{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,2,21]],"date-time":"2024-02-21T09:58:13Z","timestamp":1708509493663},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,4,4]],"date-time":"2022-04-04T00:00:00Z","timestamp":1649030400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,4,4]],"date-time":"2022-04-04T00:00:00Z","timestamp":1649030400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Flexor tendon injuries pose many challenges for the treating surgeon, the principal of which is creating a strong enough repair to allow early active motion, preserving a low-profile of the repair to prevent buckling and subsequent pulley venting. A main concern is that a low-profile repair is prone to gap formation and repair failure. The Dynamic Tendon Grip (DTG\u2122) all suture staple device claims to allow a strong and low-profile repair of the flexor tendon. The purpose of this study is to test the effects of the DTG\u2122 device in early active motion simulation on range of motion, load to failure and gap formation and to compare it to traditional suturing technique.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Twelve fresh-frozen cadaveric fingers were assigned to two groups: DTG\u2122 device (<jats:italic>n<\/jats:italic>\u2009=\u20099) and traditional suturing (double Kessler 4-core suture and a peripheral suture, <jats:italic>n<\/jats:italic>\u2009=\u20093). The deep flexor was incised and repaired in zone 2, and active motion simulation was carried out with a cyclic flexion\u2013extension machine. Finger range of motion and gap formation were measured, as well as load to failure and method of repair failure.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Following motion simulation, ROM decreased from 244.0\u2009\u00b1\u20099.9\u00b0 to 234.5\u2009\u00b1\u20095.8\u00b0 for the DTG\u2122 device compared to 234.67\u2009\u00b1\u20096.51\u00b0 to 211.67\u2009\u00b1\u200910.50\u00b0 for traditional suturing. The DTG\u2122 repair demonstrated gap formation of 0.93\u2009\u00b1\u20090.18\u00a0mm in 3 of 8 specimens after applying 1\u00a0kg load, which negated after load removal. Load to failure averaged 76.51\u2009\u00b1\u200923.15\u00a0N for DTG\u2122 and 66.31\u2009\u00b1\u200940.22\u00a0N for the traditional repair. Repair failure occurred as the suture material broke for the DTG\u2122 array and at the knot level for the traditional repair.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>The DTG\u2122 all-suture stapling concept achieved a strong low-profile repair in zone 2 flexor tendon injury after active motion simulation. Further clinical studies will be needed to determine the effectiveness of this device compared to traditional techniques.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-022-05279-9","type":"journal-article","created":{"date-parts":[[2022,4,4]],"date-time":"2022-04-04T10:04:17Z","timestamp":1649066657000},"update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Dynamic Tendon Grip (DTG\u2122) novel knot array compared to traditional sutures for zone two flexor tendon injury \u2013 a biomechanical feasibility study"],"prefix":"10.1186","volume":"23","author":[{"given":"Assaf","family":"Kadar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alon","family":"Fainzack","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mordechai","family":"Vigler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,4,4]]},"reference":[{"key":"5279_CR1","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1177\/1753193416657758","volume":"41","author":"IZ Rigo","year":"2016","unstructured":"Rigo IZ, R\u00f8kkum M. Predictors of outcome after primary flexor