{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,10]],"date-time":"2026-02-10T20:11:02Z","timestamp":1770754262926,"version":"3.50.0"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,4,20]],"date-time":"2021-04-20T00:00:00Z","timestamp":1618876800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2021,4,20]],"date-time":"2021-04-20T00:00:00Z","timestamp":1618876800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>With regard to biomechanical testing of orthopaedic implants, there is no consensus on whether artificial creation of standardized bone fractures or their simulation by means of osteotomies result in more realistic outcomes. Therefore, the aim of this study was to artificially create and analyze in an appropriate setting the biomechanical behavior of standardized stable pertrochanteric fractures versus their simulation via osteotomizing.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Eight pairs of fresh-frozen human cadaveric femora aged 72.7\u00a0\u00b1\u00a014.9 years (range 48\u201389 years) were assigned in paired fashion to two study groups. In Group 1, stable pertrochanteric fractures AO\/OTA 31-A1 were artificially created via constant force application on the anterior cortex of the femur through a blunt guillotine blade. The same fracture type was simulated in Group 2 by means of osteotomies. All femora were implanted with a dynamic hip screw and biomechanically tested in 20\u00b0 adduction under progressively increasing physiologic\u00a0cyclic axial loading at 2\u00a0Hz, starting at 500\u00a0N and increasing at a rate of 0.1\u00a0N\/cycle. Femoral head fragment movements with respect to the shaft were monitored by means of optical motion tracking.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Cycles\/failure load at 15\u00b0 varus deformation, 10\u00a0mm leg shortening and 15\u00b0 femoral head rotation around neck axis were 11324\u00a0\u00b1\u00a0848\/1632.4\u00a0\u00b1\u00a0584.8\u00a0N, 11052\u00a0\u00b1\u00a01573\/1605.2\u00a0\u00b1\u00a0657.3\u00a0N and 11849\u00a0\u00b1\u00a01120\/1684.9\u00a0\u00b1\u00a0612.0\u00a0N in Group 1, and 10971\u00a0\u00b1\u00a02019\/1597.1\u00a0\u00b1\u00a0701.9\u00a0N, 10681\u00a0\u00b1\u00a01868\/1568.1\u00a0\u00b1\u00a0686.8\u00a0N and 10017\u00a0\u00b1\u00a04081\/1501.7\u00a0\u00b1\u00a0908.1\u00a0N in Group 2, respectively, with no significant differences between the two groups, <jats:italic>p<\/jats:italic> \u2265\u00a00.233.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>From a biomechanical perspective, by resulting in more consistent outcomes under dynamic loading, standardized artificial stable pertrochanteric femur fracture creation may be more suitable for orthopaedic implant testing compared to osteotomizing the bone.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-021-04234-4","type":"journal-article","created":{"date-parts":[[2021,4,20]],"date-time":"2021-04-20T17:49:28Z","timestamp":1618940968000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Standardized artificially created stable pertrochanteric femur fractures present more homogenous results compared to osteotomies for orthopaedic implant testing"],"prefix":"10.1186","volume":"22","author":[{"given":"J.F.","family":"Schader","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"I.","family":"Zderic","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.","family":"Gehweiler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Dauwe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K.","family":"Mys","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Danker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Y. P.","family":"Acklin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Sommer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.","family":"Gueorguiev","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K.","family":"Stoffel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,4,20]]},"reference":[{"issue":"9","key":"4234_CR1","doi-asserted-by":"publisher","first-page":"848","DOI":"10.1056\/NEJMhle1113918","volume":"366","author":"DB