{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T18:08:48Z","timestamp":1790791728813,"version":"4.1.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,8,12]],"date-time":"2020-08-12T00:00:00Z","timestamp":1597190400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,8,12]],"date-time":"2020-08-12T00:00:00Z","timestamp":1597190400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100010256","name":"Guangzhou Municipal Science and Technology Project","doi-asserted-by":"crossref","award":["201803010046"],"award-info":[{"award-number":["201803010046"]}],"id":[{"id":"10.13039\/501100010256","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81672232"],"award-info":[{"award-number":["81672232"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100012245","name":"Science and Technology Planning Project of Guangdong Province","doi-asserted-by":"crossref","award":["2015B020233013"],"award-info":[{"award-number":["2015B020233013"]}],"id":[{"id":"10.13039\/501100012245","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>C1-ring osteosynthesis is a valid alternative to posterior C1\u2013C2 or C0\u2013C2 fusion to preserve important C1\u2013C2 motion in the treatment of unstable atlas fractures. Nevertheless, the fixation instruments used in current studies for transoral anterior C1-ring osteosynthesis were not suitable for anterior anatomy of the atlas or did not have reduction mechanism. We therefore present this report to investigate preliminary clinical effects of transoral anterior C1-ring osteosynthesis using a laminoplasty plate in unstable atlas fractures.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>From January 2014 to December 2017, 13 patients with unstable atlas fractures were retrospectively reviewed. All patients were treated with transoral anterior C1-ring osteosynthesis using a laminoplasty plate. Pre- and postoperative images were obtained to assess reduction of the fracture, internal fixation placement, and bone union. Neurological function, range of motion, and pain levels were evaluated clinically on follow-up.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The surgeries were successfully performed in all cases. The average follow-up duration was 16.6\u2009\u00b1\u20094.4\u2009months (range 12\u201324\u2009months). One patient suffered screw loosening after operation and underwent replacement operation subsequently. Satisfactory clinical outcomes were achieved in all patients with ideal fracture reduction, reliable plate placement, well-preserved range of motion, and neck pain alleviation. All patients achieved bone union of fractures without loss of reduction or implant failure or C1\u2013C2 instability during the follow-up. No vascular or neurological complication was noted during the operation and follow-up.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Transoral anterior C1-ring osteosynthesis using a laminoplasty plate is a effective surgical treatment for unstable atlas fractures. This technique has a ingenious reduction mechanism, and can provide satisfactory bone union and preservation of C1\u2013C2 motion.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12891-020-03575-w","type":"journal-article","created":{"date-parts":[[2020,8,12]],"date-time":"2020-08-12T08:03:47Z","timestamp":1597219427000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Motion-preserving treatment of unstable atlas fracture: transoral anterior C1-ring osteosynthesis using a laminoplasty plate"],"prefix":"10.1186","volume":"21","author":[{"given":"Xiaobao","family":"Zou","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Beiping","family":"Ouyang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Binbin","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haozhi","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Su","family":"Ge","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuyue","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ling","family":"Ni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuang","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hong","family":"Xia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zenghui","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiangyang","family":"Ma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,8,12]]},"reference":[{"key":"3575_CR1","doi-asserted-by":"publisher","first-page":"2332","DOI":"10.1016\/j.spinee.2015.06.052","volume":"15","author":"C