{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,16]],"date-time":"2026-11-16T15:23:55Z","timestamp":1794842635503,"version":"4.9.1"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,1,3]],"date-time":"2022-01-03T00:00:00Z","timestamp":1641168000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,1,3]],"date-time":"2022-01-03T00:00:00Z","timestamp":1641168000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Introduction<\/jats:title>\n                <jats:p>The volar locking plate has been widely used for unstable distal radius fractures to provide early recovery of wrist function. Volar plate prominence to the watershed line has been reported to be related to flexor tendon irritation, and avoid implant prominence in this area was suggested. On the other hand, marginal distal radius fracture patterns required the plate to cross the watershed line, making conflict over plate positioning on marginal distal radius fractures. This study compared functional outcomes in patients with marginal distal radius fractures treated with two different implants.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Materials and methods<\/jats:title>\n                <jats:p>A retrospective study was conducted, all patients who received a Synthes 2.4\u2009mm LCP or an Acumed Acu-Loc VLP between January 2015 and December 2018 were reviewed. The marginal distal radius fracture pattern was the most distal horizontal fracture line within 10\u2009mm of the lunate fossa\u2019s joint line. The primary outcomes including patient-reported pain scores, range of motion, and grip strength were assessed. Secondary outcomes included patient-based subjective satisfaction scores of the injured wrist and hand function. The Mayo Wrist Score and the requirement for a secondary procedure related to hardware complications were also recorded.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Forty-two patients met our inclusion criteria. Twenty-one patients were treated with the Synthes 2.4\u2009mm LCP, and 21 patients with the Acumed Acu-Loc VLP. The primary outcome revealed that post-operative range of motion (<jats:italic>P<\/jats:italic>\u2009=\u20090.016) and grip strengths (<jats:italic>P<\/jats:italic>\u2009=\u20090.014) were significantly improved in the Acu-Loc VLP group. The MAYO wrist score in the Acu-Loc VLP group was also significantly better (<jats:italic>P<\/jats:italic>\u2009=\u20090.006).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Despite advances in implant designs, flexor tendon irritation or rupture is still a complication following distal radius\u2019s volar plating. We believe the Acumed Acu-Loc VLP design provided better functional outcomes than the Synthes 2.4\u2009mm LCP if appropriately and carefully placed into its designed-for position. This positioning results in promising patient satisfaction when treating marginal distal radius fractures.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-021-04984-1","type":"journal-article","created":{"date-parts":[[2022,1,3]],"date-time":"2022-01-03T17:02:57Z","timestamp":1641229377000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Functional outcomes following fixation of a marginal distal radius fracture with two commonly used volar locking plates: a retrospective cohort study"],"prefix":"10.1186","volume":"23","author":[{"given":"Yin-Ming","family":"Huang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chun-Yu","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kai-Cheng","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yih-Wen","family":"Tarng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ching-Yi","family":"Liao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei-Ning","family":"Chang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,1,3]]},"reference":[{"issue":"6","key":"4984_CR1","doi-asserted-by":"publisher","first-page":"623","DOI":"10.1097\/SAP.0000000000000850","volume":"77","author":"R Mehrzad","year":"2016","unstructured":"Mehrzad R, Kim DC. Complication rate comparing variable angle distal locking plate to fixed angle plate fixation of distal radius fractures. Ann Plast Surg. 2016;77(6):623\u20135.","journal-title":"Ann Plast Surg"},{"issue":"Suppl 5","key":"4984_CR2","doi-asserted-by":"publisher","first-page":"S41","DOI":"10.1016\/S0020-1383(17)30738-6","volume":"48","author":"J Kne\u017eevi\u0107","year":"2017","unstructured":"Kne\u017eevi\u0107 J, Kodvanj J, \u010cukelj F, Pamukovi\u0107 F, Pavi\u0107 A. A biomechanical comparison of four fixed-angle dorsal plates in a finite element model of dorsally-unstable radius fracture. Injury. 