tendon repair in zone 1, 2 and 3. J Hand Surg Eur. 2016;41:793\u2013801. https:\/\/doi.org\/10.1177\/1753193416657758.","journal-title":"J Hand Surg Eur"},{"key":"5279_CR2","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1016\/j.jhsa.2011.11.006","volume":"37","author":"CJ Dy","year":"2012","unstructured":"Dy CJ, Hernandez-Soria A, Ma Y, Roberts TR, Daluiski A. Complications after flexor tendon repair: a systematic review and meta-analysis. J Hand Surg Am. 2012;37:543-551.e1. https:\/\/doi.org\/10.1016\/j.jhsa.2011.11.006.","journal-title":"J Hand Surg Am"},{"key":"5279_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.amsu.2019.10.006","volume":"48","author":"A Ishak","year":"2019","unstructured":"Ishak A, Rajangam A, Khajuria A. The evidence-base for the management of flexor tendon injuries of the hand: review. Ann Med Surg. 2019;48:1\u20136. https:\/\/doi.org\/10.1016\/j.amsu.2019.10.006.","journal-title":"Ann Med Surg"},{"key":"5279_CR4","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2013.05.015","author":"CJ Dy","year":"2013","unstructured":"Dy CJ, Lyman S, Schreiber JJ, Do HT, Daluiski A. The epidemiology of reoperation after flexor pulley reconstruction. J Hand Surg Am. 2013. https:\/\/doi.org\/10.1016\/j.jhsa.2013.05.015.","journal-title":"J Hand Surg Am"},{"key":"5279_CR5","doi-asserted-by":"publisher","DOI":"10.5435\/JAAOS-22-12-791","author":"CJ Dy","year":"2014","unstructured":"Dy CJ, Daluiski A. Update on zone II flexor tendon injuries. J Am Acad Orthop Surg. 2014. https:\/\/doi.org\/10.5435\/JAAOS-22-12-791.","journal-title":"J Am Acad Orthop Surg"},{"key":"5279_CR6","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2014.06.025","author":"A Chauhan","year":"2014","unstructured":"Chauhan A, Palmer BA, Merrell GA. Flexor tendon repairs: Techniques, eponyms, and evidence. J Hand Surg Am. 2014. https:\/\/doi.org\/10.1016\/j.jhsa.2014.06.025.","journal-title":"J Hand Surg Am"},{"key":"5279_CR7","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1016\/j.hcl.2013.02.003","volume":"29","author":"JB Tang","year":"2013","unstructured":"Tang JB, Amadio PC, Boyer MI, Savage R, Zhao C, Sandow M, et al. Current Practice of Primary Flexor Tendon Repair. A Global View Hand Clin. 2013;29:179\u201389. https:\/\/doi.org\/10.1016\/j.hcl.2013.02.003.","journal-title":"A Global View Hand Clin"},{"key":"5279_CR8","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/j.hcl.2013.02.001","volume":"29","author":"PC Amadio","year":"2013","unstructured":"Amadio PC. Gliding Resistance and Modifications of Gliding Surface of Tendon. Clinical Perspectives Hand Clin. 2013;29:159\u201366. https:\/\/doi.org\/10.1016\/j.hcl.2013.02.001.","journal-title":"Clinical Perspectives Hand Clin"},{"key":"5279_CR9","doi-asserted-by":"publisher","first-page":"975","DOI":"10.2106\/00004623-199907000-00010","volume":"81","author":"RH Gelberman","year":"1999","unstructured":"Gelberman RH, Boyer MI, Brodt MD, Winters SC, Silva MJ. The effect of gap formation at the repair site on the strength and excursion of intrasynovial flexor tendons an experimental study on the early stages of tendon-healing in dOGS*. J Bone Jt Surg. 1999;81:975\u201382. https:\/\/doi.org\/10.2106\/00004623-199907000-00010.","journal-title":"J Bone Jt Surg"},{"key":"5279_CR10","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1016\/j.jss.2017.03.035","volume":"216","author":"A Kadar","year":"2017","unstructured":"Kadar A, Thoreson AR, Reisdorf RL, Amadio PC, Moran SL, Zhao C. Turkey model for flexor tendon research: in vitro comparison of human, canine, turkey, and chicken tendons. J Surg Res. 