{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T22:22:17Z","timestamp":1773267737861,"version":"3.50.1"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,2,7]],"date-time":"2022-02-07T00:00:00Z","timestamp":1644192000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,2,7]],"date-time":"2022-02-07T00:00:00Z","timestamp":1644192000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Objective<\/jats:title>\n                <jats:p>The screw path of lumbar pedicle screws in the vertebral body has certain variability. It is not clear whether the screw paths in different directions can obtain the same pull-out resistance. This study intends to use CT (Computed Tomography) to measure the Hounsfield unit (HU value) around the screw paths in different parts of the lumbar vertebral body to obtain the bone mineral density value of the corresponding parts which will provide some reference for the direction of lumbar pedicle screw placement.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>This retrospective study included 200 patients with lumbar degenerative diseases selected randomly from the case base and the patient\u2019s basic information was recorded. L1-L5 vertebral body was divided equally into the upper, middle and lower 1\/3, which was consistent with the three sagittal entry directions of the pedicle screw head tilt, parallel endplate and caudal tilt, and the HU values were measured by CT cross-sectional scanning to indirectly reflect the local bone density values. The paired t-test (randomized block experiment) was used to compare the HU values of the upper, middle and lower 1 \/ 3 parts, with <jats:italic>P<\/jats:italic>\u2009&lt;\u20090.05 being considered statistically significant.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Comparison of HU values in different parts of each vertebral body revealed that HU values in the middle 1\/3 of the L1,L2 (163.88\u2009\u00b1\u200958.44 and 152.94\u2009\u00b1\u200959.45) and in the lower 1\/3 of the L4 (149.86\u2009\u00b1\u200960.18) were higher than in the other two parts of the vertebral body of the same segment(<jats:italic>P<\/jats:italic>\u00a0&lt;\u20090.0001,<jats:italic>P<\/jats:italic>\u00a0=\u20090.0069 and <jats:italic>P<\/jats:italic>\u00a0=\u20090.0024, respectively); According to the results of each stratification, patients with younger age and better bone condition had higher HU values in the middle 1\/3 of L1 and L2, and higher HU values in the lower 1\/3 of L3, L4 and L5; With the increase of age, the decrease of bone condition and the difference of HU value in each vertebral body gradually decreased.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Although further follow-up studies are needed, based on the analysis of the statistical results, we speculate that from the perspective of obtaining the best pull-out resistance of the lumbar pedicle screws, the placement direction of L1 and L2 in the sagittal position may be as parallel to the endplate as possible; L3, L4, and L5 may be as appropriate as possible to the tail tilt theoretically.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-022-05074-6","type":"journal-article","created":{"date-parts":[[2022,2,7]],"date-time":"2022-02-07T10:03:45Z","timestamp":1644228225000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["A study of screw placement to obtain the optimal pull-out resistance of lumbar pedicle screws\u2014analysis of Hounsfield units measurements based on computed tomography"],"prefix":"10.1186","volume":"23","author":[{"given":"Dachuan","family":"Li","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chi","family":"Sun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianyuan","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Feizhou","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xinlei","family":"Xia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hongli","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fei","family":"Zou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaosheng","family":"Ma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,2,7]]},"reference":[{"key":"5074_CR1","doi-asserted-by":"publisher","first-page":"1335","DOI":"10.1097\/00007632-199111000-00015","volume":"16","author":"S Soshi","year":"1991","unstructured":"Soshi S, Shiba R, Kondo H, et al. An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine. 1991;16:1335\u201341.","journal-title":"Spine"},{"key":"5074_CR2","doi-asserted-by":"publisher","first-page":"43s","DOI":"10.1097\/00007632-199712151-00008","volume":"22","author":"SS Hu","year":"1997","unstructured":"Hu SS. Internal fixation in the osteoporotic spine. Spine. 