{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T19:59:21Z","timestamp":1791489561305,"version":"4.3.4"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,4,7]],"date-time":"2021-04-07T00:00:00Z","timestamp":1617753600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2021,4,7]],"date-time":"2021-04-07T00:00:00Z","timestamp":1617753600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100007307","name":"Arthrex","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007307","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100004869","name":"Westf\u00e4lische Wilhelms-Universit\u00e4t M\u00fcnster","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100004869","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Metacarpal shaft fractures are common and can be treated nonoperatively. Shortening, angulation, and rotational deformity are indications for surgical treatment. Various forms of treatment with advantages and disadvantages have been documented. The purpose of the study was to determine the stability of fracture fixation with intramedullary headless compression screws in two types of metacarpal shaft fractures and compare them to other common forms of rigid fixation: dorsal plating and lag screw fixation. It was hypothesized that headless compression screws would demonstrate a biomechanical stronger construct.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Five matched paired hands (age 60.9\u2009\u00b1\u20094.6\u2009years), utilizing non-thumb metacarpals, were used for comparative fixation in two fracture types created by an osteotomy. In transverse diaphyseal fractures, fixation by headless compression screws (<jats:italic>n<\/jats:italic>\u00a0=\u20097) and plating (<jats:italic>n<\/jats:italic>\u00a0=\u20098) were compared. In long oblique diaphyseal fractures, headless compression screws (<jats:italic>n<\/jats:italic>\u00a0=\u20098) were compared with plating (<jats:italic>n<\/jats:italic>\u00a0=\u20098) and lag screws (<jats:italic>n<\/jats:italic>\u00a0=\u20097). Testing was performed using an MTS frame producing an apex dorsal, three point bending force. Peak load to failure and stiffness were calculated from the load-displacement curve generated.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>For transverse fractures, headless compression screws had a significantly higher stiffness and peak load to failure, means 249.4\u2009N\/mm and 584.8\u2009N, than plates, means 129.02\u2009N\/mm and 303.9\u2009N (both <jats:italic>p<\/jats:italic>\u00a0&lt;\u20090.001). For long oblique fractures, stiffness and peak load to failure for headless compression screws were means 209\u2009N\/mm and 758.4\u2009N, for plates\u00a0258.7\u2009N\/mm and 518.5\u2009N, and for lag screws 172.18\u2009N\/mm and 234.11\u2009N. There was significance in peak load to failure for headless compression screws vs plates (<jats:italic>p<\/jats:italic>\u00a0=\u20090.023), headless compression screws vs lag screws (<jats:italic>p<\/jats:italic>\u00a0&lt;\u20090.001), and plates vs lag screws (<jats:italic>p<\/jats:italic>\u00a0=\u20090.009). There was no significant difference in stiffness between groups.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Intramedullary fixation of diaphyseal metacarpal fractures with a headless compression screw provides excellent biomechanical stability. Coupled with lower risks for adverse effects, headless compression screws may be a preferable option for those requiring rapid return to sport or work.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Level of evidence<\/jats:title>\n                <jats:p>Basic Science Study, Biomechanics.