{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T02:32:26Z","timestamp":1787020346911,"version":"build-2736575974"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,12,1]],"date-time":"2019-12-01T00:00:00Z","timestamp":1575158400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2019,12,5]],"date-time":"2019-12-05T00:00:00Z","timestamp":1575504000000},"content-version":"vor","delay-in-days":4,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100007307","name":"Arthrex","doi-asserted-by":"publisher","award":["none"],"award-info":[{"award-number":["none"]}],"id":[{"id":"10.13039\/100007307","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2019,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Little is known about the strains at the glenoid near the bone-implant interface in reverse shoulder arthroplasty. The purpose of the current study was to evaluate the strains on the glenoid bone under a compressive load after implantation of three different sizes of metal-backed baseplates in either inferior or superior position in combination with three different sizes of glenospheres and three different glenosphere designs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Three sizes of baseplates (small, medium, large) were implanted in thirty-six paired human cadaveric scapulae either inferior, flush with the glenoid neck, or with a 5\u2009mm superior offset. Glenospheres were available in three sizes (36\u2009mm, 39\u2009mm, 42\u2009mm) and designs (standard, 4\u2009mm lateralized, 2.5\u2009mm inferiorized). Specimens were mounted in a servo-hydraulic testing apparatus at a 60\u00b0 angle between the glenoid and actuator holding the humeral component. Four strain-gauge rosettes were placed around the glenoid rim to measure strains transferred to the scapular bone under a compressive load (750\u2009N) relative to the various baseplate-glenosphere combinations. Following repeated compression, a load-to-failure test was performed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Mean overall registered strains were 161\u03bc\u03b5 (range: \u2212\u20091165 to 2347) at the inferior sensor, \u22122\u03bc\u03b5 (range: \u2212\u2009213 to 90) at the superior sensor, \u221295\u03bc\u03b5 (range: \u2212\u2009381 to 254) at the anterior sensor, and 13\u03bc\u03b5 (range: \u2212\u2009298 to 128) at the posterior sensor. Measured bone strains did not show any significant differences across tested baseplate and glenosphere design, size, or positioning combinations (\n                      <jats:italic>p\u2009&gt;\u20090.05<\/jats:italic>\n                      for all sensors). Furthermore, linear regression analysis did not identify any of the evaluated parameters as an independent influential factor for strains (\n                      <jats:italic>p\u2009&gt;\u20090.05<\/jats:italic>\n                      for all sensors). Mean load-at-failure was significantly higher in the group of inferior (3347.0\u2009N\u2009\u00b1\u2009704.4\u2009N) compared to superior (2763.8\u2009N\u2009\u00b1\u2009927.8\u2009N) positioned baseplates\n                      <jats:italic>(p\u2009=\u20090.046)<\/jats:italic>\n                      .\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Different baseplate positions, baseplate sizes, glenosphere sizes, and glenosphere design or various combinations of these parameters did not significantly influence the measured bone strains at the glenoid near the bone-implant interface in a contemporary reverse shoulder arthroplasty system.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of evidence<\/jats:title>\n                    <jats:p>Basic Science Study, Biomechanical Study.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12891-019-2968-3","type":"journal-article","created":{"date-parts":[[2019,12,5]],"date-time":"2019-12-05T18:02:36Z","timestamp":1575568956000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Influence of Glenosphere and baseplate parameters on Glenoid bone strains in reverse shoulder Arthroplasty"],"prefix":"10.1186","volume":"20","author":[{"given":"Leo","family":"Pauzenberger","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cory","family":"Dwyer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elifho","family":"Obopilwe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael D.","family":"Nowak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"Cote","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony A.","family":"Romeo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Augustus