{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T23:49:50Z","timestamp":1785800990291,"version":"3.56.0"},"reference-count":55,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,1,5]],"date-time":"2022-01-05T00:00:00Z","timestamp":1641340800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,1,5]],"date-time":"2022-01-05T00:00:00Z","timestamp":1641340800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Complex intraarticular distal radius fractures (DRFs), commonly managed with volar locking plates, are challenging. Combined volar and dorsal plating is frequently applied for treatment, however, biomechanical investigations are scant. The aim of this biomechanical study was to investigate volar plating versus double plating in DRFs with different degrees of lunate facet comminution.<\/jats:p><jats:p>Thirty artificial radii with simulated\u00a0AO\/OTA 23-C2.1 and C3.1 DRFs, including dorsal defect and lunate facet comminution, were assigned to 3 groups: Group 1 with two equally-sized lunate facet fragments; Group 2 with small dorsal and large volar fragment; Group 3 with three equally-sized fragments. The specimens underwent volar and double locked plating and non-destructive ramped loading in 0\u00b0 neutral position, 40\u00b0 flexion and 40\u00b0 extension.<\/jats:p><jats:p>In each tested position, stiffness: (1) did not significantly differ among groups with same fixation method (<jats:italic>p<\/jats:italic>\u2009\u2265\u20090.15); (2) increased significantly after supplemental dorsal plating in Group 2 and Group 3 (<jats:italic>p<\/jats:italic>\u2009\u2264\u20090.02).<\/jats:p><jats:p>Interfragmentary displacements between styloid process and lunate facet in neutral position were below 0.5\u2009mm, being not significantly different among groups and plating techniques (<jats:italic>p<\/jats:italic>\u2009\u2265\u20090.63).<\/jats:p><jats:p>Following volar plating, angular displacement of the lunate facet to radius shaft was significantly lower in Group 1 versus both Group 2 and Group 3 (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.01). It decreased significantly after supplemental dorsal plating in Group 2 and Group 3 (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.01), but not in Group 1 (<jats:italic>p<\/jats:italic>\u2009\u2265\u20090.13), and did not differ significantly among the three groups after double plating (<jats:italic>p<\/jats:italic>\u2009\u2265\u20090.74).<\/jats:p><jats:p>Comminution of the lunate facet within its dorsal third significantly affected the biomechanical outcomes related to complex intraarticular DRFs treated with volar and double locked plates.<\/jats:p><jats:p>Double plating demonstrates superior stability versus volar plating only for lunate facet comminution within its dorsal third. In contrast, volar plating could achieve stability comparable with double plating when the dorsal third of the lunate facet is not separated by the fracture pattern. Both fixation methods indicated achievable absolute stability between the articular fragments.<\/jats:p>","DOI":"10.1186\/s12891-021-04989-w","type":"journal-article","created":{"date-parts":[[2022,1,5]],"date-time":"2022-01-05T21:22:33Z","timestamp":1641417753000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Volar versus combined dorsal and volar plate fixation of complex intraarticular distal radius fractures with small dorsoulnar fragment \u2013 a biomechanical study"],"prefix":"10.1186","volume":"23","author":[{"given":"Mariya","family":"Hadzhinikolova","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ivan","family":"Zderic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Ciric","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan P.","family":"Barcik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dian","family":"Enchev","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Asen","family":"Baltov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lyubomir","family":"Rusimov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Varga","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karl","family":"Stoffel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Geoff","family":"Richards","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Boyko","family":"Gueorguiev","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mihail","family":"Rashkov","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,1,5]]},"reference":[{"issue":"1","key":"4989_CR1","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1142\/S0218810414970016","volume":"19","author":"K Ikeda","year":"2014","unstructured":"Ikeda K, Osamura N, Tada K. Fixation of an ulnodorsal fragment when treating an intra-articular fracture in the distal radius. Hand Surg. 2014;19(1):139\u201344.","journal-title":"Hand Surg"},{"issue":"11","key":"4989_CR2","doi-asserted-by":"publisher","first-page":"2004","DOI":"10.1016\/j.injury.2019.08.003","volume":"50","author":"Y Miyashima","year":"2019","unstructured":"Miyashima Y, Kaneshiro Y, Yano K, Teraura H, Sakanaka H, Uemura T. Size and stabilization of the dorsoulnar fragment in AO C3-type distal radius fractures. Injury. 2019;50(11):2004\u20138.","journal-title":"Injury"},{"issue":"2","key":"4989_CR3","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1055\/s-0038-1673407","volume":"8","author":"J Lans","year":"2019","unstructured":"Lans J, Alvarez J, Kachooei AR, Ozkan S, Jupiter JB. Dorsal lunate facet fracture reduction using a bone reduction forceps. J Wrist Surg. 2019;8(2):118\u201323.","journal-title":"J Wrist Surg"},{"issue":"2","key":"4989_CR4","doi-asserted-by":"publisher","first-page":"230","DOI":"10.1007\/s11552-013-9585-7","volume":"9","author":"AM Moore","year":"2014","unstructured":"Moore AM, Dennison DG. Distal radius fractures and the volar lunate facet fragment: Kirschner wire fixation in addition to volar-locked plating. Hand (N Y). 2014;9(2):230\u20136.","journal-title":"Hand (N Y)"},{"key":"4989_CR5","first-page":"6269081","volume":"2017","author":"H Obata","year":"2017","unstructured":"Obata H, Baba T, Futamura K, Obayashi O, Mogami A, Tsuji H, et al. Difficulty in fixation of the volar lunate facet fragment in distal radius fracture. Case Rep Orthop. 2017;2017:6269081.","journal-title":"Case Rep Orthop"},{"issue":"02","key":"4989_CR6","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1055\/s-0036-1579549","volume":"5","author":"MA O'Shaughnessy","year":"2016","unstructured":"O'Shaughnessy MA, Shin AY, Kakar S. Stabilization of volar ulnar rim fractures of the distal radius: current techniques and review of the literature. J Wrist Surg. 2016;5(02):113\u20139.","journal-title":"J Wrist Surg"},{"issue":"9","key":"4989_CR7","doi-asserted-by":"publisher","first-page":"1315","DOI":"10.1007\/s00402-015-2290-y","volume":"135","author":"JI Lee","year":"2015","unstructured":"Lee JI, Cho JH, Lee SJ. The effects of the frag-Loc((R)) compression screw on distal radius fracture with a displaced dorsoulnar fragment. Arch Orthop Trauma Surg. 2015;135(9):1315\u201321.","journal-title":"Arch Orthop Trauma Surg"},{"key":"4989_CR8","unstructured":"Slutsky DJ, Osterman AL. Fractures and injuries of the distal radius and carpus: the cutting edge. Elsevier Health Sci. 2009. p. 125\u201333. https:\/\/www.sciencedirect.com\/science\/article\/pii\/B9781416040835000135?via%3Dihub."},{"issue":"3","key":"4989_CR9","doi-asserted-by":"publisher","first-page":"528","DOI":"10.1016\/j.injury.2013.10.003","volume":"45","author":"NA Johnson","year":"2014","unstructured":"Johnson NA, Cutler L, Dias JJ, Ullah AS, Wildin CJ, Bhowal B. Complications after volar locking plate fixation of distal radius fractures. Injury. 