{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T12:16:24Z","timestamp":1767183384874,"version":"3.37.3"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,1,7]],"date-time":"2022-01-07T00:00:00Z","timestamp":1641513600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,1,7]],"date-time":"2022-01-07T00:00:00Z","timestamp":1641513600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100018842","name":"Deutsche Arthrose-Hilfe e.V.","doi-asserted-by":"crossref","award":["P400-A687-Josten-EP6-zajo2-h\u00fcfte-op-l-10k-2017-18"],"award-info":[{"award-number":["P400-A687-Josten-EP6-zajo2-h\u00fcfte-op-l-10k-2017-18"]}],"id":[{"id":"10.13039\/100018842","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100008678","name":"Universit\u00e4t Leipzig","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100008678","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>Intraoperative proximal femoral fractures (IPFF) are relevant complications during total hip arthroplasty. Fixation using cerclage wires (CW) represents a minimally-invasive technique to address these fractures through the same surgical approach. The goal of treatment is to mobilise the patient as early as possible, which requires high primary stability. This study aimed to compare different cerclage wire configurations fixing IPFF with regard to biomechanical primary stability.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Standardised IPFF (type II, Modified Mallory Classification) were created in human fresh frozen femora and were fixed either by two or three CW (1.6\u2009mm, stainless steel). All cadaveric specimens (<jats:italic>n<\/jats:italic>\u2009=\u200942) were randomised to different groups (quasi-static, dynamic) or subgroups (2 CW, 3 CW) stratified by bone mineral density determined by Dual Energy X-ray Absorptiometry. Using a biomechanical testing setup, quasi-static and dynamic cyclic failure tests were carried out. Cyclic loading started from 200\u2009N to 500\u2009N at 1\u2009Hz with increasing peak load by 250\u2009N every 100\u2009cycles until failure occurred or maximum load (5250\u2009N) reached. The change of fracture gap size was optically captured.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>No significant differences in failure load after quasi-static (<jats:italic>p<\/jats:italic>\u2009=\u20090.701) or dynamic cyclic loading (<jats:italic>p<\/jats:italic>\u2009=\u20090.132) were found between the experimental groups. In the quasi-static load testing, all constructs resisted 250% of the body weight (BW) of their corresponding body donor. In the dynamic cyclic load testing, all but one construct (treated by 3 CW) resisted 250% BW.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Based on this in vitro data, both two and three CW provided sufficient primary stability according to the predefined minimum failure load (250% BW) to resist. The authors recommend the treatment using two CW because it reduces the risk of vascular injury and shortens procedure time.<\/jats:p><\/jats:sec>","DOI":"10.1186\/s12891-021-04956-5","type":"journal-article","created":{"date-parts":[[2022,1,7]],"date-time":"2022-01-07T19:02:48Z","timestamp":1641582168000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Fixation of intraoperative proximal femoral fractures during THA using two versus three cerclage wires - a biomechanical