{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,11]],"date-time":"2026-11-11T14:45:48Z","timestamp":1794408348609,"version":"4.9.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,4,20]],"date-time":"2022-04-20T00:00:00Z","timestamp":1650412800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,4,20]],"date-time":"2022-04-20T00:00:00Z","timestamp":1650412800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BMC Musculoskelet Disord"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Use of dual mobility (DM) in total hip arthroplasty has gained popularity due to the ability to reduce dislocation through increased jumping distance and impingement-free arc of movement. Recently, modular dual mobility (modDM) systems were introduced to give the possibility to use DM with standard metal-backed shells, however few has been studied to date regarding how jumping distance and the center of rotation change with modDM. The objective of this study was to evaluate, through analytical simulation, how jumping distance, center of rotation and arc of movement change between DM and standard cups with modDM or fixed bearings (FB).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>3D-models of DM and standard press-fit cups with modDM or FB liners were used to simulate DM, modDM and FB implant configurations, matched for same cup size, according to same cup position and different femoral head diameters. Jumping distance was calculated and center of rotation lateralization and oscillation angles were measured for each size of these three implant configurations.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Jumping distance with modDM was reduced by -3.9\u00a0mm to -8.6\u00a0mm in comparison with DM, from 48 to 64\u00a0mm size, but resulted comparable to polyethylene 36\u00a0mm FB and increased by\u2009+\u20091.1\u00a0mm and\u2009+\u20091.4\u00a0mm than ceramic 36 and 40\u00a0mm FBs for sizes\u2009&gt;\u200954\u00a0mm. ModDM lateralized the center of rotation up to\u2009+\u20092.5\u00a0mm and\u2009+\u20094.0\u00a0mm in comparison with DM and FBs, respectively. Oscillation angle with modDM resulted higher than\u2009+\u200916\u00b0,\u2009+\u200923\u00b0,\u2009+\u200917\u00b0 and\u2009+\u200914\u00b0 in comparison to DM, 28\u00a0mm, 32\u00a0mm and 36\u00a0mm FB cups, respectively, for 56\u00a0mm cup size.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>According to its specific design, modDM might change hip stability parameters in comparison to DM, worsening jumping distance and center of rotation position, but increasing arc of movement. As not restoring stability parameters in the same fashion, modDM implants should be properly used when DM cups are not feasible.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12891-022-05280-2","type":"journal-article","created":{"date-parts":[[2022,4,20]],"date-time":"2022-04-20T18:02:42Z","timestamp":1650477762000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":31,"title":["Hip stability parameters with dual mobility, modular dual mobility and fixed bearing in total hip arthroplasty: an analytical evaluation"],"prefix":"10.1186","volume":"23","author":[{"given":"Domenico","family":"Tigani","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lorenzo","family":"Banci","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Riccardo","family":"Valtorta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luca","family":"Amendola","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,4,20]]},"reference":[{"key":"5280_CR1","unstructured":"Australian Report 2020. Orthopaedic Association National Joint Replacement Registry (AOANJRR). Hip, Knee & Shoulder Arthroplasty. Adelaide; AOA, 2020:1\u2013474. https:\/\/aoanjrr.sahmri.com\/annual-reports-2020 Accessed 08 Oct 2021."},{"issue":"5","key":"5280_CR2","doi-asserted-by":"publisher","first-page":"1349","DOI":"10.1007\/s11999-016-4966-1","volume":"475","author":"G Cafri","year":"2017","unstructured":"Cafri G, Paxton EW, Love R, Bini SA, Kurtz SM. Is There a Difference in Revision Risk Between Metal and Ceramic Heads on Highly Crosslinked Polyethylene Liners? Clin Orthop Relat Res. 2017;475(5):1349\u201355.","journal-title":"Clin Orthop Relat Res"},{"issue":"1","key":"5280_CR3","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1080\/17453674.2020.1845031","volume":"92","author":"EM Bloemheuvel","year":"2021","unstructured":"Bloemheuvel EM, Van Steenbergen LN, Swierstra BA. Low revision rate of dual mobility cups after arthroplasty for acute hip fractures: report of 11,857 hip fractures in the Dutch Arthroplasty Register (2007\u20132019). Acta Orthop. 2021;92(1):36\u20139.","journal-title":"Acta Orthop"},{"issue":"Suppl 4","key":"5280_CR4","doi-asserted-by":"publisher","first-page":"S42","DOI":"10.1016\/j.otsr.2011.03.011","volume":"97","author":"P Triclot","year":"2011","unstructured":"Triclot P, Gouin F. Update\u2013\"Big-head\": the solution to the problem of hip implant dislocation? Orthop Traumatol Surg Res. 2011;97(Suppl 4):S42\u20138.","journal-title":"Orthop Traumatol Surg Res"},{"issue":"Suppl 11","key":"5280_CR5","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1302\/0301-620X.94B11.30508","volume":"94","author":"JA Rodriguez","year":"2012","unstructured":"Rodriguez JA, Rathod PA. Large diameter heads: is bigger always better? J Bone Joint Surg Br. 2012;94(Suppl 11):52\u20134.","journal-title":"J Bone Joint Surg Br"},{"key":"5280_CR6","first-page":"15","volume":"1","author":"G Bousquet","year":"1985","unstructured":"Bousquet G, Gazielly D, Girardin P, Debiesse JL, Relave M, Israeli A. The ceramic coated cementless total hip arthroplasty. Basic concepts and surgical technique. J Orthop Surg Tech. 1985;1:15\u201328.","journal-title":"J Orthop Surg Tech."},{"key":"5280_CR7","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1007\/s002640050246","volume":"22","author":"F Farizon","year":"1998","unstructured":"Farizon F, De Lavison R, Azoulay JJ, Bousquet G. Results with a cementless alumina-coated cup with dual mobility A twelve-year follow-up study. Int Orthop. 1998;22:219\u201324.","journal-title":"Int Orthop"},{"issue":"1","key":"5280_CR8","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1007\/BF02474667","volume":"7","author":"J Charnley","year":"1969","unstructured":"Charnley J, Kamangar A, Longfield MD. The optimum size of prosthetic heads in relation to the wear of plastic sockets in total replacement of the hip. Med Biol Eng. 1969;7(1):31\u20139.","journal-title":"Med Biol Eng"},{"key":"5280_CR9","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1302\/0301-620X.48B2.245","volume":"48","author":"GK McKee","year":"1966","unstructured":"McKee GK, Watson-Farrar J. Replacement of arthritic hips by the McKee-Farrar prosthesis. J Bone Joint Surg [Br]. 1966;48:245\u201359.","journal-title":"J Bone Joint Surg [Br]"},{"issue":"Suppl 1","key":"5280_CR10","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1302\/0301-620X.99B1.BJJ-2016-0398.R1","volume":"99","author":"I De Martino","year":"2017","unstructured":"De Martino I, D\u2019Apolito R, Soranoglou VG, Poultsides LA, Sculco PK, Sculco TP. Dislocation following total hip arthroplasty using dual mobility acetabular components: a systematic review. Bone Joint J. 2017;99(Suppl 1):18\u201324.","journal-title":"Bone Joint J"},{"issue":"4","key":"5280_CR11","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1016\/j.artd.2019.09.006","volume":"5","author":"JA Dubin","year":"2019","unstructured":"Dubin JA, Westrich GH. Anatomic dual mobility compared to modular dual mobility in primary total hip arthroplasty: a matched cohort study. Arthroplasty Today. 2019;5(4):509\u201314.","journal-title":"Arthroplasty Today"},{"issue":"7S","key":"5280_CR12","doi-asserted-by":"publisher","first-page":"S287","DOI":"10.1016\/j.arth.2019.03.027","volume":"34","author":"RC Huang","year":"2019","unstructured":"Huang RC, Malkani AL, Harwin SF, Hozack WJ, Mont MA, Higuera-Rueda CA, et al. Multicenter Evaluation of a Modular Dual Mobility Construct for Revision Total Hip Arthroplasty. J Arthroplasty. 2019;34(7S):S287\u201391.","journal-title":"J Arthroplasty"},{"issue":"Suppl 6","key":"5280_CR13","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1302\/0301-620X.101B6.BJJ-2018-1403.R1","volume":"101","author":"BP Chalmers","year":"2019","unstructured":"Chalmers BP, Mangold DG, Hanssen AD, Pagnano MW, Trousdale RT, Abdel MP. Uniformly low serum cobalt levels after modular dual-mobility total hip arthroplasties with ceramic heads: a prospective study in high-risk patients. Bone Joint J. 2019;101(Suppl 6):57\u201361.","journal-title":"Bone Joint J"},{"issue":"9","key":"5280_CR14","doi-asserted-by":"publisher","first-page":"1035","DOI":"10.1302\/0301-620X.101B9.BJJ-2019-0377.R2","volume":"101","author":"DC Markel","year":"2019","unstructured":"Markel DC, Bou-Akl T, Rossi MD, Pizzimenti N, Wu B, Ren W. Blood metal levels, leucocyte profiles, and cytokine profiles in patients with a modular dual-mobility hip prosthesis: early results from a prospective cohort study. Bone Joint J. 2019;101(9):1035\u201341.","journal-title":"Bone Joint J"},{"issue":"4","key":"5280_CR15","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1302\/0301-620X.101B4.BJJ-2018-0834.R1","volume":"101","author":"D Nam","year":"2019","unstructured":"Nam D, Salih R, Nahhas CR, Barrack RL, Nunley RM. Is a modular dual mobility acetabulum a viable option for the young, active total hip arthroplasty patient? Bone Joint J. 2019;101(4):365\u201371.","journal-title":"Bone Joint J"},{"issue":"5","key":"5280_CR16","doi-asserted-by":"publisher","first-page":"1535","DOI":"10.1007\/s11999-014-3469-1","volume":"472","author":"C Heffernan","year":"2014","unstructured":"Heffernan C, Banerjee S, Nevelos J, Macintyre J, Issa K, Markel DC, et al. Does dual-mobility cup geometry affect posterior horizontal dislocation distance? Clin Orthop Relat Res. 2014;472(5):1535\u201344.","journal-title":"Clin Orthop Relat Res"},{"issue":"3","key":"5280_CR17","doi-asserted-by":"publisher","first-page":"277","DOI":"10.3109\/17453670902988378","volume":"80","author":"E Sariali","year":"2009","unstructured":"Sariali E, Lazennec JY, Khiami F, Catonn\u00e9 Y. Mathematical evaluation of jumping distance in total hip arthroplasty: influence of abduction angle, femoral head offset, and head diameter. Acta Orthop. 2009;80(3):277\u201382.","journal-title":"Acta Orthop"},{"issue":"2","key":"5280_CR18","doi-asserted-by":"publisher","first-page":"217","DOI":"10.2106\/00004623-197860020-00014","volume":"60","author":"GE Lewinnek","year":"1978","unstructured":"Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60(2):217\u201320.","journal-title":"J Bone Joint Surg Am"},{"issue":"1","key":"5280_CR19","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/j.jbiomech.2004.03.012","volume":"38","author":"F Yoshimine","year":"2005","unstructured":"Yoshimine F. The influence of the oscillation angle and the neck anteversion of the prosthesis on the cup safe-zone that fulfills the criteria for range of motion in total hip replacements. The required oscillation angle for an acceptable cup safe-zone. J Biomech. 2005;38(1):125\u201332.","journal-title":"J Biomech."},{"issue":"8","key":"5280_CR20","first-page":"E53","volume":"42","author":"P Rathi","year":"2013","unstructured":"Rathi P, Pereira GC, Giordani M, Di Cesare PE. The pros and cons of using larger femoral heads in total hip arthroplasty. Am J Orthop (Belle Mead NJ). 2013;42(8):E53\u20139.","journal-title":"Am J Orthop (Belle Mead NJ)"},{"key":"5280_CR21","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1097\/01.blo.0000150310.25603.26","volume":"429","author":"HC Amstutz","year":"2004","unstructured":"Amstutz HC, Le Duff MJ, Beaul\u00e9 PE. Prevention and treatment of dislocation after total hip replacement using large diameter balls. Clin Orthop Relat Res. 2004;429:108\u201316.","journal-title":"Clin Orthop Relat Res"},{"issue":"2","key":"5280_CR22","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1007\/s11999.0000000000000035","volume":"476","author":"MA Hartzler","year":"2018","unstructured":"Hartzler MA, Abdel MP, Sculco PK, Taunton MJ, Pagnano MW, Hanssen AD. Otto Aufranc Award: Dual-mobility Constructs in Revision THA Reduced Dislocation, Rerevision, and Reoperation Compared With Large Femoral Heads. Clin Orthop Relat Res. 2018;476(2):293\u2013301.","journal-title":"Clin Orthop Relat Res"},{"issue":"9","key":"5280_CR23","doi-asserted-by":"publisher","first-page":"S220","DOI":"10.1016\/j.arth.2017.03.035","volume":"32","author":"EG Sutter","year":"2017","unstructured":"Sutter EG, McClellan TR, Attarian DE, Bolognesi MP, Lachiewicz PF, Wellman SS. Outcomes of Modular Dual Mobility Acetabular Components in Revision Total Hip Arthroplasty. J Arthroplasty. 