{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,8]],"date-time":"2026-03-08T07:03:57Z","timestamp":1772953437005,"version":"3.50.1"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,8,1]],"date-time":"2020-08-01T00:00:00Z","timestamp":1596240000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,8,1]],"date-time":"2020-08-01T00:00:00Z","timestamp":1596240000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Foundation of Shanghai Municipal Commission of Health and Family Planning","award":["ZK2015A-14"],"award-info":[{"award-number":["ZK2015A-14"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Background<\/jats:title>\n<jats:p>To demonstrate the correlation between guide pin-shaft angle (PSA) at the anteroposterior film and anteversion angle of guide pin at the lateral film and investigate whether excellent tip\u2013apex distance (TAD) can be obtained by changing the entry point via axial rotation of the main intramedullary nail.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>Fifty patients with intertrochanteric femoral fractures (IFFs) undergoing internal fixation with intramedullary nails under 2D fluoroscopy were retrospectively enrolled. Both of the PSA at the anteroposterior film and anteversion angle at the lateral film before and after adjustment of the guide pin were collected. Pearson correlation analysis was performed to investigate their correlation. Intraoperative and postoperative outcomes were recorded. Furthermore, the software of Mimics 10.0 and Pro\/E were used to establish the 3D models of the proximal femur and main intramedullary nail\/guide pin, respectively. Surgery was simulated on the Pro\/E software platform and solid geometry analysis was conducted to calculate the correlation between the PSA and the anteversion angle.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>Pearson correlation analysis indicated there was a positive correlation between PSA and anteversion angle, with the correlation coefficient of 0.902 (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.01). By altering the PSA and anteversion angle, TAD was adjusted to be less than 25\u2009mm in all patients. The mean operative time, fluoroscopy time and length of hospital stay were 65.82\u2009\u00b1\u200911.16\u2009min, 2.03\u2009\u00b1\u20090.79\u2009min and 6.66\u2009\u00b1\u20092.49 d. Thirty-one patients received blood transfusions (3.55\u2009\u00b1\u20091.95\u2009U). Fracture reduction was considered to be good or acceptable in all patients. Complications occurred only in 6 patients (12.00%). At a 3-month follow-up, the mean Timed Up and Go was 31.54\u2009\u00b1\u200920.95\u2009s and Harris Hip Score was 72.88\u2009\u00b1\u20098.79. The 3D surgery model also showed when the main intramedullary nail was externally rotated or internally rotated of 20\u00b0 at the standard location, the PSA of guide pin at the anteroposterior position and anteversion angle of the guide pin at the lateral position were simultaneously increased or decreased.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusion<\/jats:title>\n<jats:p>Our findings suggest altering the PSA and anteversion angle may be beneficial for obtaining excellent TAD and achieving superior outcomes.<\/jats:p>\n<\/jats:sec>","DOI":"10.1186\/s12891-020-03518-5","type":"journal-article","created":{"date-parts":[[2020,8,1]],"date-time":"2020-08-01T13:02:43Z","timestamp":1596286963000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["How to get better TAD? Relationship between anteversion angle of nail and position of femoral neck guide pin during nailing of intertrochanteric fractures"],"prefix":"10.1186","volume":"21","author":[{"given":"Zhe","family":"Wang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yadong","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shenglong","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiuhui","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Changjian","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xin","family":"Tang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,8,1]]},"reference":[{"key":"3518_CR1","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1067\/mhc.2000.109232","volume":"5","author":"SB Thacker","year":"2000","unstructured":"Thacker SB, Branche C, Stevens JA, Olson S. Reducing falls and resulting hip fractures among older women. Home Care Provid. 