{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T20:25:52Z","timestamp":1792268752804,"version":"4.4.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,1,9]],"date-time":"2021-01-09T00:00:00Z","timestamp":1610150400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2021,1,9]],"date-time":"2021-01-09T00:00:00Z","timestamp":1610150400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>No studies to date have elucidated the clinical factors associated with pedicle screw pull-out during or immediately after surgery. The aim of this study was to assess the frequency of pedicle screw pull-out by comparing intraoperative scans obtained using cone-beam computed tomography (CBCT) with postoperative scans obtained using computed tomography (CT). We also sought to determine the incidence of pedicle screw pull-out and identify relevant risk factors.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>This was a retrospective analysis of prospectively collected data for 742 pedicle screws placed in 76 consecutive patients who underwent at least triple-level posterior fixation for thoracic or lumbar spinal injury, spinal metastasis, or pyogenic spondylitis between April 2014 and July 2020. Pedicle screw pull-out distance in the axial and sagittal planes was compared between CT scans obtained 2 days postoperatively and CBCT images acquired intraoperatively. Risk factors associated with pedicle screw pull-out were investigated by multivariate logistic regression analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Pedicle screw pull-out was seen with 58 pedicle screws (7.8%) in 26 patients (34.2%). There were significant differences in age, number of fused segments, frequency of diffuse idiopathic skeletal hyperostosis (DISH), and medical history of osteoporosis for pedicle screw pull-out. Risk factors for pedicle screw pull-out were older age (odds ratio 1.07, 95% confidence interval 1.02\u20131.130) and a diagnosis of DISH (odds ratio 3.35, 95% confidence interval 1.12\u201310.00). Several cases suggest that use of connecting rods was an important factor in intraoperative pedicle screw pull-out.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Our findings suggest that age, number of fused segments, presence of DISH, and medical history of osteoporosis are risk factors for pedicle screw pull-out, with the greatest being older age and DISH.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12891-020-03916-9","type":"journal-article","created":{"date-parts":[[2021,1,9]],"date-time":"2021-01-09T09:03:45Z","timestamp":1610183025000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Comparative analysis of clinical factors associated with pedicle screw pull\u2010out during or immediately after surgery between intraoperative cone\u2010beam computed tomography and postoperative computed tomography"],"prefix":"10.1186","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2700-9860","authenticated-orcid":false,"given":"Satoshi","family":"Sumiya","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazuyuki","family":"Fukushima","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshiro","family":"Kurosa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takashi","family":"Hirai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyuki","family":"Inose","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshitaka","family":"Yoshii","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Atsushi","family":"Okawa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,1,9]]},"reference":[{"key":"3916_CR1","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1007\/s00586-011-2011-3","volume":"21","author":"ID Gelalis","year":"2012","unstructured":"Gelalis ID, Paschos NK, Pakos EE, Politis AN, Arnaoutoglou CM, Karageorgos AC, Ploumis A, Xenakis TA. Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. European spine journal: official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical. Spine Research Society. 