study"],"prefix":"10.1186","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7890-178X","authenticated-orcid":false,"given":"Toni","family":"Wendler","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Melanie","family":"Edel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert","family":"M\u00f6bius","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Johannes","family":"Fakler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Georg","family":"Osterhoff","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dirk","family":"Zajonz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,1,7]]},"reference":[{"key":"4956_CR1","doi-asserted-by":"publisher","first-page":"1508","DOI":"10.1016\/S0140-6736(07)60457-7","volume":"370","author":"ID Learmonth","year":"2007","unstructured":"Learmonth ID, Young C, Rorabeck C. The operation of the century: total hip replacement. Lancet. 2007;370:1508\u201319. https:\/\/doi.org\/10.1016\/S0140-6736(07)60457-7.","journal-title":"Lancet"},{"key":"4956_CR2","doi-asserted-by":"publisher","first-page":"e281","DOI":"10.3928\/01477447-20161116-06","volume":"40","author":"R Zhao","year":"2017","unstructured":"Zhao R, Cai H, Liu Y, Tian H, Zhang K, Liu Z. Risk factors for intraoperative proximal femoral fracture during primary Cementless THA. Orthopedics. 2017;40:e281\u20137. https:\/\/doi.org\/10.3928\/01477447-20161116-06.","journal-title":"Orthopedics"},{"key":"4956_CR3","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1186\/s13037-016-0114-9","volume":"10","author":"WR Smith","year":"2016","unstructured":"Smith WR, Stoneback JW, Morgan SJ, Stahel PF. Is immediate weight bearing safe for periprosthetic distal femur fractures treated by locked plating? A feasibility study in 52 consecutive patients. Patient Saf Surg. 2016;10:26. https:\/\/doi.org\/10.1186\/s13037-016-0114-9.","journal-title":"Patient Saf Surg"},{"key":"4956_CR4","doi-asserted-by":"publisher","first-page":"2045","DOI":"10.1007\/s11999-014-4077-9","volume":"473","author":"CD Watts","year":"2015","unstructured":"Watts CD, Abdel MP, Lewallen DG, Berry DJ, Hanssen AD. Increased risk of periprosthetic femur fractures associated with a unique cementless stem design. Clin Orthop Relat Res. 2015;473:2045\u201353. https:\/\/doi.org\/10.1007\/s11999-014-4077-9.","journal-title":"Clin Orthop Relat Res"},{"key":"4956_CR5","doi-asserted-by":"publisher","unstructured":"Masri BA, Meek RMD, Duncan CP. Periprosthetic fractures evaluation and treatment. Clin Orthop Relat Res. 2004:80\u201395. https:\/\/doi.org\/10.1097\/00003086-200403000-00012.","DOI":"10.1097\/00003086-200403000-00012"},{"key":"4956_CR6","first-page":"59","volume":"77","author":"M Nowak","year":"2012","unstructured":"Nowak M, Kusz D, Wojciechowski P, Wilk R. Risk factors for intraoperative periprosthetic femoral fractures during the total hip arthroplasty. Pol Orthop Traumatol. 2012;77:59\u201364.","journal-title":"Pol Orthop Traumatol"},{"key":"4956_CR7","doi-asserted-by":"publisher","first-page":"1400","DOI":"10.1016\/j.arth.2019.03.031","volume":"34","author":"B Liu","year":"2019","unstructured":"Liu B, Ma W, Li H, Wu T, Huo J, Han Y. Incidence, classification, and risk factors for intraoperative periprosthetic femoral fractures in patients undergoing total hip arthroplasty with a single stem: a retrospective study. J Arthroplast. 2019;34:1400\u201311. https:\/\/doi.org\/10.1016\/j.arth.2019.03.031.","journal-title":"J Arthroplast"},{"key":"4956_CR8","doi-asserted-by":"publisher","first-page":"1291","DOI":"10.1007\/s00590-018-2217-8","volume":"28","author":"C Timmer","year":"2018","unstructured":"Timmer C, Gerhardt DMJM, de Visser E, de Kleuver M, van Susante JLC. High incidence of intraoperative calcar fractures with the cementless CLS Spotorno stem. Eur J Orthop Surg Traumatol. 