transosseous system: the Sharc-FT(\u00ae). Musculoskelet Surg Springer Milan. 2013;97(Suppl 1):57\u201361.","journal-title":"Musculoskelet Surg"},{"key":"2089_CR20","doi-asserted-by":"publisher","first-page":"1148","DOI":"10.1177\/0363546512437835","volume":"40","author":"K Beitzel","year":"2012","unstructured":"Beitzel K, Chowaniec DM, McCarthy MB, Cote MP, Russell RP, Obopilwe E, et al. Stability of double-row rotator cuff repair is not adversely affected by scaffold interposition between tendon and bone. Am J Sports Med. 2012;40:1148\u201354.","journal-title":"Am J Sports Med"},{"key":"2089_CR21","doi-asserted-by":"publisher","first-page":"1991","DOI":"10.1177\/0363546509336260","volume":"37","author":"LJ Bisson","year":"2009","unstructured":"Bisson LJ, Manohar LM. A biomechanical comparison of transosseous-suture anchor and suture bridge rotator cuff repairs in cadavers. Am J Sports Med. 2009;37:1991\u20135.","journal-title":"Am J Sports Med"},{"key":"2089_CR22","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1016\/S0749-8063(97)90151-1","volume":"13","author":"SS Burkhart","year":"1997","unstructured":"Burkhart SS, Johnson TC, Wirth MA, Athanasiou KA. Cyclic loading of transosseous rotator cuff repairs: tension overload as a possible cause of failure. Arthroscopy. 1997;13:172\u20136.","journal-title":"Arthroscopy"},{"key":"2089_CR23","doi-asserted-by":"publisher","first-page":"1168","DOI":"10.1016\/j.arthro.2006.07.004","volume":"22","author":"SW Meier","year":"2006","unstructured":"Meier SW, Meier JD. The effect of double-row fixation on initial repair strength in rotator cuff repair: a biomechanical study. Arthroscopy. 2006;22:1168\u201373.","journal-title":"Arthroscopy"},{"key":"2089_CR24","doi-asserted-by":"publisher","first-page":"1034","DOI":"10.2106\/JBJS.G.00049","volume":"90","author":"N Zheng","year":"2008","unstructured":"Zheng N, Harris HW, Andrews JR. Failure analysis of rotator cuff repair: a comparison of three double-row techniques. J Bone Joint Surg Am. 2008;90:1034\u201342.","journal-title":"J Bone Joint Surg Am"},{"key":"2089_CR25","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1177\/0363546505281238","volume":"34","author":"DH Kim","year":"2006","unstructured":"Kim DH, ElAttrache NS, Tibone JE, Jun B-J, DeLaMora SN, Kvitne RS, et al. Biomechanical comparison of a single-row versus double-row suture anchor technique for rotator cuff repair. Am J Sports Med. 2006;34:407\u201314.","journal-title":"Am J Sports Med"},{"key":"2089_CR26","doi-asserted-by":"publisher","first-page":"1197","DOI":"10.1016\/j.arthro.2012.02.015","volume":"28","author":"FA Barber","year":"2012","unstructured":"Barber FA, Drew OR. A biomechanical comparison of tendon-bone interface motion and cyclic loading between single-row, triple-loaded cuff repairs and double-row, suture-tape cuff repairs using biocomposite anchors. Arthroscopy. 2012;28:1197\u2013205.","journal-title":"Arthroscopy"},{"key":"2089_CR27","doi-asserted-by":"publisher","first-page":"2559","DOI":"10.1007\/s00167-012-1922-9","volume":"20","author":"W Anderl","year":"2012","unstructured":"Anderl W, Heuberer PR, Laky B, Kriegleder B, Reihsner R, Eberhardsteiner J. Superiority of bridging techniques with medial fixation on initial strength. Knee Surg Sports Traumatol Arthrosc. 2012;20:2559\u201366.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"2089_CR28","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1016\/j.arthro.2013.11.018","volume":"30","author":"JJ Iyengar","year":"2014","unstructured":"Iyengar JJ, Samagh SP, Schairer W, Singh G, Valone FH III, Feeley BT. Current trends in rotator cuff repair: surgical technique, setting, and cost. Arthroscopy. 2014;30:284\u20138.","journal-title":"Arthroscopy"},{"key":"2089_CR29","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1097\/00003086-199407000-00002","volume":"304","author":"HL McLaughlin","year":"1994","unstructured":"McLaughlin HL. Lesions of the musculotendinous cuff of the shoulder. The exposure and treatment of tears with retraction. 1944. Clin Orthop Relat Res. 1994;304:3\u20139.","journal-title":"Clin Orthop Relat Res"},{"key":"2089_CR30","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1302\/0301-620X.76B3.8175836","volume":"76","author":"C Gerber","year":"1994","unstructured":"Gerber C, Schneeberger AG, Beck M, Schlegel U. Mechanical strength of repairs of the rotator cuff. J Bone Joint Surg Br. 1994;76:371\u201380.","journal-title":"J Bone Joint Surg Br"},{"key":"2089_CR31","doi-asserted-by":"publisher","first-page":"504","DOI":"10.1007\/s00167-007-0460-3","volume":"16","author":"MF Pietschmann","year":"2008","unstructured":"Pietschmann MF, Fr\u00f6hlich V, Ficklscherer A, Hausdorf J, Utzschneider S, Jansson V, et al. Pullout strength of suture anchors in comparison with transosseous sutures for rotator cuff repair. Knee Surg Sports Traumatol Arthrosc. Springer-Verlag. 2008;16:504\u201310.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"2089_CR32","doi-asserted-by":"publisher","first-page":"710","DOI":"10.1016\/j.arthro.2007.01.027","volume":"23","author":"RZ Tashjian","year":"2007","unstructured":"Tashjian RZ, Levanthal E, Spenciner DB, Green A, Fleming BC. Initial fixation strength of massive rotator cuff tears: in vitro comparison of single-row suture anchor and transosseous tunnel constructs. Arthroscopy. 