D.","family":"Mazzocca","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2078-2241","authenticated-orcid":false,"given":"Felix","family":"Dyrna","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,12,5]]},"reference":[{"issue":"2","key":"2968_CR1","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1302\/2058-5241.3.170044","volume":"3","author":"F Familiari","year":"2018","unstructured":"Familiari F, Rojas J, Nedim Doral M, Huri G, McFarland EG. Reverse total shoulder arthroplasty. EFORT Open Rev. 2018;3(2):58\u201369. https:\/\/doi.org\/10.1302\/2058-5241.3.170044.","journal-title":"EFORT Open Rev"},{"issue":"9","key":"2968_CR2","doi-asserted-by":"publisher","first-page":"e265","DOI":"10.1016\/j.jse.2017.03.039","volume":"26","author":"N Sevivas","year":"2017","unstructured":"Sevivas N, Ferreira N, Andrade R, Moreira P, Portugal R, Alves D, et al. Reverse shoulder arthroplasty for irreparable massive rotator cuff tears: a systematic review with meta-analysis and meta-regression. J Shoulder Elb Surg. 2017;26(9):e265\u201377. https:\/\/doi.org\/10.1016\/j.jse.2017.03.039.","journal-title":"J Shoulder Elb Surg"},{"issue":"2","key":"2968_CR3","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1080\/17434440.2019.1568237","volume":"16","author":"JM Kazley","year":"2019","unstructured":"Kazley JM, Cole KP, Desai KJ, Zonshayn S, Morse AS, Banerjee S. Prostheses for reverse total shoulder arthroplasty. Expert Rev Med Devices. 2019;16(2):107\u201318. https:\/\/doi.org\/10.1080\/17434440.2019.1568237.","journal-title":"Expert Rev Med Devices"},{"issue":"1","key":"2968_CR4","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1016\/j.jse.2010.08.001","volume":"20","author":"MA Zumstein","year":"2011","unstructured":"Zumstein MA, Pinedo M, Old J, Boileau P. Problems, complications, reoperations, and revisions in reverse total shoulder arthroplasty: a systematic review. J Shoulder Elb Surg. 2011;20(1):146\u201357. https:\/\/doi.org\/10.1016\/j.jse.2010.08.001.","journal-title":"J Shoulder Elb Surg"},{"issue":"6","key":"2968_CR5","doi-asserted-by":"publisher","first-page":"998","DOI":"10.1002\/jor.22015","volume":"30","author":"SC Mordecai","year":"2012","unstructured":"Mordecai SC, Lambert SM, Meswania JM, Blunn GW, Bayley IL, Taylor SJG. An experimental glenoid rim strain analysis for an improved reverse anatomy shoulder implant fixation. J Orthop Res. 2012;30(6):998\u20131003. https:\/\/doi.org\/10.1002\/jor.22015.","journal-title":"J Orthop Res"},{"issue":"3","key":"2968_CR6","doi-asserted-by":"publisher","first-page":"397","DOI":"10.2106\/00004623-198466030-00012","volume":"66","author":"CT Rubin","year":"1984","unstructured":"Rubin CT, Lanyon LE. Regulation of bone formation by applied dynamic loads. J Bone Joint Surg Am. 1984;66(3):397\u2013402.","journal-title":"J Bone Joint Surg Am"},{"key":"2968_CR7","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1097\/00003086-199401000-00022","volume":"298","author":"CT Rubin","year":"1994","unstructured":"Rubin CT, McLeod KJ. Promotion of bony ingrowth by frequency-specific, low-amplitude mechanical strain. Clin Orthop Relat Res. 1994;298:165\u201374.","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"2968_CR8","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1007\/s10439-005-8964-9","volume":"33","author":"R Ruimerman","year":"2005","unstructured":"Ruimerman R, Van Rietbergen B, Hilbers P, Huiskes R. The effects of trabecular-bone loading variables on the surface signaling potential for bone remodeling and adaptation. Ann Biomed Eng. 2005;33(1):71\u20138.","journal-title":"Ann Biomed Eng"},{"issue":"3","key":"2968_CR9","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1016\/0169-6009(92)90875-E","volume":"19","author":"HM Frost","year":"1992","unstructured":"Frost HM. Perspectives: bone's mechanical usage windows. Bone Miner. 1992;19(3):257\u201371.","journal-title":"Bone Miner"},{"issue":"9","key":"2968_CR10","doi-asserted-by":"publisher","first-page":"2432","DOI":"10.1007\/s11999-010-1733-6","volume":"469","author":"EL Flatow","year":"2011","unstructured":"Flatow EL, Harrison AK. A history of reverse total shoulder arthroplasty. Clin Orthop Relat Res. 2011;469(9):2432\u20139. https:\/\/doi.org\/10.1007\/s11999-010-1733-6.","journal-title":"Clin Orthop Relat Res"},{"key":"2968_CR11","first-page":"165","volume":"135","author":"NK Poppen","year":"1978","unstructured":"Poppen NK, Walker PS. Forces at the glenohumeral joint in abduction. Clin Orthop Relat Res. 1978;135:165\u201370.","journal-title":"Clin Orthop Relat