{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T13:19:37Z","timestamp":1794057577782,"version":"4.8.0"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,1,27]],"date-time":"2022-01-27T00:00:00Z","timestamp":1643241600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,1,27]],"date-time":"2022-01-27T00:00:00Z","timestamp":1643241600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>A complication associated with the distal locking screw used in the proximal femoral nail (PFN) system is the formation of accidental additional holes. We hypothesized that an increase in stress around additional holes is a relevant factor contributing to fractures. This study aimed to evaluate stress changes in the cortical bone around additional screw holes using finite element analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Proximal femoral nail antirotation (PFNA)-II (Synthes, Solothurn, Switzerland) was inserted into a femur model. An additional 4.9-mm transcortical hole was made either anteriorly (anterior hole model) or posteriorly (posterior hole model) to the distal locking screw. Finite element analysis was used to calculate compression, tension, and load limits to investigate stress around additional holes with respect to the direction of screw penetration and degree of osteoporosis. The results were then compared with those of mechanical testing. A 31A-21 type intertrochanteric fracture was applied. As a control group, a model without additional holes (no-hole model) was developed. Repeated load-loading tests were performed on 10 model bones per model group.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Tensile stress was significantly greater in the no-hole model when additional screw holes were present, and the anterior hole showed a higher maximum stress value than the posterior hole, suggesting that the anterior hole was more susceptible to fracture. The change in tensile stress first appeared in the hole around the lateral cortical bone and proceeded to the medial side. Biomechanical testing showed that fractures around the distal locking screw occurred in 0 cases of the no-hole, 10 of the anterior hole, and 9 of the posterior hole models.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>During PFN surgery for intertrochanteric fracture, holes with distal locking screws fixed and removed at the anterior and posterior of the nail can be a risk factor for fractures in the surrounding area.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12891-022-05006-4","type":"journal-article","created":{"date-parts":[[2022,1,27]],"date-time":"2022-01-27T11:03:50Z","timestamp":1643281430000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["A finite element analysis and cyclic load experiment on an additional transcortical-type hole formed around the proximal femoral nail system\u2019s distal locking screw"],"prefix":"10.1186","volume":"23","author":[{"given":"Hong Man","family":"Cho","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seung Min","family":"Choi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ji Yeon","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Young","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jung Hyung","family":"Bae","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,1,27]]},"reference":[{"key":"5006_CR1","doi-asserted-by":"publisher","first-page":"1041","DOI":"10.1007\/s00264-009-0874-2","volume":"34","author":"J Sk\u00e1la-Rosenbaum","year":"2010","unstructured":"Sk\u00e1la-Rosenbaum J, Barton\u00edcek J, Barto\u0161ka R. Is distal locking with IMHN necessary in every pertrochanteric fracture? Int Orthop. 2010;34:1041\u20137.","journal-title":"Int Orthop"},{"key":"5006_CR2","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1007\/s00264-006-0170-3","volume":"31","author":"WM Gadegone","year":"2007","unstructured":"Gadegone WM, Salphale YS. Proximal femoral nail: an analysis of 100 cases of proximal femoral fractures with an average follow up of 1 year. Int Orthop. 