{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T20:23:51Z","timestamp":1788553431652,"version":"build-2803163510"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,2,21]],"date-time":"2022-02-21T00:00:00Z","timestamp":1645401600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,2,21]],"date-time":"2022-02-21T00:00:00Z","timestamp":1645401600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Pedicle screw placement in patients with osteoporosis is a serious clinical challenge. The bone mineral density (BMD) of the screw trajectory has been positively correlated with the screw pull-out force, while the computer tomography (CT) value has been linearly correlated with the BMD. The purpose of this study was to establish an in vitro osteoporosis model and verify the accuracy and effectiveness of automated pedicle screw planning software based on CT values in this model.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Ten vertebrae (L1-L5) of normal adult pigs were randomly divided into decalcification and control groups. In the decalcification group, the vertebral bodies were decalcified with Ethylenediaminetetraacetic acid (EDTA) to construct an in vitro osteoporosis model. In the decalcification group, automatic planning (AP) and conventional manual planning (MP) were used to plan the pedicle screw trajectory on the left and right sides of the pedicle, respectively, and MP was used on both sides of the control group. CT values of trajectories obtained by the two methods were measured and compared. Then, 3D-printed guide plates were designed to assist pedicle screw placement. Finally, the pull-out force of the trajectory obtained by the two methods was measured.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>After decalcification, the BMD of the vertebra decreased from \u2212\u20090.03\u2009\u00b1\u20091.03 to \u2212\u20093.03\u2009\u00b1\u20090.29 (<jats:italic>P<\/jats:italic>\u00a0&lt;\u20090.05). In the decalcification group, the MP trajectory CT value was 2167.28\u2009\u00b1\u200965.62 Hu, the AP trajectory CT value was 2723.96\u2009\u00b1\u2009165.83 Hu, and the MP trajectory CT value in the control group was 2242.94\u2009\u00b1\u200925.80 Hu (<jats:italic>P<\/jats:italic>\u00a0&lt;\u20090.05). In the decalcified vertebrae, the screw pull-out force of the MP group was 48.6% lower than that of the control group (<jats:italic>P<\/jats:italic>\u00a0&lt;\u20090.05). The pull-out force of the AP trajectory was 44.7% higher than that of the MP trajectory (<jats:italic>P<\/jats:italic>\u00a0&lt;\u20090.05) and reached 97.4% of the MP trajectory in the control group (<jats:italic>P<\/jats:italic>\u00a0&gt;\u20090.05).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Automatic planning of the pedicle screw trajectory based on the CT value can obtain a higher screw pull-out force, which is a valuable new method of pedicle screw placement in osteoporotic vertebre.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-022-05101-6","type":"journal-article","created":{"date-parts":[[2022,2,21]],"date-time":"2022-02-21T18:10:51Z","timestamp":1645467051000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["The accuracy and effectiveness of automatic pedicle screw trajectory planning based on computer tomography values: an in vitro osteoporosis model study"],"prefix":"10.1186","volume":"23","author":[{"given":"Jia Bin","family":"Liu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rui","family":"Zuo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wen Jie","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chang Qing","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chao","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yue","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,2,21]]},"reference":[{"issue":"21","key":"5101_CR1","doi-asserted-by":"publisher","first-page":"2415","DOI":"10.1097\/00007632-199411000-00008","volume":"19","author":"TL Halvorson","year":"1994","unstructured":"Halvorson TL, Kelley LA, Thomas KA, Whitecloud TS 3rd, Cook SD. Effects of bone mineral density on pedicle screw fixation. Spine (Phila Pa 1976). 