2017;32(9):S220\u20134.","journal-title":"J Arthroplasty"},{"issue":"3","key":"5280_CR24","doi-asserted-by":"publisher","first-page":"1033","DOI":"10.1016\/j.arth.2016.09.038","volume":"32","author":"TD Tarity","year":"2017","unstructured":"Tarity TD, Koch CN, Burket JC, Wright TM, Westrich GH. Fretting and Corrosion at the Backside of Modular Cobalt Chromium Acetabular Inserts: A Retrieval Analysis. J Arthroplasty. 2017;32(3):1033\u20139.","journal-title":"J Arthroplasty"},{"issue":"6","key":"5280_CR25","doi-asserted-by":"publisher","first-page":"1273","DOI":"10.1016\/j.arth.2019.02.008","volume":"34","author":"DJ Lombardo","year":"2019","unstructured":"Lombardo DJ, Siljander MP, Gehrke CK, Moore DD, Karadsheh MS, Baker EA. Fretting and Corrosion Damage of Retrieved Dual-Mobility Total Hip Arthroplasty Systems. J Arthroplasty. 2019;34(6):1273\u20138.","journal-title":"J Arthroplasty"},{"issue":"11","key":"5280_CR26","doi-asserted-by":"publisher","first-page":"3326","DOI":"10.1016\/j.arth.2020.05.075","volume":"35","author":"JM Kolz","year":"2020","unstructured":"Kolz JM, Wyles CC, Van Citters DW, Chapman RM, Trousdale RT, Berry DJ. In Vivo Corrosion of Modular Dual-Mobility Implants: a retrieval study. J Arthroplasty. 2020;35(11):3326\u20139.","journal-title":"J Arthroplasty"},{"issue":"4","key":"5280_CR27","doi-asserted-by":"publisher","first-page":"699","DOI":"10.1016\/j.artd.2020.07.034","volume":"6","author":"BP Chalmers","year":"2020","unstructured":"Chalmers BP, Dubin J, Westrich GH. Modular Dual-Mobility Liner Malseating: a radiographic analysis. Arthroplast Today. 2020;6(4):699\u2013703.","journal-title":"Arthroplast Today"},{"issue":"Suppl 7","key":"5280_CR28","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1302\/0301-620X.102B7.BJJ-2019-1633.R1","volume":"102","author":"J Romero","year":"2020","unstructured":"Romero J, Wach A, Silberberg S, Chiu YF, Westrich G, Wright TM, et al. 2020 Otto Aufranc Award: Malseating of modular dual mobility liners. Bone Joint J. 2020;102(Suppl 7):20\u20136.","journal-title":"Bone Joint J"},{"issue":"9","key":"5280_CR29","doi-asserted-by":"publisher","first-page":"2040","DOI":"10.3390\/ma13092040","volume":"13","author":"S Affatato","year":"2020","unstructured":"Affatato S, Castiello E, Amendola L, Comitini S, Prudhon JL, Tigani D. Revision of a Monoblock Metal-on-Metal Cup Using a Dual Mobility Component: Is It a Reasonable Option? Materials. 2020;13(9):2040.","journal-title":"Materials"},{"key":"5280_CR30","doi-asserted-by":"crossref","unstructured":"De Smet K, Van Der Straeten C. Design issues and comparison of hip resurfacing prostheses. In: De Smet, K, Campbell PN, Van Der Straeten C, editors. The Hip Resurfacing Handbook. A practical guide to the use and management of modern hip resurfacings. Woodhead Publishing: Cambridge, UK; 2013. p. 88.","DOI":"10.1533\/9780857096203.1.88"}],"container-title":["BMC Musculoskeletal Disorders"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05280-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12891-022-05280-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12891-022-05280-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,4,21]],"date-time":"2022-04-21T14:10:28Z","timestamp":1650550228000},"score":1,"resource":{"primary":{"URL":"https:\/\/bmcmusculoskeletdisord.biomedcentral.com\/articles\/10.1186\/s12891-022-05280-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4,20]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["5280"],"URL":"https:\/\/doi.org\/10.1186\/s12891-022-05280-2","relation":{},"ISSN":["1471-2474"],"issn-type":[{"value":"1471-2474","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,4,20]]},"assertion":[{"value":"8 October 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 March 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 April 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"LB and RV are employed in Clinical and Research Departments at Permedica Orthopaedics, Merate (LC), Italy. The other authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"373"}}