{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,19]],"date-time":"2026-09-19T15:11:40Z","timestamp":1789830700868,"version":"4.0.1"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,2,5]],"date-time":"2021-02-05T00:00:00Z","timestamp":1612483200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2021,2,5]],"date-time":"2021-02-05T00:00:00Z","timestamp":1612483200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Metacarpal shaft fracture is a common fracture in hand trauma injuries. Surgical intervention is indicated when fractures are unstable or involve considerable displacement. Current fixation options include Kirschner wire, bone plates, and intramedullary headless screws. Common complications include joint stiffness, tendon irritation, implant loosening, and cartilage damage.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Objective<\/jats:title>\n                <jats:p>We propose a modified fixation approach using headless compression screws to treat transverse or short-oblique metacarpal shaft fracture.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Materials and methods<\/jats:title>\n                <jats:p>We used a saw blade to model transverse metacarpal neck fractures in 28 fresh porcine metacarpals, which were then treated with the following four fixation methods: (1) locked plate with five locked bicortical screws (LP group), (2) regular plate with five bicortical screws (RP group), (3) two Kirschner wires (K group), and (4) a headless compression screw (HC group). In the HC group, we proposed a novel fixation model in which the screw trajectory was oblique to the long axis of the metacarpal bone. The entry point of the screw was in the dorsum of the metacarpal neck, and the exit point was in the volar cortex of the supracondylar region; thus, the screw did not damage the articular cartilage. The specimens were tested using a modified three-point bending test on a material testing system. The maximum fracture forces and stiffness values of the four fixation types were determined by observing the force\u2013displacement curves. Finally, the Kruskal\u2013Wallis test was adopted to process the data, and the exact Wilcoxon rank sum test with Bonferroni adjustment was performed to conduct paired comparisons among the groups.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The maximum fracture forces (median\u2009\u00b1\u2009interquartile range [IQR]) of the LP, RP, HC, and K groups were 173.0\u2009\u00b1\u200981.0, 156.0\u2009\u00b1\u2009117.9, 60.4\u2009\u00b1\u200921.0, and 51.8\u2009\u00b1\u200960.7\u2009N, respectively. In addition, the stiffness values (median\u2009\u00b1\u2009IQR) of the LP, HC, RP, and K groups were 29.6\u2009\u00b1\u20093.0, 23.1\u2009\u00b1\u20095.2, 22.6\u2009\u00b1\u20092.8, and 14.7\u2009\u00b1\u20095.6\u2009N\/mm, respectively.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Headless compression screw fixation provides fixation strength similar to locked and regular plates for the fixation of metacarpal shaft fractures. The headless screw was inserted obliquely to the long axis of the metacarpal bone. The entry point of the screw was in the dorsum of the metacarpal neck, and the exit point was in the volar cortex of the supracondylar region; therefore the articular cartilage iatrogenic injury can be avoidable. This modified fixation method may prevent tendon irritation and joint cartilage violation caused by plating and intramedullary headless screw fixation.