2018;28:1291\u20136. https:\/\/doi.org\/10.1007\/s00590-018-2217-8.","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"4956_CR9","doi-asserted-by":"publisher","first-page":"1418","DOI":"10.1016\/j.arth.2015.02.043","volume":"30","author":"DY Ponzio","year":"2015","unstructured":"Ponzio DY, Shahi A, Park AG, Purtill JJ. Intraoperative proximal femoral fracture in primary cementless total hip arthroplasty. J Arthroplast. 2015;30:1418\u201322. https:\/\/doi.org\/10.1016\/j.arth.2015.02.043.","journal-title":"J Arthroplast"},{"key":"4956_CR10","doi-asserted-by":"crossref","first-page":"194","DOI":"10.55095\/achot2010\/040","volume":"77","author":"T Tom\u00e1s","year":"2010","unstructured":"Tom\u00e1s T, Nachtnebl L, Otiepka P. Distal femoral periprosthetic fractures: classification and therapy. [distal femoral periprosthetic fractures: classification and therapy]. Acta Chir Orthop Traumatol Cechoslov. 2010;77:194\u2013202.","journal-title":"Acta Chir Orthop Traumatol Cechoslov"},{"key":"4956_CR11","doi-asserted-by":"publisher","first-page":"2131","DOI":"10.1007\/s11999-014-4078-8","volume":"473","author":"KJ Bozic","year":"2015","unstructured":"Bozic KJ, Kamath AF, Ong K, Lau E, Kurtz S, Chan V, et al. Comparative epidemiology of revision arthroplasty: failed THA poses greater clinical and economic burdens than failed TKA. Clin Orthop Relat Res. 2015;473:2131\u20138. https:\/\/doi.org\/10.1007\/s11999-014-4078-8.","journal-title":"Clin Orthop Relat Res"},{"key":"4956_CR12","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1111\/jth.14367","volume":"17","author":"D Horner","year":"2019","unstructured":"Horner D, Pandor A, Goodacre S, Clowes M, Hunt BJ. Individual risk factors predictive of venous thromboembolism in patients with temporary lower limb immobilization due to injury: a systematic review. J Thromb Haemost. 2019;17:329\u201344. https:\/\/doi.org\/10.1111\/jth.14367.","journal-title":"J Thromb Haemost"},{"key":"4956_CR13","doi-asserted-by":"publisher","first-page":"189","DOI":"10.11138\/ccmbm\/2017.14.1.189","volume":"14","author":"A Capone","year":"2017","unstructured":"Capone A, Congia S, Civinini R, Marongiu G. Periprosthetic fractures: epidemiology and current treatment. Clin Cases Miner Bone Metab. 2017;14:189\u201396. https:\/\/doi.org\/10.11138\/ccmbm\/2017.14.1.189.","journal-title":"Clin Cases Miner Bone Metab"},{"key":"4956_CR14","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1016\/j.arth.2004.06.008","volume":"19","author":"KR Berend","year":"2004","unstructured":"Berend KR, Lombardi AV, Mallory TH, Chonko DJ, Dodds KL, Adams JB. Cerclage wires or cables for the management of intraoperative fracture associated with a cementless, tapered femoral prosthesis: results at 2 to 16 years. J Arthroplast. 2004;19:17\u201321. https:\/\/doi.org\/10.1016\/j.arth.2004.06.008.","journal-title":"J Arthroplast"},{"key":"4956_CR15","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1007\/s00590-014-1520-2","volume":"25","author":"A Angelini","year":"2015","unstructured":"Angelini A, Battiato C. Past and present of the use of cerclage wires in orthopedics. Eur J Orthop Surg Traumatol. 2015;25:623\u201335. https:\/\/doi.org\/10.1007\/s00590-014-1520-2.","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"4956_CR16","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1016\/j.injury.2012.10.016","volume":"44","author":"T Apivatthakakul","year":"2013","unstructured":"Apivatthakakul T, Phaliphot J, Leuvitoonvechkit S. Percutaneous cerclage wiring, does it disrupt femoral blood supply? A cadaveric injection study. Injury. 