{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T11:14:34Z","timestamp":1791285274999,"version":"4.1.0"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,10,22]],"date-time":"2020-10-22T00:00:00Z","timestamp":1603324800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,10,22]],"date-time":"2020-10-22T00:00:00Z","timestamp":1603324800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"This publication was supported by the Open Access Publication Fund of the University of W\u00fcrzburg."}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Background<\/jats:title>\n<jats:p>For improved outcomes in total knee arthroplasty (TKA) correct implant fitting and positioning are crucial. In order to facilitate a best possible implant fitting and positioning patient-specific systems have been developed. However, whether or not these systems allow for better implant fitting and positioning has yet to be elucidated. For this reason, the aim was to analyse the novel patient-specific cruciate retaining knee replacement system iTotal\u2122 CR G2 that utilizes custom-made implants and instruments for its ability to facilitate accurate implant fitting and positioning including correction of the hip-knee-ankle angle (HKA).<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>We assessed radiographic results of 106 patients who were treated with the second generation of a patient-specific cruciate retaining knee arthroplasty using iTotal\u2122 CR G2 (ConforMIS Inc.) for tricompartmental knee osteoarthritis (OA) using custom-made implants and instruments. The implant fit and positioning as well as the correction of the mechanical axis (hip-knee-ankle angle, HKA) and restoration of the joint line were determined using pre- and postoperative radiographic analyses.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>On average, HKA was corrected from 174.4\u00b0\u2009\u00b1\u20094.6\u00b0 preoperatively to 178.8\u00b0\u2009\u00b1\u20092.2\u00b0 postoperatively and the coronal femoro-tibial angle was adjusted on average 4.4\u00b0. The measured preoperative tibial slope was 5.3\u00b0\u2009\u00b1\u20092.2\u00b0 (mean +\/\u2212 SD) and the average postoperative tibial slope was 4.7\u00b0\u2009\u00b1\u20091.1\u00b0 on lateral views. The joint line was well preserved with an average modified Insall-Salvati index of 1.66\u2009\u00b1\u20090.16 pre- and 1.67\u2009\u00b1\u20090.16 postoperatively. The overall accuracy of fit of implant components was decent with a measured medial overhang of more than 1\u2009mm (1.33\u2009mm\u2009\u00b1\u20090.32\u2009mm) in 4 cases only. Further, a lateral overhang of more than 1\u2009mm (1.8\u2009mm\u2009\u00b1\u20090.63) (measured in the anterior-posterior radiographs) was observed in 11 cases, with none of the 106 patients showing femoral notching.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusion<\/jats:title>\n<jats:p>The patient-specific iTotal\u2122 CR G2 total knee replacement system facilitated a proper fitting and positioning of the implant components. Moreover, a good restoration of the leg axis towards neutral alignment was achieved as planned. Nonetheless, further clinical follow-up studies are necessary to validate our findings and to determine the long-term impact of using this patient- specific system.<\/jats:p>\n<\/jats:sec>","DOI":"10.1186\/s12891-020-03707-2","type":"journal-article","created":{"date-parts":[[2020,10,22]],"date-time":"2020-10-22T14:03:00Z","timestamp":1603375380000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Accurate implant fit and leg alignment after cruciate-retaining patient-specific total knee arthroplasty"],"prefix":"10.1186","volume":"21","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4930-2611","authenticated-orcid":false,"given":"J\u00f6rg","family":"Arnholdt","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yama","family":"Kamawal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Konstantin","family":"Horas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Boris M.","family":"Holzapfel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabian","family":"Gilbert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Axel","family":"Ripp","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maximilian","family":"Rudert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andre F.","family":"Steinert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,10,22]]},"reference":[{"issue":"1","key":"3707_CR1","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1007\/s11999-009-1119-9","volume":"468","author":"RB Bourne","year":"2010","unstructured":"Bourne RB, Chesworth BM, Davis AM, Mahomed NN, Charron KD. Patient