2007;31:403\u20138.","journal-title":"Int Orthop"},{"key":"5006_CR3","doi-asserted-by":"publisher","first-page":"147","DOI":"10.5194\/ms-6-147-2015","volume":"6","author":"A Gok","year":"2015","unstructured":"Gok A, Gok K, Bilgin MB. Three-dimensional finite element model of the drilling process used for fixation of salter\u2013Harris type-3 fractures by using a K-wire. Mech Sci. 2015;6:147\u201354.","journal-title":"Mech Sci"},{"key":"5006_CR4","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1007\/s40430-019-1640-z","volume":"41","author":"K Gok","year":"2019","unstructured":"Gok K, Inal S, Urtekin L, Gok A. Biomechanical performance using finite element analysis of different screw materials in the parallel screw fixation of salter\u2013Harris type 4 fractures. J Braz Soc Mech Sci Eng. 2019;41:143.","journal-title":"J Braz Soc Mech Sci Eng"},{"key":"5006_CR5","doi-asserted-by":"publisher","unstructured":"G\u00f6k K, Sel\u00e7uk AB, G\u00f6k A. Computer-aided simulation using finite element analysis of protect against to coronavirus (COVID-19) of custom-made new mask design. Trans Indian Inst Metals. 2021. https:\/\/doi.org\/10.1007\/s12666-021-02227-4.","DOI":"10.1007\/s12666-021-02227-4"},{"key":"5006_CR6","doi-asserted-by":"publisher","unstructured":"Gok K. Investigation of the use of silicone pads to reduce the effects on the human face of classical face masks used to prevent from COVID-19 and other infections. Proc Inst Mech Eng E J Process Mech Eng. 2021. https:\/\/doi.org\/10.1177\/09544089211019581.","DOI":"10.1177\/09544089211019581"},{"key":"5006_CR7","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1186\/s13018-016-0377-y","volume":"11","author":"J Henschel","year":"2016","unstructured":"Henschel J, Eberle S, Augat P. Load distribution between cephalic screws in a dual lag screw trochanteric nail. J Orthop Surg Res. 2016;11:41.","journal-title":"J Orthop Surg Res"},{"key":"5006_CR8","doi-asserted-by":"publisher","first-page":"1193","DOI":"10.2106\/00004623-199308000-00009","volume":"75","author":"RW McCalden","year":"1993","unstructured":"McCalden RW, McGeough JA, Barker MB, Court-Brown CM. Age-related changes in the tensile properties of cortical bone. The relative importance of changes in porosity, mineralization, and microstructure. J Bone Joint Surg Am. 1993;75:1193\u2013205.","journal-title":"J Bone Joint Surg Am"},{"key":"5006_CR9","doi-asserted-by":"publisher","first-page":"421","DOI":"10.2106\/00004623-199703000-00016","volume":"79","author":"RW McCalden","year":"1997","unstructured":"McCalden RW, McGeough JA, Court-Brown CM. Age-related changes in the compressive strength of cancellous bone. The relative importance of changes in density and trabecular architecture. J Bone Joint Surg Am. 1997;79:421\u20137.","journal-title":"J Bone Joint Surg Am"},{"key":"5006_CR10","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1115\/1.2401178","volume":"129","author":"M Papini","year":"2007","unstructured":"Papini M, Zdero R, Schemitsch EH, Zalzal P. The biomechanics of human femurs in axial and torsional loading: comparison of finite element analysis, human cadaveric femurs, and synthetic femurs. J Biomech Eng. 2007;129:12\u20139.","journal-title":"J Biomech Eng"},{"key":"5006_CR11","doi-asserted-by":"publisher","first-page":"2128","DOI":"10.1177\/0300060518775835","volume":"46","author":"CH Lee","year":"2018","unstructured":"Lee CH, Su KC, Chen KH, Pan CC, Wu YC. Impact of tip-apex distance and femoral head lag screw position on treatment outcomes of unstable intertrochanteric fractures using cephalomedullary nails. J Int Med Res. 2018;46:2128\u201340.","journal-title":"J Int Med Res"},{"key":"5006_CR12","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1016\/S0021-9290(01)00040-9","volume":"34","author":"G Bergmann","year":"2001","unstructured":"Bergmann G, Deuretzbacher G, Heller M, Graichen F, Rohlmann A, Strauss J, et al. Hip contact forces and gait patterns from routine activities. J Biomech. 