Res"},{"issue":"7","key":"2968_CR12","doi-asserted-by":"publisher","first-page":"963","DOI":"10.1016\/j.jse.2012.10.035","volume":"22","author":"CP Roche","year":"2013","unstructured":"Roche CP, Stroud NJ, Martin BL, Steiler CA, Flurin P-H, Wright TW, et al. The impact of scapular notching on reverse shoulder glenoid fixation. J Shoulder Elb Surg. 2013;22(7):963\u201370. https:\/\/doi.org\/10.1016\/j.jse.2012.10.035.","journal-title":"J Shoulder Elb Surg"},{"issue":"1 Suppl S","key":"2968_CR13","doi-asserted-by":"publisher","first-page":"162S","DOI":"10.1016\/j.jse.2004.09.030","volume":"14","author":"M Harman","year":"2005","unstructured":"Harman M, Frankle M, Vasey M, Banks S. Initial glenoid component fixation in \u201creverse\u201d total shoulder arthroplasty: a biomechanical evaluation. J Shoulder Elbow Surg. 2005;14(1 Suppl S):162S\u20137S. https:\/\/doi.org\/10.1016\/j.jse.2004.09.030.","journal-title":"J Shoulder Elbow Surg"},{"issue":"4","key":"2968_CR14","doi-asserted-by":"publisher","first-page":"544","DOI":"10.1016\/j.jse.2009.10.006","volume":"19","author":"MP Hoenig","year":"2010","unstructured":"Hoenig MP, Loeffler B, Brown S, Peindl R, Fleischli J, Connor P, et al. Reverse glenoid component fixation: is a posterior screw necessary? J Shoulder Elb Surg. 2010;19(4):544\u20139. https:\/\/doi.org\/10.1016\/j.jse.2009.10.006.","journal-title":"J Shoulder Elb Surg"},{"issue":"6","key":"2968_CR15","doi-asserted-by":"publisher","first-page":"974","DOI":"10.1016\/j.jse.2008.04.012","volume":"17","author":"AR Hopkins","year":"2008","unstructured":"Hopkins AR, Hansen UN, Bull AMJ, Emery R, Amis AA. Fixation of the reversed shoulder prosthesis. J Shoulder Elb Surg. 2008;17(6):974\u201380. https:\/\/doi.org\/10.1016\/j.jse.2008.04.012.","journal-title":"J Shoulder Elb Surg"},{"issue":"2","key":"2968_CR16","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1080\/00031305.1998.10480550","volume":"52","author":"A Agresti","year":"1998","unstructured":"Agresti A, Coull BA. Approximate is better than \u201cexact\u201d for interval estimation of binomial proportions. Am Stat. 1998;52(2):119\u201326. https:\/\/doi.org\/10.1080\/00031305.1998.10480550.","journal-title":"Am Stat"},{"issue":"2","key":"2968_CR17","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1111\/j.1600-0501.2004.01000.x","volume":"15","author":"A Mellal","year":"2004","unstructured":"Mellal A, Wiskott HWA, Botsis J, Scherrer SS, Belser UC. Stimulating effect of implant loading on surrounding bone. Comparison of three numerical models and validation by in vivo data. Clin Oral Implants Res. 2004;15(2):239\u201348 Available from: http:\/\/eutils.ncbi.nlm.nih.gov\/entrez\/eutils\/elink.fcgi?dbfrom=pubmed&id=15008937&retmode=ref&cmd=prlinks.","journal-title":"Clin Oral Implants Res"},{"issue":"4","key":"2968_CR18","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1016\/S8756-3282(98)00113-6","volume":"23","author":"JR Mosley","year":"1998","unstructured":"Mosley JR, Lanyon LE. Strain rate as a controlling influence on adaptive modeling in response to dynamic loading of the ulna in growing male rats. Bone. 1998;23(4):313\u20138 Available from: http:\/\/eutils.ncbi.nlm.nih.gov\/entrez\/eutils\/elink.fcgi?dbfrom=pubmed&id=9763142&retmode=ref&cmd=prlinks.","journal-title":"Bone"},{"issue":"1","key":"2968_CR19","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1016\/0021-9290(94)00156-1","volume":"29","author":"CA Pattin","year":"1996","unstructured":"Pattin CA, Caler WE, Carter DR. Cyclic mechanical property degradation during fatigue loading of cortical bone. J Biomech. 1996;29(1):69\u201379 Available from: https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/0021929094001561doi:10.1016\/0021-9290(94)00156-1.","journal-title":"J Biomech"},{"issue":"1","key":"2968_CR20","first-page":"15","volume":"15","author":"JB Brunski","year":"2000","unstructured":"Brunski JB, Puleo DA, Nanci A. Biomaterials and biomechanics of oral and maxillofacial implants: current status and future developments. Int J Oral Maxillofac Implants. 2000;15(1):15\u201346.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"3","key":"2968_CR21","first-page":"104","volume":"23","author":"DC Holmes","year":"1997","unstructured":"Holmes DC, Loftus JT. Influence of bone quality on stress distribution for endosseous implants. J Oral Implantol. 1997;23(3):104\u201311.","journal-title":"J Oral Implantol"},{"issue":"3","key":"2968_CR22","first-page":"357","volume":"18","author":"S Tada","year":"2003","unstructured":"Tada S, Stegaroiu R, Kitamura E, Miyakawa O, Kusakari H. Influence of implant design and bone quality on stress\/strain distribution in bone around implants: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants. 2003;18(3):357\u201368.