satisfaction after total knee arthroplasty: who is satisfied and who is not? Clin Orthop Relat Res. 2010;468(1):57\u201363.","journal-title":"Clin Orthop Relat Res"},{"issue":"5","key":"3707_CR2","doi-asserted-by":"crossref","first-page":"1115","DOI":"10.2106\/JBJS.H.00434","volume":"92","author":"OM Mahoney","year":"2010","unstructured":"Mahoney OM, Kinsey T. Overhang of the femoral component in total knee arthroplasty: risk factors and clinical consequences. J Bone Joint Surg Am. 2010;92(5):1115\u201321.","journal-title":"J Bone Joint Surg Am"},{"key":"3707_CR3","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1097\/01.blo.0000148578.22729.0e","volume":"428","author":"ME Berend","year":"2004","unstructured":"Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, Faris GW, Davis KE. Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res. 2004;428:26\u201334.","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"3707_CR4","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1016\/j.arth.2008.03.002","volume":"24","author":"LM Longstaff","year":"2009","unstructured":"Longstaff LM, Sloan K, Stamp N, Scaddan M, Beaver R. Good alignment after total knee arthroplasty leads to faster rehabilitation and better function. J Arthroplast. 2009;24(4):570\u20138.","journal-title":"J Arthroplast"},{"issue":"1","key":"3707_CR5","doi-asserted-by":"crossref","first-page":"835","DOI":"10.1186\/s40064-015-1604-4","volume":"4","author":"M Hadi","year":"2015","unstructured":"Hadi M, Barlow T, Ahmed I, Dunbar M, McCulloch P, Griffin D. Does malalignment affect revision rate in total knee replacements: a systematic review of the literature. SpringerPlus. 2015;4(1):835.","journal-title":"SpringerPlus"},{"issue":"5","key":"3707_CR6","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1016\/j.knee.2010.06.008","volume":"18","author":"FX Koeck","year":"2011","unstructured":"Koeck FX, Beckmann J, Luring C, Rath B, Grifka J, Basad E. Evaluation of implant position and knee alignment after patient-specific unicompartmental knee arthroplasty. Knee. 2011;18(5):294\u20139.","journal-title":"Knee"},{"key":"3707_CR7","doi-asserted-by":"crossref","unstructured":"Arnholdt J, Holzapfel BM, Sefrin L, Rudert M, Beckmann J, Steinert AF. [Individualized unicondylar knee replacement : use of patient-specific implants and instruments]. Oper Orthop Traumatol 2017;29(1):31\u201339.","DOI":"10.1007\/s00064-017-0485-9"},{"issue":"6","key":"3707_CR8","doi-asserted-by":"crossref","first-page":"1424","DOI":"10.5114\/aoms.2018.79007","volume":"14","author":"J Arnholdt","year":"2018","unstructured":"Arnholdt J, Kamawal Y, Holzapfel BM, Ripp A, Rudert M, Steinert AF. Evaluation of implant fit and frontal plane alignment after bi-compartmental knee arthroplasty using patient-specific instruments and implants. Arch Med Sci. 2018;14(6):1424\u201331.","journal-title":"Arch Med Sci"},{"issue":"1","key":"3707_CR9","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1007\/s00064-017-0484-x","volume":"29","author":"AF Steinert","year":"2017","unstructured":"Steinert AF, Beckmann J, Holzapfel BM, Rudert M, Arnholdt J. Bicompartmental individualized knee replacement : use of patient-specific implants and instruments (iDuo). Oper Orthop Traumatol. 2017;29(1):51\u20138.","journal-title":"Oper Orthop Traumatol"},{"key":"3707_CR10","doi-asserted-by":"crossref","unstructured":"Steinert AF, Sefrin L, Hoberg M, Arnholdt J, Rudert M. [Individualized total knee arthroplasty]. Orthopade 2015;44(4):290\u2013292, 294-301.","DOI":"10.1007\/s00132-015-3104-1"},{"issue":"8","key":"3707_CR11","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.1007\/s00264-015-2678-x","volume":"39","author":"MK Demange","year":"2015","unstructured":"Demange MK, Von Keudell A, Probst C, Yoshioka H, Gomoll AH. Patient-specific implants for lateral unicompartmental knee arthroplasty. Int Orthop. 2015;39(8):1519\u201326.","journal-title":"Int Orthop"},{"key":"3707_CR12","doi-asserted-by":"crossref","unstructured":"Pfitzner T, Perka C, Matziolis G. [Patella height after total knee replacement: influence of the radiological setting]. Orthopade 2009;38(7):616\u2013621.","DOI":"10.1007\/s00132-009-1437-3"},{"key":"3707_CR13","doi-asserted-by":"crossref","unstructured":"Springorum HR, Baier C, Craiovan B, Maderbacher G, Renkawitz T, Grifka J, Keshmiri A. [Patella navigation in computer-assisted TKA : intraoperative measurement of patellar kinematics. Video article]. Orthopade 2016;45(7):569\u2013572.","DOI":"10.1007\/s00132-016-3285-2"},{"issue":"5","key":"3707_CR14","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1016\/j.knee.2007.06.006","volume":"14","author":"PJ Heesterbeek","year":"2007","unstructured":"Heesterbeek PJ, Beumers MP, Jacobs WC, Havinga ME, Wymenga AB. A comparison of reproducibility of measurement techniques for patella position on axial radiographs after total knee arthroplasty. Knee. 2007;14(5):411\u20136.","journal-title":"Knee"},{"issue":"1","key":"3707_CR15","doi-asserted-by":"crossref","first-page":"1","DOI":"10.5792\/ksrr.2016.28.1.1","volume":"28","author":"YJ Choi","year":"2016","unstructured":"Choi YJ, Ra HJ. Patient satisfaction after total knee arthroplasty. Knee Surg Relat Res. 2016;28(1):1\u201315.","journal-title":"Knee Surg Relat Res"},{"issue":"4","key":"3707_CR16","doi-asserted-by":"crossref","first-page":"1083","DOI":"10.1007\/s00167-018-5256-0","volume":"27","author":"S Gong","year":"2019","unstructured":"Gong S, Xu W, Wang R, Wang Z, Wang B, Han L, Chen G. Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2019;27(4):1083\u201395.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"7","key":"3707_CR17","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1080\/17434440.2019.1627197","volume":"16","author":"VJ Le\u00f3n-Mu\u00f1oz","year":"2019","unstructured":"Le\u00f3n-Mu\u00f1oz VJ, Mart\u00ednez-Mart\u00ednez F, L\u00f3pez-L\u00f3pez M, Santonja-Medina F. Patient-specific instrumentation in total knee arthroplasty. Expert Rev Med Devices. 2019;16(7):555\u201367.","journal-title":"Expert Rev Med Devices"},{"issue":"2","key":"3707_CR18","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/j.arth.2012.05.019","volume":"28","author":"R Gudena","year":"2013","unstructured":"Gudena R, Pilambaraei MA, Werle J, Shrive NG, Frank CB. A safe overhang limit for unicompartmental knee arthroplasties based on medial collateral ligament strains: an in vitro study. J Arthroplast. 2013;28(2):227\u201333.","journal-title":"J Arthroplast"},{"issue":"5","key":"3707_CR19","doi-asserted-by":"crossref","first-page":"1394","DOI":"10.1016\/j.arth.2017.12.027","volume":"33","author":"CS Nielsen","year":"2018","unstructured":"Nielsen CS, Nebergall A, Huddleston J, Kallemose T, Malchau H, Troelsen A. Medial overhang of the tibial component is associated with higher risk of inferior knee injury and osteoarthritis outcome score pain after knee replacement. J Arthroplast. 2018;33(5):1394\u20138.","journal-title":"J Arthroplast"},{"issue":"9","key":"3707_CR20","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1302\/0301-620X.90B9.20793","volume":"90","author":"JM Sikorski","year":"2008","unstructured":"Sikorski JM. Alignment in total knee replacement. J Bone Joint Surg (Br). 2008;90(9):1121\u20137.","journal-title":"J Bone Joint Surg (Br)"},{"issue":"6","key":"3707_CR21","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1016\/S0883-5403(97)90141-8","volume":"12","author":"SC Reed","year":"1997","unstructured":"Reed SC, Gollish J. The accuracy of femoral intramedullary guides in total knee arthroplasty. J Arthroplast. 1997;12(6):677\u201382.","journal-title":"J Arthroplast"},{"key":"3707_CR22","first-page":"117","volume":"321","author":"KE Teter","year":"1995","unstructured":"Teter KE, Bregman D, Colwell CW Jr. The efficacy of intramedullary femoral alignment in total knee replacement. Clin Orthop Relat Res. 1995;321:117\u201321.","journal-title":"Clin Orthop Relat Res"},{"issue":"5","key":"3707_CR23","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1016\/0141-5425(92)90080-5","volume":"14","author":"MA Elloy","year":"1992","unstructured":"Elloy MA, Manning MP, Johnson R. Accuracy of intramedullary alignment in total knee replacement. J Biomed Eng. 1992;14(5):363\u201370.","journal-title":"J Biomed Eng"},{"issue":"15","key":"3707_CR24","doi-asserted-by":"crossref","first-page":"1377","DOI":"10.2106\/JBJS.I.01321","volume":"93","author":"WG Blakeney","year":"2011","unstructured":"Blakeney WG, Khan RJ, Wall SJ. Computer-assisted techniques versus conventional guides for component alignment in total knee arthroplasty: a randomized controlled trial. J Bone Joint Surg Am. 2011;93(15):1377\u201384.","journal-title":"J Bone Joint Surg Am"},{"issue":"6","key":"3707_CR25","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1503\/cjs.018318","volume":"62","author":"TR Turgeon","year":"2019","unstructured":"Turgeon TR, Cameron B, Burnell CD, Hedden DR, Bohm ER. A double-blind randomized controlled trial of total knee replacement using patient-specific cutting block instrumentation versus standard instrumentation. Can J Surg. 2019;62(6):460\u20137.","journal-title":"Can J Surg"},{"issue":"5","key":"3707_CR26","first-page":"283","volume":"5","author":"DN Lyras","year":"2017","unstructured":"Lyras DN, Greenhow R, Loucks C. Restoration of the mechanical axis in total knee artrhoplasty using patient-matched technology cutting blocks. A retrospective study of 132 cases. Arch Bone Jt Surg. 2017;5(5):283\u20139.","journal-title":"Arch Bone Jt Surg"},{"issue":"3","key":"3707_CR27","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1007\/s00402-012-1667-4","volume":"133","author":"CO Tibesku","year":"2013","unstructured":"Tibesku CO, Hofer P, Portegies W, Ruys CJ, Fennema P. Benefits of using customized instrumentation in total knee arthroplasty: results from an activity-based costing model. Arch Orthop Trauma Surg. 2013;133(3):405\u201311.