2001;34:859\u201371.","journal-title":"J Biomech"},{"key":"5006_CR13","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1016\/0141-5425(82)90009-7","volume":"4","author":"A Rohlmann","year":"1982","unstructured":"Rohlmann A, M\u00f6ssner U, Bergmann G, K\u00f6lbel R. Finite-element-analysis and experimental investigation of stresses in a femur. J Biomed Eng. 1982;4:241\u20136.","journal-title":"J Biomed Eng"},{"key":"5006_CR14","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1016\/j.clinbiomech.2003.12.003","volume":"19","author":"WP Chen","year":"2004","unstructured":"Chen WP, Tai CL, Shih CH, Hsieh PH, Leou MC, Lee MS. Selection of fixation devices in proximal femur rotational osteotomy: clinical complications and finite element analysis. Clin Biomech (Bristol, Avon). 2004;19:255\u201362.","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"5006_CR15","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1186\/s13018-019-1097-x","volume":"14","author":"J Li","year":"2019","unstructured":"Li J, Zhao Z, Yin P, Zhang L, Tang P. Comparison of three different internal fixation implants in treatment of femoral neck fracture a finite element analysis. J Orthop Surg Res. 2019;14:76.","journal-title":"J Orthop Surg Res"},{"key":"5006_CR16","doi-asserted-by":"publisher","first-page":"947","DOI":"10.1016\/j.asjsur.2019.01.008","volume":"42","author":"JT Kim","year":"2019","unstructured":"Kim JT, Jung CH, Shen QH, Cha YH, Park CH, Yoo JI, et al. Mechanical effect of different implant CCD angles on the fracture surface after fixation of an unstable intertrochanteric fracture: a finite element analysis. Asian J Surg. 2019;42:947\u201356.","journal-title":"Asian J Surg"},{"key":"5006_CR17","doi-asserted-by":"publisher","first-page":"e77807","DOI":"10.1371\/journal.pone.0077807","volume":"8","author":"V Schwachmeyer","year":"2013","unstructured":"Schwachmeyer V, Damm P, Bender A, Dymke J, Graichen F, Bergmann G. In vivo hip joint loading during post- operative physiotherapeutic exercises. PLoS One. 2013;8:e77807.","journal-title":"PLoS One"},{"key":"5006_CR18","doi-asserted-by":"publisher","first-page":"692","DOI":"10.1007\/s00402-004-0744-8","volume":"124","author":"B Hesse","year":"2004","unstructured":"Hesse B, G\u00e4chter A. Complications following the treatment of trochanteric fractures with the gamma nail. Arch Orthop Trauma Surg. 2004;124:692\u20138.","journal-title":"Arch Orthop Trauma Surg"},{"key":"5006_CR19","doi-asserted-by":"publisher","first-page":"754","DOI":"10.1302\/0301-620X.51B4.754","volume":"51","author":"M Laurence","year":"1969","unstructured":"Laurence M, Freeman MA, Swanson SA. Engineering considerations in the internal fixation of fractures of the tibial shaft. Bone Joint Surg Br. 1969;51:754\u201368.","journal-title":"Bone Joint Surg Br"},{"key":"5006_CR20","doi-asserted-by":"publisher","first-page":"2280","DOI":"10.2106\/00004623-200710000-00026","volume":"89","author":"HJ Jung","year":"2007","unstructured":"Jung HJ, Jung YB, Song KS, Park SJ, Lee JS. Fractures associated with computer-navigated total knee arthroplasty. A report of two cases. J Bone Joint Surg Am. 2007;89:2280\u20134.","journal-title":"J Bone Joint Surg Am"},{"key":"5006_CR21","doi-asserted-by":"publisher","first-page":"98","DOI":"10.3109\/10929088.2010.515419","volume":"15","author":"K Kim","year":"2010","unstructured":"Kim K, Kim YH, Park WM, Rhyu KH. Stress concentration near pin holes associated with fracture risk after computer navigated total knee arthroplasty. Comput Aided Surg. 2010;15:98\u2013103.","journal-title":"Comput Aided Surg"},{"key":"5006_CR22","doi-asserted-by":"publisher","first-page":"797","DOI":"10.1007\/s00402-010-1093-4","volume":"130","author":"KW