{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T14:56:51Z","timestamp":1793372211643,"version":"4.5.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,3,12]],"date-time":"2020-03-12T00:00:00Z","timestamp":1583971200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2020,3,12]],"date-time":"2020-03-12T00:00:00Z","timestamp":1583971200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"the National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["31670956"],"award-info":[{"award-number":["31670956"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Background<\/jats:title>\n<jats:p>Individualized and accurate implantation of a tibial prosthesis during total knee arthroplasty (TKA) can assist in uniformly distributing the load and reducing the polyethylene wear to obtain a long-term prosthetic survival rate, but individualized and accurate implantation of a tibial prosthesis during TKA remains challenging. The purpose of this study was to optimize and individualize the positioning parameters of a tibial prosthesis to improve its accurate implantation using a new method of finite element analysis in combination with orthogonal experimental design.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>Ten finite element models of TKA knee joint were developed to optimize the implantation parameters (varus angle, posterior slope angle, and external rotation angle) of tibial prosthesis to reduce the peak value of the contact pressure on the polyethylene liner according to the method of finite element analysis in combination with orthogonal experimental design. The influence of implantation parameters on the peak value of the contact pressure on the polyethylene liner was evaluated based on a range analysis in orthogonal experimental design.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>The optimal implantation parameters for tibial prosthesis included 0\u00b0 varus, 1\u00b0 posterior slope, and 4\u00b0 external rotation. Under these conditions, the peak value of the contact pressure on the polyethylene liner remained the smallest (16.37\u2009MPa). Among the three parameters that affect the peak value of the contact pressure, the varus angle had the greatest effect (range\u2009=\u20096.70), followed by the posterior slope angle (range\u2009=\u20092.36), and the external rotation angle (range\u2009=\u20092.15).<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>The optimization method based on finite element analysis and orthogonal experimental design can guide the accurate implantation of the tibial prosthesis, reducing the peak value of the contact pressure on the polyethylene liner. This method provides new insights into the TKA preoperative plan and biomechanical decision-making for accurately implanting TKA prosthesis.<\/jats:p>\n<\/jats:sec>","DOI":"10.1186\/s12891-020-3189-5","type":"journal-article","created":{"date-parts":[[2020,3,12]],"date-time":"2020-03-12T20:02:45Z","timestamp":1584043365000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["An optimization method for implantation parameters of individualized TKA tibial prosthesis based on finite element analysis and orthogonal experimental design"],"prefix":"10.1186","volume":"21","author":[{"given":"Yuefu","family":"Dong","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhen","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wanpeng","family":"Dong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guanghong","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bing","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhifang","family":"Mou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,3,12]]},"reference":[{"issue":"5","key":"3189_CR1","doi-asserted-by":"publisher","first-page":"1577","DOI":"10.1007\/s00167-017-4640-5","volume":"26","author":"WA Manning","year":"2018","unstructured":"Manning WA, Ghosh KM, Blain A, Longstaff L, Rushton SP, Deehan DJ. Internal femoral component rotation adversely influences load transfer in total knee arthroplasty: a cadaveric navigated study using the Verasense device. Knee Surg Sports Traumatol Arthrosc. 2018;26(5):1577\u201385.