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-021-04200-0","type":"journal-article","created":{"date-parts":[[2021,4,7]],"date-time":"2021-04-07T06:02:32Z","timestamp":1617775352000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":30,"title":["Metacarpal shaft fixation: a biomechanical comparison of dorsal plating, lag screws, and headless compression screws"],"prefix":"10.1186","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2078-2241","authenticated-orcid":false,"given":"Felix G. E.","family":"Dyrna","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"III","given":"Daniel M.","family":"Avery","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryu","family":"Yoshida","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Lam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Simon","family":"Oeckenp\u00f6hler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark P.","family":"Cote","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elifho","family":"Obopilwe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Craig M.","family":"Rodner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Augustus D.","family":"Mazzocca","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,4,7]]},"reference":[{"key":"4200_CR1","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1111\/os.12195","volume":"7","author":"BD Curtis","year":"2015","unstructured":"Curtis BD, Fajolu O, Ruff ME, Litsky AS. Fixation of Metacarpal Shaft Fractures: Biomechanical Comparison of Intramedullary Nail Crossed K-Wires and Plate-Screw Constructs. Orthop Surg. 2015;7:256\u201360 2nd ed. John Wiley & Sons, Ltd.","journal-title":"Orthop Surg"},{"issue":"2","key":"4200_CR2","first-page":"12","volume":"2","author":"C McCarthy","year":"2014","unstructured":"McCarthy C, Samora JB, Awan H. Metacarpal shaft fractures: a review. OA Orthopaedics. 2014;2(2):12.","journal-title":"OA Orthopaedics"},{"issue":"4","key":"4200_CR3","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1053\/jssh.2002.36788","volume":"2","author":"LP Weinstein","year":"2002","unstructured":"Weinstein LP, Hanel DP. Metacarpal fractures. J Am Soc Surg Hand. 2002;2(4):168\u201380. https:\/\/doi.org\/10.1053\/jssh.2002.36788.","journal-title":"J Am Soc Surg Hand"},{"issue":"3","key":"4200_CR4","doi-asserted-by":"publisher","first-page":"535","DOI":"10.1097\/00005373-200203000-00019","volume":"52","author":"C Fusetti","year":"2002","unstructured":"Fusetti C, Meyer H, Borisch N, Stern R, Santa DD, Papalo\u00efzos M. Complications of plate fixation in metacarpal fractures. J Trauma. 2002;52(3):535\u20139. https:\/\/doi.org\/10.1097\/00005373-200203000-00019.","journal-title":"J Trauma"},{"issue":"8","key":"4200_CR5","doi-asserted-by":"publisher","first-page":"1586","DOI":"10.1016\/j.jhsa.2015.03.035","volume":"40","author":"SV Hiatt","year":"2015","unstructured":"Hiatt SV, Begonia MT, Thiagarajan G, Hutchison RL. Biomechanical comparison of 2 methods of intramedullary K-wire fixation of transverse metacarpal shaft fractures. J Hand Surg Am. 2015;40(8):1586\u201390. https:\/\/doi.org\/10.1016\/j.jhsa.2015.03.035.","journal-title":"J Hand Surg Am"},{"issue":"12","key":"4200_CR6","doi-asserted-by":"publisher","first-page":"2390","DOI":"10.1016\/j.jhsa.2014.08.016","volume":"39","author":"DE Ruchelsman","year":"2014","unstructured":"Ruchelsman DE, Puri S, Feinberg-Zadek N, Leibman MI, Belsky MR. Clinical outcomes of limited-open retrograde intramedullary headless screw fixation of metacarpal fractures. J Hand Surg Am. 2014;39(12):2390\u20135. https:\/\/doi.org\/10.1016\/j.jhsa.2014.08.016.","journal-title":"J Hand Surg Am."},{"key":"4200_CR7","first-page":"155894471983623","volume":"52","author":"G Eisenberg","year":"2019","unstructured":"Eisenberg G, Clain JB, Feinberg-Zadek N, Leibman M, Belsky M, Ruchelsman DE. Clinical Outcomes of Limited Open Intramedullary Headless Screw Fixation of Metacarpal Fractures in 91 Consecutive Patients. Hand (New York, N,Y). 