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-020-03939-2","type":"journal-article","created":{"date-parts":[[2021,2,7]],"date-time":"2021-02-07T19:43:30Z","timestamp":1612727010000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Effect of oblique headless compression screw fixation for metacarpal shaft fracture: a biomechanical in vitro study"],"prefix":"10.1186","volume":"22","author":[{"given":"Yung-Cheng","family":"Chiu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tsung-Yu","family":"Ho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yen-Nien","family":"Ting","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ming-Tzu","family":"Tsai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heng-Li","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cheng-En","family":"Hsu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jui-Ting","family":"Hsu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,2,5]]},"reference":[{"key":"3939_CR1","doi-asserted-by":"publisher","DOI":"10.5505\/tjtes.2015.01651","volume-title":"Results of surgical treatment in metacarpal shaft fractures using low profile mini plates","author":"S Aykut","year":"2015","unstructured":"Aykut S, \u00d6zt\u00fcrk K, \u00d6zcan \u00c7, Demiro\u011flu M, G\u00fcr\u00fcn AU, \u00d6zden E. Results of surgical treatment in metacarpal shaft fractures using low profile mini plates; 2015."},{"issue":"5","key":"3939_CR2","doi-asserted-by":"publisher","first-page":"609","DOI":"10.1016\/S0266-7681(05)80120-2","volume":"20","author":"C Low","year":"1995","unstructured":"Low C, Wong H, Low Y, Wong H. A cadaver study of the effects of dorsal angulation and shortening of the metacarpal shaft on the extension and flexion force ratios of the index and little fingers. J Hand Surg. 1995;20(5):609\u201313.","journal-title":"J Hand Surg"},{"issue":"01","key":"3939_CR3","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1142\/S0218810412500098","volume":"17","author":"A Sahu","year":"2012","unstructured":"Sahu A, Gujral S, Batra S, Mills S, Srinivasan M. The current practice of the management of little finger metacarpal fractures\u2014a review of the literature and results of a survey conducted among upper limb surgeons in the United Kingdom. Hand Surg. 2012;17(01):55\u201363.","journal-title":"Hand Surg"},{"issue":"8","key":"3939_CR4","doi-asserted-by":"publisher","first-page":"1256","DOI":"10.1016\/j.jhsa.2010.05.013","volume":"35","author":"M Soong","year":"2010","unstructured":"Soong M, Got C, Katarincic J. Ring and little finger metacarpal fractures: mechanisms, locations, and radiographic parameters. J Hand Surg. 2010;35(8):1256\u20139.","journal-title":"J Hand Surg"},{"issue":"5","key":"3939_CR5","doi-asserted-by":"publisher","first-page":"506","DOI":"10.1016\/j.otsr.2010.02.009","volume":"96","author":"S Facca","year":"2010","unstructured":"Facca S, Ramdhian R, Pelissier A, Diaconu M, Liverneaux P. Fifth metacarpal neck fracture fixation: locking plate versus K-wire? Orthop Traumatol Surg Res. 2010;96(5):506\u201312. https:\/\/doi.org\/10.1016\/j.otsr.2010.02.009.","journal-title":"Orthop Traumatol Surg Res"},{"issue":"5","key":"3939_CR6","doi-asserted-by":"publisher","first-page":"1747","DOI":"10.1007\/s11999-014-4079-7","volume":"473","author":"JK Kim","year":"2015","unstructured":"Kim JK, Kim DJ. Antegrade intramedullary pinning versus retrograde intramedullary pinning for displaced fifth metacarpal neck fractures. Clin Orthop Relat Res. 2015;473(5):1747\u201354. https:\/\/doi.org\/10.1007\/s11999-014-4079-7.","journal-title":"Clin Orthop Relat Res"},{"issue":"2","key":"3939_CR7","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1016\/j.injury.2011.10.036","volume":"43","author":"V Potenza","year":"2012","unstructured":"Potenza V, Caterini R, De Maio F, Bisicchia S, Farsetti P. Fractures of the neck of the fifth metacarpal bone. Medium-term results in 28 cases treated by percutaneous transverse pinning. Injury. 