Matthiessen","year":"2015","unstructured":"Matthiessen C, Robinson Y. Epidemiology of atlas fractures--a national registry-based cohort study of 1,537 cases. Spine J. 2015;15:2332\u20137.","journal-title":"Spine J"},{"key":"3575_CR2","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1016\/j.spinee.2017.06.029","volume":"18","author":"YS Zhang","year":"2018","unstructured":"Zhang YS, Zhang JX, Yang QG, Li W, Tao H, Shen CL. Posterior osteosynthesis with monoaxial lateral mass screw-rod system for unstable C1 burst fractures. Spine J. 2018;18:107\u201314.","journal-title":"Spine J"},{"key":"3575_CR3","first-page":"1105","volume":"12","author":"C Lee","year":"1991","unstructured":"Lee C, Woodring JH. Unstable Jefferson variant atlas fractures: an unrecognized cervical injury. Am J Neuroradiol. 1991;12:1105\u201310.","journal-title":"Am J Neuroradiol"},{"key":"3575_CR4","doi-asserted-by":"publisher","first-page":"1963","DOI":"10.1097\/00007632-199809150-00008","volume":"23","author":"TT Lee","year":"1998","unstructured":"Lee TT, Green BA, Petrin DR. Treatment of stable burst fracture of the atlas (Jefferson fracture) with rigid cervical collar. Spine (Phila Pa 1976). 1998;23:1963\u20137.","journal-title":"Spine (Phila Pa 1976)"},{"key":"3575_CR5","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1007\/s00701-019-03824-5","volume":"161","author":"MK Kim","year":"2019","unstructured":"Kim MK, Shin JJ. Comparison of radiological and clinical outcomes after surgical reduction with fixation or halo-vest immobilization for treating unstable atlas fractures. Acta Neurochir. 2019;161:685\u201393.","journal-title":"Acta Neurochir"},{"key":"3575_CR6","doi-asserted-by":"publisher","first-page":"e316","DOI":"10.1016\/j.wneu.2017.12.053","volume":"111","author":"HS Kim","year":"2018","unstructured":"Kim HS, Cloney MB, Koski TR, Smith ZA, Dahdaleh NS. Management of isolated atlas fractures: a retrospective study of 65 patients. World Neurosurg. 2018;111:e316\u201322.","journal-title":"World Neurosurg"},{"key":"3575_CR7","doi-asserted-by":"publisher","first-page":"823","DOI":"10.1097\/01.BRS.0000116984.42466.7E","volume":"29","author":"M Ruf","year":"2004","unstructured":"Ruf M, Melcher R, Harms J. Transoral reduction and osteosynthesis C1 as a function-preserving option in the treatment of unstable Jefferson fractures. Spine (Phila Pa 1976). 2004;29:823\u20137.","journal-title":"Spine (Phila Pa 1976)"},{"key":"3575_CR8","doi-asserted-by":"publisher","first-page":"2232","DOI":"10.1007\/s00586-013-2870-x","volume":"22","author":"W Ma","year":"2013","unstructured":"Ma W, Xu N, Hu Y, Li G, Zhao L, Sun S, Jiang W, Liu G, Gu Y, Liu J. Unstable atlas fracture treatment by anterior plate C1-ring osteosynthesis using a transoral approach. Eur Spine J. 2013;22:2232\u20139.","journal-title":"Eur Spine J"},{"key":"3575_CR9","doi-asserted-by":"publisher","first-page":"145","DOI":"10.4103\/0019-5413.128750","volume":"48","author":"Y Hu","year":"2014","unstructured":"Hu Y, Albert TJ, Kepler CK, Ma WH, Yuan ZS, Dong WX. Unstable Jefferson fractures: results of transoral osteosynthesis. Indian J Orthop. 2014;48:145\u201351.","journal-title":"Indian J Orthop"},{"key":"3575_CR10","doi-asserted-by":"publisher","first-page":"450","DOI":"10.1097\/00007632-198805000-00002","volume":"13","author":"CD Landells","year":"1998","unstructured":"Landells CD, Van Peteghem PK. Fractures of the atlas: classification, treatment and morbidity. Spine (Phila Pa 1976). 1998;13:450\u20132.","journal-title":"Spine (Phila Pa 1976)"},{"key":"3575_CR11","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1097\/00006123-199601000-00012","volume":"38","author":"CA Dickman","year":"1996","unstructured":"Dickman CA, Greene KA, Sonntag VK. Injuries involving the transverse atlantal ligament: classification and treatment guidelines based upon experience with 39 injuries. Neurosurgery. 