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"7S","key":"3189_CR2","doi-asserted-by":"publisher","first-page":"S355","DOI":"10.1016\/j.arth.2018.10.022","volume":"34","author":"M Saffi","year":"2019","unstructured":"Saffi M, Spangehl MJ, Clarke HD, Young SW. Measuring Tibial component rotation following Total knee Arthroplasty: what is the best method? J Arthroplast. 2019;34(7S):S355\u2013S60.","journal-title":"J Arthroplast"},{"key":"3189_CR3","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1097\/01.blo.0000148578.22729.0e","volume":"428","author":"ME Berend","year":"2004","unstructured":"Berend ME, Ritter MA, Meding JB, Faris PM, Keating EM, Redelman R, et al. Tibial component failure mechanisms in total knee arthroplasty. Clin Orthop Relat Res. 2004;428:26\u201334.","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"3189_CR4","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1016\/j.arth.2015.07.038","volume":"31","author":"B Innocenti","year":"2016","unstructured":"Innocenti B, Bellemans J, Catani F. Deviations from optimal alignment in TKA: is there a biomechanical difference between femoral or Tibial component alignment? J Arthroplast. 2016;31(1):295\u2013301.","journal-title":"J Arthroplast"},{"issue":"3","key":"3189_CR5","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1002\/jor.21221","volume":"29","author":"J Wong","year":"2011","unstructured":"Wong J, Steklov N, Patil S, Flores-Hernandez C, Kester M, Colwell CW Jr, et al. Predicting the effect of tray malalignment on risk for bone damage and implant subsidence after total knee arthroplasty. J Orthop Res. 2011;29(3):347\u201353.","journal-title":"J Orthop Res"},{"issue":"4","key":"3189_CR6","doi-asserted-by":"publisher","first-page":"220","DOI":"10.5435\/JAAOS-D-14-00332","volume":"24","author":"M Tanzer","year":"2016","unstructured":"Tanzer M, Makhdom AM. Preoperative planning in primary Total knee Arthroplasty. J Am Acad Orthop Surg. 2016;24(4):220\u201330.","journal-title":"J Am Acad Orthop Surg"},{"issue":"6","key":"3189_CR7","doi-asserted-by":"publisher","first-page":"1778","DOI":"10.1007\/s00167-016-4196-9","volume":"25","author":"A Todesca","year":"2017","unstructured":"Todesca A, Garro L, Penna M, Bejui-Hugues J. Conventional versus computer-navigated TKA: a prospective randomized study. Knee Surg Sports Traumatol Arthrosc. 2017;25(6):1778\u201383.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"1","key":"3189_CR8","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1007\/s00167-014-3345-2","volume":"24","author":"W Anderl","year":"2016","unstructured":"Anderl W, Pauzenberger L, Kolblinger R, Kiesselbach G, Brandl G, Laky B, et al. Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA. Knee Surg Sports Traumatol Arthrosc. 2016;24(1):102\u201311.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"6","key":"3189_CR9","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1007\/s00590-012-1051-7","volume":"23","author":"G Stan","year":"2013","unstructured":"Stan G, Orban H, Gruionu L, Gheorghe P. Coronal malposition effects in total knee arthroplasty: a finite element analysis. Eur J Orthop Surg Traumatol. 2013;23(6):685\u201390.","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"3189_CR10","doi-asserted-by":"publisher","first-page":"695028","DOI":"10.1155\/2014\/695028","volume":"2014","author":"K Osano","year":"2014","unstructured":"Osano K, Nagamine R, Todo M, Kawasaki M. The effect of malrotation of tibial component of total knee arthroplasty on tibial insert during high flexion using a finite element analysis. ScientificWorldJournal. 2014;2014:695028.","journal-title":"ScientificWorldJournal"},{"issue":"11","key":"3189_CR11","doi-asserted-by":"publisher","first-page":"3330","DOI":"10.1007\/s00167-014-3144-9","volume":"23","author":"Y Shen","year":"2015","unstructured":"Shen Y, Li X, Fu X, Wang W. A 3D finite element model to investigate prosthetic interface stresses of different posterior tibial slope. Knee Surg Sports Traumatol Arthrosc. 2015;23(11):3330\u20136.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"13","key":"3189_CR12","doi-asserted-by":"publisher","first-page":"1452","DOI":"10.1080\/10255842.2012.753063","volume":"17","author":"Y Dong","year":"2014","unstructured":"Dong Y, Hu G, Dong Y, Hu Y, Xu Q. The effect of meniscal tears and resultant partial meniscectomies on the knee contact stresses: a finite element analysis. Comput Methods Biomech Biomed Engin. 