2012;43(2):242\u20135. https:\/\/doi.org\/10.1016\/j.injury.2011.10.036.","journal-title":"Injury"},{"issue":"1","key":"3939_CR8","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1142\/S0218810415500148","volume":"20","author":"KP Wong","year":"2015","unstructured":"Wong KP, Hay RA, Tay SC. Surgical outcomes of fifth metacarpal neck fractures--a comparative analysis of dorsal plating versus tension band wiring. Hand Surg. 2015;20(1):99\u2013105. https:\/\/doi.org\/10.1142\/S0218810415500148.","journal-title":"Hand Surg"},{"issue":"3","key":"3939_CR9","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1308\/003588407X155482","volume":"89","author":"H Sharma","year":"2007","unstructured":"Sharma H, Taylor GR, Clarke NM. A review of K-wire related complications in the emergency management of paediatric upper extremity trauma. Ann R Coll Surg Engl. 2007;89(3):252\u20138. https:\/\/doi.org\/10.1308\/003588407X155482.","journal-title":"Ann R Coll Surg Engl"},{"key":"3939_CR10","doi-asserted-by":"publisher","first-page":"7515760","DOI":"10.1155\/2016\/7515760","volume":"2016","author":"KY Wong","year":"2016","unstructured":"Wong KY, Mole R, Gillespie P. Kirschner wire breakage during removal requiring retrieval. Case Rep Surg. 2016;2016:7515760. https:\/\/doi.org\/10.1155\/2016\/7515760.","journal-title":"Case Rep Surg"},{"key":"3939_CR11","first-page":"194","volume":"276","author":"MJ Botte","year":"1992","unstructured":"Botte MJ, Davis JL, Rose BA, von Schroeder HP, Gellman H, Zinberg EM, et al. Complications of smooth pin fixation of fractures and dislocations in the hand and wrist. Clin Orthop Relat Res. 1992;276:194\u2013201.","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"3939_CR12","doi-asserted-by":"publisher","first-page":"374","DOI":"10.1016\/j.jhsb.2004.03.003","volume":"29","author":"DG Hargreaves","year":"2004","unstructured":"Hargreaves DG, Drew SJ, Eckersley R. Kirschner wire pin tract infection rates: a randomized controlled trial between percutaneous and buried wires. J Hand Surg Br. 2004;29(4):374\u20136. https:\/\/doi.org\/10.1016\/j.jhsb.2004.03.003.","journal-title":"J Hand Surg Br"},{"issue":"4","key":"3939_CR13","doi-asserted-by":"publisher","first-page":"610","DOI":"10.1016\/j.jhsa.2011.01.023","volume":"36","author":"LP Hsu","year":"2011","unstructured":"Hsu LP, Schwartz EG, Kalainov DM, Chen F, Makowiec RL. Complications of K-wire fixation in procedures involving the hand and wrist. J Hand Surg. 2011;36(4):610\u20136.","journal-title":"J Hand Surg"},{"issue":"1","key":"3939_CR14","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1016\/J.JHSB.2005.06.022","volume":"31","author":"T Wong","year":"2006","unstructured":"Wong T, Ip F, Yeung S. Comparison between percutaneous transverse fixation and intramedullary K-wires in treating closed fractures of the metacarpal neck of the little finger. J Hand Surg. 2006;31(1):61\u20135.","journal-title":"J Hand Surg"},{"issue":"3","key":"3939_CR15","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1007\/s11552-015-9744-0","volume":"10","author":"P Malasitt","year":"2015","unstructured":"Malasitt P, Owen JR, Tremblay M-A, Wayne JS, Isaacs JE. Fixation for metacarpal neck fracture: a biomechanical study. Hand. 2015;10(3):438\u201343.","journal-title":"Hand"},{"key":"3939_CR16","doi-asserted-by":"crossref","unstructured":"Firoozbakhsh KK, Moneim MS, Doherty W, Naraghi FF, Internal fixation of oblique metacarpal fractures. A biomechanical evaluation by impact loading. Clin Orthop Relat Res. 1996;(325):296\u2013301.","DOI":"10.1097\/00003086-199604000-00036"},{"issue":"4","key":"3939_CR17","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1016\/j.jhsa.2004.03.002","volume":"29","author":"MJ Meunier","year":"2004","unstructured":"Meunier MJ, Hentzen E, Ryan M, Shin AY, Lieber RL. Predicted effects of metacarpal shortening on interosseous muscle function1. J Hand Surg. 2004;29(4):689\u201393.","journal-title":"J Hand Surg"},{"issue":"6","key":"3939_CR18","doi-asserted-by":"publisher","first-page":"1024","DOI":"10.1016\/S0363-5023(85)80029-0","volume":"10","author":"R Mann","year":"1985","unstructured":"Mann R, Black D, Constine R, Daniels A. A quantitative comparison of metacarpal fracture stability with five different methods of internal fixation. J Hand Surg. 1985;10(6):1024\u20138.","journal-title":"J Hand Surg"},{"issue":"4","key":"3939_CR19","doi-asserted-by":"publisher","first-page":"755","DOI":"10.1053\/jhsu.2001.24145","volume":"26","author":"KJ Bozic","year":"2001","unstructured":"Bozic KJ, Perez LE, Wilson DR, Fitzgibbons PG, Jupiter JB. Mechanical testing of bioresorbable implants for use in metacarpal fracture fixation. J Hand Surg. 2001;26(4):755\u201361.","journal-title":"J Hand Surg"},{"issue":"4","key":"3939_CR20","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1016\/S0363-5023(85)80067-8","volume":"10","author":"D Black","year":"1985","unstructured":"Black D, Mann R, Constine R, Daniels A. Comparison of internal fixation techniques in metacarpal fractures. J Hand Surg. 1985;10(4):466\u201372.","journal-title":"J Hand Surg"},{"key":"3939_CR21","doi-asserted-by":"publisher","first-page":"1692","DOI":"10.1100\/2011\/465371","volume":"11","author":"S Ochman","year":"2011","unstructured":"Ochman S, Vordemvenne T, Paletta J, Raschke MJ, Meffert RH, Doht S. Experimental fracture model versus osteotomy model in metacarpal bone plate fixation. Sci World J. 2011;11:1692\u20138. https:\/\/doi.org\/10.1100\/2011\/465371.","journal-title":"Sci World J"},{"issue":"1","key":"3939_CR22","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1007\/s11552-013-9562-1","volume":"9","author":"KM Kollitz","year":"2014","unstructured":"Kollitz KM, Hammert WC, Vedder NB, Huang JI. Metacarpal fractures: treatment and complications. Hand. 2014;9(1):16\u201323. https:\/\/doi.org\/10.1007\/s11552-013-9562-1.","journal-title":"Hand"},{"issue":"3","key":"3939_CR23","doi-asserted-by":"publisher","DOI":"10.5812\/atr.32933","volume":"5","author":"EM Padegimas","year":"2016","unstructured":"Padegimas EM, Warrender WJ, Jones CM, Ilyas AM. Metacarpal neck fractures: a review of surgical indications and techniques. Arch Trauma Res. 2016;5(3):e32933. https:\/\/doi.org\/10.5812\/atr.32933.","journal-title":"Arch Trauma Res"},{"issue":"4","key":"3939_CR24","doi-asserted-by":"publisher","first-page":"692","DOI":"10.1016\/j.jhsa.2014.11.023","volume":"40","author":"F del Pi\u00f1al","year":"2015","unstructured":"del Pi\u00f1al F, Moraleda E, R\u00faas JS, de Piero GH, Cerezal L. Minimally invasive fixation of fractures of the phalanges and metacarpals with intramedullary cannulated headless compression screws. J Hand Surg. 2015;40(4):692\u2013700.","journal-title":"J Hand Surg"},{"issue":"5","key":"3939_CR25","doi-asserted-by":"publisher","first-page":"392. e1","DOI":"10.1016\/j.jhsa.2017.02.013","volume":"42","author":"IIIDM Avery","year":"2017","unstructured":"Avery IIIDM, Klinge S, Dyrna F, Pauzenberger L, Lam D, Cote M, et al. Headless compression screw versus Kirschner wire fixation for metacarpal neck fractures: a biomechanical study. J Hand Surg. 2017;42(5):392. e1\u20136.","journal-title":"J Hand Surg"},{"issue":"4","key":"3939_CR26","first-page":"e4466","volume":"11","author":"AA Siddiqui","year":"2019","unstructured":"Siddiqui AA, Kumar J, Jamil M, Adeel M, Kaimkhani GM. Fixation of metacarpal fractures using intramedullary headless compression screws: a tertiary care institution experience. Cureus. 