2000;5:134\u201341.","journal-title":"Home Care Provid"},{"key":"3518_CR2","doi-asserted-by":"publisher","first-page":"157","DOI":"10.1007\/s11657-013-0157-9","volume":"8","author":"BH Yoon","year":"2013","unstructured":"Yoon BH, Lee YK, Kim SC, Kim SH, Ha YC, Koo KH. Epidemiology of proximal femoral fractures in South Korea. Arch Osteoporos. 2013;8:157.","journal-title":"Arch Osteoporos"},{"key":"3518_CR3","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1007\/PL00004148","volume":"7","author":"B Gullberg","year":"1997","unstructured":"Gullberg B, Johnell O, Kanis JA. World-wide projections for hip fracture. Osteoporos Int. 1997;7:407\u201313.","journal-title":"Osteoporos Int"},{"key":"3518_CR4","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1007\/s00264-016-3308-y","volume":"41","author":"AB Li","year":"2017","unstructured":"Li AB, Zhang WJ, Wang J, Guo WJ, Wang XH, Zhao YM. Intramedullary and extramedullary fixations for the treatment of unstable femoral intertrochanteric fractures: a meta-analysis of prospective randomized controlled trials. Int Orthop. 2017;41:403\u201313.","journal-title":"Int Orthop"},{"key":"3518_CR5","doi-asserted-by":"publisher","first-page":"961","DOI":"10.1007\/s00402-013-1764-z","volume":"133","author":"YK Lee","year":"2013","unstructured":"Lee YK, Chung CY, Park MS, Lee KM, Koo KH. Intramedullary nail versus extramedullary plate fixation for unstable intertrochanteric fractures: decision analysis. Arch Orthop Trauma Surg. 2013;133:961\u20138.","journal-title":"Arch Orthop Trauma Surg"},{"key":"3518_CR6","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1016\/j.otsr.2014.07.023","volume":"100","author":"KL Ma","year":"2014","unstructured":"Ma KL, Wang X, Luan FJ, Xu HT, Fang Y, Min J, Luan HX, Yang F, Zheng H, He SJ. Proximal femoral nails antirotation, gamma nails, and dynamic hip screws for fixation of intertrochanteric fractures of femur: a meta-analysis. Orthop Traumatol Surg Res. 2014;100:859\u201366.","journal-title":"Orthop Traumatol Surg Res"},{"key":"3518_CR7","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1186\/s13000-014-0191-y","volume":"9","author":"D Wu","year":"2014","unstructured":"Wu D, Ren G, Peng C, Zheng X, Mao F, Zhang Y. InterTan nail versus Gamma3 nail for intramedullary nailing of unstable trochanteric fractures. Diagn Pathol. 2014;9:191.","journal-title":"Diagn Pathol"},{"key":"3518_CR8","doi-asserted-by":"publisher","first-page":"15962","DOI":"10.1038\/s41598-017-16315-3","volume":"7","author":"JX Ma","year":"2017","unstructured":"Ma JX, Kuang MJ, Fan ZR, Xing F, Zhao YL, Zhang LK, Chen HT, Han C, Ma XL. Comparison of clinical outcomes with InterTan vs gamma nail or PFNA in the treatment of intertrochanteric fractures: a meta-analysis. Sci Rep. 2017;7:15962.","journal-title":"Sci Rep"},{"key":"3518_CR9","doi-asserted-by":"publisher","first-page":"1062","DOI":"10.1007\/s00776-015-0706-8","volume":"20","author":"S Li","year":"2015","unstructured":"Li S, Chang SM, Niu WX, Ma H. Comparison of tip apex distance and cut-out complications between helical blades and lag screws in intertrochanteric fractures among the elderly: a meta-analysis. J Orthop Sci. 2015;20:1062\u20139.","journal-title":"J Orthop Sci"},{"key":"3518_CR10","doi-asserted-by":"publisher","first-page":"470","DOI":"10.1007\/s00113-011-1975-0","volume":"114","author":"M Kraus","year":"2011","unstructured":"Kraus M, Krischak G, Wiedmann K, Riepl C, Gebhard F, J\u00f6ckel JA, Scola A. Clinical evaluation of PFNA\u00ae and relationship between the tip-apex distance and mechanical failure. Unfallchirurg. 2011;114:470\u20138.","journal-title":"Unfallchirurg"},{"key":"3518_CR11","first-page":"e207","volume":"30","author":"SAWA Flores","year":"2016","unstructured":"Flores SAWA, Caroom C, Jenkins M. The utility of the tip-apex distance in predicting axial migration and cutout with the trochanteric fixation nail system helical blade. J Orthop Trauma. 