{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,6]],"date-time":"2026-11-06T08:26:48Z","timestamp":1793953608387,"version":"4.8.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,5,11]],"date-time":"2020-05-11T00:00:00Z","timestamp":1589155200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,5,11]],"date-time":"2020-05-11T00:00:00Z","timestamp":1589155200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Acute hip pain caused by femoral proximal fractures or acute hip arthritis requires imaging for accurate diagnosis. Although pocket-sized ultrasound (PsUS) offers several advantages over other imaging modalities, there is limited information regarding its use in diagnosing femoral proximal fractures or acute hip arthritis. Thus, we aimed to validate the diagnostic accuracy of PsUS for both disorders.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In this prospective observational study, outpatients with acute hip pain were diagnosed according to a fixed procedure of the PsUS probe handling. We verified the diagnostic accuracy of PsUS findings (cortical discontinuity and joint fluid retention) and compared it with that of radiography, computed tomography, and magnetic resonance imaging.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Our study included 52 outpatients (mean age, 78.0\u2009years; female, 88.5%). Of 26 patients diagnosed with femoral proximal fractures, 14 had femoral neck fractures and 12 had femoral trochanteric fractures. The sensitivity and specificity for identifying cortical discontinuity in femoral proximal fractures were 0.96 and 0.92, respectively. The sensitivity for identifying either cortical discontinuity or joint fluid retention in femoral proximal fractures or acute hip arthritis was 0.97.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Negative PsUS findings of cortical discontinuity and joint fluid retention in the hip are useful for ruling out femoral proximal fractures and acute hip arthritis. PsUS and radiography have comparable diagnostic accuracies, and PsUS could aid in the initial assessment of acute hip pain among the elderly in primary care settings.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12891-020-03326-x","type":"journal-article","created":{"date-parts":[[2020,5,11]],"date-time":"2020-05-11T11:04:18Z","timestamp":1589195058000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Initial assessment of femoral proximal fracture and acute hip arthritis using pocket-sized ultrasound: a prospective observational study in a primary care setting in Japan"],"prefix":"10.1186","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8569-7887","authenticated-orcid":false,"given":"Takashi","family":"Akimoto","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tadashi","family":"Kobayashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroki","family":"Maita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroshi","family":"Osawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyuki","family":"Kato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,5,11]]},"reference":[{"key":"3326_CR1","first-page":"27","volume":"89","author":"JJ Wilson","year":"2014","unstructured":"Wilson JJ, Furukawa M. Evaluation of the patient with hip pain. Am Fam Phys. 2014;89:27\u201334.","journal-title":"Am Fam Phys"},{"key":"3326_CR2","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1016\/j.vaccine.2017.08.087","volume":"37","author":"A Woerner","year":"2019","unstructured":"Woerner A, Pourmalek F, Panozzo C, Pileggi G, Hudson M, Caric A, et al. Acute aseptic arthritis: case definition and guidelines for data collection, analysis, and presentation of immunisation safety data. Vaccine. 2019;37:384\u201391.","journal-title":"Vaccine."},{"key":"3326_CR3","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1016\/j.clinimag.2011.08.013","volume":"36","author":"V Beltrame","year":"2012","unstructured":"Beltrame V, Stramare R, Rebellato N, Angelini F, Frigo AC, Rubaltelli L. Sonographic evaluation of bone fractures: a reliable alternative in clinical practice? Clin Imag. 2012;36:203\u20138.","journal-title":"Clin Imag"},{"key":"3326_CR4","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1186\/s12873-019-0226-5","volume":"19","author":"N Champagne","year":"2019","unstructured":"Champagne N, Eadie L, Regan L, Wilson P. The effectiveness of ultrasound in the detection of fractures in adults with suspected upper or lower limb injury: a systematic review and subgroup meta-analysis. BMC Emerg Med. 2019;19:17.","journal-title":"BMC Emerg Med"},{"key":"3326_CR5","doi-asserted-by":"publisher","first-page":"1083","DOI":"10.1056\/NEJMp1311944","volume":"370","author":"SD Solomon","year":"2014","unstructured":"Solomon SD, Saldana F. Point-of-care ultrasound in medical education - stop listening and look. NEJM. 2014;370:1083\u20135.","journal-title":"NEJM."