2019;11(4):e4466.","journal-title":"Cureus"},{"issue":"3","key":"3939_CR27","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1055\/s-0036-1593390","volume":"8","author":"DG Tobert","year":"2016","unstructured":"Tobert DG, Klausmeyer M, Mudgal CS. Intramedullary fixation of metacarpal fractures using headless compression screws. J Hand Microsurg. 2016;8(3):134.","journal-title":"J Hand Microsurg"},{"issue":"7","key":"3939_CR28","doi-asserted-by":"publisher","first-page":"1206","DOI":"10.1093\/rheumatology\/key443","volume":"58","author":"J Hurnakova","year":"2019","unstructured":"Hurnakova J, Filippucci E, Cipolletta E, Di Matteo A, Salaffi F, Carotti M, et al. Prevalence and distribution of cartilage damage at the metacarpal head level in rheumatoid arthritis and osteoarthritis: an ultrasound study. Rheumatology. 2019;58(7):1206\u201313.","journal-title":"Rheumatology"},{"issue":"10","key":"3939_CR29","doi-asserted-by":"publisher","first-page":"606","DOI":"10.1038\/nrrheum.2015.95","volume":"11","author":"T Pap","year":"2015","unstructured":"Pap T, Korb-Pap A. Cartilage damage in osteoarthritis and rheumatoid arthritis\u2014two unequal siblings. Nat Rev Rheumatol. 2015;11(10):606.","journal-title":"Nat Rev Rheumatol"},{"key":"3939_CR30","doi-asserted-by":"publisher","first-page":"648787","DOI":"10.1155\/2014\/648787","volume":"2014","author":"S Doht","year":"2014","unstructured":"Doht S, Meffert RH, Raschke MJ, Blunk T, Ochman S. Biomechanical analysis of the efficacy of locking plates during cyclic loading in metacarpal fractures. Sci World J. 2014;2014:648787. https:\/\/doi.org\/10.1155\/2014\/648787.","journal-title":"Sci World J"},{"issue":"4","key":"3939_CR31","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1016\/j.jhsa.2010.01.002","volume":"35","author":"S Ochman","year":"2010","unstructured":"Ochman S, Doht S, Paletta J, Langer M, Raschke MJ, Meffert RH. Comparison between locking and non-locking plates for fixation of metacarpal fractures in an animal model. J Hand Surg. 2010;35(4):597\u2013603.","journal-title":"J Hand Surg"},{"issue":"4","key":"3939_CR32","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1007\/s11552-013-9544-3","volume":"8","author":"C Barr","year":"2013","unstructured":"Barr C, Behn AW, Yao J. Plating of metacarpal fractures with locked or nonlocked screws, a biomechanical study: how many cortices are really necessary? Hand. 2013;8(4):454\u20139. https:\/\/doi.org\/10.1007\/s11552-013-9544-3.","journal-title":"Hand"},{"issue":"8","key":"3939_CR33","doi-asserted-by":"publisher","first-page":"1586","DOI":"10.1016\/j.jhsa.2015.03.035","volume":"40","author":"SV Hiatt","year":"2015","unstructured":"Hiatt SV, Begonia MT, Thiagarajan G, Hutchison RL. Biomechanical comparison of 2 methods of intramedullary K-wire fixation of transverse metacarpal shaft fractures. J Hand Surg. 2015;40(8):1586\u201390.","journal-title":"J Hand Surg"},{"issue":"1","key":"3939_CR34","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1186\/s13018-018-0890-2","volume":"13","author":"Y-C Chiu","year":"2018","unstructured":"Chiu Y-C, Tsai M-T, Hsu C-E, Hsu H-C, Huang H-L, Hsu J-T. New fixation approach for transverse metacarpal neck fracture: a biomechanical study. J Orthop Surg Res. 2018;13(1):183.","journal-title":"J Orthop Surg Res"},{"issue":"1","key":"3939_CR35","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1007\/s11552-014-9673-3","volume":"10","author":"AJ Watt","year":"2015","unstructured":"Watt AJ, Ching RP, Huang JI. Biomechanical evaluation of metacarpal