2016;30:e207\u201311.","journal-title":"J Orthop Trauma"},{"key":"3518_CR12","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0170048","volume":"12","author":"JC Yang","year":"2017","unstructured":"Yang JC, Chen HC, Lai YS, Cheng CK. Measurement of tip apex distance and migration of lag screws and novel blade screw used for the fixation of intertrochanteric fractures. PLoS One. 2017;12:e0170048.","journal-title":"PLoS One"},{"key":"3518_CR13","doi-asserted-by":"publisher","first-page":"1843","DOI":"10.1016\/j.injury.2017.06.020","volume":"48","author":"M Yam","year":"2017","unstructured":"Yam M, Chawla A, Kwek E. Rewriting the tip apex distance for the proximal femoral nail anti-rotation. Injury. 2017;48:1843\u20137.","journal-title":"Injury"},{"key":"3518_CR14","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1186\/1471-2474-15-189","volume":"15","author":"M Regling","year":"2014","unstructured":"Regling M, Blau A, Probe RA, Maxey JW, Solberg BD. Improved lag screw positioning in the treatment of proximal femur fractures using a novel computer assisted surgery method: a cadaveric study. BMC Musculoskelet Disord. 2014;15:189.","journal-title":"BMC Musculoskelet Disord"},{"key":"3518_CR15","doi-asserted-by":"publisher","first-page":"786","DOI":"10.1016\/j.injury.2007.12.019","volume":"39","author":"LJ Johnson","year":"2008","unstructured":"Johnson LJ, Cope MR, Shahrokhi S, Tamblyn P. Measuring tip-apex distance using a picture archiving and communication system (PACS). Injury. 2008;39:786\u201390.","journal-title":"Injury"},{"key":"3518_CR16","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1308\/rcsann.2016.0282","volume":"99","author":"C Quah","year":"2017","unstructured":"Quah C, Mehta R, Shivji FS, Hassan S, Chandrasenan J, Moran CG, Forward DP. The effect of surgical experience on the amount of radiation exposure from fluoroscopy during dynamic hip screw fixation. Ann R Coll Surg Engl. 2017;99:198\u2013202.","journal-title":"Ann R Coll Surg Engl"},{"key":"3518_CR17","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1016\/j.jos.2016.03.001","volume":"21","author":"D Sakagoshi","year":"2016","unstructured":"Sakagoshi D, Sawaguchi T, Shima Y, Inoue D, Oshima T, Goldhahn S. A refined definition improves the measurement reliability of the tip-apex distance. J Orthop Sci. 2016;21:475\u201380.","journal-title":"J Orthop Sci"},{"key":"3518_CR18","doi-asserted-by":"publisher","first-page":"1346","DOI":"10.1016\/j.injury.2015.04.041","volume":"46","author":"J Wright","year":"2015","unstructured":"Wright J, Kahane S, Moeed A, Macdowell A. Accuracy of the surgeon's eye: use of the tip\u2013apex distance in clinical practice. Injury. 2015;46:1346\u20138.","journal-title":"Injury"},{"key":"3518_CR19","doi-asserted-by":"publisher","first-page":"2155","DOI":"10.1016\/j.injury.2016.07.018","volume":"47","author":"M Kuhl","year":"2016","unstructured":"Kuhl M, Beimel C. Enhanced cephalomedullary nail lag screw placement and intraoperative tip-apex distance measurement with a novel computer assisted surgery system. Injury. 2016;47:2155\u201360.","journal-title":"Injury"},{"key":"3518_CR20","doi-asserted-by":"publisher","first-page":"1302","DOI":"10.1016\/j.injury.2016.03.029","volume":"47","author":"S Li","year":"2016","unstructured":"Li S, Chang SM, Jin YM, Zhang YQ, Niu WX, Du SC, Zhang LZ, Ma H. A mathematical simulation of the tip-apex distance and the calcar-referenced tip-apex distance for intertrochanteric fractures reduced with lag screws. Injury. 2016;47:1302\u20138.","journal-title":"Injury"},{"key":"3518_CR21","first-page":"143","volume":"101","author":"J Li","year":"2015","unstructured":"Li J, Cheng L, Jing J. The Asia proximal femoral nail antirotation versus the standard proximal femoral antirotation nail for unstable intertrochanteric fractures in elderly Chinese patients. Injury. 