2014;45(3):528\u201333.","journal-title":"Injury"},{"issue":"Suppl 1(Pt 2)","key":"4989_CR10","first-page":"195","volume":"87","author":"D Ring","year":"2005","unstructured":"Ring D, Prommersberger K, Jupiter JB. Combined dorsal and volar plate fixation of complex fractures of the distal part of the radius. J Bone Joint Surg Am. 2005;87(Suppl 1(Pt 2)):195\u2013212.","journal-title":"J Bone Joint Surg Am"},{"issue":"7","key":"4989_CR11","first-page":"505","volume":"120","author":"M Kilian","year":"2019","unstructured":"Kilian M, Simkovic P, Zamborsky R, Skoda A, Labas P. What are the ideal screw lengths in volar locking plate fixation for distal radius fractures? Bratisl Lek Listy. 2019;120(7):505\u20139.","journal-title":"Bratisl Lek Listy"},{"issue":"4","key":"4989_CR12","doi-asserted-by":"publisher","first-page":"743","DOI":"10.1016\/j.jhsa.2005.03.006","volume":"30","author":"DS Musgrave","year":"2005","unstructured":"Musgrave DS, Idler RS. Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates. J Hand Surg Am. 2005;30(4):743\u20139.","journal-title":"J Hand Surg Am"},{"issue":"2","key":"4989_CR13","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1007\/s11552-010-9316-2","volume":"6","author":"K Ozer","year":"2011","unstructured":"Ozer K, Toker S. Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating. Hand (N Y). 2011;6(2):190\u20133.","journal-title":"Hand (N Y)"},{"issue":"11","key":"4989_CR14","doi-asserted-by":"publisher","first-page":"1248","DOI":"10.1016\/j.injury.2010.12.005","volume":"42","author":"S Rausch","year":"2011","unstructured":"Rausch S, Klos K, Stephan H, Hoffmeier K, Gras F, Windolf M, et al. Evaluation of a polyaxial angle-stable volar plate in a distal radius C-fracture model--a biomechanical study. Injury. 2011;42(11):1248\u201352.","journal-title":"Injury"},{"issue":"2","key":"4989_CR15","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1016\/j.injury.2009.09.025","volume":"41","author":"M Windolf","year":"2010","unstructured":"Windolf M, Schwieger K, Ockert B, Jupiter JB, Gradl G. A novel non-bridging external fixator construct versus volar angular stable plating for the fixation of intra-articular fractures of the distal radius--a biomechanical study. Injury. 2010;41(2):204\u20139.","journal-title":"Injury"},{"issue":"4","key":"4989_CR16","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1002\/jor.1100060406","volume":"6","author":"AF Tencer","year":"1988","unstructured":"Tencer AF, Viegas SF, Cantrell J, Chang M, Clegg P, Hicks C, et al. Pressure distribution in the wrist joint. J Orthop Res. 1988;6(4):509\u201317.","journal-title":"J Orthop Res"},{"issue":"2","key":"4989_CR17","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1016\/S0363-5023(87)80270-8","volume":"12","author":"T Trumble","year":"1987","unstructured":"Trumble T, Glisson RR, Seaber AV, Urbaniak JR. Forearm force transmission after surgical treatment of distal radioulnar joint disorders. J Hand Surg Am. 1987;12(2):196\u2013202.","journal-title":"J Hand Surg Am"},{"issue":"3","key":"4989_CR18","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1016\/S0363-5023(89)80004-8","volume":"14","author":"SF Viegas","year":"1989","unstructured":"Viegas SF, Patterson R, Peterson P, Roefs J, Tencer A, Choi S. The effects of various load paths and different loads on the load transfer characteristics of the wrist. J Hand Surg Am. 1989;14(3):458\u201365.","journal-title":"J Hand Surg Am"},{"issue":"5","key":"4989_CR19","doi-asserted-by":"publisher","first-page":"728","DOI":"10.1016\/0363-5023(90)90144-G","volume":"15","author":"SF Viegas","year":"1990","unstructured":"Viegas SF, Pogue DJ, Patterson RM, Peterson PD. Effects of radioulnar instability on the radiocarpal joint: a biomechanical study. J Hand Surg Am. 1990;15(5):728\u201332.","journal-title":"J Hand Surg Am"},{"issue":"10","key":"4989_CR20","doi-asserted-by":"publisher","first-page":"1587","DOI":"10.1016\/j.jhsa.2006.09.011","volume":"31","author":"M