fracture fixation: application of a 90 degrees internal fixation model. Hand. 2015;10(1):94\u20139. https:\/\/doi.org\/10.1007\/s11552-014-9673-3.","journal-title":"Hand"},{"issue":"3","key":"3939_CR36","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1111\/os.12195","volume":"7","author":"BD Curtis","year":"2015","unstructured":"Curtis BD, Fajolu O, Ruff ME, Litsky AS. Fixation of metacarpal shaft fractures: biomechanical comparison of intramedullary nail crossed K-wires and plate-screw constructs. Orthop Surg. 2015;7(3):256\u201360. https:\/\/doi.org\/10.1111\/os.12195.","journal-title":"Orthop Surg"},{"issue":"27","key":"3939_CR37","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000006926","volume":"96","author":"E Liodaki","year":"2017","unstructured":"Liodaki E, Wendlandt R, Waizner K, Schopp BE, Mailander P, Stang F. A biomechanical analysis of plate fixation using unicortical and bicortical screws in transverse metacarpal fracture models subjected to 4-point bending and dynamical bending test. Medicine. 2017;96(27):e6926. https:\/\/doi.org\/10.1097\/MD.0000000000006926.","journal-title":"Medicine"},{"issue":"12","key":"3939_CR38","doi-asserted-by":"publisher","first-page":"1033. e1","DOI":"10.1016\/j.jhsa.2017.07.018","volume":"42","author":"A Eu-Jin Cheah","year":"2017","unstructured":"Eu-Jin Cheah A, Behn AW, Comer G, Yao J. A Biomechanical Analysis of 2 Constructs for Metacarpal Spiral Fracture Fixation in a Cadaver Model: 2 Large Screws Versus 3 Small Screws. J Hand Surg Am. 2017;42(12):1033. e1\u20136. https:\/\/doi.org\/10.1016\/j.jhsa.2017.07.018.","journal-title":"J Hand Surg Am"},{"issue":"1","key":"3939_CR39","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1177\/1558944718798854","volume":"14","author":"D Dreyfuss","year":"2019","unstructured":"Dreyfuss D, Allon R, Izacson N, Hutt D. A comparison of locking plates and intramedullary pinning for fixation of metacarpal shaft fractures. Hand. 2019;14(1):27\u201333.","journal-title":"Hand"},{"issue":"5","key":"3939_CR40","doi-asserted-by":"publisher","first-page":"e2261","DOI":"10.1097\/GOX.0000000000002261","volume":"7","author":"V Vasilakis","year":"2019","unstructured":"Vasilakis V, Sinnott CJ, Hamade M, Hamade H, Pinsky BA. Extra-articular metacarpal fractures: closed reduction and percutaneous pinning versus open reduction and internal fixation. Plastic Reconstr Surg Glob Open. 2019;7(5):e2261.","journal-title":"Plastic Reconstr Surg Glob Open"},{"issue":"2","key":"3939_CR41","first-page":"111","volume":"22","author":"J Elfar","year":"2014","unstructured":"Elfar J, Stanbury S, Menorca RM, Reed JD. Composite bone models in orthopaedic surgery research and education. J Am Acad Orthop Surg. 2014;22(2):111.","journal-title":"J Am Acad Orthop Surg"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-020-03939-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12891-020-03939-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-020-03939-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,2,7]],"date-time":"2021-02-07T19:43:41Z","timestamp":1612727021000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-020-03939-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,5]]},"references-count":41,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["3939"],"URL":"https:\/\/doi.org\/10.1186\/s12891-020-03939-2","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,2,5]]},"assertion":[{"value":"22 October 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 December 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 February 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare there are no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"146"}}