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"2","key":"3707_CR28","first-page":"112","volume":"20","author":"TS Watters","year":"2011","unstructured":"Watters TS, Mather RC 3rd, Browne JA, Berend KR, Lombardi AV Jr, Bolognesi MP. Analysis of procedure-related costs and proposed benefits of using patient-specific approach in total knee arthroplasty. J Surg Orthop Adv. 2011;20(2):112\u20136.","journal-title":"J Surg Orthop Adv"},{"issue":"3","key":"3707_CR29","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1302\/0301-620X.95B3.29903","volume":"95-B","author":"K Chareancholvanich","year":"2013","unstructured":"Chareancholvanich K, Narkbunnam R, Pornrattanamaneewong C. A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement. Bone Joint J. 2013;95-B(3):354\u20139.","journal-title":"Bone Joint J"},{"issue":"2","key":"3707_CR30","doi-asserted-by":"crossref","first-page":"e160","DOI":"10.3928\/01477447-20120123-04","volume":"35","author":"HG Dossett","year":"2012","unstructured":"Dossett HG, Swartz GJ, Estrada NA, LeFevre GW, Kwasman BG. Kinematically versus mechanically aligned total knee arthroplasty. Orthopedics. 2012;35(2):e160\u20139.","journal-title":"Orthopedics"},{"issue":"10","key":"3707_CR31","doi-asserted-by":"crossref","first-page":"2037","DOI":"10.1007\/s00264-017-3509-z","volume":"41","author":"C Baier","year":"2017","unstructured":"Baier C, Wolfsteiner J, Otto F, Zeman F, Renkawitz T, Springorum HR, Maderbacher G, Grifka J. Clinical, radiological and survivorship results after ten years comparing navigated and conventional total knee arthroplasty: a matched-pair analysis. Int Orthop. 2017;41(10):2037\u201344.","journal-title":"Int Orthop"},{"issue":"1","key":"3707_CR32","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1007\/s11999-012-2528-8","volume":"471","author":"RS Burnett","year":"2013","unstructured":"Burnett RS, Barrack RL. Computer-assisted total knee arthroplasty is currently of no proven clinical benefit: a systematic review. Clin Orthop Relat Res. 2013;471(1):264\u201376.","journal-title":"Clin Orthop Relat Res"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-020-03707-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-020-03707-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-020-03707-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,21]],"date-time":"2021-10-21T23:23:31Z","timestamp":1634858611000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-020-03707-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10,22]]},"references-count":32,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["3707"],"URL":"https:\/\/doi.org\/10.1186\/s12891-020-03707-2","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,10,22]]},"assertion":[{"value":"24 April 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 October 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 October 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 November 2020","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Update","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The patients serial number in Figure 1 that the author requested to remove during corrections stage was not implemented.","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This retrospective study was performed at the Department of Orthopaedic Surgery, University of Wuerzburg, Wuerzburg, Germany. The approval for this study was waived by the University\u2019s ethics committee \u201cEthik-Komission der Universit\u00e4t W\u00fcrzburg\u201d on the 17th of October 2016 (approval number 2016101401).","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"No benefits in any form have been received or will be received from a commercial party related, directly or indirectly, to the subject of this article. Moreover, the authors have full control of all primary data and will agree to allow the journal to review the data if requested. AFS and AR are teaching consultants for ConforMIS Inc. MR received institutional support for training activities.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"699"}}