Blythe","year":"2006","unstructured":"Blythe M, Stoffel K, Jarrett P, Kuster M. Volar versus dorsal locking plates with and without radial styloid locking plates for the fixation of dorsally comminuted distal radius fractures: a biomechanical study in cadavers. J Hand Surg Am. 2006;31(10):1587\u201393.","journal-title":"J Hand Surg Am"},{"issue":"9","key":"4989_CR21","doi-asserted-by":"publisher","first-page":"605","DOI":"10.1097\/BOT.0b013e318186006f","volume":"22","author":"U Kandemir","year":"2008","unstructured":"Kandemir U, Matityahu A, Desai R, Puttlitz C. Does a volar locking plate provide equivalent stability as a dorsal nonlocking plate in a dorsally comminuted distal radius fracture?: a biomechanical study. J Orthop Trauma. 2008;22(9):605\u201310.","journal-title":"J Orthop Trauma"},{"issue":"1","key":"4989_CR22","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1053\/jhsu.2003.50016","volume":"28","author":"D Osada","year":"2003","unstructured":"Osada D, Viegas SF, Shah MA, Morris RP, Patterson RM. Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study. J Hand Surg Am. 2003;28(1):94\u2013104.","journal-title":"J Hand Surg Am"},{"issue":"1","key":"4989_CR23","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1053\/jhsu.2000.jhsu025a0029","volume":"25","author":"R Peine","year":"2000","unstructured":"Peine R, Rikli DA, Hoffmann R, Duda G, Regazzoni P. Comparison of three different plating techniques for the dorsum of the distal radius: a biomechanical study. J Hand Surg Am. 2000;25(1):29\u201333.","journal-title":"J Hand Surg Am"},{"issue":"4","key":"4989_CR24","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1016\/j.injury.2012.08.048","volume":"44","author":"S Rausch","year":"2013","unstructured":"Rausch S, Schlonski O, Klos K, Gras F, Gueorguiev B, Hofmann GO, et al. Volar versus dorsal latest-generation variable-angle locking plates for the fixation of AO type 23C 2.1 distal radius fractures: a biomechanical study in cadavers. Injury. 2013;44(4):523\u20136.","journal-title":"Injury"},{"issue":"6","key":"4989_CR25","doi-asserted-by":"publisher","first-page":"974","DOI":"10.1016\/j.jhsa.2011.02.024","volume":"36","author":"YC Chou","year":"2011","unstructured":"Chou YC, Chen AC, Chen CY, Hsu YH, Wu CC. Dorsal and volar 2.4-mm titanium locking plate fixation for AO type C3 dorsally comminuted distal radius fractures. J Hand Surg Am. 2011;36(6):974\u201381.","journal-title":"J Hand Surg Am"},{"issue":"4","key":"4989_CR26","doi-asserted-by":"publisher","first-page":"535","DOI":"10.1016\/j.injury.2012.10.012","volume":"44","author":"H Drobetz","year":"2013","unstructured":"Drobetz H, Weninger P, Grant C, Heal C, Muller R, Schuetz M, et al. More is not necessarily better. A biomechanical study on distal screw numbers in volar locking distal radius plates. Injury. 2013;44(4):535\u20139.","journal-title":"Injury"},{"issue":"3","key":"4989_CR27","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1097\/01.bth.0000173374.97406.70","volume":"9","author":"JL Orbay","year":"2005","unstructured":"Orbay JL, Touhami A, Orbay C. Fixed angle fixation of distal radius fractures through a minimally invasive approach. Tech Hand Up Extrem Surg. 2005;9(3):142\u20138.","journal-title":"Tech Hand Up Extrem Surg"},{"issue":"12","key":"4989_CR28","doi-asserted-by":"publisher","first-page":"e491","DOI":"10.1016\/j.jhsa.2016.09.007","volume":"41","author":"D Tordjman","year":"2016","unstructured":"Tordjman D, Hinds RM, Ayalon O, Yang SS, Capo JT. Volar-ulnar approach for fixation of the volar lunate facet fragment in distal radius fractures: a technical tip. J Hand Surg Am. 2016;41(12):e491\u2013500.","journal-title":"J Hand Surg Am"},{"issue":"2","key":"4989_CR29","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1016\/j.jhsa.2007.10.018","volume":"33","author":"M Majima","year":"2008","unstructured":"Majima M, Horii E, Matsuki H, Hirata