2012;21:247\u201355. doi:https:\/\/doi.org\/10.1007\/s00586-011-2011-3.","journal-title":"Spine Research Society"},{"key":"3916_CR2","doi-asserted-by":"publisher","first-page":"E465","DOI":"10.1097\/BRS.0b013e3181d1021a","volume":"35","author":"JM Hicks","year":"2010","unstructured":"Hicks JM, Singla A, Shen FH, Arlet V. Complications of pedicle screw fixation in scoliosis surgery: a systematic review. Spine. 2010;35:E465\u201370. doi:https:\/\/doi.org\/10.1097\/BRS.0b013e3181d1021a.","journal-title":"Spine"},{"key":"3916_CR3","doi-asserted-by":"publisher","first-page":"304","DOI":"10.3171\/spi.2006.4.4.304","volume":"4","author":"S Okuda","year":"2006","unstructured":"Okuda S, Miyauchi A, Oda T, Haku T, Yamamoto T, Iwasaki M. Surgical complications of posterior lumbar interbody fusion with total facetectomy in 251 patients. Journal of neurosurgery Spine. 2006;4:304\u20139. doi:https:\/\/doi.org\/10.3171\/spi.2006.4.4.304.","journal-title":"Journal of neurosurgery Spine"},{"key":"3916_CR4","doi-asserted-by":"publisher","first-page":"594","DOI":"10.1007\/s00586-002-0469-8","volume":"11","author":"PC Jutte","year":"2002","unstructured":"Jutte PC, Castelein RM. Complications of pedicle screws in lumbar and lumbosacral fusions in 105 consecutive primary operations. European spine journal: official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical. Spine Research Society. 2002;11:594\u20138. doi:https:\/\/doi.org\/10.1007\/s00586-002-0469-8.","journal-title":"Spine Research Society"},{"key":"3916_CR5","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1016\/j.spinee.2014.07.017","volume":"15","author":"DG Kang","year":"2015","unstructured":"Kang DG, Lehman RA Jr, Wagner SC, Bevevino AJ, Tracey RW, Gaume RE, Dmitriev AE. Effects of rod reduction on pedicle screw fixation strength in the setting of Ponte osteotomies. The spine journal: official journal of the North American Spine Society. 2015;15:146\u201352. doi:https:\/\/doi.org\/10.1016\/j.spinee.2014.07.017.","journal-title":"The spine journal: official journal of the North American Spine Society"},{"key":"3916_CR6","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1007\/s10143-018-0977-6","volume":"42","author":"CA Bohoun","year":"2019","unstructured":"Bohoun CA, Naito K, Yamagata T, Tamrakar S, Ohata K, Takami T. Safety and accuracy of spinal instrumentation surgery in a hybrid operating room with an intraoperative cone-beam computed tomography. Neurosurgical review. 2019;42:417\u201326. doi:https:\/\/doi.org\/10.1007\/s10143-018-0977-6.","journal-title":"Neurosurgical review"},{"key":"3916_CR7","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1016\/j.wneu.2017.08.149","volume":"108","author":"E Fomekong","year":"2017","unstructured":"Fomekong E, Safi SE, Raftopoulos C. Spine Navigation Based on 3-Dimensional Robotic Fluoroscopy for Accurate Percutaneous Pedicle Screw Placement: A Prospective Study of 66 Consecutive Cases. World neurosurgery. 2017;108:76\u201383. doi:https:\/\/doi.org\/10.1016\/j.wneu.2017.08.149.","journal-title":"World neurosurgery"},{"key":"3916_CR8","doi-asserted-by":"publisher","first-page":"E1463","DOI":"10.1097\/BRS.0000000000002737","volume":"43","author":"H Oba","year":"2018","unstructured":"Oba H, Ebata S, Takahashi J, Koyama K, Uehara M, Kato H, Haro H, Ohba T. Pedicle Perforation While Inserting Screws Using O-arm Navigation During Surgery for Adolescent Idiopathic Scoliosis: Risk Factors and Effect of Insertion Order. Spine. 2018;43:E1463\u20138. doi:https:\/\/doi.org\/10.1097\/BRS.0000000000002737.","journal-title":"Spine"},{"key":"3916_CR9","doi-asserted-by":"publisher","first-page":"765","DOI":"10.1016\/j.jos.2018.05.007","volume":"23","author":"T Kotani","year":"2018","unstructured":"Kotani T, Akazawa T, Sakuma T, Nakayama K, Kishida S, Muramatsu Y, Sasaki Y, Ueno K, Iijima Y, Minami S, Ohtori S. Accuracy of powered surgical instruments compared with manual instruments for pedicle screw insertion: Evaluation using o-arm-based navigation in scoliosis surgery. Journal of orthopaedic science: official journal of the Japanese Orthopaedic Association. 