2017;48(Suppl 5):S41\u2013s6.","journal-title":"Injury."},{"issue":"1","key":"4984_CR3","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1097\/JTN.0000000000000416","volume":"26","author":"R Heidgerd","year":"2019","unstructured":"Heidgerd R, Morgan J, Schentrup D. Evaluation of functional outcomes for adult patients after distal radius fracture treated with volar plate fixation versus nonsurgical care. J Trauma Nurs. 2019;26(1):59\u201364.","journal-title":"J Trauma Nurs"},{"issue":"5","key":"4984_CR4","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1007\/s00402-020-03405-7","volume":"140","author":"W Hintringer","year":"2020","unstructured":"Hintringer W, Rosenauer R, Pezzei C, Quadlbauer S, Jurkowitsch J, Keuchel T, et al. Biomechanical considerations on a CT-based treatment-oriented classification in radius fractures. Arch Orthop Trauma Surg. 2020;140(5):595\u2013609.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"5","key":"4984_CR5","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1007\/s00402-020-03365-y","volume":"140","author":"M Leixnering","year":"2020","unstructured":"Leixnering M, Rosenauer R, Pezzei C, Jurkowitsch J, Beer T, Keuchel T, et al. Indications, surgical approach, reduction, and stabilization techniques of distal radius fractures. Arch Orthop Trauma Surg. 2020;140(5):611\u201321.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"5","key":"4984_CR6","doi-asserted-by":"publisher","first-page":"852","DOI":"10.1016\/j.jhsa.2014.01.038","volume":"39","author":"R Limthongthang","year":"2014","unstructured":"Limthongthang R, Bachoura A, Jacoby SM, Osterman AL. Distal radius volar locking plate design and associated vulnerability of the flexor pollicis longus. J Hand Surg Am. 2014;39(5):852\u201360.","journal-title":"J Hand Surg Am"},{"issue":"2","key":"4984_CR7","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1142\/S0218810400000223","volume":"5","author":"JL Orbay","year":"2000","unstructured":"Orbay JL. The treatment of unstable distal radius fractures with volar fixation. Hand Surg. 2000;5(2):103\u201312.","journal-title":"Hand Surg"},{"issue":"2","key":"4984_CR8","first-page":"102","volume":"6","author":"S Quadlbauer","year":"2017","unstructured":"Quadlbauer S, Pezzei C, Jurkowitsch J, Kolmayr B, Keuchel T, Simon D, et al. Early rehabilitation of distal radius fractures stabilized by volar locking plate: a prospective randomized pilot study. J Wrist Surg. 2017;6(2):102\u201312.","journal-title":"J Wrist Surg."},{"issue":"6","key":"4984_CR9","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1007\/s00402-020-03411-9","volume":"140","author":"S Quadlbauer","year":"2020","unstructured":"Quadlbauer S, Pezzei C, Jurkowitsch J, Rosenauer R, Pichler A, Sch\u00e4ttin S, et al. Functional and radiological outcome of distal radius fractures stabilized by volar-locking plate with a minimum follow-up of 1 year. Arch Orthop Trauma Surg. 2020;140(6):843\u201352.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"5","key":"4984_CR10","doi-asserted-by":"publisher","first-page":"665","DOI":"10.1007\/s00402-020-03372-z","volume":"140","author":"R Rosenauer","year":"2020","unstructured":"Rosenauer R, Pezzei C, Quadlbauer S, Keuchel T, Jurkowitsch J, Hausner T, et al. Complications after operatively treated distal radius fractures. Arch Orthop Trauma Surg. 2020;140(5):665\u201373.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"12","key":"4984_CR11","doi-asserted-by":"publisher","first-page":"1773","DOI":"10.1007\/s00402-018-3051-5","volume":"138","author":"S Quadlbauer","year":"2018","unstructured":"Quadlbauer S, Pezzei C, Jurkowitsch J, Rosenauer R, Pichler A, Sch\u00e4ttin S, et al. Early complications and radiological outcome after distal radius fractures stabilized by volar angular stable locking plate. Arch Orthop Trauma Surg. 2018;138(12):1773\u201382.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"4","key":"4984_CR12","doi-asserted-by":"publisher","first-page":"328","DOI":"10.2106\/JBJS.J.00193","volume":"93","author":"M Soong","year":"2011","unstructured":"Soong M, Earp BE, Bishop G, Leung A, Blazar P. Volar locking plate implant prominence and flexor tendon rupture. J Bone Joint Surg Am. 2011;93(4):328\u201335.","journal-title":"J Bone Joint Surg Am"},{"issue":"5","key":"4984_CR13","doi-asserted-by":"publisher","first-page":"692","DOI":"10.1177\/1558944718820956","volume":"15","author":"A Cook","year":"2020","unstructured":"Cook A, Baldwin P, Fowler JR. Incidence of flexor Pollicis longus complications following volar locking plate fixation of distal radius fractures. Hand (N Y). 