2007;23:710\u20136.","journal-title":"Arthroscopy"},{"key":"2089_CR33","doi-asserted-by":"publisher","first-page":"1496","DOI":"10.1177\/0363546507313574","volume":"36","author":"JB Frank","year":"2008","unstructured":"Frank JB, ElAttrache NS, Dines JS, Blackburn A, Crues J, Tibone JE. Repair site integrity after arthroscopic transosseous-equivalent suture-bridge rotator cuff repair. Am J Sports Med. 2008;36:1496\u2013503.","journal-title":"Am J Sports Med"},{"key":"2089_CR34","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1177\/0363546511426071","volume":"40","author":"SB Behrens","year":"2012","unstructured":"Behrens SB, Bruce B, Zonno AJ, Paller D, Green A. Initial fixation strength of transosseous-equivalent suture bridge rotator cuff repair is comparable with transosseous repair. Am J Sports Med. 2012;40:133\u201340.","journal-title":"Am J Sports Med"},{"key":"2089_CR35","doi-asserted-by":"publisher","first-page":"542","DOI":"10.1177\/0363546506296310","volume":"35","author":"H Sano","year":"2007","unstructured":"Sano H, Yamashita T, Wakabayashi I, Itoi E. Stress distribution in the supraspinatus tendon after tendon repair: suture anchors versus transosseous suture fixation. Am J Sports Med. 2007;35:542\u20136.","journal-title":"Am J Sports Med"},{"key":"2089_CR36","doi-asserted-by":"publisher","first-page":"1869","DOI":"10.1177\/0363546505278256","volume":"33","author":"Y Tuoheti","year":"2005","unstructured":"Tuoheti Y, Itoi E, Yamamoto N, Seki N, Abe H, Minagawa H, et al. Contact area, contact pressure, and pressure patterns of the tendon-bone interface after rotator cuff repair. Am J Sports Med. 2005;33:1869\u201374.","journal-title":"Am J Sports Med"},{"key":"2089_CR37","doi-asserted-by":"publisher","first-page":"1466","DOI":"10.1177\/0363546503262644","volume":"32","author":"MJ Tingart","year":"2004","unstructured":"Tingart MJ, Apreleva M, Lehtinen J, Zurakowski D, Warner JJP. Anchor design and bone mineral density affect the pull-out strength of suture anchors in rotator cuff repair: which anchors are best to use in patients with low bone quality? Am J Sports Med. 2004;32:1466\u201373.","journal-title":"Am J Sports Med"},{"key":"2089_CR38","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1016\/j.arthro.2005.08.042","volume":"22","author":"A Mahar","year":"2006","unstructured":"Mahar A, Allred DW, Wedemeyer M, Abbi G, Pedowitz R. A biomechanical and radiographic analysis of standard and intracortical suture anchors for arthroscopic rotator cuff repair. Arthroscopy. 2006;22:130\u20135.","journal-title":"Arthroscopy"},{"key":"2089_CR39","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1053\/jars.2002.32930","volume":"18","author":"M Apreleva","year":"2002","unstructured":"Apreleva M, Ozbaydar M, Fitzgibbons PG, Warner JJP, et al. Arthroscopy. 2002;18:519\u201326.","journal-title":"Arthroscopy"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-018-2089-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12891-018-2089-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-018-2089-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,27]],"date-time":"2022-08-27T22:36:26Z","timestamp":1661639786000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-018-2089-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7,19]]},"references-count":39,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,12]]}},"alternative-id":["2089"],"URL":"https:\/\/doi.org\/10.1186\/s12891-018-2089-4","relation":{},"ISSN":["1471-2474"],"issn-type":[{"type":"electronic","value":"1471-2474"}],"subject":[],"published":{"date-parts":[[2018,7,19]]},"assertion":[{"value":"8 January 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 May 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 July 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The biomechanics portion of the above study was conducted using only de-identified cadaveric specimens and is therefore not considered human subjects research. The study was reported via Human Research Determination Form to the institutional review board (IRB) of the University of Connecticut and it was documented, that no IRB approval was required While this form does not require IRB review, we have confirmed with our IRB that projects conducted in our biomechanics laboratory that utilize de-identified specimens does not constitute human subjects research and therefore no review required. No consent was required for the biomechanical study.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The following authors declare that they have no competing interests: AV, LP, EO, AC.The following authors declare that they have competing interests:- FD received finical support from the German Research Foundation (DFG) and the Technische Universit\u00e4t M\u00fcnchen for publication of this manuscript (processing fee).- ADM received research funding from Arthrex Inc., (Naples, Fl, USA).- CE received direct funding and material support for this study from NCS Lab s.r.l. (Carpi, Italia).None of the authors have non-financial competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing Interests"}},{"value":"Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Publisher\u2019s Note"}}],"article-number":"240"}}