2013;44:168\u201374. https:\/\/doi.org\/10.1016\/j.injury.2012.10.016.","journal-title":"Injury"},{"key":"4956_CR17","doi-asserted-by":"publisher","first-page":"544","DOI":"10.1177\/1120700019849911","volume":"30","author":"T Ferbert","year":"2020","unstructured":"Ferbert T, Jaber A, Gress N, Schmidmaier G, Gotterbarm T, Merle C. Impact of intraoperative femoral fractures in primary hip arthroplasty: a comparative study with a mid-term follow-up. Hip Int. 2020;30:544\u201351. https:\/\/doi.org\/10.1177\/1120700019849911.","journal-title":"Hip Int"},{"key":"4956_CR18","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1111\/j.1532-950X.2011.00858.x","volume":"41","author":"RS McCulloch","year":"2012","unstructured":"McCulloch RS, Roe SC, Marcellin-Little DJ, Mente PL. Resistance to subsidence of an uncemented femoral stem after cerclage wiring of a fissure. Vet Surg. 2012;41:163\u20137. https:\/\/doi.org\/10.1111\/j.1532-950X.2011.00858.x.","journal-title":"Vet Surg"},{"key":"4956_CR19","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1016\/S0883-5403(99)90209-7","volume":"14","author":"Z Fishkin","year":"1999","unstructured":"Fishkin Z, Han S-M, Ziv I. Cerclage wiring technique after proximal femoral fracture in total hip arthroplasty. J Arthroplast. 1999;14:98\u2013101. https:\/\/doi.org\/10.1016\/S0883-5403(99)90209-7.","journal-title":"J Arthroplast"},{"key":"4956_CR20","doi-asserted-by":"publisher","first-page":"571","DOI":"10.1007\/s007760100014","volume":"6","author":"T Yamaji","year":"2001","unstructured":"Yamaji T, Ando K, Wolf S, Augat P, Claes L. The effect of micromovement on callus formation. J Orthop Sci. 2001;6:571\u20135. https:\/\/doi.org\/10.1007\/s007760100014.","journal-title":"J Orthop Sci"},{"key":"4956_CR21","volume-title":"OrthoLoad","author":"G Bergmann","year":"2008","unstructured":"Bergmann G. OrthoLoad. 2008. http:\/\/www.OrthoLoad.com. Accessed 25 Nov 2020."},{"key":"4956_CR22","doi-asserted-by":"publisher","first-page":"65","DOI":"10.3233\/BME-2010-0616","volume":"20","author":"G Bergmann","year":"2010","unstructured":"Bergmann G, Graichen F, Rohlmann A, Bender A, Heinlein B, Duda GN, et al. Realistic loads for testing hip implants. Biomed Mater Eng. 2010;20:65\u201375. https:\/\/doi.org\/10.3233\/BME-2010-0616.","journal-title":"Biomed Mater Eng"},{"key":"4956_CR23","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1016\/S0021-9290(01)00040-9","volume":"34","author":"G Bergmann","year":"2001","unstructured":"Bergmann G, Deuretzbacher G, Heller M, Graichen F, Rohlmann A, Strauss J, et al. Hip contact forces and gait patterns from routine activities. J Biomech. 2001;34:859\u201371. https:\/\/doi.org\/10.1016\/S0021-9290(01)00040-9.","journal-title":"J Biomech"},{"key":"4956_CR24","doi-asserted-by":"publisher","first-page":"e0155612","DOI":"10.1371\/journal.pone.0155612","volume":"11","author":"G Bergmann","year":"2016","unstructured":"Bergmann G, Bender A, Dymke J, Duda G, Damm P, P\u00e9rez MA. Standardized loads acting in hip implants. Plos One. 2016;11:e0155612. https:\/\/doi.org\/10.1371\/journal.pone.0155612.","journal-title":"Plos One"},{"key":"4956_CR25","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1016\/j.jbiomech.2016.11.060","volume":"51","author":"P Damm","year":"2017","unstructured":"Damm P, Kutzner I, Bergmann G, Rohlmann A, Schmidt H. Comparison of in vivo measured loads in knee, hip and spinal implants during level walking. J Biomech. 