H, Genda E. Load transmission through the wrist in the extended position. J Hand Surg Am. 2008;33(2):182\u20138.","journal-title":"J Hand Surg Am"},{"issue":"1","key":"4989_CR30","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/j.jhsa.2006.10.007","volume":"32","author":"DA Rikli","year":"2007","unstructured":"Rikli DA, Honigmann P, Babst R, Cristalli A, Morlock MM, Mittlmeier T. Intra-articular pressure measurement in the radioulnocarpal joint using a novel sensor: in vitro and in vivo results. J Hand Surg Am. 2007;32(1):67\u201375.","journal-title":"J Hand Surg Am"},{"issue":"2","key":"4989_CR31","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1016\/j.medengphy.2015.11.006","volume":"38","author":"P Varga","year":"2016","unstructured":"Varga P, Zysset PK, Schefzig P, Unger E, Mayr W, Erhart J. A finite element analysis of two novel screw designs for scaphoid waist fractures. Med Eng Phys. 2016;38(2):131\u20139.","journal-title":"Med Eng Phys"},{"issue":"8","key":"4989_CR32","doi-asserted-by":"publisher","first-page":"1646","DOI":"10.2106\/00004623-200408000-00007","volume":"86-a","author":"D Ring","year":"2004","unstructured":"Ring D, Prommersberger K, Jupiter JB. Combined dorsal and volar plate fixation of complex fractures of the distal part of the radius. J Bone Joint Surg Am. 2004;86-a(8):1646\u201352.","journal-title":"J Bone Joint Surg Am"},{"issue":"3","key":"4989_CR33","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1055\/s-0038-1676859","volume":"8","author":"M Sagerfors","year":"2019","unstructured":"Sagerfors M, Bjorling P, Niklasson J, Pettersson K. Combined volar T-plate and dorsal pi-plate for distal radius fractures: a consecutive series of 80 AO type C2 and C3 cases. J Wrist Surg. 2019;8(3):180\u20135.","journal-title":"J Wrist Surg"},{"issue":"3","key":"4989_CR34","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1302\/0301-620X.82B3.0820340","volume":"82","author":"M Jakob","year":"2000","unstructured":"Jakob M, Rikli DA, Regazzoni P. Fractures of the distal radius treated by internal fixation and early function. A prospective study of 73 consecutive patients. J Bone Joint Surg Br. 2000;82(3):340\u20134.","journal-title":"J Bone Joint Surg Br"},{"issue":"7","key":"4989_CR35","doi-asserted-by":"publisher","first-page":"1061","DOI":"10.1016\/j.jhsa.2006.05.008","volume":"31","author":"AF Kamath","year":"2006","unstructured":"Kamath AF, Zurakowski D, Day CS. Low-profile dorsal plating for dorsally angulated distal radius fractures: an outcomes study. J Hand Surg Am. 2006;31(7):1061\u20137.","journal-title":"J Hand Surg Am"},{"issue":"4","key":"4989_CR36","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1016\/S0363-5023(98)80063-4","volume":"23","author":"GK Kambouroglou","year":"1998","unstructured":"Kambouroglou GK, Axelrod TS. Complications of the AO\/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: a brief report. J Hand Surg Am. 1998;23(4):737\u201341.","journal-title":"J Hand Surg Am"},{"issue":"7","key":"4989_CR37","doi-asserted-by":"publisher","first-page":"963","DOI":"10.1302\/0301-620X.96B7.33149","volume":"96-B","author":"C Mellstrand-Navarro","year":"2014","unstructured":"Mellstrand-Navarro C, Pettersson HJ, Tornqvist H, Ponzer S. The operative treatment of fractures of the distal radius is increasing: results from a nationwide Swedish study. Bone Joint J. 2014;96-B(7):963\u20139.","journal-title":"Bone Joint J"},{"issue":"3","key":"4989_CR38","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1016\/j.hcl.2005.02.003","volume":"21","author":"J Orbay","year":"2005","unstructured":"Orbay J. Volar plate fixation of distal radius fractures. Hand Clin. 2005;21(3):347\u201354.","journal-title":"Hand Clin"},{"issue":"2","key":"4989_CR39","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1142\/S0218810400000223","volume":"5","author":"JL Orbay","year":"2000","unstructured":"Orbay JL. The treatment of unstable distal radius fractures with volar fixation. Hand Surg. 2000;5(2):103\u201312.","journal-title":"Hand Surg"},{"issue":"2","key":"4989_CR40","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1053\/jhsu.2002.32081","volume":"27","author":"JL Orbay","year":"2002","unstructured":"Orbay JL, Fernandez DL. Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am. 2002;27(2):205\u201315.","journal-title":"J Hand Surg Am"},{"issue":"1","key":"4989_CR41","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1016\/j.jhsa.2005.09.011","volume":"31","author":"DS Ruch","year":"2006","unstructured":"Ruch DS, Papadonikolakis A. Volar versus dorsal plating in the management of intra-articular distal radius fractures. J Hand Surg Am. 2006;31(1):9\u201316.","journal-title":"J Hand Surg Am"},{"issue":"3","key":"4989_CR42","doi-asserted-by":"publisher","first-page":"382","DOI":"10.1016\/j.jhsa.2005.10.016","volume":"31","author":"PM Simic","year":"2006","unstructured":"Simic PM, Robison J, Gardner MJ, Gelberman RH, Weiland AJ, Boyer MI. Treatment of distal radius fractures with a low-profile dorsal plating system: an outcomes assessment. J Hand Surg Am. 2006;31(3):382\u20136.","journal-title":"J Hand Surg Am"},{"issue":"4","key":"4989_CR43","doi-asserted-by":"publisher","first-page":"756","DOI":"10.1016\/j.jhsa.2005.04.017","volume":"30","author":"C Trease","year":"2005","unstructured":"Trease C, McIff T, Toby EB. Locking versus nonlocking T-plates for dorsal and volar fixation of dorsally comminuted distal radius fractures: a biomechanical study. J Hand Surg Am. 2005;30(4):756\u201363.","journal-title":"J Hand Surg Am"},{"issue":"4","key":"4989_CR44","doi-asserted-by":"publisher","first-page":"588","DOI":"10.1302\/0301-620X.78B4.0780588","volume":"78","author":"DA Rikli","year":"1996","unstructured":"Rikli DA, Regazzoni P. Fractures of the distal end of the radius treated by internal fixation and early function. A preliminary report of 20 cases. J Bone Joint Surg Br. 1996;78(4):588\u201392.","journal-title":"J Bone Joint Surg Br"},{"issue":"4","key":"4989_CR45","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1016\/J.JHSO.2007.03.014","volume":"32","author":"AJ Hart","year":"2007","unstructured":"Hart AJ, Seepaul T, Hewitt RJ, Ang S, Hansen U, Amis AA. The palmar locking compression plate is biomechanically comparable to the dorsal pi plate for dorsally comminuted, intraarticular wrist fractures. J Hand Surg Eur. 2007;32(4):388\u201393.","journal-title":"J Hand Surg Eur"},{"issue":"6","key":"4989_CR46","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1016\/j.jhsa.2007.03.015","volume":"32","author":"J Knox","year":"2007","unstructured":"Knox J, Ambrose H, McCallister W, Trumble T. Percutaneous pins versus volar plates for unstable distal radius fractures: a biomechanic study using a cadaver model. J Hand Surg Am. 2007;32(6):813\u20137.","journal-title":"J Hand Surg Am"},{"issue":"3","key":"4989_CR47","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1097\/00005131-200503000-00006","volume":"19","author":"FA Liporace","year":"2005","unstructured":"Liporace FA, Gupta S, Jeong GK, Stracher M, Kummer F, Egol KA, et al. A biomechanical comparison of a dorsal 3.5-mm T-plate and a volar fixed-angle plate in a model of dorsally unstable distal radius fractures. J Orthop Trauma. 