1994;19(21):2415\u201320.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"3","key":"5101_CR2","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1016\/j.bone.2011.11.027","volume":"50","author":"D Ruffoni","year":"2012","unstructured":"Ruffoni D, Wirth AJ, Steiner JA, Parkinson IH, M\u00fcller R, van Lenthe GH. The different contributions of cortical and trabecular bone to implant anchorage in a human vertebra. Bone. 2012;50(3):733\u20138.","journal-title":"Bone"},{"issue":"19","key":"5101_CR3","doi-asserted-by":"publisher","first-page":"E925","DOI":"10.1097\/BRS.0b013e3181c5fb21","volume":"35","author":"XM Zhuang","year":"2010","unstructured":"Zhuang XM, Yu BS, Zheng ZM, Zhang JF, Lu WW. Effect of the degree of osteoporosis on the biomechanical anchoring strength of the sacral pedicle screws: an in vitro comparison between unaugmented bicortical screws and polymethylmethacrylate augmented unicortical screws. Spine (Phila Pa 1976). 2010;35(19):E925\u201331.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"6","key":"5101_CR4","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1016\/S1529-9430(01)00078-X","volume":"1","author":"K Okuyama","year":"2001","unstructured":"Okuyama K, Abe E, Suzuki T, Tamura Y, Chiba M, Sato K. Influence of bone mineral density on pedicle screw fixation: a study of pedicle screw fixation augmenting posterior lumbar interbody fusion in elderly patients. Spine J. 2001;1(6):402\u20137.","journal-title":"Spine J"},{"issue":"1","key":"5101_CR5","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1016\/j.spinee.2010.09.024","volume":"11","author":"KE Ponnusamy","year":"2011","unstructured":"Ponnusamy KE, Iyer S, Gupta G, Khanna AJ. Instrumentation of the osteoporotic spine: biomechanical and clinical considerations. Spine J. 2011;11(1):54\u201363.","journal-title":"Spine J"},{"issue":"5","key":"5101_CR6","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1177\/0391398820964483","volume":"44","author":"P Jain","year":"2021","unstructured":"Jain P, Khan MR. Selection of suitable pedicle screw for degenerated cortical and cancellous bone of human lumbar spine: A finite element study. Int J Artif Organs. 2021;44(5):361\u20136.","journal-title":"Int J Artif Organs"},{"issue":"8","key":"5101_CR7","doi-asserted-by":"publisher","first-page":"1192","DOI":"10.1016\/j.spinee.2017.04.029","volume":"17","author":"M Mart\u00edn-Fern\u00e1ndez","year":"2017","unstructured":"Mart\u00edn-Fern\u00e1ndez M, L\u00f3pez-Herrad\u00f3n A, Pi\u00f1era AR, Tom\u00e9-Bermejo F, Duart JM, Vlad MD, et al. Potential risks of using cement-augmented screws for spinal fusion in patients with low bone quality. Spine J. 2017;17(8):1192\u20139.","journal-title":"Spine J"},{"key":"5101_CR8","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1016\/j.jbiomech.2017.10.009","volume":"70","author":"DM Lai","year":"2018","unstructured":"Lai DM, Shih YT, Chen YH, Chien A, Wang JL. Effect of pedicle screw diameter on screw fixation efficacy in human osteoporotic thoracic vertebrae. J Biomech. 2018;70:196\u2013203.","journal-title":"J Biomech"},{"issue":"2","key":"5101_CR9","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1016\/j.jmbbm.2007.06.004","volume":"1","author":"SH Teoh","year":"2008","unstructured":"Teoh SH, Chui CK. Bone material properties and fracture analysis: needle insertion for spinal surgery. J Mech Behav Biomed Mater. 