2018;23:765\u20139. doi:https:\/\/doi.org\/10.1016\/j.jos.2018.05.007.","journal-title":"Journal of orthopaedic science: official journal of the Japanese Orthopaedic Association"},{"key":"3916_CR10","doi-asserted-by":"publisher","first-page":"79","DOI":"10.22603\/ssrr.2018-0018","volume":"3","author":"T Ohba","year":"2019","unstructured":"Ohba T, Ebata S, Oba H, Koyama K, Haro H. Risk Factors for Clinically Relevant Loosening of Percutaneous Pedicle Screws. Spine Surg Relat Res. 2019;3:79\u201385. doi:https:\/\/doi.org\/10.22603\/ssrr.2018-0018.","journal-title":"Spine Surg Relat Res"},{"key":"3916_CR11","doi-asserted-by":"publisher","first-page":"230949901984340","DOI":"10.1177\/2309499019843407","volume":"27","author":"E Okada","year":"2019","unstructured":"Okada E, Shiono Y, Nishida M, Mima Y, Funao H, Shimizu K, Kato M, Fukuda K, Fujita N, Yagi M, Nagoshi N, Tsuji O, Ishii K, Nakamura M, Matsumoto M, Watanabe K. Spinal fractures in diffuse idiopathic skeletal hyperostosis: Advantages of percutaneous pedicle screw fixation. J Orthop Surg (Hong Kong). 2019;27:2309499019843407. doi:https:\/\/doi.org\/10.1177\/2309499019843407.","journal-title":"J Orthop Surg (Hong Kong)"},{"key":"3916_CR12","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1007\/s00586-006-0221-x","volume":"16","author":"C Schizas","year":"2007","unstructured":"Schizas C, Michel J, Kosmopoulos V, Theumann N. Computer tomography assessment of pedicle screw insertion in percutaneous posterior transpedicular stabilization. European spine journal: official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical. Spine Research Society. 2007;16:613\u20137. doi:https:\/\/doi.org\/10.1007\/s00586-006-0221-x.","journal-title":"Spine Research Society"},{"key":"3916_CR13","doi-asserted-by":"publisher","first-page":"1005","DOI":"10.1007\/s00586-015-3768-6","volume":"24","author":"F Galbusera","year":"2015","unstructured":"Galbusera F, Volkheimer D, Reitmaier S, Berger-Roscher N, Kienle A, Wilke HJ. Pedicle screw loosening: a clinically relevant complication? European spine journal: official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical. Spine Research Society. 2015;24:1005\u201316. doi:https:\/\/doi.org\/10.1007\/s00586-015-3768-6.","journal-title":"Spine Research Society"},{"key":"3916_CR14","doi-asserted-by":"publisher","first-page":"1063","DOI":"10.1007\/s00402-016-2487-8","volume":"136","author":"J Bredow","year":"2016","unstructured":"Bredow J, Boese CK, Werner CM, Siewe J, Lohrer L, Zarghooni K, Eysel P, Scheyerer MJ. Predictive validity of preoperative CT scans and the risk of pedicle screw loosening in spinal surgery. Arch Orthop Trauma Surg. 2016;136:1063\u20137. doi:https:\/\/doi.org\/10.1007\/s00402-016-2487-8.","journal-title":"Arch Orthop Trauma Surg"},{"key":"3916_CR15","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1007\/s00402-011-1439-6","volume":"132","author":"ZX Wu","year":"2012","unstructured":"Wu ZX, Gong FT, Liu L, Ma ZS, Zhang Y, Zhao X, Yang M, Lei W, Sang HX. A comparative study on screw loosening in osteoporotic lumbar spine fusion between expandable and conventional pedicle screws. Arch Orthop Trauma Surg. 2012;132:471\u20136. doi:https:\/\/doi.org\/10.1007\/s00402-011-1439-6.","journal-title":"Arch Orthop Trauma Surg"},{"key":"3916_CR16","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1148\/15.3.513","volume":"115","author":"D Resnick","year":"1975","unstructured":"Resnick D, Shaul SR, Robins JM. Diffuse idiopathic skeletal hyperostosis (DISH): Forestier\u2019s disease with extraspinal manifestations. Radiology. 1975;115:513\u201324. doi:https:\/\/doi.org\/10.1148\/15.3.513.","journal-title":"Radiology"},{"key":"3916_CR17","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1148\/119.3.559","volume":"119","author":"D Resnick","year":"1976","unstructured":"Resnick D, Niwayama G. Radiographic and pathologic features of spinal involvement in diffuse idiopathic skeletal hyperostosis (DISH). Radiology. 1976;119:559\u201368. doi:https:\/\/doi.org\/10.1148\/119.3.559.","journal-title":"Radiology"},{"key":"3916_CR18","doi-asserted-by":"publisher","first-page":"1133","DOI":"10.1093\/rheumatology\/kep177","volume":"48","author":"LA Westerveld","year":"2009","unstructured":"Westerveld LA, Verlaan JJ, Lam MG, Scholten WP, Bleys RL, Dhert WJ, Oner FC. The influence of diffuse idiopathic skeletal hyperostosis on bone mineral density measurements of the spine. Rheumatology. 