1997;22:43s\u20138s.","journal-title":"Spine"},{"key":"5074_CR3","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1227\/01.NEU.0000103493.25162.18","volume":"54","author":"SA Salehi","year":"2004","unstructured":"Salehi SA, Tawk R, Ganju A, et al. Transforaminal lumbar interbody fusion: surgical technique and results in 24 patients. Neurosurgery. 2004;54:368\u201374 discussion 74.","journal-title":"Neurosurgery"},{"key":"5074_CR4","doi-asserted-by":"publisher","first-page":"1005","DOI":"10.1007\/s00586-015-3768-6","volume":"24","author":"F Galbusera","year":"2015","unstructured":"Galbusera F, Volkheimer D, Reitmaier S, et al. Pedicle screw loosening: a clinically relevant complication? Eur Spine J. 2015;24:1005\u201316.","journal-title":"Eur Spine J"},{"key":"5074_CR5","doi-asserted-by":"publisher","first-page":"1040","DOI":"10.1001\/jama.2017.21995","volume":"319","author":"KG Cotts","year":"2018","unstructured":"Cotts KG, Cifu AS. Treatment of osteoporosis. JAMA. 2018;319:1040\u20131.","journal-title":"JAMA"},{"issue":"Suppl 4","key":"5074_CR6","doi-asserted-by":"publisher","first-page":"S92","DOI":"10.1227\/NEU.0000000000000939","volume":"77","author":"D Lubelski","year":"2015","unstructured":"Lubelski D, Choma TJ, Steinmetz MP, et al. Perioperative medical management of spine surgery patients with osteoporosis. Neurosurgery. 2015;77(Suppl 4):S92\u20137.","journal-title":"Neurosurgery"},{"key":"5074_CR7","doi-asserted-by":"publisher","first-page":"1061","DOI":"10.1302\/0301-620X.92B8.24237","volume":"92","author":"W Cho","year":"2010","unstructured":"Cho W, Cho SK, Wu C. The biomechanics of pedicle screw-based instrumentation. J Bone Joint Surg. 2010;92:1061\u20135.","journal-title":"J Bone Joint Surg"},{"key":"5074_CR8","doi-asserted-by":"publisher","first-page":"366","DOI":"10.1016\/j.spinee.2008.07.008","volume":"9","author":"BG Santoni","year":"2009","unstructured":"Santoni BG, Hynes RA, McGilvray KC, et al. Cortical bone trajectory for lumbar pedicle screws. Spine J. 2009;9:366\u201373.","journal-title":"Spine J"},{"key":"5074_CR9","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.2106\/JBJS.J.00160","volume":"93","author":"JJ Schreiber","year":"2011","unstructured":"Schreiber JJ, Anderson PA, Rosas HG, et al. Hounsfield units for assessing bone mineral density and strength: a tool for osteoporosis management. J Bone Joint Surg Am. 2011;93:1057\u201363.","journal-title":"J Bone Joint Surg Am"},{"key":"5074_CR10","doi-asserted-by":"publisher","first-page":"E4","DOI":"10.3171\/2014.5.FOCUS1483","volume":"37","author":"JJ Schreiber","year":"2014","unstructured":"Schreiber JJ, Anderson PA, Hsu WK. Use of computed tomography for assessing bone mineral density. Neurosurg Focus. 2014;37:E4.","journal-title":"Neurosurg Focus"},{"key":"5074_CR11","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1007\/s00701-017-3424-5","volume":"160","author":"K Matsukawa","year":"2018","unstructured":"Matsukawa K, Abe Y, Yanai Y, et al. Regional Hounsfield unit measurement of screw trajectory for predicting pedicle screw fixation using cortical bone trajectory: a retrospective cohort study. Acta Neurochir. 2018;160:405\u201311.","journal-title":"Acta Neurochir"},{"key":"5074_CR12","doi-asserted-by":"publisher","first-page":"1063","DOI":"10.1007\/s00402-016-2487-8","volume":"136","author":"J Bredow","year":"2016","unstructured":"Bredow J, Boese CK, Werner CM, et al. Predictive validity of preoperative CT scans and the risk of pedicle screw loosening in spinal surgery. Arch Orthop Trauma Surg. 2016;136:1063\u20137.