1996;38:44\u201350.","journal-title":"Neurosurgery"},{"key":"3575_CR12","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/S0021-9290(00)00169-X","volume":"34","author":"EC Teo","year":"2001","unstructured":"Teo EC, Ng HW. First cervical vertebra (atlas) fracture mechanism studies using finite element method. J Biomech. 2001;34:13\u201321.","journal-title":"J Biomech"},{"key":"3575_CR13","doi-asserted-by":"publisher","first-page":"1049","DOI":"10.1016\/j.otsr.2018.06.014","volume":"104","author":"M Lleu","year":"2018","unstructured":"Lleu M, Charles YP, Blondel B, Barresi L, Nicot B, Challier V, Godard J, Kouyoumdjian P, Lonjon N, Marinho P, Freitas E, Schuller S, Fuentes S, Allia J, Berthiller J, Barrey C. C1 fracture: analysis of consolidation and complications rates in a prospective multicenter series. Orthop Traumatol Surg Res. 2018;104:1049\u201354.","journal-title":"Orthop Traumatol Surg Res"},{"key":"3575_CR14","first-page":"335","volume":"8","author":"Y Kamal","year":"2014","unstructured":"Kamal Y, Ortho MS, Khan HA, Gani N, Haq AU, Gul S, Singh D. Atlas and axis injuries role of Halovest. Int J Health Sci (Qassim). 2014;8:335\u201345.","journal-title":"Int J Health Sci (Qassim)"},{"key":"3575_CR15","doi-asserted-by":"publisher","first-page":"411","DOI":"10.3171\/spi.2005.2.4.0411","volume":"2","author":"MF Dvorak","year":"2005","unstructured":"Dvorak MF, Johnson MG, Boyd M, Johnson G, Kwon BK, Fisher CG. Long-term health-related quality of life outcomes following Jefferson-type burst fractures of the atlas. J Neurosurg Spine. 2005;2:411\u20137.","journal-title":"J Neurosurg Spine"},{"key":"3575_CR16","doi-asserted-by":"publisher","first-page":"46","DOI":"10.3171\/spi.2006.5.1.46","volume":"5","author":"EM Horn","year":"2006","unstructured":"Horn EM, Theodore N, Feiz-Erfan I, Lekovic GP, Dickman CA, Sonntag VK. Complications of halo fixation in the elderly. J Neurosurg Spine. 2006;5:46\u20139.","journal-title":"J Neurosurg Spine"},{"key":"3575_CR17","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1055\/s-0034-1543967","volume":"76","author":"S Kukreja","year":"2015","unstructured":"Kukreja S, Ambekar S, Sin AH, Nanda A. Occipitocervical fusion surgery: review of operative techniques and results. J Neurol Surg B Skull Base. 2015;76:331\u20139.","journal-title":"J Neurol Surg B Skull Base"},{"key":"3575_CR18","doi-asserted-by":"publisher","first-page":"2271","DOI":"10.1016\/j.spinee.2015.07.008","volume":"15","author":"DG Huang","year":"2015","unstructured":"Huang DG, Hao DJ, He BR, Wu QN, Liu TJ, Wang XD, Guo H, Fang XY. Posterior atlantoaxial fixation: a review of all techniques. Spine J. 2015;15:2271\u201381.","journal-title":"Spine J"},{"key":"3575_CR19","doi-asserted-by":"publisher","first-page":"E401","DOI":"10.1097\/BRS.0b013e31820611ba","volume":"36","author":"HB Sim","year":"2011","unstructured":"Sim HB, Lee JW, Park JT, Mindea SA, Lim J, Park J. Biomechanical evaluations of various c1-c2 posterior fixation techniques. Spine (Phila Pa 1976). 2011;36:E401\u20137.","journal-title":"Spine (Phila Pa 1976)"},{"key":"3575_CR20","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1097\/00002517-200106000-00001","volume":"14","author":"CE Sutterlin","year":"2001","unstructured":"Sutterlin CE, Bianchi JR, Kunz DN, Zdeblick TA, Johnson WM, Rapoff AJ. Biomechanical evaluation of occipitocervical fixation devices. J Spinal Disord. 2001;14:185\u201392.","journal-title":"J Spinal Disord"},{"issue":"Suppl 2","key":"3575_CR21","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1227\/NEU.0b013e318276ee2a","volume":"72","author":"TC Ryken","year":"2013","unstructured":"Ryken TC, Aarabi B, Dhall SS, Gelb DE, Hurlbert RJ, Rozzelle CJ, Theodore N, Walters BC, Hadley MN. Management of isolated fractures of the atlas in adults. Neurosurgery. 