2019;52:155894471983623\u20135.","journal-title":"Hand (New York, N,Y)"},{"issue":"4","key":"4200_CR8","doi-asserted-by":"publisher","first-page":"1111","DOI":"10.1097\/PRS.0000000000005478","volume":"143","author":"CM Beck","year":"2019","unstructured":"Beck CM, Horesh E, Taub PJ. Intramedullary screw fixation of metacarpal fractures results in excellent functional outcomes. Plast Reconstr Surg. 2019;143(4):1111\u20138. https:\/\/doi.org\/10.1097\/PRS.0000000000005478.","journal-title":"Plast Reconstr Surg"},{"key":"4200_CR9","doi-asserted-by":"crossref","unstructured":"Canton SP, Dadi S, Anthony A, Black RT, Clancy M, Fowler JR. Comparison of Screw Quantity and Placement of Metacarpal Fracture Fixation: A Biomechanical Study. Hand (New York, N,Y). 2020:1558944720974116. [Epub ahead of print]","DOI":"10.1177\/1558944720974116"},{"key":"4200_CR10","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1007\/s11552-014-9673-3","volume":"10","author":"AJ Watt","year":"2015","unstructured":"Watt AJ, Ching RP, Huang JI. Biomechanical evaluation of metacarpal fracture fixation: application of a 90\u00b0 internal fixation model. Hand (New York, N,Y). 2015;10:94\u20139.","journal-title":"Hand (New York, N,Y)"},{"key":"4200_CR11","doi-asserted-by":"publisher","first-page":"392.e1","DOI":"10.1016\/j.jhsa.2017.02.013","volume":"42","author":"DM Avery","year":"2017","unstructured":"Avery DM, Klinge S, Dyrna F, Pauzenberger L, Lam D, Cote M, et al. Headless Compression Screw Versus Kirschner Wire Fixation for Metacarpal Neck Fractures: A Biomechanical Study. J Hand Surg Am. 2017;42:392.e1\u20136.","journal-title":"J Hand Surg Am"},{"key":"4200_CR12","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1007\/s11552-013-9544-3","volume":"8","author":"C Barr","year":"2013","unstructured":"Barr C, Behn AW, Yao J. Plating of metacarpal fractures with locked or nonlocked screws, a biomechanical study: how many cortices are really necessary? Hand (New York, N,Y). 2013;8:454\u20139.","journal-title":"Hand (New York, N,Y)"},{"key":"4200_CR13","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1302\/0301-620X.66B1.6693468","volume":"66","author":"TJ Herbert","year":"1984","unstructured":"Herbert TJ, Fisher WE. Management of the fractured scaphoid using a new bone screw. J Bone Joint Surg Br. 1984;66:114\u201323 The British Editorial Society of Bone and Joint Surgery.","journal-title":"J Bone Joint Surg Br"},{"issue":"4","key":"4200_CR14","doi-asserted-by":"publisher","first-page":"692","DOI":"10.1016\/j.jhsa.2014.11.023","volume":"40","author":"F del Pi\u00f1al","year":"2015","unstructured":"del Pi\u00f1al F, Moraleda E, R\u00faas JS, de Piero GH, Cerezal L. Minimally invasive fixation of fractures of the phalanges and metacarpals with intramedullary cannulated headless compression screws. J Hand Surg Am. 2015;40(4):692\u2013700. https:\/\/doi.org\/10.1016\/j.jhsa.2014.11.023.","journal-title":"J Hand Surg Am."},{"key":"4200_CR15","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1177\/1753193416641319","volume":"41","author":"P Borbas","year":"2016","unstructured":"Borbas P, Dreu M, Poggetti A, Calcagni M, Giesen T. Treatment of proximal phalangeal fractures with an antegrade intramedullary screw: a cadaver study. J Hand Surg Eur Vol. 2016;41:683\u20137 SAGE PublicationsSage UK: London, England.","journal-title":"J Hand Surg Eur Vol"},{"key":"4200_CR16","unstructured":"Warrender WJ, Ruchelsman DE, Livesey MG, Mudgal CS, Rivlin M. Low Rate of Complications Following Intramedullary Headless Compression Screw Fixation of Metacarpal Fractures. Hand (New York, N,Y.). 2020;15:798\u2013804."},{"issue":"6","key":"4200_CR17","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1177\/1753193419898066","volume":"45","author":"R Lab\u00e8r","year":"2020","unstructured":"Lab\u00e8r R, Jann D, Behm P, Ferguson SJ, Frueh FS, Calcagni M. Intramedullary screw fixation for metacarpal shaft fractures: a biomechanical human cadaver study. J Hand Surg Eur Vol. 2020;45(6):595\u2013600. https:\/\/doi.org\/10.1177\/1753193419898066.","journal-title":"J Hand Surg Eur Vol"},{"key":"4200_CR18","doi-asserted-by":"publisher","first-page":"762","DOI":"10.1007\/s11552-015-9769-4","volume":"10","author":"BE Etier","year":"2015","unstructured":"Etier BE, Scillia AJ, Tessier DD, Aune KT, Emblom BA, Dugas JR, et al. Return to play following metacarpal fractures in football players. Hand (New York, N,Y). 