2020;15(5):692\u20137.","journal-title":"Hand (N Y)"},{"issue":"10","key":"4984_CR14","doi-asserted-by":"publisher","first-page":"853","DOI":"10.1016\/j.jhsa.2019.04.012","volume":"44","author":"M Bergsma","year":"2019","unstructured":"Bergsma M, Brown K, Doornberg J, Sierevelt I, Jaarsma R, Jadav B. Distal radius volar plate design and volar prominence to the watershed line in clinical practice: comparison of Soong grading of 2 common plates in 400 patients. J Hand Surg Am. 2019;44(10):853\u20139.","journal-title":"J Hand Surg Am."},{"issue":"6","key":"4984_CR15","doi-asserted-by":"publisher","first-page":"1091","DOI":"10.1016\/j.jhsa.2013.03.011","volume":"38","author":"A Kitay","year":"2013","unstructured":"Kitay A, Swanstrom M, Schreiber JJ, Carlson MG, Nguyen JT, Weiland AJ, et al. Volar plate position and flexor tendon rupture following distal radius fracture fixation. J Hand Surg Am. 2013;38(6):1091\u20136.","journal-title":"J Hand Surg Am."},{"issue":"1","key":"4984_CR16","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1016\/j.ocl.2015.08.020","volume":"47","author":"MM Vosbikian","year":"2016","unstructured":"Vosbikian MM, Ketonis C, Huang R, Ilyas AM. Optimal positioning for volar plate fixation of a distal radius fracture: determining the distal dorsal cortical distance. Orthop Clin North Am. 2016;47(1):235\u201344.","journal-title":"Orthop Clin North Am"},{"issue":"3","key":"4984_CR17","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1055\/s-0040-1702931","volume":"9","author":"K Yamak","year":"2020","unstructured":"Yamak K, Karahan HG, Karatan B, Kayal\u0131 C, Altay T. Evaluation of flexor Pollicis longus tendon rupture after treatment of distal radius fracture with the volar plate. J Wrist Surg. 2020;9(3):219\u201324.","journal-title":"J Wrist Surg"},{"issue":"1","key":"4984_CR18","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1055\/s-0037-1601325","volume":"9","author":"M Spiteri","year":"2017","unstructured":"Spiteri M, Ng W, Matthews J, Power D. Functional outcome of fixation of complex intra-articular distal radius fractures with a variable-angle distal radius volar rim plate. J Hand Microsurg. 2017;9(1):11\u20136.","journal-title":"J Hand Microsurg"},{"issue":"2","key":"4984_CR19","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1007\/s00402-018-3081-z","volume":"139","author":"L Schlickum","year":"2019","unstructured":"Schlickum L, Quadlbauer S, Pezzei C, St\u00f6phasius E, Hausner T, Leixnering M. Three-dimensional kinematics of the flexor pollicis longus tendon in relation to the position of the FPL plate and distal radius width. Arch Orthop Trauma Surg. 2019;139(2):269\u201379.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"8","key":"4984_CR20","doi-asserted-by":"publisher","first-page":"1297","DOI":"10.1007\/s00402-020-03565-6","volume":"141","author":"V Palola","year":"2021","unstructured":"Palola V, Ponkilainen V, Huttunen T, Launonen A, Mattila VM. Incidence for volar locking plate removal following distal radius fracture surgery. Arch Orthop Trauma Surg. 2021;141(8):1297\u2013302.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"1","key":"4984_CR21","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1186\/s12891-018-2052-4","volume":"19","author":"VD Varghese","year":"2018","unstructured":"Varghese VD, Smitham P, Howell S, Edwards S, Rickman M. POWIFF-Prospective study of wrist internal fixation of fracture: a protocol for a single Centre, superiority, randomised controlled trial to study the efficacy of the VRP (2.0) distal radius plate (Austofix) versus the VA-LCP (Depuy-Synthes) for distal radius fractures. BMC Musculoskelet Disord. 2018;19(1):131.","journal-title":"BMC Musculoskelet Disord"},{"issue":"6","key":"4984_CR22","doi-asserted-by":"publisher","first-page":"1249","DOI":"10.1016\/j.injury.2017.03.035","volume":"48","author":"M Guzzini","year":"2017","unstructured":"Guzzini M, Lanzetti RM, Lupariello D, Morelli F, Princi G, Perugia D, et al. Comparison between carbon-peek plate and conventional stainless steal plate in ankle fractures. A prospective study of two years follow up. Injury. 2017;48(6):1249\u201352.","journal-title":"Injury."},{"issue":"3","key":"4984_CR23","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.jhsa.2016.12.001","volume":"42","author":"M Landgren","year":"2017","unstructured":"Landgren M, Abramo A, Geijer M, Kopylov P, T\u00e4gil M. Fragment-specific fixation versus volar locking plates in primarily nonreducible or secondarily Redisplaced distal radius fractures: a randomized controlled study. J Hand Surg Am. 2017;42(3):156\u201365.e1.","journal-title":"J Hand Surg Am."