2015;101:143\u20136.","journal-title":"Injury"},{"issue":"2","key":"3518_CR22","doi-asserted-by":"publisher","first-page":"810","DOI":"10.1093\/ptj\/81.2.810","volume":"81","author":"S Morris","year":"2001","unstructured":"Morris S, Morris ME, Iansek R. Reliability of measurements obtained with the timed \u201cup & go\u201d test in people with Parkinson disease. Phys Ther. 2001;81(2):810\u20138.","journal-title":"Phys Ther"},{"issue":"4","key":"3518_CR23","doi-asserted-by":"publisher","first-page":"737","DOI":"10.2106\/00004623-196951040-00012","volume":"51","author":"WH Harris","year":"1969","unstructured":"Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by Moore arthroplasty. J Bone Joint Surg Am. 1969;51(4):737\u201355.","journal-title":"J Bone Joint Surg Am"},{"key":"3518_CR24","doi-asserted-by":"publisher","first-page":"1058","DOI":"10.2106\/00004623-199507000-00012","volume":"77","author":"MR Baumgaertner","year":"1995","unstructured":"Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM. The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am. 1995;77:1058\u201364.","journal-title":"J Bone Joint Surg Am"},{"key":"3518_CR25","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1007\/s00776-013-0402-5","volume":"18","author":"J Rubio-Avila","year":"2013","unstructured":"Rubio-Avila J, Madden K, Simunovic N, Bhandari M. Tip to apex distance in femoral intertrochanteric fractures: a systematic review. J Orthop Sci. 2013;18:592\u20138.","journal-title":"J Orthop Sci"},{"key":"3518_CR26","first-page":"6781070","volume":"2017","author":"AB Li","year":"2017","unstructured":"Li AB, Zhang WJ, Wang JQ, Zhao YM, Guo WJ. Learning curve and clinical outcomes of performing surgery with the InterTan intramedullary nail in treating femoral intertrochanteric fractures. Biomed Res Int. 2017;2017:6781070.","journal-title":"Biomed Res Int"},{"key":"3518_CR27","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1007\/s00590-008-0309-6","volume":"18","author":"RBI Mark","year":"2008","unstructured":"Mark RBI, Ruurd LJ. Intramedullary hip screw Wxation of reverse oblique and transverse trochanteric femur fractures. Eur J Orthop Surg Traumatol. 2008;18:323\u20136.","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"3518_CR28","doi-asserted-by":"publisher","first-page":"1441","DOI":"10.1007\/s00590-019-02454-y","volume":"29","author":"A Duramaz","year":"2019","unstructured":"Duramaz A, \u0130lter MH. The impact of proximal femoral nail type on clinical and radiological outcomes in the treatment of intertrochanteric femur fractures: a comparative study. Eur J Orthop Surg Traumatol. 2019;29:1441\u20139.","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"3518_CR29","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1097\/BOT.0000000000001145","volume":"32","author":"AS Gavaskar","year":"2018","unstructured":"Gavaskar AS, Tummala NC, Srinivasan P, Gopalan H, Karthik B, Santosh S. Helical blade or the integrated lag screws: a matched pair analysis of 100 patients with unstable trochanteric fractures. J Orthop Trauma. 2018;32:274\u20137.","journal-title":"J Orthop Trauma"},{"key":"3518_CR30","doi-asserted-by":"publisher","first-page":"1035","DOI":"10.1007\/s00590-019-02401-x","volume":"29","author":"S Mallya","year":"2019","unstructured":"Mallya S, Kamath SU, Madegowda A, Krishnamurthy SL, Jain MK, Holla R. Comparison of radiological and functional outcome of unstable intertrochanteric femur fractures treated using PFN and PFNA-2 in patients with osteoporosis. Eur J Orthop Surg Traumatol. 2019;29:1035\u201342.","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"3518_CR31","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1186\/1749-799X-8-35","volume":"8","author":"AN Nikoloski","year":"2013","unstructured":"Nikoloski AN, Osbrough AL, Yates PJ. Should the tip-apex distance (TAD) rule be modified for the proximal femoral nail antirotation (PFNA)? A retrospective study. J Orthop Surg Res. 2013;8:35.","journal-title":"J Orthop Surg Res"},{"key":"3518_CR32","doi-asserted-by":"publisher","first-page":"1451","DOI":"10.1007\/s00590-019-02481-9","volume":"29","author":"B Boukebous","year":"2019","unstructured":"Boukebous B, Flouzat-Lachaniette CH, Donadio J, Chenguel Z, Guillon P, Rousseau MA. Femoral offset loss and internal arch restoration defect are correlated with intramedullary nail cut-out complications after pertrochanteric fractures: a case-control study. Eur J Orthop Surg Traumatol. 2019;29:1451\u201360.","journal-title":"Eur J Orthop Surg Traumatol"},{"issue":"11","key":"3518_CR33","doi-asserted-by":"publisher","first-page":"1361","DOI":"10.1016\/j.injury.2005.06.039","volume":"36","author":"NP Walton","year":"2005","unstructured":"Walton NP, Wynn-Jones H, Ward MS, Wimhurst JA. Femoral neck-shaft angle in extra-capsular proximal femoral fracture fixation; does it make a TAD of difference? Injury. 