{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,14]],"date-time":"2026-03-14T06:22:05Z","timestamp":1773469325483,"version":"3.50.1"},"reference-count":11,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,3,26]],"date-time":"2022-03-26T00:00:00Z","timestamp":1648252800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,3,26]],"date-time":"2022-03-26T00:00:00Z","timestamp":1648252800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Percutaneous screw placement, especially the insertion of LC2 screws, is technically demanding. Although the traditional LC2 bony canal spans the anterior inferior iliac spine (AIIS) to the posterior superior iliac spines (PSIS), a high perforation rate has been reported.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Objection<\/jats:title>\n                <jats:p>The aim of this research was to design a revised bony canal, measure the canal width and length and guide the insertion of LC2 screws for pelvic fractures.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Materials and methods<\/jats:title>\n                <jats:p>The plane tool in the Mimics analysis menu was used to draw a midplane connecting the midpoint between the anterior inferior spine and the PSIS upper flat region with pelvic CT data. The minimum widths of the upper, middle, lower surfaces of the tunnel and perforation rate were measured and compared. The ideal screw length was also measured along the longitudinal axis running through the midpoint of the midplane.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The minimum widths of the upper, middle and lower surfaces of the revised canal were 3.63\u2009mm, 7.7\u2009mm, and 11.93\u2009mm, respectively, in males and 5.97\u2009mm, 9.93\u2009mm, and 12.45\u2009mm, respectively, in females. Significant differences were observed among the upper, middle and lower surfaces of the revised canal in male patients (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.001). In female subjects, the upper canal surface was significantly different from the middle and lower canal surfaces (P\u2009&lt;\u20090.001). The perforation rate was significantly decreased especially in females pelvic. The channel length passing through the midpoint of the narrowest position of the pelvis was 130.85\u2009\u00b1\u20098.02\u2009mm in males and 124.30\u2009\u00b1\u20097.71\u2009mm in females and was significantly different for male and female pelvises (<jats:italic>P<\/jats:italic>\u2009=\u20090.004).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The LC2 screw should be inserted along the intersection line of the AIIS lateral wall and the iliac body. The screw should be inserted under the line between the midpoint of the AIIS and the PSIS upper flat region to ensure accuracy of placement. LC2 screws can be more easily inserted in males than in females, and the rate of cortical perforation can be significantly decreased under the guidance of the newly proposed canal.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-022-05256-2","type":"journal-article","created":{"date-parts":[[2022,3,28]],"date-time":"2022-03-28T18:10:03Z","timestamp":1648491003000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["An exploratory study of pelvis anatomy to revise the bony canal used for LC2 screw insertion"],"prefix":"10.1186","volume":"23","author":[{"given":"Jialiang","family":"Guo","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Weichong","family":"Dong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhiwei","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ruipeng","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yingchao","family":"Yin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yingze","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhiyong","family":"Hou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,3,26]]},"reference":[{"key":"5256_CR1","doi-asserted-by":"publisher","first-page":"1615","DOI":"10.2106\/00004623-196446080-00001","volume":"46","author":"R Judet","year":"1964","unstructured":"Judet R, Judet J, Letournel E. Fractures of the acetabulum: classification and surgical approaches for open reduction. Preliminary report. J Bone Joint Surg Am. 1964;46:1615\u201346.","journal-title":"J Bone Joint Surg Am"},{"key":"5256_CR2","first-page":"222","volume":"307","author":"NA Ebraheim","year":"1994","unstructured":"Ebraheim NA, Coombs R, Jackson WT, Rusin JJ. Percutaneous computed tomography-guided stabilization of posterior pelvic fractures. Clin Orthop Relat Res. 1994;307:222\u20138.","journal-title":"Clin Orthop Relat Res"},{"key":"5256_CR3","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1097\/00005131-199506000-00005","volume":"9","author":"ML Routt Jr","year":"1995","unstructured":"Routt ML Jr, Kregor PJ, Simonian PT, Mayo KA. Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma. 1995;9:207\u201314.","journal-title":"J Orthop Trauma"},{"key":"5256_CR4","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1097\/BOT.0000000000000418","volume":"30","author":"A Lindsay","year":"2016","unstructured":"Lindsay A, Tornetta P 3rd, Diwan A, Templeman D. Is closed reduction and percutaneous fixation of unstable posterior ring injuries as accurate as open reduction and internal fixation? J Orthop Trauma. 2016;30:29\u201333.","journal-title":"J Orthop Trauma"},{"key":"5256_CR5","doi-asserted-by":"publisher","first-page":"E143","DOI":"10.1097\/00007632-200104010-00002","volume":"26","author":"JL Berry","year":"2001","unstructured":"Berry JL, Stahurski T, Asher MA. Morphometry of the supra sciatic notch intrailiac implant anchor passage. Spine (Phila Pa 1976). 2001;26:E143\u20138.","journal-title":"Spine (Phila Pa 1976)"},{"key":"5256_CR6","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1097\/00005131-200202000-00008","volume":"16","author":"AJ Starr","year":"2002","unstructured":"Starr AJ, Walter JC, Harris RW, Reinert CM, Jones AL. Percutaneous screw fixation of fractures of the iliac wing and fracture-dislocations of the sacro-iliac joint (OTA Types 61-B2.2 and 61-B2.3, or Young-Burgess \u201clateral compression type II\u201d pelvic fractures). J Orthop Trauma. 2002;16:116\u201323.","journal-title":"J Orthop Trauma"},{"key":"5256_CR7","doi-asserted-by":"publisher","first-page":"169","DOI":"10.3109\/10929080209146027","volume":"7","author":"AC Crowl","year":"2002","unstructured":"Crowl AC, Kahler DM. Closed reduction and percutaneous fixation of anterior column acetabular fractures. Comput Aided Surg. 2002;7:169\u201378.","journal-title":"Comput Aided Surg"},{"key":"5256_CR8","doi-asserted-by":"publisher","first-page":"396","DOI":"10.1016\/j.injury.2009.11.005","volume":"41","author":"T Suzuki","year":"2010","unstructured":"Suzuki T, Morgan SJ, Smith WR, Stahel PF, Gillani SA, Hak DJ. Postoperative surgical site infection following acetabular fracture fixation. Injury. 2010;41:396\u20139.","journal-title":"Injury"},{"key":"5256_CR9","first-page":"511","volume":"6","author":"Z Guo","year":"2019","unstructured":"Guo Z, Han T, Zhou D, Xue H, Peng L. Three ways of inserting the anterioinferior iliac spine channel screws: a computer simulation comparison. Zhonghua Chuang Shang Gu Ke Za Zhi (Chinese). 2019;6:511\u20135.","journal-title":"Zhonghua Chuang Shang Gu Ke Za Zhi (Chinese)"},{"key":"5256_CR10","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1097\/00024720-200206000-00005","volume":"15","author":"TA Schildhauer","year":"2002","unstructured":"Schildhauer TA, McCulloch P, Chapman JR, Mann FA. Anatomic and radiographic considerations for placement of transiliac screws in lumbopelvic fixations. J Spinal Disord Tech. 2002;15:199\u2013205.","journal-title":"J Spinal Disord Tech"},{"key":"5256_CR11","doi-asserted-by":"publisher","first-page":"S235","DOI":"10.1097\/00007632-199208001-00004","volume":"17","author":"DH McCord","year":"1992","unstructured":"McCord DH, Cunningham BW, Shono Y, Myers JJ, McAfee PC. Biomechanical analysis of lumbosacral fixation. Spine (Phila Pa 1976). 1992;17:S235\u201343.","journal-title":"Spine (Phila Pa 1976)"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05256-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-022-05256-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05256-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,3,28]],"date-time":"2022-03-28T18:14:37Z","timestamp":1648491277000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-022-05256-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,26]]},"references-count":11,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["5256"],"URL":"https:\/\/doi.org\/10.1186\/s12891-022-05256-2","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,26]]},"assertion":[{"value":"11 August 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 March 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 March 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethical approval for the study was received from the Regional Ethics Committee of the Third Hospital of Hebei Medical University and the study was conducted in accordance with the guidelines provided by the Declaration of Helsinki. Informed signed consent was obtained from all the patients who enrolled in the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declared that they have no conflicts of interest to this work.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"293"}}