},{"key":"3326_CR6","doi-asserted-by":"publisher","first-page":"276","DOI":"10.14442\/jgfm.17.4_276","volume":"17","author":"T Kobayashi","year":"2016","unstructured":"Kobayashi T, Kato H. Development of pocket-sized hand-held ultrasound devices enhancing people's abilities and need for education on them. J Gen Fam Med. 2016;17:276\u201388.","journal-title":"J Gen Fam Med"},{"key":"3326_CR7","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1136\/jramc-150-02-01","volume":"150","author":"AJ Brooks","year":"2004","unstructured":"Brooks AJ, Price V, Simms M, Ward N, Hand CJ. Handheld ultrasound diagnosis of extremity fractures. J Royal Army Med Corps. 2004;150:78\u201380.","journal-title":"J Royal Army Med Corps"},{"key":"3326_CR8","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1080\/10903120802474513","volume":"13","author":"CR McNeil","year":"2009","unstructured":"McNeil CR, McManus J, Mehta S. The accuracy of portable ultrasonography to diagnose fractures in an austere environment. Prehospital Emerg Car. 2009;13:50\u20132.","journal-title":"Prehospital Emerg Car"},{"key":"3326_CR9","first-page":"462","volume":"50","author":"E Nishioka","year":"2001","unstructured":"Nishioka E, Endo T, Miyazaki T, Yoshida K, Nagata K. Ultrasound examination of the femoral neck fracture. Ortho Traumatol. 2001;50:462\u20136 [In Japanese].","journal-title":"Ortho Traumatol"},{"key":"3326_CR10","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1370\/afm.2330","volume":"17","author":"CA Andersen","year":"2019","unstructured":"Andersen CA, Holden S, Vela J, Rathleff MS, Jensen MB. Point-of-care ultrasound in general practice: a systematic review. Ann Fam Med. 2019;17:61\u20139.","journal-title":"Ann Fam Med"},{"key":"3326_CR11","doi-asserted-by":"publisher","first-page":"1474","DOI":"10.7205\/MILMED-D-14-00241","volume":"179","author":"P Bornemann","year":"2014","unstructured":"Bornemann P, Bornemann G. Military family physicians' perceptions of a pocket point-of-care ultrasound device in clinical practice. Military Med. 2014;179:1474\u20137.","journal-title":"Military Med"},{"key":"3326_CR12","doi-asserted-by":"publisher","first-page":"420","DOI":"10.1016\/j.jhsa.2017.03.012","volume":"42","author":"BC Lau","year":"2017","unstructured":"Lau BC, Robertson A, Motamedi D, Lee N. The validity and reliability of a pocket-sized ultrasound to diagnose distal radius fracture and assess quality of closed reduction. J Hand Surg. 2017;42:420\u20137.","journal-title":"J Hand Surg"},{"key":"3326_CR13","first-page":"S33","volume":"32","author":"EG Kellam","year":"2018","unstructured":"Kellam EG, Agel J, Karam MD, Roberts CS. Fracture and dislocation classification compendium - 2018 international comprehensive classification of fractures and dislocations committee. Femur J Ortho Traum. 2018;32:S33\u201344.","journal-title":"Femur J Ortho Traum"},{"key":"3326_CR14","doi-asserted-by":"publisher","first-page":"367","DOI":"10.3109\/17453678508994349","volume":"56","author":"P Kallio","year":"1985","unstructured":"Kallio P, Ry\u00f6ppy S, J\u00e4ppinen S, Siponmaa A-K, J\u00e4\u00e4skel\u00e4inen J, Kunnamo I. Ultrasonography in hip disease in children AU - Kallio. Pentti Acta Orthop Scand. 1985;56:367\u201371.","journal-title":"Pentti Acta Orthop Scand"},{"key":"3326_CR15","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1038\/bmt.2012.244","volume":"48","author":"Y Kanda","year":"2013","unstructured":"Kanda Y. Investigation of the freely available easy-to-use software 'EZR' for medical statistics. Bone Marrow Transpl. 2013;48:452\u20138.","journal-title":"Bone Marrow Transpl"},{"key":"3326_CR16","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1259\/0007-1285-64-761-403","volume":"64","author":"SL Lewis","year":"1991","unstructured":"Lewis SL, Rees JI, Thomas GV, Williams LA. Pitfalls of bone scintigraphy in suspected hip fractures. Br J Radiol. 1991;64:403\u20138.","journal-title":"Br J Radiol"},{"key":"3326_CR17","first-page":"251","volume":"69","author":"J Fairclough","year":"1987","unstructured":"Fairclough J, Colhoun E, Johnston D, Williams LA. Bone scanning for suspected hip fractures. A prospective study in elderly patients. JBJS Br. 1987;69:251\u20133.","journal-title":"JBJS Br"},{"key":"3326_CR18","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1016\/S0735-6757(97)90095-4","volume":"15","author":"SL Adams","year":"1997","unstructured":"Adams SL, Yarnold PR. Clinical use of the patellar-pubic percussion sign in hip trauma. Am J Emerg Med. 1997;15:173\u20135.","journal-title":"Am J Emerg Med"},{"key":"3326_CR19","first-page":"467","volume":"43","author":"M Tiru","year":"2002","unstructured":"Tiru M, Goh SH, Low BY. Use of percussion as a screening tool in the diagnosis of occult hip fractures. Singap Med J. 2002;43:467\u20139.","journal-title":"Singap Med J"},{"key":"3326_CR20","doi-asserted-by":"publisher","first-page":"e621","DOI":"10.3928\/01477447-20120426-13","volume":"35","author":"CC Chiang","year":"2012","unstructured":"Chiang CC, Wu HT, Lin CF, Tzeng YH, Huang CK, Chen WM, et al. Analysis of initial injury radiographs of occult femoral neck fractures in elderly patients: a pilot study. Orthoped. 