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"Suppl 1 Pt 1","key":"5074_CR13","doi-asserted-by":"publisher","first-page":"77","DOI":"10.2106\/JBJS.I.01300","volume":"92","author":"SD Glassman","year":"2010","unstructured":"Glassman SD, Carreon L, Dimar JR. Outcome of lumbar arthrodesis in patients sixty-five years of age or older. Surgical technique. J Bone Joint Surg. 2010;92(Suppl 1 Pt 1):77\u201384.","journal-title":"J Bone Joint Surg"},{"key":"5074_CR14","doi-asserted-by":"publisher","first-page":"588","DOI":"10.7326\/0003-4819-158-8-201304160-00003","volume":"158","author":"PJ Pickhardt","year":"2013","unstructured":"Pickhardt PJ, Pooler BD, Lauder T, et al. Opportunistic screening for osteoporosis using abdominal computed tomography scans obtained for other indications. Ann Intern Med. 2013;158:588\u201395.","journal-title":"Ann Intern Med"},{"key":"5074_CR15","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1186\/s13018-019-1169-y","volume":"14","author":"R Zhang","year":"2019","unstructured":"Zhang R, Gao H, Li H, et al. Differences in bone mineral density of trajectory between lumbar cortical and traditional pedicle screws. J Orthop Surg Res. 2019;14:128.","journal-title":"J Orthop Surg Res"},{"key":"5074_CR16","doi-asserted-by":"publisher","first-page":"2194","DOI":"10.1002\/jbmr.428","volume":"26","author":"PJ Pickhardt","year":"2011","unstructured":"Pickhardt PJ, Lee LJ, del Rio AM, et al. Simultaneous screening for osteoporosis at CT colonography: bone mineral density assessment using MDCT attenuation techniques compared with the DXA reference standard. J Bone Mineral Res. 2011;26:2194\u2013203.","journal-title":"J Bone Mineral Res"},{"key":"5074_CR17","doi-asserted-by":"publisher","first-page":"1443","DOI":"10.1016\/j.spinee.2019.04.013","volume":"19","author":"C Jia","year":"2019","unstructured":"Jia C, Zhang R, Xing T, et al. Biomechanical properties of pedicle screw fixation augmented with allograft bone particles in osteoporotic vertebrae: different sizes and amounts. Spine J. 2019;19:1443\u201352.","journal-title":"Spine J"},{"key":"5074_CR18","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1016\/j.jocd.2007.12.010","volume":"11","author":"K Engelke","year":"2008","unstructured":"Engelke K, Adams JE, Armbrecht G, et al. Clinical use of quantitative computed tomography and peripheral quantitative computed tomography in the management of osteoporosis in adults: the 2007 ISCD Official Positions. J Clin Densitomet. 2008;11:123\u201362.","journal-title":"J Clin Densitomet"},{"key":"5074_CR19","doi-asserted-by":"publisher","first-page":"1628","DOI":"10.3174\/ajnr.A3893","volume":"35","author":"BJ Schwaiger","year":"2014","unstructured":"Schwaiger BJ, Gersing AS, Baum T, et al. Bone mineral density values derived from routine lumbar spine multidetector row CT predict osteoporotic vertebral fractures and screw loosening. AJNR Am J Neuroradiol. 2014;35:1628\u201333.","journal-title":"AJNR Am J Neuroradiol"},{"key":"5074_CR20","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1016\/S1529-9430(01)00078-X","volume":"1","author":"K Okuyama","year":"2001","unstructured":"Okuyama K, Abe E, Suzuki T, et al. Influence of bone mineral density on pedicle screw fixation: a study of pedicle screw fixation augmenting posterior lumbar interbody fusion in elderly patients. Spine J. 2001;1:402\u20137.","journal-title":"Spine J"},{"key":"5074_CR21","doi-asserted-by":"publisher","first-page":"130","DOI":"10.5435\/00124635-200803000-00004","volume":"16","author":"CP DiPaola","year":"2008","unstructured":"DiPaola CP, Molinari RW. Posterior lumbar interbody fusion. J Am Acad Orthopaed Surg. 2008;16:130\u20139.","journal-title":"J Am Acad Orthopaed Surg"},{"key":"5074_CR22","doi-asserted-by":"publisher","first-page":"548","DOI":"10.21037\/jss.2017.09.05","volume":"3","author":"\u00d6 Demir","year":"2017","unstructured":"Demir \u00d6, \u00d6ks\u00fcz E, Deniz FE, et al. Assessing the effects of lumbar posterior stabilization and fusion to vertebral bone density in stabilized and adjacent segments by using Hounsfield unit. J Spine Surg. 2017;3:548\u201353.","journal-title":"J Spine Surg"},{"key":"5074_CR23","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.1016\/j.joca.2015.03.028","volume":"23","author":"PP Vergroesen","year":"2015","unstructured":"Vergroesen PP, Kingma I, Emanuel KS, et al. Mechanics and biology in intervertebral disc degeneration: a vicious circle. Osteoarthr Cartil. 