2005;19(3):187\u201391.","journal-title":"J Orthop Trauma"},{"issue":"11","key":"4989_CR48","doi-asserted-by":"publisher","first-page":"2411","DOI":"10.2106\/00004623-200611000-00013","volume":"88","author":"AA Willis","year":"2006","unstructured":"Willis AA, Kutsumi K, Zobitz ME, Cooney WP. 3rd: internal fixation of dorsally displaced fractures of the distal part of the radius. A biomechanical analysis of volar plate fracture stability. J Bone Joint Surg Am. 2006;88(11):2411\u20137.","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"4989_CR49","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1016\/S0749-0712(21)00083-4","volume":"13","author":"WH Short","year":"1997","unstructured":"Short WH, Werner FW, Fortino MD, Mann KA. Analysis of the kinematics of the scaphoid and lunate in the intact wrist joint. Hand Clin. 1997;13(1):93\u2013108.","journal-title":"Hand Clin"},{"issue":"6","key":"4989_CR50","doi-asserted-by":"publisher","first-page":"986","DOI":"10.1016\/S0363-5023(05)80147-9","volume":"20","author":"WH Short","year":"1995","unstructured":"Short WH, Werner FW, Fortino MD, Palmer AK, Mann KA. A dynamic biomechanical study of scapholunate ligament sectioning. J Hand Surg Am. 1995;20(6):986\u201399.","journal-title":"J Hand Surg Am"},{"issue":"1","key":"4989_CR51","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1055\/s-0035-1570739","volume":"5","author":"NG Harness","year":"2016","unstructured":"Harness NG. Fixation options for the volar lunate facet fracture: thinking outside the box. J Wrist Surg. 2016;5(1):9\u201316.","journal-title":"J Wrist Surg"},{"key":"4989_CR52","first-page":"27","volume":"63","author":"CJ Dy","year":"2014","unstructured":"Dy CJ, Wolfe SW, Jupiter JB, Blazar PE, Ruch DS, Hanel DP. Distal radius fractures: strategic alternatives to volar plate fixation. Instr Course Lect. 2014;63:27\u201337.","journal-title":"Instr Course Lect"},{"issue":"1","key":"4989_CR53","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1055\/s-0035-1571184","volume":"5","author":"JK Kim","year":"2016","unstructured":"Kim JK, Yun YH, Kim DJ. The effect of displaced dorsal rim fragment in a distal radius fracture. J Wrist Surg. 2016;5(1):31\u20135.","journal-title":"J Wrist Surg"},{"issue":"4","key":"4989_CR54","doi-asserted-by":"publisher","first-page":"554","DOI":"10.1016\/S0363-5023(96)80003-7","volume":"21","author":"WF Wagner Jr","year":"1996","unstructured":"Wagner WF Jr, Tencer AF, Kiser P, Trumble TE. Effects of intra-articular distal radius depression on wrist joint contact characteristics. J Hand Surg Am. 1996;21(4):554\u201360.","journal-title":"J Hand Surg Am"},{"issue":"5","key":"4989_CR55","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1097\/00005131-199607000-00007","volume":"10","author":"DD Anderson","year":"1996","unstructured":"Anderson DD, Bell AL, Gaffney MB, Imbriglia JE. Contact stress distributions in malreduced intraarticular distal radius fractures. J Orthop Trauma. 1996;10(5):331\u20137.","journal-title":"J Orthop Trauma"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-021-04989-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-021-04989-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-021-04989-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,4,18]],"date-time":"2022-04-18T14:14:16Z","timestamp":1650291256000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-021-04989-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,5]]},"references-count":55,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["4989"],"URL":"https:\/\/doi.org\/10.1186\/s12891-021-04989-w","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,5]]},"assertion":[{"value":"21 August 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 December 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 January 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no affiliations with or involvement in any organization or entity with any financial interest (such as honoraria; educational grants; participation in speakers\u2019 bureaus; membership, employment, consultancies, stock ownership, or other equity interest; and expert testimony or patent-licensing arrangements), or non-financial interest (such as personal or professional relationships, affiliations, knowledge or beliefs) in the subject matter or materials discussed in this manuscript","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"35"}}