Kramer","year":"2012","unstructured":"Kramer DB, Xu S, Kesselheim AS. Regulation of medical devices in the United States and European Union. N Engl J Med. 2012;366(9):848\u201355.","journal-title":"N Engl J Med"},{"issue":"10","key":"4234_CR2","doi-asserted-by":"publisher","first-page":"e021650","DOI":"10.1136\/bmjopen-2018-021650","volume":"8","author":"F Henshaw","year":"2018","unstructured":"Henshaw F, Karasouli E, King R, Rahman U, Langton D, Madete J, et al. Engineering standards for trauma and orthopaedic implants worldwide: a systematic review protocol. BMJ Open. 2018;8(10):e021650.","journal-title":"BMJ Open"},{"issue":"7","key":"4234_CR3","doi-asserted-by":"publisher","first-page":"e12845","DOI":"10.2196\/12845","volume":"8","author":"A Panagopoulos","year":"2019","unstructured":"Panagopoulos A, Kyriakopoulos G, Anastopoulos G, Megas P, Kourkoulis SK. Design of Improved Intertrochanteric Fracture Treatment (DRIFT) Study: Protocol for Biomechanical Testing and Finite Element Analysis of Stable and Unstable Intertrochanteric Fractures Treated With Intramedullary Nailing or Dynamic Compression Screw. JMIR Res Protoc. 2019;8(7):e12845.","journal-title":"JMIR Res Protoc"},{"issue":"Suppl 2","key":"4234_CR4","first-page":"S-B37-50","volume":"31","author":"K Stoffel","year":"2000","unstructured":"Stoffel K, Klaue K, Perren SM. Functional load of plates in fracture fixation in vivo and its correlate in bone healing. Injury. 2000;31 Suppl 2:S-B37-50.","journal-title":"Injury"},{"issue":"3","key":"4234_CR5","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1016\/0020-1383(82)90134-6","volume":"14","author":"DE Ashhurst","year":"1982","unstructured":"Ashhurst DE, Hogg J, Perren SM. A method for making reproducible experimental fractures of the rabbit tibia. Injury. 1982;14(3):236\u201342.","journal-title":"Injury"},{"issue":"2","key":"4234_CR6","doi-asserted-by":"publisher","first-page":"177","DOI":"10.3109\/17453674.2014.887952","volume":"85","author":"K Wegmann","year":"2014","unstructured":"Wegmann K, Engel K, Burkhart KJ, Ebinger M, Holz R, Bruggemann GP, et al. Sequence of the Essex-Lopresti lesion\u2013a high-speed video documentation and kinematic analysis. Acta Orthop. 2014;85(2):177\u201380.","journal-title":"Acta Orthop"},{"issue":"3","key":"4234_CR7","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1359\/JBMR.0301247","volume":"19","author":"F Eckstein","year":"2004","unstructured":"Eckstein F, Wunderer C, Boehm H, Kuhn V, Priemel M, Link TM, et al. Reproducibility and side differences of mechanical tests for determining the structural strength of the proximal femur. J Bone Miner Res. 2004;19(3):379\u201385.","journal-title":"J Bone Miner Res"},{"issue":"13","key":"4234_CR8","doi-asserted-by":"publisher","first-page":"2837","DOI":"10.1016\/j.jbiomech.2007.03.015","volume":"40","author":"L Cristofolini","year":"2007","unstructured":"Cristofolini L, Juszczyk M, Martelli S, Taddei F, Viceconti M. In vitro replication of spontaneous fractures of the proximal human femur. J Biomech. 2007;40(13):2837\u201345.","journal-title":"J Biomech"},{"issue":"Suppl 1","key":"4234_CR9","first-page":"S1-S170","volume":"32","author":"EG Meinberg","year":"2018","unstructured":"Meinberg EG, Agel J, Roberts CS, Karam MD, Kellam JF. Fracture and Dislocation Classification Compendium-2018. J Orthop Trauma. 2018;32 Suppl 1:S1-S170.","journal-title":"J Orthop Trauma"},{"issue":"8","key":"4234_CR10","doi-asserted-by":"publisher","first-page":"713","DOI":"10.1016\/S0020-1383(02)00089-X","volume":"33","author":"H Pervez","year":"2002","unstructured":"Pervez H, Parker MJ, Pryor GA, Lutchman L, Chirodian N. Classification of trochanteric fracture of the proximal femur: a study of the reliability of current systems. Injury. 2002;33(8):713\u20135.","journal-title":"Injury"},{"issue":"7","key":"4234_CR11","doi-asserted-by":"publisher","first-page":"858","DOI":"10.1016\/j.injury.2005.02.005","volume":"36","author":"WJ Jin","year":"2005","unstructured":"Jin WJ, Dai LY, Cui YM, Zhou Q, Jiang LS, Lu H. Reliability of classification systems for intertrochanteric fractures of the proximal femur in experienced orthopaedic surgeons. Injury. 