2014;17(13):1452\u201363.","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"3189_CR13","doi-asserted-by":"publisher","first-page":"620","DOI":"10.1007\/s12204-011-1199-z","volume":"16","author":"YHG Dong","year":"2011","unstructured":"Dong YHG, Yang H, Zhang L, Hu Y, Dong Y, Xu Q. Accurate 3D reconstruction of subject-specific knee finite element model to simulate the articular cartilage defects. J Shanghai Jiaotong Univ (Sci). 2011;16:620\u20137.","journal-title":"J Shanghai Jiaotong Univ (Sci)"},{"issue":"5","key":"3189_CR14","doi-asserted-by":"publisher","first-page":"498","DOI":"10.1016\/j.clinbiomech.2005.01.009","volume":"20","author":"E Pena","year":"2005","unstructured":"Pena E, Calvo B, Martinez MA, Palanca D, Doblare M. Finite element analysis of the effect of meniscal tears and meniscectomies on human knee biomechanics. Clin Biomech (Bristol, Avon). 2005;20(5):498\u2013507.","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"5","key":"3189_CR15","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1115\/1.1992522","volume":"127","author":"JP Halloran","year":"2005","unstructured":"Halloran JP, Easley SK, Petrella AJ, Rullkoetter PJ. Comparison of deformable and elastic foundation finite element simulations for predicting knee replacement mechanics. J Biomech Eng. 2005;127(5):813\u20138.","journal-title":"J Biomech Eng"},{"issue":"6 Suppl","key":"3189_CR16","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/j.arth.2009.04.034","volume":"24","author":"DM Fang","year":"2009","unstructured":"Fang DM, Ritter MA, Davis KE. Coronal alignment in total knee arthroplasty: just how important is it? J Arthroplast. 2009;24(6 Suppl):39\u201343.","journal-title":"J Arthroplast"},{"key":"3189_CR17","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1097\/BLO.0b013e3180332d97","volume":"458","author":"SJ Incavo","year":"2007","unstructured":"Incavo SJ, Wild JJ, Coughlin KM, Beynnon BD. Early revision for component malrotation in total knee arthroplasty. Clin Orthop Relat Res. 2007;458:131\u20136.","journal-title":"Clin Orthop Relat Res"},{"issue":"2","key":"3189_CR18","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1016\/S0268-0033(01)00109-7","volume":"17","author":"JJ Liau","year":"2002","unstructured":"Liau JJ, Cheng CK, Huang CH, Lo WH. The effect of malalignment on stresses in polyethylene component of total knee prostheses--a finite element analysis. Clin Biomech (Bristol, Avon). 2002;17(2):140\u20136.","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"3189_CR19","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1186\/1749-799X-4-26","volume":"4","author":"B Innocenti","year":"2009","unstructured":"Innocenti B, Truyens E, Labey L, Wong P, Victor J, Bellemans J. Can medio-lateral baseplate position and load sharing induce asymptomatic local bone resorption of the proximal tibia? A finite element study. J Orthop Surg Res. 2009;4:26.","journal-title":"J Orthop Surg Res"},{"key":"3189_CR20","first-page":"405","volume":"55","author":"J Benjamin","year":"2006","unstructured":"Benjamin J. Component alignment in total knee arthroplasty. Instr Course Lect. 2006;55:405\u201312.","journal-title":"Instr Course Lect"},{"issue":"3","key":"3189_CR21","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1080\/17453670510041303","volume":"76","author":"JY Jenny","year":"2005","unstructured":"Jenny JY, Boeri C, Ballonzoli L. Coronal alignment of the lower limb. Acta Orthop. 