2017;51:128\u201332. https:\/\/doi.org\/10.1016\/j.jbiomech.2016.11.060.","journal-title":"J Biomech"},{"key":"4956_CR26","doi-asserted-by":"publisher","first-page":"39","DOI":"10.13107\/jocr.2250-0685.842","volume":"7","author":"S Agarwala","year":"2017","unstructured":"Agarwala S, Menon A, Chaudhari S. Cerclage wiring as an adjunct for the treatment of femur fractures: series of 11 cases. J Orthop Case Rep. 2017;7:39\u201343. https:\/\/doi.org\/10.13107\/jocr.2250-0685.842.","journal-title":"J Orthop Case Rep"},{"key":"4956_CR27","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1111\/os.12052","volume":"5","author":"NA Ebraheim","year":"2013","unstructured":"Ebraheim NA, Sochacki KR, Liu X, Hirschfeld AG, Liu J. Locking plate fixation of periprosthetic femur fractures with and without cerclage wires. Orthop Surg. 2013;5:183\u20137. https:\/\/doi.org\/10.1111\/os.12052.","journal-title":"Orthop Surg"},{"key":"4956_CR28","doi-asserted-by":"crossref","first-page":"190","DOI":"10.55095\/achot2011\/031","volume":"78","author":"SM Perren","year":"2011","unstructured":"Perren SM, Fernandez Dell'Oca A, Lenz M, Windolf M. Cerclage, evolution and potential of a Cinderella technology. An overview with reference to periprosthetic fractures. Acta Chir Orthop Traumatol Cechoslov. 2011;78:190\u20139.","journal-title":"Acta Chir Orthop Traumatol Cechoslov"},{"key":"4956_CR29","doi-asserted-by":"publisher","first-page":"3002","DOI":"10.1016\/j.arth.2020.05.041","volume":"35","author":"C-W Park","year":"2020","unstructured":"Park C-W, Lim S-J, Ye D-H, Park Y-S. Outcomes of cerclage cabling for intraoperative calcar cracks in cementless total hip arthroplasty using broach-only, tapered wedge stems. J Arthroplast. 2020;35:3002\u20139. https:\/\/doi.org\/10.1016\/j.arth.2020.05.041.","journal-title":"J Arthroplast"},{"key":"4956_CR30","doi-asserted-by":"publisher","first-page":"1449","DOI":"10.1016\/j.arth.2015.02.026","volume":"30","author":"NB Frisch","year":"2015","unstructured":"Frisch NB, Charters MA, Sikora-Klak J, Banglmaier RF, Oravec DJ, Silverton CD. Intraoperative periprosthetic femur fracture: a biomechanical analysis of cerclage fixation. J Arthroplast. 2015;30:1449\u201357. https:\/\/doi.org\/10.1016\/j.arth.2015.02.026.","journal-title":"J Arthroplast"},{"key":"4956_CR31","doi-asserted-by":"publisher","first-page":"3898","DOI":"10.1016\/j.jbiomech.2014.10.025","volume":"47","author":"T Basso","year":"2014","unstructured":"Basso T, Klaksvik J, Syversen U, Foss OA. A biomechanical comparison of composite femurs and cadaver femurs used in experiments on operated hip fractures. J Biomech. 2014;47:3898\u2013902. https:\/\/doi.org\/10.1016\/j.jbiomech.2014.10.025.","journal-title":"J Biomech"},{"key":"4956_CR32","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1016\/j.otsr.2017.10.020","volume":"104","author":"M Ehlinger","year":"2018","unstructured":"Ehlinger M, Niglis L, Favreau H, Kuntz S, Bierry G, Adam P, et al. Vascular complication after percutaneous femoral cerclage wire. Orthop Traumatol Surg Res. 2018;104:377\u201381. https:\/\/doi.org\/10.1016\/j.otsr.2017.10.020.","journal-title":"Orthop Traumatol Surg Res"},{"key":"4956_CR33","first-page":"28","volume":"86","author":"S Fauconnier","year":"2020","unstructured":"Fauconnier S, van Lieshout M, Victor J. Evaluation of cerclage wiring in the treatment of subtrochanteric fractures. Acta Orthop Belg. 2020;86:28\u201332.","journal-title":"Acta Orthop Belg"},{"key":"4956_CR34","doi-asserted-by":"publisher","first-page":"849","DOI":"10.1007\/s00402-008-0676-9","volume":"129","author":"E Jakubowitz","year":"2009","unstructured":"Jakubowitz E, Seeger JB, Lee C, Heisel C, Kretzer JP, Thomsen MN. Do short-stemmed-prostheses induce periprosthetic fractures earlier than standard hip stems? A biomechanical ex-vivo study of two different stem designs. Arch Orthop Trauma Surg. 2009;129:849\u201355. https:\/\/doi.org\/10.1007\/s00402-008-0676-9.","journal-title":"Arch