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"3","key":"2968_CR23","first-page":"482","volume":"25","author":"M Hudieb","year":"2010","unstructured":"Hudieb M, Wakabayashi N, Suzuki T, Kasugai S. Morphologic classification and stress analysis of the mandibular bone in the premolar region for implant placement. Int J Oral Maxillofac Implants. 2010;25(3):482\u201390 Available from: http:\/\/eutils.ncbi.nlm.nih.gov\/entrez\/eutils\/elink.fcgi?dbfrom=pubmed&id=20556246&retmode=ref&cmd=prlinks.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"6","key":"2968_CR24","doi-asserted-by":"publisher","first-page":"925","DOI":"10.1016\/j.jse.2008.02.010","volume":"17","author":"C L\u00e9vigne","year":"2008","unstructured":"L\u00e9vigne C, Boileau P, Favard L, Garaud P, Mole D, Sirveaux F, et al. Scapular notching in reverse shoulder arthroplasty. J Shoulder Elb Surg. 2008;17(6):925\u201335. https:\/\/doi.org\/10.1016\/j.jse.2008.02.010.","journal-title":"J Shoulder Elb Surg"},{"issue":"5","key":"2968_CR25","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1016\/j.jse.2004.09.010","volume":"14","author":"RW Nyffeler","year":"2005","unstructured":"Nyffeler RW, Werner CML, Gerber C. Biomechanical relevance of glenoid component positioning in the reverse Delta III total shoulder prosthesis. J Shoulder Elb Surg. 2005;14(5):524\u20138. https:\/\/doi.org\/10.1016\/j.jse.2004.09.010.","journal-title":"J Shoulder Elb Surg"},{"issue":"8","key":"2968_CR26","doi-asserted-by":"publisher","first-page":"1742","DOI":"10.2106\/JBJS.E.00851","volume":"88","author":"J Guery","year":"2006","unstructured":"Guery J, Favard L, Sirveaux F, Oudet D, Mole D, Walch G. Reverse total shoulder arthroplasty. Survivorship analysis of eighty replacements followed for five to ten years. J Bone Joint Surg Am. 2006;88(8):1742\u20137. https:\/\/doi.org\/10.2106\/JBJS.E.00851.","journal-title":"J Bone Joint Surg Am"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-019-2968-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12891-019-2968-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-019-2968-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,7]],"date-time":"2022-10-07T16:36:06Z","timestamp":1665160566000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-019-2968-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12]]},"references-count":26,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["2968"],"URL":"https:\/\/doi.org\/10.1186\/s12891-019-2968-3","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,12]]},"assertion":[{"value":"10 August 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 November 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 December 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The biomechanics portion of the above study was conducted using only de-identified cadaveric specimens and is therefore not considered human subjects research. The study was reported via Human Research Determination Form to the institutional review board (IRB) of the University of Connecticut and it was documented, that no IRB approval was required. While this form does not require IRB review, we have confirmed with our IRB that projects conducted in our biomechanics laboratory that utilize de-identified specimens does not constitute human subjects research and therefore no review required. No consent was required for the biomechanical study.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"No consent for publication was needed, because of the de-identified data.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The following authors declare that they have no competing interests: LP, CRD, EO, MDN, MC.The following authors declare that they have competing interests:FD received finical support from the German Research Foundation (DFG) and the Technische Universit\u00e4t M\u00fcnchen for publication of this manuscript (processing fee).ADM. receives consultant fees and research support from Arthrex Inc.; AAR. receives consultant fees, royalties, and research support from Arthrex Inc. The University of Connecticut Health Center\/UConn Musculoskeletal Institute has received direct funding and material support for this study from Arthrex Inc. The company had no influence on study design, data collection, interpretation of the results, or the final manuscript.None of the authors have non-financial competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"587"}}