2015;23:1057\u201370.","journal-title":"Osteoarthr Cartil"},{"key":"5074_CR24","doi-asserted-by":"publisher","first-page":"E473","DOI":"10.1097\/BSD.0000000000000703","volume":"31","author":"K Ishikawa","year":"2018","unstructured":"Ishikawa K, Toyone T, Shirahata T, et al. A novel method for the prediction of the pedicle screw stability: regional bone mineral density around the screw. Clin Spine Surg. 2018;31:E473\u2013e80.","journal-title":"Clin Spine Surg"},{"key":"5074_CR25","doi-asserted-by":"publisher","first-page":"1105","DOI":"10.1007\/s00586-020-06386-8","volume":"29","author":"D Zou","year":"2020","unstructured":"Zou D, Sun Z, Zhou S, et al. Hounsfield units value is a better predictor of pedicle screw loosening than the T-score of DXA in patients with lumbar degenerative diseases. Eur Spine J. 2020;29:1105\u201311.","journal-title":"Eur Spine J"},{"key":"5074_CR26","doi-asserted-by":"publisher","first-page":"734","DOI":"10.1016\/j.jos.2018.04.006","volume":"23","author":"Y Sakai","year":"2018","unstructured":"Sakai Y, Takenaka S, Matsuo Y, et al. Hounsfield unit of screw trajectory as a predictor of pedicle screw loosening after single level lumbar interbody fusion. J Orthopaed Sci. 2018;23:734\u20138.","journal-title":"J Orthopaed Sci"},{"key":"5074_CR27","first-page":"3906","volume":"12","author":"RJ Zhang","year":"2020","unstructured":"Zhang RJ, Li HM, Gao H, et al. Associations between the hounsfield unit values of different trajectories and bone mineral density of vertebrae: cortical bone and traditional trajectories. Am J Transl Res. 2020;12:3906\u201316.","journal-title":"Am J Transl Res"},{"key":"5074_CR28","doi-asserted-by":"publisher","first-page":"1714","DOI":"10.1007\/s00330-014-3529-7","volume":"25","author":"JL Wichmann","year":"2015","unstructured":"Wichmann JL, Booz C, Wesarg S, et al. Quantitative dual-energy CT for phantomless evaluation of cancellous bone mineral density of the vertebral pedicle: correlation with pedicle screw pull-out strength. Eur Radiol. 2015;25:1714\u201320.","journal-title":"Eur Radiol"},{"key":"5074_CR29","doi-asserted-by":"publisher","first-page":"E10","DOI":"10.3171\/2020.5.FOCUS20249","volume":"49","author":"F Xu","year":"2020","unstructured":"Xu F, Zou D, Li W, et al. Hounsfield units of the vertebral body and pedicle as predictors of pedicle screw loosening after degenerative lumbar spine surgery. Neurosurg Focus. 2020;49:E10.","journal-title":"Neurosurg Focus"},{"key":"5074_CR30","doi-asserted-by":"publisher","first-page":"2s","DOI":"10.1097\/00007632-199712151-00002","volume":"22","author":"LJ Melton 3rd","year":"1997","unstructured":"Melton LJ 3rd. Epidemiology of spinal osteoporosis. Spine. 1997;22:2s\u201311s.","journal-title":"Spine"},{"key":"5074_CR31","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1016\/j.spinee.2009.02.005","volume":"9","author":"CP Dipaola","year":"2009","unstructured":"Dipaola CP, Bible JE, Biswas D, et al. Survey of spine surgeons on attitudes regarding osteoporosis and osteomalacia screening and treatment for fractures, fusion surgery, and pseudoarthrosis. Spine J. 2009;9:537\u201344.","journal-title":"Spine J"},{"key":"5074_CR32","doi-asserted-by":"publisher","first-page":"3605","DOI":"10.1177\/0300060518776067","volume":"46","author":"P Wang","year":"2018","unstructured":"Wang P, Wang F, Gao YL, et al. Lumbar spondylolisthesis is a risk factor for osteoporotic vertebral fractures: a case-control study. J Int Med Res. 2018;46:3605\u201312.","journal-title":"J Int Med Res"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05074-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-022-05074-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05074-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,2,7]],"date-time":"2022-02-07T10:06:03Z","timestamp":1644228363000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-022-05074-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,7]]},"references-count":32,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["5074"],"URL":"https:\/\/doi.org\/10.1186\/s12891-022-05074-6","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,7]]},"assertion":[{"value":"20 September 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 January 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 February 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by the ethical committee of Huashan Hospital, Fudan University. All procedures performed in studies involving human participants were in accordance with the ethical standards of institutional and\/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. Written informed consent was obtained from all patients included in this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Each author certifies that he or she has no commercial associations (eg, consultancies, stock ownership, equity interest, patent\/licensing arrangements, etc.) that might pose a conflict of interest in connection with the submitted article.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"124"}}