2017;216:46\u201355. https:\/\/doi.org\/10.1016\/j.jss.2017.03.035.","journal-title":"J Surg Res"},{"key":"5279_CR11","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1016\/j.jhsa.2020.11.003","volume":"46","author":"A Kadar","year":"2021","unstructured":"Kadar A, Haddara MM, Fan S, Chinchalkar S, Ferreira LM, Suh N. Use of Thermoplastic Rings Following Venting of Flexor Tendon Pulleys: A Biomechanical Analysis. J Hand Surg Am. 2021;46:485\u201392. https:\/\/doi.org\/10.1016\/j.jhsa.2020.11.003.","journal-title":"J Hand Surg Am"},{"key":"5279_CR12","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1016\/j.jor.2020.09.001","volume":"21","author":"R De Vitis","year":"2020","unstructured":"De Vitis R, Passiatore M, Cilli V, Lazzerini A, Marzella L, Taccardo G. Feasibility of homodigital flexor digitorum superficialis transposition, a new technique for A2\u2013C1 pulleys reconstruction: a kinematic cadaver study. J Orthop. 2020;21:483\u20136. https:\/\/doi.org\/10.1016\/j.jor.2020.09.001.","journal-title":"J Orthop"},{"key":"5279_CR13","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1016\/j.clinbiomech.2018.12.007","volume":"62","author":"MK Chang","year":"2019","unstructured":"Chang MK, Lim ZY, Wong YR, Tay SC. A review of cyclic testing protocols for flexor tendon repairs. Clin Biomech. 2019;62:42\u20139. https:\/\/doi.org\/10.1016\/j.clinbiomech.2018.12.007.","journal-title":"Clin Biomech"},{"key":"5279_CR14","doi-asserted-by":"publisher","first-page":"2525","DOI":"10.1016\/j.jhsa.2014.06.005","volume":"39","author":"B Zafonte","year":"2014","unstructured":"Zafonte B, Rendulic D, Szabo RM. Flexor pulley system: anatomy, injury, and management. J Hand Surg Am. 2014;39:2525\u201332. https:\/\/doi.org\/10.1016\/j.jhsa.2014.06.005.","journal-title":"J Hand Surg Am"},{"key":"5279_CR15","doi-asserted-by":"publisher","DOI":"10.1016\/j.jhsa.2021.05.013","author":"HG Cox","year":"2021","unstructured":"Cox HG, Hill JB, Colon AF, Abbasi P, Giladi AM, Katz RD. The impact of dividing the flexor tendon pulleys on tendon excursion and work of flexion in a cadaveric model. J Hand Surg Am. 2021. https:\/\/doi.org\/10.1016\/j.jhsa.2021.05.013.","journal-title":"J Hand Surg Am"},{"key":"5279_CR16","unstructured":"Fox PM, Lalonde DH, Boyer MI, Amadio PC. Flexor Tendon Repair: Why Research Should Change Your Practice. 74th Annu. Meet. ASSH. Las Vegas: ASSH | American Society for Surgery of the Hand; 2019."},{"key":"5279_CR17","doi-asserted-by":"publisher","first-page":"96","DOI":"10.1002\/jor.1100040112","volume":"4","author":"WW Peterson","year":"1986","unstructured":"Peterson WW, Manske PR, Bollinger BA, Lesker PA, McCarthy JA. Effect of pulley excision on flexor tendon biomechanics. J Orthop Res. 1986;4:96\u2013101. https:\/\/doi.org\/10.1002\/jor.1100040112.","journal-title":"J Orthop Res"},{"key":"5279_CR18","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1016\/j.cps.2019.02.003","volume":"46","author":"JB Tang","year":"2019","unstructured":"Tang JB. Flexor tendon injuries. Clin Plast Surg. 2019;46:295\u2013306. https:\/\/doi.org\/10.1016\/j.cps.2019.02.003.","journal-title":"Clin Plast Surg"},{"key":"5279_CR19","doi-asserted-by":"publisher","first-page":"e99","DOI":"10.1016\/j.jhsa.2016.11.022","volume":"42","author":"PD Gibson","year":"2017","unstructured":"Gibson PD, Sobol GL, Ahmed IH. Zone II flexor tendon repairs in the United States: trends in current management. J Hand Surg Am. 2017;42:e99-108. https:\/\/doi.org\/10.1016\/j.jhsa.2016.11.022.","journal-title":"J Hand Surg Am"},{"key":"5279_CR20","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1016\/j.jhsa.2008.01.010","volume":"33","author":"T