2008;1(2):115\u201339.","journal-title":"J Mech Behav Biomed Mater"},{"issue":"4","key":"5101_CR10","doi-asserted-by":"publisher","first-page":"042002","DOI":"10.1088\/2057-1976\/ab9dd2","volume":"6","author":"P Jain","year":"2020","unstructured":"Jain P, Rana M, Biswas JK, Khan MR. Biomechanics of spinal implants-a review. Biomed Phys Eng Express. 2020;6(4):042002.","journal-title":"Biomed Phys Eng Express"},{"issue":"10","key":"5101_CR11","doi-asserted-by":"publisher","first-page":"1013","DOI":"10.1016\/S0021-9290(99)00099-8","volume":"32","author":"DD Cody","year":"1999","unstructured":"Cody DD, Gross GJ, Hou FJ, Spencer HJ, Goldstein SA, Fyhrie DP. Femoral strength is better predicted by finite element models than QCT and DXA. J Biomech. 1999;32(10):1013\u201320.","journal-title":"J Biomech"},{"issue":"5","key":"5101_CR12","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1016\/1350-4533(95)97314-F","volume":"17","author":"JY Rho","year":"1995","unstructured":"Rho JY, Hobatho MC, Ashman RB. Relations of mechanical properties to density and CT numbers in human bone. Med Eng Phys. 1995;17(5):347\u201355.","journal-title":"Med Eng Phys"},{"issue":"9","key":"5101_CR13","doi-asserted-by":"publisher","first-page":"1159","DOI":"10.1016\/0021-9290(94)90056-6","volume":"27","author":"TS Keller","year":"1994","unstructured":"Keller TS. Predicting the compressive mechanical behavior of bone. J Biomech. 1994;27(9):1159\u201368.","journal-title":"J Biomech"},{"issue":"7","key":"5101_CR14","doi-asserted-by":"publisher","first-page":"954","DOI":"10.2106\/00004623-197759070-00021","volume":"59","author":"DR Carter","year":"1977","unstructured":"Carter DR, Hayes WC. The compressive behavior of bone as a two-phase porous structure. J Bone Joint Surg Am. 1977;59(7):954\u201362.","journal-title":"J Bone Joint Surg Am"},{"issue":"3","key":"5101_CR15","doi-asserted-by":"publisher","first-page":"1325","DOI":"10.1007\/s13369-017-2848-9","volume":"43","author":"P Jain","year":"2018","unstructured":"Jain P, Khan MR. Biomechanical Study of Fused Lumbar Spine Considering Bone Degeneracy Using FEA. Arab J Sci Eng. 2018;43(3):1325\u201334.","journal-title":"Arab J Sci Eng"},{"issue":"8","key":"5101_CR16","doi-asserted-by":"publisher","first-page":"1918","DOI":"10.1007\/s00586-018-5587-z","volume":"27","author":"T Tajsic","year":"2018","unstructured":"Tajsic T, Patel K, Farmer R, Mannion RJ, Trivedi RA. Spinal navigation for minimally invasive thoracic and lumbosacral spine fixation: implications for radiation exposure, operative time, and accuracy of pedicle screw placement. Eur Spine J. 2018;27(8):1918\u201324.","journal-title":"Eur Spine J"},{"issue":"6","key":"5101_CR17","doi-asserted-by":"publisher","first-page":"1420","DOI":"10.1109\/TMI.2016.2514530","volume":"35","author":"D Knez","year":"2016","unstructured":"Knez D, Likar B, Pernus F, Vrtovec T. Computer-Assisted Screw Size and Insertion Trajectory Planning for Pedicle Screw Placement Surgery. IEEE Trans Med Imaging. 2016;35(6):1420\u201330.","journal-title":"IEEE Trans Med Imaging"},{"issue":"7","key":"5101_CR18","doi-asserted-by":"publisher","first-page":"2871","DOI":"10.1088\/1361-6560\/aa5f42","volume":"62","author":"J Goerres","year":"2017","unstructured":"Goerres J, Uneri A, De Silva T, Ketcha M, Reaungamornrat S, Jacobson M, et al. Spinal pedicle screw planning using deformable atlas registration. Phys Med Biol. 2017;62(7):2871\u201391.","journal-title":"Phys Med Biol"},{"issue":"3","key":"5101_CR19","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1002\/rcs.1413","volume":"8","author":"J Lee","year":"2012","unstructured":"Lee J, Kim S, Kim YS, Chung WK. Optimal surgical planning guidance for lumbar spinal fusion considering operational safety and vertebra-screw interface strength. Int J Med Robot. 