},{"issue":"3","key":"4984_CR24","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1016\/j.hcl.2005.02.003","volume":"21","author":"J Orbay","year":"2005","unstructured":"Orbay J. Volar plate fixation of distal radius fractures. Hand Clin. 2005;21(3):347\u201354.","journal-title":"Hand Clin"},{"key":"4984_CR25","unstructured":"David L. Nelson JO, Randy Bindra. Anatomy of the Volar Distal Radius 2008."},{"issue":"3","key":"4984_CR26","doi-asserted-by":"publisher","first-page":"268","DOI":"10.1055\/s-0039-1694719","volume":"9","author":"M Bergsma","year":"2020","unstructured":"Bergsma M, Doornberg JN, Hendrickx L, Hayat B, Kerkhoffs G, Jhadav B, et al. Interpretations of the term \"watershed line\" used as reference for volar plating. J Wrist Surg. 2020;9(3):268\u201374.","journal-title":"J Wrist Surg."},{"issue":"1","key":"4984_CR27","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s00264-002-0393-x","volume":"27","author":"H Drobetz","year":"2003","unstructured":"Drobetz H, Kutscha-Lissberg E. Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop. 2003;27(1):1\u20136.","journal-title":"Int Orthop"},{"issue":"4","key":"4984_CR28","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1177\/1753193408100964","volume":"34","author":"JA Casaletto","year":"2009","unstructured":"Casaletto JA, Machin D, Leung R, Brown DJ. Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius. J Hand Surg Eur. 2009;34(4):471\u20134.","journal-title":"J Hand Surg Eur"},{"issue":"10","key":"4984_CR29","doi-asserted-by":"publisher","first-page":"2035","DOI":"10.1016\/j.jhsa.2012.06.041","volume":"37","author":"BD White","year":"2012","unstructured":"White BD, Nydick JA, Karsky D, Williams BD, Hess AV, Stone JD. Incidence and clinical outcomes of tendon rupture following distal radius fracture. J Hand Surg Am. 2012;37(10):2035\u201340.","journal-title":"J Hand Surg Am."},{"key":"4984_CR30","unstructured":"DePuy Synthes LCP Distal Radius System 2.4. Surgical Technique [Available from: http:\/\/synthes.vo.llnwd.net\/o16\/LLNWMB8\/US%20Mobile\/Synthes%20North%20America\/Product%20Support%20Materials\/Technique%20Guides\/DSUSTRM09161037_2-4mmLCP_DistRad_TG_150dpi.pdf."},{"key":"4984_CR31","unstructured":"Acumed Acu-Loc Wrist Plating System Surgical Technique [Available from: https:\/\/www.acumed.net\/wp-content\/uploads\/2017\/12\/Acumed-Surgical-Technique-EN-Acu-Loc-Wrist-Plating-System-HNW00-01-E.pdf."},{"issue":"7","key":"4984_CR32","doi-asserted-by":"publisher","first-page":"1144","DOI":"10.1016\/j.jhsa.2008.02.029","volume":"33","author":"JE Buzzell","year":"2008","unstructured":"Buzzell JE, Weikert DR, Watson JT, Lee DH. Precontoured fixed-angle volar distal radius plates: a comparison of anatomic fit. J Hand Surg Am. 2008;33(7):1144\u201352.","journal-title":"J Hand Surg Am."},{"issue":"4","key":"4984_CR33","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1007\/s10195-013-0245-z","volume":"14","author":"S Asadollahi","year":"2013","unstructured":"Asadollahi S, Keith PP. Flexor tendon injuries following plate fixation of distal radius fractures: a systematic review of the literature. J Orthop Traumatol. 2013;14(4):227\u201334.","journal-title":"J Orthop Traumatol"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-021-04984-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-021-04984-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-021-04984-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,1,3]],"date-time":"2022-01-03T17:03:57Z","timestamp":1641229437000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-021-04984-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,3]]},"references-count":33,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["4984"],"URL":"https:\/\/doi.org\/10.1186\/s12891-021-04984-1","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,3]]},"assertion":[{"value":"18 May 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 December 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 January 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This was a retrospective study and The Institutional Review Board of Kaohsiung Veterans General Hospital approved this study.This study was conducted in accordance with the Declaration of Helsinki. Informed consent was obtained from all individual participants included in the study for all surgical procedures and for the possible use of anonymized photographs.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not Applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no conflict of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"18"}}