2015;10:762\u20136 SAGE PublicationsSage CA: Los Angeles, CA.","journal-title":"Hand (New York, N,Y)"},{"issue":"2","key":"4200_CR19","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1016\/0363-5023(92)90408-H","volume":"17","author":"F Schuind","year":"1992","unstructured":"Schuind F, Garcia-Elias M, Cooney WP, An KN. Flexor tendon forces: in vivo measurements. J Hand Surg Am. 1992;17(2):291\u20138. https:\/\/doi.org\/10.1016\/0363-5023(92)90408-H.","journal-title":"J Hand Surg Am."},{"issue":"1","key":"4200_CR20","doi-asserted-by":"publisher","first-page":"120","DOI":"10.4055\/cios.2019.11.1.120","volume":"11","author":"JR Oh","year":"2019","unstructured":"Oh JR, Kim DS, Yeom JS, Kang SK, Kim YT. A comparative study of tensile strength of three operative fixation techniques for metacarpal shaft fractures in adults: a cadaver study. Clin Orthop Surg. 2019;11(1):120\u20136. https:\/\/doi.org\/10.4055\/cios.2019.11.1.120.","journal-title":"Clin Orthop Surg"},{"key":"4200_CR21","doi-asserted-by":"crossref","unstructured":"Dunleavy ML, Candela X, Darowish M. Morphological Analysis of Metacarpal Shafts With Respect to Retrograde Intramedullary Headless Screw Fixation. Hand (New York, N,Y). 2020:1558944720937362. [Epub ahead of print]","DOI":"10.1177\/1558944720937362"},{"key":"4200_CR22","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1016\/j.jhsa.2012.09.029","volume":"38","author":"PWL ten Berg","year":"2013","unstructured":"ten Berg PWL, Mudgal CS, Leibman MI, Belsky MR, Ruchelsman DE. Quantitative 3-dimensional CT analyses of intramedullary headless screw fixation for metacarpal neck fractures. J Hand Surg Am. 2013;38:322.","journal-title":"J Hand Surg Am"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-021-04200-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12891-021-04200-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-021-04200-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,7]],"date-time":"2021-04-07T06:03:22Z","timestamp":1617775402000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-021-04200-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4,7]]},"references-count":22,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["4200"],"URL":"https:\/\/doi.org\/10.1186\/s12891-021-04200-0","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,4,7]]},"assertion":[{"value":"23 November 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 March 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 April 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The biomechanics portion of the above study was conducted using only de-identified cadaveric specimens and is therefore not considered human subjects research. The study was reported via Human Research Determination Form to the institutional review board (IRB) of the University of Connecticut and it was documented, that no IRB approval was required While this form does not require IRB review, we have confirmed with our IRB that projects conducted in our biomechanics laboratory that utilize de-identified specimens does not constitute human subjects research and therefore no review required. No consent was required for the biomechanical study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"No consent for publication was needed, because of the de-identified data.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The following authors declare that they have no competing interests:DMA, RY, DL, SO, MPC, EO, CMR.The following authors declare that they have competing interests:- FGED received finical support from the German Research Foundation (DFG) and the Westf\u00e4lische Wilhelms-Universit\u00e4t M\u00fcnster (WWU) for publication of this manuscript (processing fee).- ADM received research funding from Arthrex Inc., (Naples, Fl, USA).None of the authors have non-financial competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"335"}}