2012;35:e621\u20137.","journal-title":"Orthoped."},{"key":"3326_CR21","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1097\/01241398-199010040-00015","volume":"10","author":"F McGoldrick","year":"1990","unstructured":"McGoldrick F, Bourke T, Blake N, Fogarty E, Dowling F, Regan B. Accuracy of sonography in transient synovitis. J Ped Orthoped. 1990;10:501\u20133.","journal-title":"J Ped Orthoped"},{"key":"3326_CR22","doi-asserted-by":"publisher","first-page":"1447","DOI":"10.7863\/jum.2009.28.11.1447","volume":"28","author":"O Safran","year":"2009","unstructured":"Safran O, Goldman V, Applbaum Y, Milgrom C, Bloom R, Peyser A, et al. Posttraumatic painful hip: sonography as a screening test for occult hip fractures. J Ultrasound Med. 2009;28:1447\u201352.","journal-title":"J Ultrasound Med"},{"key":"3326_CR23","doi-asserted-by":"publisher","first-page":"773","DOI":"10.1016\/j.crad.2018.05.008","volume":"73","author":"Y Arlachov","year":"2018","unstructured":"Arlachov Y, Ibrahem AR. Acute hip pain: mimics of a femoral neck fracture. Clin Radiol. 2018;73:773\u201381.","journal-title":"Clin Radiol"},{"key":"3326_CR24","first-page":"89","volume":"19","author":"PV Balint","year":"2001","unstructured":"Balint PV, Sturrock RD. Intraobserver repeatability and interobserver reproducibility in musculoskeletal ultrasound imaging measurements. Clin Exp Rheumatol. 2001;19:89\u201392.","journal-title":"Clin Exp Rheumatol"},{"key":"3326_CR25","doi-asserted-by":"publisher","first-page":"1634","DOI":"10.1007\/s00247-010-1689-4","volume":"40","author":"S Ramwadhdoebe","year":"2010","unstructured":"Ramwadhdoebe S, Sakkers RJ, Uiterwaal CS, Boere-Boonekamp MM, Beek FJ. Evaluation of a training program for general ultrasound screening for developmental dysplasia of the hip in preventive child health care. Ped Radiol. 2010;40:1634\u20139.","journal-title":"Ped Radiol"},{"key":"3326_CR26","doi-asserted-by":"publisher","first-page":"2013","DOI":"10.1093\/rheumatology\/kes161","volume":"51","author":"A Iagnocco","year":"2012","unstructured":"Iagnocco A, Perricone C, Scirocco C, Ceccarelli F, Modesti M, Gattamelata A, et al. The interobserver reliability of ultrasound in knee osteoarthritis. Rheumatol. 2012;51:2013\u20139.","journal-title":"Rheumatol."},{"key":"3326_CR27","doi-asserted-by":"publisher","first-page":"3932","DOI":"10.1007\/s00330-015-4189-y","volume":"26","author":"D Collin","year":"2016","unstructured":"Collin D, Geijer M, Gothlin JH. Computed tomography compared to magnetic resonance imaging in occult or suspect hip fractures. A retrospective study in 44 patients. Eu Radiol. 2016;26:3932\u20138.","journal-title":"Eu Radiol"},{"key":"3326_CR28","doi-asserted-by":"publisher","first-page":"766","DOI":"10.1136\/ard.58.12.766","volume":"58","author":"N Bellamy","year":"1999","unstructured":"Bellamy N, Tesar P, Walker D, Klestov A, Muirden K, Kuhnert P, et al. Perceptual variation in grading hand, hip and knee radiographs: observations based on an Australian twin registry study of osteoarthritis. Ann Rheum Dis. 1999;58:766\u20139.","journal-title":"Ann Rheum Dis"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-020-03326-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-020-03326-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-020-03326-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,10]],"date-time":"2021-05-10T19:28:21Z","timestamp":1620674901000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-020-03326-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5,11]]},"references-count":28,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["3326"],"URL":"https:\/\/doi.org\/10.1186\/s12891-020-03326-x","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.2.10620\/v2","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.2.10620\/v1","asserted-by":"object"}]},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,5,11]]},"assertion":[{"value":"10 June 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 May 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 May 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study, approved by the medical ethics committee of Hirosaki University (2015\u2013260, 2nd April, 2015) and National Hospital Organization Morioka Hospital (Morioka Hospital) (2015\u201310, 1st February, 2015), included patients with acute hip pain who visited the emergency outpatient unit at Morioka Hospital, which provides primary care in the area, from April 2016 to March 2017. We opted out of the study and obtained verbal informed consent from all patients under the approval of the ethics committees.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The participants gave their consent to participate in the study and were informed that any publications based on the data would not include identifying information.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"291"}}