2013;72(Suppl 2):127\u201331.","journal-title":"Neurosurgery"},{"key":"3575_CR22","doi-asserted-by":"publisher","first-page":"1187","DOI":"10.1007\/s00701-002-0998-2","volume":"144","author":"C Hein","year":"2002","unstructured":"Hein C, Richter HP, Rath SA. Atlantoaxial screw fixation for the treatment of isolated and combined unstable Jefferson fractures\u2013experiences with 8 patients. Acta Neurochir (Wien). 2002;144:1187\u201392.","journal-title":"Acta Neurochir (Wien)"},{"issue":"19","key":"3575_CR23","first-page":"2196","volume":"29","author":"C Dickman","year":"2004","unstructured":"Dickman C. Re: Ruf M, Melcher R, Harms J. Transoral reduction and osteosynthesis C1 as a function-preserving option in the treatment of unstable Jefferson fractures. Spine (Phila Pa 1976). 2004; 29:823\u2013827. Spine (Phila Pa 1976). 2004;29(19):2196\u20137.","journal-title":"Spine (Phila Pa 1976)"},{"key":"3575_CR24","doi-asserted-by":"publisher","first-page":"1288","DOI":"10.1007\/s00586-010-1380-3","volume":"19","author":"H Koller","year":"2010","unstructured":"Koller H, Resch H, Tauber M, Zenner J, Augat P, Penzkofer R, Acosta F, Kolb K, Kathrein A, Hitzl W. A biomechanical rationale for C1-ring osteosynthesis as treatment for displaced Jefferson burst fractures with incompetency of the transverse atlantal ligament. Eur Spine J. 2010;19:1288\u201398.","journal-title":"Eur Spine J"},{"key":"3575_CR25","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1038\/sc.2014.8","volume":"52","author":"L Li-Jun","year":"2014","unstructured":"Li-Jun L, Ying-Chao H, Ming-Jie Y, Jie P, Jun T, Dong-Sheng Z. Biomechanical analysis of the longitudinal ligament of upper cervical spine in maintaining atlantoaxial stability. Spinal Cord. 2014;52:342\u20137.","journal-title":"Spinal Cord"},{"key":"3575_CR26","doi-asserted-by":"publisher","first-page":"2892","DOI":"10.1016\/j.spinee.2014.04.020","volume":"14","author":"B He","year":"2014","unstructured":"He B, Yan L, Zhao Q, Chang Z, Hao D. Self-designed posterior atlas polyaxial lateral mass screw-plate fixation for unstable atlas fracture. Spine J. 2014;14:2892\u20136.","journal-title":"Spine J"},{"key":"3575_CR27","doi-asserted-by":"publisher","first-page":"E1046","DOI":"10.1097\/BRS.0b013e3181fef78c","volume":"36","author":"L Li","year":"2011","unstructured":"Li L, Teng H, Pan J, Qian L, Zeng C, Sun G, Yang M, Tan J. Direct posterior C1 lateral mass screws compression reduction and osteosynthesis in the treatment of unstable jefferson fractures. Spine (Phila Pa 1976). 2011;36:E1046\u201351.","journal-title":"Spine (Phila Pa 1976)"},{"key":"3575_CR28","doi-asserted-by":"publisher","first-page":"E1151","DOI":"10.1097\/BRS.0000000000001593","volume":"41","author":"QS Yin","year":"2016","unstructured":"Yin QS, Li XS, Bai ZH, Mai XH, Xia H, Wu ZH, Ma XY, Ai FZ, Wang JH, Zhang K. An 11-year review of the TARP procedure in the treatment of atlantoaxial dislocation. Spine (Phila Pa 1976). 2016;41:E1151\u20138.","journal-title":"Spine (Phila Pa 1976)"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-020-03575-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-020-03575-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-020-03575-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,11]],"date-time":"2021-08-11T19:33:40Z","timestamp":1628710420000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-020-03575-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,12]]},"references-count":28,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["3575"],"URL":"https:\/\/doi.org\/10.1186\/s12891-020-03575-w","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-26619\/v1","asserted-by":"object"}]},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8,12]]},"assertion":[{"value":"29 April 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 August 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 August 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was approved by the ethics committee of General Hospital of Southern Theatre Command of PLA and the written informed consent for participation in the study was obtained.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent was obtained from all individual participants included in the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"538"}}