Waitayawinyu","year":"2008","unstructured":"Waitayawinyu T, Martineau PA, Luria S, Hanel DP, Trumble TE. Comparative biomechanic study of flexor tendon repair using fiberwire. J Hand Surg Am. 2008;33:701\u20138. https:\/\/doi.org\/10.1016\/j.jhsa.2008.01.010.","journal-title":"J Hand Surg Am"},{"issue":"Suppl 1","key":"5279_CR21","doi-asserted-by":"publisher","first-page":"37","DOI":"10.2106\/00004623-200603001-00005","volume":"88","author":"BW Su","year":"2006","unstructured":"Su BW, Solomons M, Barrow A, Senoge ME, Gilberti M, Lubbers L, et al. A device for zone-II flexor tendon repair. surgical technique. J Bone Joint Surg Am. 2006;88(Suppl 1):37\u201349. https:\/\/doi.org\/10.2106\/00004623-200603001-00005.","journal-title":"J Bone Joint Surg Am"},{"key":"5279_CR22","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1007\/s10195-008-0016-4","volume":"9","author":"L Rocchi","year":"2008","unstructured":"Rocchi L, Merolli A, Genzini A, Merendi G, Catalano F. Flexor tendon injuries of the hand treated with TenoFix\u2122: mid-term results. J Orthop Traumatol. 2008;9:201\u20138. https:\/\/doi.org\/10.1007\/s10195-008-0016-4.","journal-title":"J Orthop Traumatol"},{"key":"5279_CR23","doi-asserted-by":"publisher","first-page":"878.e1","DOI":"10.1016\/j.jhsa.2020.02.015","volume":"45","author":"CS Irwin","year":"2020","unstructured":"Irwin CS, Parks BG, Means KR. Biomechanical analysis of zone 2 flexor tendon repair with a coupler device versus locking cruciate core suture. J Hand Surg Am. 2020;45:878.e1-878.e6. https:\/\/doi.org\/10.1016\/j.jhsa.2020.02.015.","journal-title":"J Hand Surg Am"},{"key":"5279_CR24","unstructured":"Rosenwasser MP. Pivotal, Randomized, Controlled Trial to Evaluate the Safety and Effectiveness of the CoNextions\u00ae TR Tendon Repair System for Zone 2 Flexor Tendon Repair, 76th Annu. Meet. ASSH. San Francisco: ASSH | American Society for Surgery of the Hand; 2021. p. 122\u20135."},{"key":"5279_CR25","doi-asserted-by":"publisher","first-page":"1427","DOI":"10.1097\/PRS.0000000000004416","volume":"141","author":"JB Tang","year":"2018","unstructured":"Tang JB. New developments are improving flexor tendon repair. Plast Reconstr Surg. 2018;141:1427\u201337. https:\/\/doi.org\/10.1097\/PRS.0000000000004416.","journal-title":"Plast Reconstr Surg"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05279-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-022-05279-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05279-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,4,4]],"date-time":"2022-04-04T10:05:43Z","timestamp":1649066743000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-022-05279-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,4]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["5279"],"URL":"https:\/\/doi.org\/10.1186\/s12891-022-05279-9","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4,4]]},"assertion":[{"value":"31 July 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 March 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 April 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"In accordance with the Local Ministry of Health regulations, cadaveric studies are exempted and do not require institutional review board approval. All methods were performed in accordance with the relevant guidelines and regulations.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"N\/A.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"AK and MV are members of the Medical Advisory Board of TendoMend Ltd., the developer of the Dynamic Tendon Grip (DTG\u2122) device. AF has no competing interest to declare.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"320"}}