Ho","year":"2010","unstructured":"Ho KW, Gilbody J, Jameson T, Miles AW. The effect of 4 mm bicortical drill hole defect on bone strength in a pig femur model. Arch Orthop Trauma Surg. 2010;130:797\u2013802.","journal-title":"Arch Orthop Trauma Surg"},{"key":"5006_CR23","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1186\/1749-799X-8-29","volume":"8","author":"MJ Fox","year":"2013","unstructured":"Fox MJ, Scarvell JM, Smith PN, Kalyanasundaram S, Stachurski ZH. Lateral drill holes decrease strength of the femur: an observational study using finite element and experimental analyses. J Orthop Surg Res. 2013;8:29.","journal-title":"J Orthop Surg Res"},{"key":"5006_CR24","first-page":"7867","volume":"10","author":"X Huang","year":"2017","unstructured":"Huang X, Yu B, Gu Y, Li Z. Biomechanical comparison of dynamic hip screw and gamma nail for the treatment of unstable trochanteric fractures: a finite element study. Int J Clin Exp Med. 2017;10:7867\u201374.","journal-title":"Int J Clin Exp Med"},{"key":"5006_CR25","doi-asserted-by":"publisher","first-page":"1116","DOI":"10.2106\/00004623-200207000-00004","volume":"84","author":"CM Robinson","year":"2002","unstructured":"Robinson CM, Adams CI, Craig M, Doward W, Clarke MC, Auld J. Implant-related fractures of the femur following hip fracture surgery. J Bone Joint Surg Am. 2002;84:1116\u201322.","journal-title":"J Bone Joint Surg Am"},{"key":"5006_CR26","doi-asserted-by":"publisher","first-page":"1959","DOI":"10.2147\/CIA.S96852","volume":"10","author":"\u015e Koyuncu","year":"2015","unstructured":"Koyuncu \u015e, Altay T, Kayal\u0131 C, Ozan F, Yamak K. Mechanical failures after fixation with proximal femoral nail and risk factors. Clin Interv Aging. 2015;10:1959\u201365.","journal-title":"Clin Interv Aging"},{"key":"5006_CR27","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1302\/0301-620X.77B2.7706346","volume":"77","author":"H Lacroix","year":"1995","unstructured":"Lacroix H, Arwert H, Snijders CJ, Fontijne WP. Prevention of fracture at the distal locking site of the gamma nail. A biomechanical study. J Bone Joint Surg (Br). 1995;77:274\u20136.","journal-title":"J Bone Joint Surg (Br)"},{"key":"5006_CR28","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1055\/s-2005-836301","volume":"13","author":"WY Shen","year":"2005","unstructured":"Shen WY. Complications with the gamma nail and long gamma nail, and their prevention. Osteo Trauma Care. 2005;13:34\u201341.","journal-title":"Osteo Trauma Care"},{"key":"5006_CR29","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1097\/BOT.0000000000000022","volume":"28","author":"SM Chang","year":"2014","unstructured":"Chang SM, Song DL, Ma Z, Tao YL, Chen WL, Zhang LZ, et al. Mismatch of the short straight cephalomedullary nail (PFNA-II) with the anterior bow of the femur in an Asian population. J Orthop Trauma. 2014;28:17\u201322.","journal-title":"J Orthop Trauma"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05006-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-022-05006-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05006-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,1,27]],"date-time":"2022-01-27T11:04:09Z","timestamp":1643281449000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-022-05006-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,27]]},"references-count":29,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["5006"],"URL":"https:\/\/doi.org\/10.1186\/s12891-022-05006-4","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-737483\/v1","asserted-by":"object"}]},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,27]]},"assertion":[{"value":"20 July 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 December 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 January 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that there are no conflicts of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"92"}}