2009;48:1133\u20136. doi:https:\/\/doi.org\/10.1093\/rheumatology\/kep177.","journal-title":"Rheumatology"},{"key":"3916_CR19","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1007\/s00774-014-0583-9","volume":"33","author":"R Kagotani","year":"2015","unstructured":"Kagotani R, Yoshida M, Muraki S, Oka H, Hashizume H, Yamada H, Enyo Y, Nagata K, Ishimoto Y, Teraguchi M, Tanaka S, Nakamura K, Kawaguchi H, Akune T, Yoshimura N. Prevalence of diffuse idiopathic skeletal hyperostosis (DISH) of the whole spine and its association with lumbar spondylosis and knee osteoarthritis: the ROAD study. J Bone Miner Metab. 2015;33:221\u20139. doi:https:\/\/doi.org\/10.1007\/s00774-014-0583-9.","journal-title":"J Bone Miner Metab"},{"key":"3916_CR20","first-page":"2032","volume":"31","author":"SK Kim","year":"2004","unstructured":"Kim SK, Choi BR, Kim CG, Chung SH, Choe JY, Joo KB, Bae SC, Yoo DH, Jun JB. The prevalence of diffuse idiopathic skeletal hyperostosis in Korea. J Rheumatol. 2004;31:2032\u20135.","journal-title":"J Rheumatol"},{"key":"3916_CR21","doi-asserted-by":"publisher","first-page":"E458","DOI":"10.1097\/BRS.0b013e3181cc764f","volume":"35","author":"T Caron","year":"2010","unstructured":"Caron T, Bransford R, Nguyen Q, Agel J, Chapman J, Bellabarba C. Spine fractures in patients with ankylosing spinal disorders. Spine. 2010;35:E458\u201364. doi:https:\/\/doi.org\/10.1097\/BRS.0b013e3181cc764f.","journal-title":"Spine"},{"key":"3916_CR22","doi-asserted-by":"publisher","unstructured":"Tohmeh AG, Isaacs RE, Dooley ZA, Turner AW. Long Construct Pedicle Screw Reduction and Residual Forces are Decreased Using a Computer-assisted Rod Bending System. J Spine Neurosurg S2 2014. doi:https:\/\/doi.org\/10.4172\/2325-9701.S2-002.","DOI":"10.4172\/2325-9701.S2-002"},{"key":"3916_CR23","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1016\/j.medengphy.2015.11.020","volume":"38","author":"F Costa","year":"2016","unstructured":"Costa F, Ortolina A, Galbusera F, Cardia A, Sala G, Ronchi F, Uccelli C, Grosso R, Fornari M. Pedicle screw cement augmentation. A mechanical pullout study on different cement augmentation techniques. Med Eng Phys. 2016;38:181\u20136. doi:https:\/\/doi.org\/10.1016\/j.medengphy.2015.11.020.","journal-title":"Med Eng Phys"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-020-03916-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12891-020-03916-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-020-03916-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,9]],"date-time":"2021-01-09T09:04:19Z","timestamp":1610183059000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-020-03916-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,9]]},"references-count":23,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["3916"],"URL":"https:\/\/doi.org\/10.1186\/s12891-020-03916-9","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-52538\/v4","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.3.rs-52538\/v3","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.3.rs-52538\/v5","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.3.rs-52538\/v2","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.3.rs-52538\/v1","asserted-by":"object"}]},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,9]]},"assertion":[{"value":"2 August 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 December 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 January 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was conducted in accordance with ethical guidelines and approved by the institutional review board of Saku Central Hospital Advanced Care Center Research Ethical Committee (Approval No. R201904-06). Patients provided written informed consent for participation.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The participants gave consent for the publication of the data described in the manuscript.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"55"}}