2005;76(3):403\u20137.","journal-title":"Acta Orthop"},{"issue":"9","key":"3189_CR22","doi-asserted-by":"publisher","first-page":"1121","DOI":"10.1302\/0301-620X.90B9.20793","volume":"90","author":"JM Sikorski","year":"2008","unstructured":"Sikorski JM. Alignment in total knee replacement. J Bone Joint Surg Br. 2008;90(9):1121\u20137.","journal-title":"J Bone Joint Surg Br"},{"issue":"8","key":"3189_CR23","doi-asserted-by":"publisher","first-page":"1043","DOI":"10.1302\/0301-620X.98B8.37240","volume":"98-B","author":"HJ Huijbregts","year":"2016","unstructured":"Huijbregts HJ, Khan RJ, Fick DP, Hall MJ, Punwar SA, Sorensen E, et al. Component alignment and clinical outcome following total knee arthroplasty: a randomised controlled trial comparing an intramedullary alignment system with patient-specific instrumentation. Bone Joint J. 2016;98-B(8):1043\u20139.","journal-title":"Bone Joint J"},{"issue":"9","key":"3189_CR24","doi-asserted-by":"publisher","first-page":"1217","DOI":"10.1302\/0301-620X.93B9.26573","volume":"93","author":"TJ Bonner","year":"2011","unstructured":"Bonner TJ, Eardley WG, Patterson P, Gregg PJ. The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 years. J Bone Joint Surg Br. 2011;93(9):1217\u201322.","journal-title":"J Bone Joint Surg Br"},{"issue":"12","key":"3189_CR25","doi-asserted-by":"publisher","first-page":"2143","DOI":"10.2106\/JBJS.I.01398","volume":"92","author":"S Parratte","year":"2010","unstructured":"Parratte S, Pagnano MW, Trousdale RT, Berry DJ. Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Joint Surg Am. 2010;92(12):2143\u20139.","journal-title":"J Bone Joint Surg Am"},{"issue":"10","key":"3189_CR26","doi-asserted-by":"publisher","first-page":"1354","DOI":"10.1302\/0301-620X.95B10.31477","volume":"95-B","author":"G Singh","year":"2013","unstructured":"Singh G, Tan JH, Sng BY, Awiszus F, Lohmann CH, Nathan SS. Restoring the anatomical tibial slope and limb axis may maximise post-operative flexion in posterior-stabilised total knee replacements. Bone Joint J. 2013;95-B(10):1354\u20138.","journal-title":"Bone Joint J"},{"issue":"5","key":"3189_CR27","doi-asserted-by":"publisher","first-page":"480","DOI":"10.3109\/17453674.2014.940573","volume":"85","author":"K Gromov","year":"2014","unstructured":"Gromov K, Korchi M, Thomsen MG, Husted H, Troelsen A. What is the optimal alignment of the tibial and femoral components in knee arthroplasty? Acta Orthop. 2014;85(5):480\u20137.","journal-title":"Acta Orthop"},{"issue":"2","key":"3189_CR28","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1007\/s00264-013-2097-9","volume":"38","author":"YH Kim","year":"2014","unstructured":"Kim YH, Park JW, Kim JS, Park SD. The relationship between the survival of total knee arthroplasty and postoperative coronal, sagittal and rotational alignment of knee prosthesis. Int Orthop. 2014;38(2):379\u201385.","journal-title":"Int Orthop"},{"issue":"11","key":"3189_CR29","doi-asserted-by":"publisher","first-page":"1603","DOI":"10.2106\/00004623-200011000-00014","volume":"82","author":"WM Tang","year":"2000","unstructured":"Tang WM, Zhu YH, Chiu KY. Axial alignment of the lower extremity in Chinese adults. J Bone Joint Surg Am. 2000;82(11):1603\u20138.","journal-title":"J Bone Joint Surg Am"},{"issue":"3","key":"3189_CR30","doi-asserted-by":"crossref","first-page":"230949901773949","DOI":"10.1177\/2309499017739498","volume":"25","author":"JH Park","year":"2017","unstructured":"Park JH, Bin SI, Kim JM, Lee BS, Lee CR, Kim JM, et al. Comparison of patellar tracking according to different angles of external rotation of femoral component in varus knee of Asians. J Orthop Surg. 2017;25(3):2309499017739498.","journal-title":"J Orthop Surg"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-020-3189-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12891-020-3189-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-020-3189-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,12]],"date-time":"2021-03-12T00:35:43Z","timestamp":1615509343000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-020-3189-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,3,12]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["3189"],"URL":"https:\/\/doi.org\/10.1186\/s12891-020-3189-5","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,3,12]]},"assertion":[{"value":"15 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 March 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 March 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was approved by the ethics committee of the Affiliated Lianyungang Hospital of Xuzhou Medical University (No. 2016008), and informed consent was signed by the volunteer and his family members.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"165"}}