2005;36(11):1361\u20134.","journal-title":"Injury"},{"issue":"7","key":"3518_CR34","doi-asserted-by":"publisher","first-page":"e258","DOI":"10.1097\/BOT.0000000000001175","volume":"32","author":"AR Bhashyam","year":"2018","unstructured":"Bhashyam AR, Rodriguez EK, Appleton P, Wixted JJ. The effect of hip positioning on the projected femoral neck-shaft angle: a modeling study. J Orthop Trauma. 2018;32(7):e258\u201362.","journal-title":"J Orthop Trauma"},{"issue":"6","key":"3518_CR35","doi-asserted-by":"publisher","first-page":"736","DOI":"10.1097\/01241398-200011000-00007","volume":"20","author":"RM Kay","year":"2000","unstructured":"Kay RM, Jaki KA, Skaggs DL. The effect of femoral rotation on the projected femoral neck-shaft angle. J Pediatr Orthop. 2000;20(6):736\u20139.","journal-title":"J Pediatr Orthop"},{"key":"3518_CR36","doi-asserted-by":"publisher","first-page":"2827","DOI":"10.1007\/s11999-008-0285-5","volume":"466","author":"B Aros","year":"2008","unstructured":"Aros B, Tosteson A, Gottlieb DJ, Koval KJ. Is a sliding hip screw or IM nail the preferred implant for intertrochanteric fracture fixation? Clin Orthop Relat Res. 2008;466:2827\u201332.","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"3518_CR37","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1097\/TA.0b013e318256a0b6","volume":"73","author":"JW Roberts","year":"2012","unstructured":"Roberts JW, Libet LA, Wolinsky PR. Who is in danger? Impingement and penetration of the anterior cortex of the distal femur during intramedullary nailing of proximal femur fractures: preoperatively measurable risk factors. J Trauma Acute Care Surg. 2012;73(1):249\u201354.","journal-title":"J Trauma Acute Care Surg"},{"issue":"11","key":"3518_CR38","doi-asserted-by":"publisher","first-page":"1533","DOI":"10.1007\/s00402-015-2313-8","volume":"135","author":"OR Pe\u00f1a","year":"2015","unstructured":"Pe\u00f1a OR, G\u00f3mez G\u00e9lvez A, Espinosa KA, Cardona JR. Cephalomedullary nails: factors associated with impingement of the anterior cortex of the femur in a Hispanic population. Arch Orthop Trauma Surg. 2015;135(11):1533\u201340.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"2","key":"3518_CR39","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1016\/j.injury.2017.11.017","volume":"49","author":"SM Chang","year":"2018","unstructured":"Chang SM, Hu SJ, Ma Z, Du SC, Zhang YQ. Femoral intertrochanteric nail (fitn): a new short version design with an anterior curvature and a geometric match study using post-operative radiographs. Injury. 2018;49(2):328\u201333.","journal-title":"Injury"},{"key":"3518_CR40","doi-asserted-by":"publisher","first-page":"1628","DOI":"10.12659\/MSM.890962","volume":"20","author":"K Zhang","year":"2014","unstructured":"Zhang K, Zhang S, Yang J, Dong W, Wang S, Cheng Y, Alqwbani M, Wang Q, Yu B. Proximal femoral nail vs. dynamic hip screw in treatment of intertrochanteric fractures: a meta-analysis. Med Sci Monit. 2014;20:1628\u201333.","journal-title":"Med Sci Monit"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-020-03518-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-020-03518-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-020-03518-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,31]],"date-time":"2021-07-31T23:13:50Z","timestamp":1627773230000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-020-03518-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,1]]},"references-count":40,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["3518"],"URL":"https:\/\/doi.org\/10.1186\/s12891-020-03518-5","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8,1]]},"assertion":[{"value":"10 January 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 July 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 August 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was approved by ethics committee of the First Affiliated Hospital of Dalian Medical University. All subjects gave a written informed consent to participate in the surgery.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All patients gave written consent for publication of images and data.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no conflict of interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"512"}}