Orthop Trauma Surg"},{"key":"4956_CR35","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1016\/j.orthres.2003.11.007","volume":"22","author":"R Hente","year":"2004","unstructured":"Hente R, F\u00fcchtmeier B, Schlegel U, Ernstberger A, Perren SM. The influence of cyclic compression and distraction on the healing of experimental tibial fractures. J Orthop Res. 2004;22:709\u201315. https:\/\/doi.org\/10.1016\/j.orthres.2003.11.007.","journal-title":"J Orthop Res"},{"issue":"Suppl 6","key":"4956_CR36","doi-asserted-by":"publisher","first-page":"S27","DOI":"10.1016\/j.injury.2014.10.019","volume":"45","author":"G Vicenti","year":"2014","unstructured":"Vicenti G, Pesce V, Tartaglia N, Abate A, Mori CM, Moretti B. Micromotion in the fracture healing of closed distal metaphyseal tibial fractures: a multicentre prospective study. Injury. 2014;45(Suppl 6):S27\u201335. https:\/\/doi.org\/10.1016\/j.injury.2014.10.019.","journal-title":"Injury"},{"key":"4956_CR37","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1016\/S0736-0266(02)00259-0","volume":"21","author":"P Klein","year":"2003","unstructured":"Klein P, Schell H, Streitparth F, Heller M, Kassi J-P, Kandziora F, et al. The initial phase of fracture healing is specifically sensitive to mechanical conditions. J Orthop Res. 2003;21:662\u20139. https:\/\/doi.org\/10.1016\/S0736-0266(02)00259-0.","journal-title":"J Orthop Res"},{"key":"4956_CR38","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1016\/j.jor.2016.06.002","volume":"13","author":"R Karuppal","year":"2016","unstructured":"Karuppal R. Biological fixation of total hip arthroplasty: facts and factors. J Orthop. 2016;13:190\u20132. https:\/\/doi.org\/10.1016\/j.jor.2016.06.002.","journal-title":"J Orthop"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-021-04956-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-021-04956-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-021-04956-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,15]],"date-time":"2023-11-15T14:13:25Z","timestamp":1700057605000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-021-04956-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,7]]},"references-count":38,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["4956"],"URL":"https:\/\/doi.org\/10.1186\/s12891-021-04956-5","relation":{},"ISSN":["1471-2474"],"issn-type":[{"type":"electronic","value":"1471-2474"}],"subject":[],"published":{"date-parts":[[2022,1,7]]},"assertion":[{"value":"3 June 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 December 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 January 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All femora originated from the Institute of Anatomy of the Leipzig University. The body donors had given written consent to dedicate their bodies to medical education and research purposes. Being part of the body donor program regulated by the Saxonian Death and Funeral Act of 1994 (3rd section, paragraph\u00a018, item 8), institutional approval for the use of the post-mortem tissues of human body donors was obtained. Thus, additional separate approval by the Ethics Committee of the Medical Faculty of the Leipzig University was not necessary. The authors declare that all experiments were performed according to the ethical principles of the Declaration of Helsinki and all relevant national regulations.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"GO is Associate Editor for BMC Muskuloskeletal Disorders. The authors declare that they have no conflict of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"40"}}