2005;36(7):858\u201361.","journal-title":"Injury"},{"issue":"2","key":"4234_CR12","first-page":"250","volume":"2","author":"D van Embden","year":"2015","unstructured":"van Embden D, Gaston MS, Bailey LA, Simpson AHR. Trochanteric femoral fracture classification: relevance of the fracture line angle, a radiological study. International Journal of Orthopaedics. 2015;2(2):250\u20135.","journal-title":"International Journal of Orthopaedics"},{"key":"4234_CR13","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1016\/j.bone.2018.06.006","volume":"114","author":"K Mys","year":"2018","unstructured":"Mys K, Stockmans F, Vereecke E, van Lenthe GH. Quantification of bone microstructure in the wrist using cone-beam computed tomography. Bone. 2018;114:206\u201314.","journal-title":"Bone"},{"issue":"10","key":"4234_CR14","doi-asserted-by":"publisher","first-page":"2154","DOI":"10.1002\/jor.23512","volume":"35","author":"D Gehweiler","year":"2017","unstructured":"Gehweiler D, Wahnert D, Meier N, Spruit M, Raschke MJ, Richards RG, et al. Computational anatomy of the dens axis evaluated by quantitative computed tomography: Implications for anterior screw fixation. J Orthop Res. 2017;35(10):2154\u201363.","journal-title":"J Orthop Res"},{"issue":"7","key":"4234_CR15","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1016\/S0021-9290(01)00040-9","volume":"34","author":"G Bergmann","year":"2001","unstructured":"Bergmann G, Deuretzbacher G, Heller M, Graichen F, Rohlmann A, Strauss J, et al. Hip contact forces and gait patterns from routine activities. J Biomech. 2001;34(7):859\u201371.","journal-title":"J Biomech"},{"issue":"5","key":"4234_CR16","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1007\/s00113-007-1248-0","volume":"110","author":"F Bonnaire","year":"2007","unstructured":"Bonnaire F, Weber A, Bosl O, Eckhardt C, Schwieger K, Linke B. [\u201cCutting out\u201d in pertrochanteric fractures\u2013problem of osteoporosis?]. Unfallchirurg. 2007;110(5):425\u201332.","journal-title":"Unfallchirurg"},{"issue":"1","key":"4234_CR17","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/j.clinbiomech.2008.07.004","volume":"24","author":"M Windolf","year":"2009","unstructured":"Windolf M, Braunstein V, Dutoit C, Schwieger K. Is a helical shaped implant a superior alternative to the Dynamic Hip Screw for unstable femoral neck fractures? A biomechanical investigation. Clin Biomech (Bristol, Avon). 2009;24(1):59\u201364.","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"6","key":"4234_CR18","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1097\/BOT.0b013e3182163345","volume":"25","author":"B Gueorguiev","year":"2011","unstructured":"Gueorguiev B, Ockert B, Schwieger K, Wahnert D, Lawson-Smith M, Windolf M, et al. Angular stability potentially permits fewer locking screws compared with conventional locking in intramedullary nailed distal tibia fractures: a biomechanical study. J Orthop Trauma. 2011;25(6):340\u20136.","journal-title":"J Orthop Trauma"},{"issue":"6","key":"4234_CR19","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1007\/s00113-011-1973-2","volume":"114","author":"F Bonnaire","year":"2011","unstructured":"Bonnaire F, Lein T, Bula P. [Trochanteric femoral fractures: anatomy, biomechanics and choice of implants]. Unfallchirurg. 2011;114(6):491\u2013500.","journal-title":"Unfallchirurg"},{"issue":"1","key":"4234_CR20","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1002\/jor.1100020115","volume":"2","author":"F Bonnarens","year":"1984","unstructured":"Bonnarens F, Einhorn TA. Production of a standard closed fracture in laboratory animal bone. J Orthop Res. 1984;2(1):97\u2013101.","journal-title":"J Orthop Res"},{"issue":"3","key":"4234_CR21","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1097\/00005131-199306000-00011","volume":"7","author":"R Brutscher","year":"1993","unstructured":"Brutscher R, Rahn BA, Ruter A, Perren SM. The role of corticotomy and osteotomy in the treatment of bone defects using the Ilizarov technique. J Orthop Trauma. 