2012;8(3):261\u201372.","journal-title":"Int J Med Robot"},{"key":"5101_CR20","first-page":"1487","volume":"2004","author":"R Wicker","year":"2004","unstructured":"Wicker R, Tedla B. Automatic determination of pedicle screw size, length, and trajectory from patient data. Conf Proc IEEE Eng Med Biol Soc. 2004;2004:1487\u201390.","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"5101_CR21","unstructured":"Liu JB, Xia GF, Zuo R. Automatic pedicle screw trajectory planning for osteoporosis. China Medical Equipment.  In process."},{"issue":"4","key":"5101_CR22","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1016\/j.spinee.2016.10.020","volume":"17","author":"D Guha","year":"2017","unstructured":"Guha D, Jakubovic R, Gupta S, Alotaibi NM, Cadotte D, da Costa LB, et al. Spinal intraoperative three-dimensional navigation: correlation between clinical and absolute engineering accuracy. Spine J. 2017;17(4):489\u201398.","journal-title":"Spine J"},{"issue":"6","key":"5101_CR23","doi-asserted-by":"publisher","first-page":"1217","DOI":"10.1016\/S0736-0266(02)00069-4","volume":"20","author":"NN Aldini","year":"2002","unstructured":"Aldini NN, Fini M, Giavaresi G, Giardino R, Greggi T, Parisini P. Pedicular fixation in the osteoporotic spine: a pilot in vivo study on long-term ovariectomized sheep. J Orthop Res. 2002;20(6):1217\u201324.","journal-title":"J Orthop Res"},{"issue":"4","key":"5101_CR24","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1016\/j.bone.2005.05.002","volume":"37","author":"S Schorlemmer","year":"2005","unstructured":"Schorlemmer S, Ignatius A, Claes L, Augat P. Inhibition of cortical and cancellous bone formation in glucocorticoid-treated OVX sheep. Bone. 2005;37(4):491\u20136.","journal-title":"Bone"},{"key":"5101_CR25","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1016\/j.clinbiomech.2019.12.013","volume":"72","author":"Y Shibasaki","year":"2020","unstructured":"Shibasaki Y, Tsutsui S, Yamamoto E, Murakami K, Yoshida M, Yamada H. A bicortical pedicle screw in the caudad trajectory is the best option for the fixation of an osteoporotic vertebra: An in-vitro experimental study using synthetic lumbar osteoporotic bone models. Clin Biomech (Bristol, Avon). 2020;72:150\u20134.","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"6","key":"5101_CR26","doi-asserted-by":"publisher","first-page":"789","DOI":"10.3171\/2010.12.SPINE10453","volume":"14","author":"CY Lee","year":"2011","unstructured":"Lee CY, Chan SH, Lai HY, Lee ST. A method to develop an in vitro osteoporosis model of porcine vertebrae: histological and biomechanical study. J Neurosurg Spine. 2011;14(6):789\u201398.","journal-title":"J Neurosurg Spine"},{"issue":"1","key":"5101_CR27","doi-asserted-by":"publisher","first-page":"274","DOI":"10.1186\/s12891-020-03309-y","volume":"21","author":"YC Tang","year":"2020","unstructured":"Tang YC, Guo HZ, Guo DQ, Luo PJ, Li YX, Mo GY, et al. Effect and potential risks of using multilevel cement-augmented pedicle screw fixation in osteoporotic spine with lumbar degenerative disease. BMC Musculoskelet Disord. 2020;21(1):274.","journal-title":"BMC Musculoskelet Disord"},{"issue":"10","key":"5101_CR28","doi-asserted-by":"publisher","first-page":"1395","DOI":"10.1007\/s00402-020-03382-x","volume":"140","author":"M Trost","year":"2020","unstructured":"Trost M, Schmoelz W, Wimmer D, H\u00f6rmann R, Frey S, Schulte TL. Local osteo-enhancement of osteoporotic vertebra with a triphasic bone implant material increases strength-a biomechanical study. Arch Orthop Trauma Surg. 2020;140(10):1395\u2013401.