1993;7(3):261\u20139.","journal-title":"J Orthop Trauma"},{"issue":"Suppl 2","key":"4234_CR22","first-page":"S437-44","volume":"7","author":"J Cordey","year":"1992","unstructured":"Cordey J, Schneider M, Belendez C, Ziegler WJ, Rahn BA, Perren SM. Effect of bone size, not density, on the stiffness of the proximal part of normal and osteoporotic human femora. J Bone Miner Res. 1992;7 Suppl 2:S437-44.","journal-title":"J Bone Miner Res"},{"issue":"2","key":"4234_CR23","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1016\/j.injury.2016.12.015","volume":"48","author":"JW Cho","year":"2017","unstructured":"Cho JW, Kent WT, Yoon YC, Kim Y, Kim H, Jha A, et al. Fracture morphology of AO\/OTA 31-A trochanteric fractures: A 3D CT study with an emphasis on coronal fragments. Injury. 2017;48(2):277\u201384.","journal-title":"Injury"},{"issue":"1","key":"4234_CR24","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1002\/jor.22478","volume":"32","author":"M Gebauer","year":"2014","unstructured":"Gebauer M, Stark O, Vettorazzi E, Grifka J, Puschel K, Amling M, et al. DXA and pQCT predict pertrochanteric and not femoral neck fracture load in a human side-impact fracture model. J Orthop Res. 2014;32(1):31\u20138.","journal-title":"J Orthop Res"},{"issue":"5","key":"4234_CR25","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1097\/00005131-200006000-00002","volume":"14","author":"SW McLoughlin","year":"2000","unstructured":"McLoughlin SW, Wheeler DL, Rider J, Bolhofner B. Biomechanical evaluation of the dynamic hip screw with two- and four-hole side plates. J Orthop Trauma. 2000;14(5):318\u201323.","journal-title":"J Orthop Trauma"},{"issue":"5","key":"4234_CR26","doi-asserted-by":"publisher","first-page":"807","DOI":"10.1016\/j.jbiomech.2014.12.008","volume":"48","author":"JA Steiner","year":"2015","unstructured":"Steiner JA, Ferguson SJ, van Lenthe GH. Computational analysis of primary implant stability in trabecular bone. Journal of Biomechanics. 2015;48(5):807\u201315.","journal-title":"Journal of Biomechanics"},{"issue":"2","key":"4234_CR27","doi-asserted-by":"publisher","first-page":"536","DOI":"10.1016\/j.jbiomech.2013.10.033","volume":"47","author":"AA Ali","year":"2014","unstructured":"Ali AA, Cristofolini L, Schileo E, Hu H, Taddei F, Kim RH, et al. Specimen-specific modeling of hip fracture pattern and repair. J Biomech. 2014;47(2):536\u201343.","journal-title":"J Biomech"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-021-04234-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-021-04234-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-021-04234-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,20]],"date-time":"2021-04-20T17:50:06Z","timestamp":1618941006000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-021-04234-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4,20]]},"references-count":27,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["4234"],"URL":"https:\/\/doi.org\/10.1186\/s12891-021-04234-4","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,4,20]]},"assertion":[{"value":"9 December 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 April 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 April 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures performed in this study were followed in accordance with relevant guidelines. The specimens for this study were collected from an accredited donation program (Science Care, Inc., Phoenix, AZ, USA). All donors gave their informed consent inherent within the donation of the anatomical gift statement during their lifetime, as registered by Science Care. This study was approved by the institutional internal review board, based on the approval of the specimens\u2019 delivery by Science Care Ethics Committee.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"371"}}