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"10","key":"5101_CR29","doi-asserted-by":"publisher","first-page":"2196","DOI":"10.1007\/s00586-014-3476-7","volume":"23","author":"RA Kueny","year":"2014","unstructured":"Kueny RA, Kolb JP, Lehmann W, P\u00fcschel K, Morlock MM, Huber G. Influence of the screw augmentation technique and a diameter increase on pedicle screw fixation in the osteoporotic spine: pull-out versus fatigue testing. Eur Spine J. 2014;23(10):2196\u2013202.","journal-title":"Eur Spine J"},{"issue":"21","key":"5101_CR30","doi-asserted-by":"publisher","first-page":"1487","DOI":"10.1097\/BRS.0000000000002659","volume":"43","author":"D Knez","year":"2018","unstructured":"Knez D, Mohar J, Cirman RJ, Likar B, Pernu\u0161 F, Vrtovec T. Variability Analysis of Manual and Computer-Assisted Preoperative Thoracic Pedicle Screw Placement Planning. Spine (Phila Pa 1976). 2018;43(21):1487\u201395.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"sup1","key":"5101_CR31","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1080\/24699322.2016.1240301","volume":"21","author":"C Xiaozhao","year":"2016","unstructured":"Xiaozhao C, Jinfeng H, Baolin M, Chongnan Y, Yan K. A method of lumbar pedicle screw placement optimization applied to guidance techniques. Comput Assist Surg. 2016;21(sup1):142\u20137.","journal-title":"Comput Assist Surg"},{"issue":"16","key":"5101_CR32","doi-asserted-by":"publisher","first-page":"165020","DOI":"10.1088\/1361-6560\/ab2d66","volume":"64","author":"R Vijayan","year":"2019","unstructured":"Vijayan R, De Silva T, Han R, Zhang X, Uneri A, Doerr S, et al. Automatic pedicle screw planning using atlas-based registration of anatomy and reference trajectories. Phys Med Biol. 2019;64(16):165020.","journal-title":"Phys Med Biol"},{"issue":"18","key":"5101_CR33","doi-asserted-by":"publisher","first-page":"2058","DOI":"10.1097\/01.BRS.0000087743.57439.4F","volume":"28","author":"RA Lehman Jr","year":"2003","unstructured":"Lehman RA Jr, Polly DW Jr, Kuklo TR, Cunningham B, Kirk KL, Belmont PJ Jr. Straight-forward versus anatomic trajectory technique of thoracic pedicle screw fixation: a biomechanical analysis. Spine (Phila Pa 1976). 2003;28(18):2058\u201365.","journal-title":"Spine (Phila Pa 1976)"},{"issue":"8","key":"5101_CR34","doi-asserted-by":"publisher","first-page":"1443","DOI":"10.1016\/j.spinee.2019.04.013","volume":"19","author":"C Jia","year":"2019","unstructured":"Jia C, Zhang R, Xing T, Gao H, Li H, Dong F, et al. Biomechanical properties of pedicle screw fixation augmented with allograft bone particles in osteoporotic vertebrae: different sizes and amounts. Spine J. 2019;19(8):1443\u201352.","journal-title":"Spine J"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05101-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-022-05101-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05101-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,2,21]],"date-time":"2022-02-21T18:17:24Z","timestamp":1645467444000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-022-05101-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,21]]},"references-count":34,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["5101"],"URL":"https:\/\/doi.org\/10.1186\/s12891-022-05101-6","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,21]]},"assertion":[{"value":"4 November 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 February 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 February 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All experimental protocols were approved by institutional ethics committee of the Xinqiao Hospital (Chongqing, China). All methods were carried out in accordance with relevant guidelines and regulations. This study was carried out in compliance with the ARRIVE guidelines.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"165"}}